| 1 | Carraige upto site , erection,Testing and commisioning of11/0.433KV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2 (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings ). From divisional Stores. |
| 2 | 25 KVA |
| 3 | 63 KVA |
| 4 | 100 KVA |
| 5 | 200 KVA |
| 6 | 250 KVA |
| 7 | 400 KVA |
| 8 | Carraige upto site, installation, testing and Commissioning of Gapless Surge Arrestor 9 kV, 10 kA, LA with polymer housing, Stn. Type. |
| 9 | Carraige upto site, installation, testing and Commissioning of 11 kV G.O Switch(200 Amp) (vertical type), with fittings complete in all respects. |
| 10 | Carraige upto site, installation, testing and Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A. |
| 11 | Supply, Carraige upto site, installation, testing and Commissioning of Gapless Surge Arrestor 9 kV, 10 kA, LA with polymer housing, Stn. Type. |
| 12 | Supply, Carraige upto site, installation, testing and Commissioning of 11 kV G.O Switch(200 Amp (vertical type), with fittings complete in all respects. |
| 13 | Supply, Carraige upto site, installation, testing and Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A. |
| 14 | Supply, Carraige upto site, laying, stringing, tensioning, binding of 1.1 KV grade, 1-core (2Ckt) 300 /240Sqmm PVC Conductor FRLS type. |
| 15 | Supply, Carraige upto site, laying, stringing, tensioning, binding of 1.1 KV grade, 1-core 185/120 Sqmm PVC Conductor FRLS type. |
| 16 | Earthing of substation-Excavation ofearth pit of dia650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 75 mmx10 mm& 50 mmx6 mm,for connection of transformer body & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 17 | Supply, carriage, installation and commissioning of temporary LT Fuse unit Complete as per REC standards/drawings available on KPDCL website. |
| 18 | Supply,Carraige upto site, fixing ofAluminium Thimbles of size 300/240 Sqmm. |
| 19 | Supply,Carraige upto site, fixing ofAluminium Thimbles of size 185/120 Sqmm. |
| 20 | Supply,Carraige upto site, fixing and Commissioning of Aluminium Solderless Clampsof size 300 /240Sqmm. |
| 21 | Supply,Carraige upto site, fixing and Commissioning of Aluminium Solderless Clampsof size 185/120 Sqmm. |
| 22 | Carraige from store upto site, Erection,testing and commisioning ofSteel Tubular Poles of sizes complete with base plate(300x300x5mm), top cap, including digging of pit (1/6th of pole height) positioning etc, complete in all respect as per REC Standard. |
| 23 | 13 m Long ( ST- 410 SP69) |
| 24 | 11 m Long ( ST- 410 SP56) |
| 25 | 9 m Long ( ST- 410 SP33) |
| 26 | 8 m Long ( ST- 410 SP15) |
| 27 | 8 m Long (PCC-WL250KG) |
| 28 | Supply,Carraige upto site, fixing and installation of GI V Cross-arm with top braket including clamps as per REC Standards/as per drawings available on KPDCL website. |
| 29 | Carraige upto site, fixing and installation of GI V Cross-arm with top braket including clamps as per REC Standards/as per drawings available on KPDCL website. |
| 30 | Supply,Carraige upto site, fixing and installation of GI X-arm including clamps and braces as per REC Standards/ as per drawings available on KPDCL website. |
| 31 | Carraige upto site, fixing and installation of GI X-arm including clamps and braces as per REC Standards/ as per drawings available on KPDCL website. |
| 32 | Supply, Carraige upto site, laying, stringing, tensioning, binding of ACSR Conductor of sizes complete in all respects as per REC standards. |
| 33 | 100 Sqmm |
| 34 | 50 Sqmm |
| 35 | 30 sqmm |
| 36 | Carraige from store upto site, laying, stringing, tensioning, binding of ACSR Conductor of sizes complete in all respects as per REC standards |
| 37 | 100 Sqmm |
| 38 | 50 Sqmm |
| 39 | 30 sqmm |
| 40 | Supply, carriage and fixing of PG clamps Complete as per standards |
| 41 | 100 Sqmm |
| 42 | 50 Sqmm |
| 43 | 30 sqmm |
| 44 | Supply,Carraige upto site, fixing and installation of GI Mukhi Clamps for shackle insulators. |
| 45 | Carraige upto site, fixing and installation of GI Mukhi Clamps for shackle insulators. |
| 46 | Supply, Carraige upto site, fixing and installation of 16kN porcelain shackle insulators. |
| 47 | Carraige upto site, fixing and installation of 16kN porcelain shackle insulators. |
| 48 | Supply, Carraige upto site, installation,testing and Commissioning of 11 kV Disc Insulators (porcelain) Complete with fitting(45KN),complete in all respects as per REC standards. |
| 49 | Supply, Carraige upto site,Carraige upto site,Installation,testing and Commissioning of 11 kV Disc Insulators (polymer) Complete with fitting(45KN),complete in all respects as per REC standards. |
| 50 | Supply, Carraige upto site,Installation,testing and Commissioning of 11 KV Pin Insulators (porcelain) with Pins (5KN),complete in all respects as per REC standards. |
| 51 | Supply, Carraige upto site,Installation,testing and Commissioning of 11 KV Pin Insulators (polymer) with Pins (5KN),complete in all respects as per REC standards. |
| 52 | Supply, Carraige upto site and installation of Danger Plates with Clamps. |
| 53 | Supply, Carraige upto site and installation of Anti Climbing devices |
| 54 | Carraige from store upto site and installation of Anti Climbing devices |
| 55 | Supply, carriage and installation of LT Line Spacers. |
| 56 | Earthing complete by GI pipe 40mm or GI rod 20 mm 2.5 mtr long through GI strip of Poles. |
| 57 | Painting of poles with Red oxide. |
| 58 | Painting of poles with Aluminiun paint. |
| 59 | Cement bottoming 1:2:4 mix as per Standards 0.40 cum / pole for ( 8 Mtr ST Pole)as per drawings available on KPDCL website. |
| 60 | Cement bottoming of S T poles in 1:2:4 mix as per REC standards 0.5 cum/pole/ as per drawings available on KPDCL website. |
| 61 | Cement bottoming 1:2:4 mix as per Standards 0.66 cum/pole ( 11 MtrST Pole )as per drawings available on KPDCL website. |
| 62 | Supply, carriage and fixing of Aluminium Jointing Sleeves. |
| 63 | Supply, Carraige upto site,Installation,testing and Commissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2NO..), anchor plate (200x 200 x 6 mm), nut-bolts, 2 NO. turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete with all fittings as per REC Standards |
| 64 | Supply, Carraige upto site,laying ,stringing,tensioning , binding of 11 KV grade, AB HT cable of sizes |
| 65 | 35 mm² AB (HT) Cable (3x35+1x70 mm²) XLPE (11 kV, 3C + Earth) |
| 66 | 50 mm² AB (HT) Cable (3x50 + 1x70 mm²) XLPE (11 kV, 3C + Earth) |
| 67 | 70 mm² AB (HT) Cable (3 x 70 + 1x70 mm²) XLPE |
| 68 | 120 mm² AB (HT) Cable (3x120 + 1x95 mm²) XLPE (11 kV, 3C + Earth) |
| 69 | 185 sqmm AB (HT) Cable (3x185 + 1x95 mm²) XLPE (11 kV, 3C + Earth) |
| 70 | Supply,Carraige upto site,Installation,testing and Commissioning of Heat shrinkable 1-core cable termination kit(indoor / outdoor type) of sizes. |
| 71 | 35 sqmm |
| 72 | 50 sqmm |
| 73 | 70 sqmm |
| 74 | 95 sqmm |
| 75 | 120 sqmm |
| 76 | 185 sqmm |
| 77 | Supply, Carraige upto site, laying, binding of 11 KV grade, 3-core XLPE, armoured, FRLS cable of sizes |
| 78 | 35 sqmm |
| 79 | 50 sqmm |
| 80 | 70 sqmm |
| 81 | 95 sqmm |
| 82 | 120 sqmm |
| 83 | 150 sqmm |
| 84 | 185 sqmm |
| 85 | 240 sqmm |
| 86 | 300 sqmm |
| 87 | 400 sqmm |
| 88 | Supply,Carraige upto site,Installation,testing and Commissioning of Heat shrinkable 11 KV grade 3-core cable termination kit(indoor / outdoor type) of sizes |
| 89 | 35 sqmm |
| 90 | 50 sqmm |
| 91 | 70 sqmm |
| 92 | 95 sqmm |
| 93 | 120 sqmm |
| 94 | 185 sqmm |
| 95 | 240 sqmm |
| 96 | 300 sqmm |
| 97 | 400 sqmm |
| 98 | Supply,Carraige upto site,Installation,testing and Commissioning of LED Lights. |
| 99 | 30 watt |
| 100 | 45 watt |
| 101 | 70 watt |
| 102 | 120 watt |
| 103 | Carraige upto site,Installation,testing and Commissioning of LED Lights(From divisional stores) |
| 104 | 30 watt |
| 105 | 45 watt |
| 106 | 70 watt |
| 107 | 120 watt |
| 108 | Supply, Carraige upto site,laying ,stringing,tensioning , binding of 1.1 KV grade, 4-core armoured FRLS Type cable of sizes |
| 109 | 35 sqmm |
| 110 | 25 sq mm |
| 111 | 16 sq mm |
| 112 | Supply, Carraige upto site,laying ,stringing,tensioning , binding of Single-Core Cable,1.1kV Grade, XLPE un armoured FRLS type |
| 113 | 25 sq mm |
| 114 | 35 sq mm |
| 115 | 50 sq mm |
| 116 | 70 sq mm |
| 117 | 95 sq mm |
| 118 | 120 sq mm |
| 119 | 185 sq mm |
| 120 | 240 sq mm |
| 121 | 400 sq mm |
| 122 | Supply, Carraige upto site,laying ,stringing,tensioning , binding of 1.1 KV grade, LT AB cable of sizes |
| 123 | 35 mm² AB (LT) Cable ( 3 x 35 + 1 x 16 + 1 x 25 mm²) XLPE (1.1kV, 3+1 C, Al) |
| 124 | 50 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35 mm²) XLPE (1.1kV, 3+1 C, Al) |
| 125 | 70 mm² AB (LT) Cable ( 3 x 70 + 1 x 16 + 1 x 50 mm²) XLPE (1.1kV, 3+1 C, Al) |
| 126 | 120 mm² AB (LT) Cable ( 3 x 120 + 1 x 25 + 1 x 95 mm²) XLPE (1.1kV, 3+1 C, Al) |
| 127 | 185 mm² AB (LT) Cable ( 3 x 185+ 1 x 25 + 1 x 95 mm²) XLPE (1.1kV, 3+1 C, Al) |
| 128 | Supply, Carraige upto site,fixing,testing and commissioning ofLT 3-phase Pole Mounted Distribution box with Busbar. |
| 129 | Supply, Carraige upto site,fixing of Cable piericing connectors of sizes (16sqmm -120sqmm) |
| 130 | Supply, Carraige upto site,fixing of Cable straight through cable jointing kit of sizes for LT AB Cable. |
| 131 | 10 sq mm |
| 132 | 04 sq mm |
| 133 | Dismantling, safe packing and transportation to divisional stores of11/0.433KV, 3-phase Distribution Transformers incuding unloading and staking. |
| 134 | 25 KVA |
| 135 | 63 KVA |
| 136 | 100 KVA |
| 137 | 200 KVA |
| 138 | 250 KVA |
| 139 | 400 KVA |
| 140 | Dismantling, safe packing and transportation to divisional stores of Gapless Surge Arrestor 9 kV, 10 kA, LA with polymer housing, Stn. Type incuding unloading and staking. |
| 141 | Dismantling, safe packing and transportation to divisional storesof 11 kV G.O Set (vertical type), with fittings,incuding unloading and staking. |
| 142 | Dismantling, safe packing and transportation to divisional stores of 11 kV Horn Gap Fuse Set 3 Phase 200A,incuding unloading and staking. |
| 143 | Dismantling, safe packing and transportation to divisional stores of 1.1 KV grade, cable of sizes,incuding unloading and staking. |
| 144 | Dismantling, safe packing and transportation to divisional storesof LT Fuse unit,incuding unloading and staking. |
| 145 | Dismantling, Removing, safe packing and transportation to divisional stores at Budgam from different sites ,oldSteel Tubular Poles of sizes , top cap, cross arms, braces,insulators etc,incuding unloading and staking. |
| 146 | Dismantling, Removing, disposing off and dumping at suitable places/staking at stores as decided by the site engineerfrom different sites ,of oldPCC Poles of sizes. |
| 147 | Dismantling, Removing, safe packing and transportation to divisional stores at Budgam from different sites ,of old wooden Poles of sizes, braces,insulators etc,incuding unloading and staking. |
| 148 | Dismantling, safe packing and transportation to divisional stores of ACSR conductor of sizes,incuding unloading and staking. |
| 149 | Dismantling, safe packing and transportation to divisional stores of old HT/LTcable of sizes,incuding unloading and staking. |
| 150 | Dismantling, safe packing and transportation to divisional storesof old/damaged 11 Kvlinksets,incuding unloading and staking. |
| 151 | Branch cutting/cutting down of various kinds of trees/branchesfalling under the corridore of HT / LT network |
| 152 | Stringing/re-alignment of already laidconductor of sizes (30Sqmm-150 Sqmm) |
| 153 | Supply,installation,testing and commissioning of 09 watt LED lamps with 5 Amp. Switches. complete in all respects as per standards. |
| 154 | Supply,installation,testing and commissioning of5 Amp. Switches. complete in all respects as per standards. |
| 155 | Supply,installation,testing and commissioning of 15 Amp SS combineincluding 10 Amp Double pole protectiveMCB\"s for protection.complete in all respects as per standards. |
| 156 | Supply,installation,testing and commissioning of1.5 sqmm copper conductor PVC wiringcomplete in all respects as per standards. |
| 157 | Supply,installation,testing and commissioning of2.5 sqmm copper conductor PVC wiringcomplete in all respects as per standards. |
| 158 | Supply,installation,testing and commissioning of4.0sqmm copper conductor PVC wiringfor main supply (service wire) complete in all respects as per standards. |
| 159 | Supply,installation,testing and commissioning of10.0sqmm copper conductor PVC wiringfor main supply (service wire) complete in all respects as per standards. |
| 160 | Supply,installation,testing and commissioning of16.0sqmm Al. conductor PVC wiringfor main supply (service wire) complete in all respects as per standards. |
| 161 | Supply of 2800 VA generator on hire charges basisfor backup power supply (rates may be quoted for daily basis------24 Hrs) |
| 162 | Providing of multi coloured decorative illumination (zool) on hire charge basis to various government offices and buildings on the occasion of Independence day/republic day celebrations and other events. |
| 163 | Supply of 10 KVA generators on hire charges basisfor backup power supply along with Change Over Switch of suitable Capacity with operator (Rates may be quoted for daily basis------24 Hrs) along operator. |
| 164 | Supply of fuel forgeneratorsfor backup power supply. |
| 165 | Supply of 63 KVA generators on hire charges basisfor backup power supply along with Change Over Switch of suitable Capacity with operator (Rates may be quoted for daily basis------24 Hrs) along operator. |
| 166 | Watch and ward for electrification system for yatra camps/ polling stations /camping sites/ etc(Rates may be quoted for daily basis------24 Hrs) |
| 167 | Supply,Carraige upto site, Erection,testing and commisioning ofSteel Tubular Poles of sizes complete with base plate(300x300x5mm), top cap, including digging of pit (1/6th of pole height) positioning etc, complete in all respect as per REC Standard. |
| 168 | 13 m Long ( ST- 410 SP69) |
| 169 | 11 m Long ( ST- 410 SP56) |
| 170 | 9 m Long ( ST- 410 SP33) |
| 171 | 8 m Long ( ST- 410 SP15) |
| 172 | Supply,Carraige upto site,Installation,testing and Commissioning of11 KV grade 3-core cable jointing kitsof sizes |
| 173 | 35 sqmm |
| 174 | 50 sqmm |
| 175 | 70 sqmm |
| 176 | 95 sqmm |
| 177 | 120 sqmm |
| 178 | 185 sqmm |
| 179 | 240 sqmm |
| 180 | 300 sqmm |
| 181 | 400 sqmm |
| 182 | Carraige upto site,Installation,testing and Commissioning of11 KV grade 3-core cable jointing kitsof sizes |
| 183 | 35 sqmm |
| 184 | 50 sqmm |
| 185 | 70 sqmm |
| 186 | 95 sqmm |
| 187 | 120 sqmm |
| 188 | 185 sqmm |
| 189 | 240 sqmm |
| 190 | 300 sqmm |
| 191 | 400 sqmm |
| 192 | Supply,Carraige upto site , erection,Testing and commisioning of11/0.433KV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2 (Aluminium wound upto 200KVA, Copper wound for 250KVA ). |
| 193 | 25 KVA |
| 194 | 63 KVA |
| 195 | 100 KVA |
| 196 | 200 KVA |
| 197 | 250 KVA |
| 198 | 3-Ø, 4-Wire Trivector Meter (Prodigy) suitable up to 100 KVA DTR. |
| 199 | Single Phase Smart Energy Meter 10-60 Amp, DLMS Complaint of accuracy class 1.0 |
| 200 | Polypropylene weather proof outdoor type Meter Box for Single Phase Meter along with Zinc plated clamps |
| 201 | 35 mm² Cable (4C) from LT Line to meter,1.1kV Grade, Armoured,XLPE Insulated Stranded Conductor FRLS type |
| 202 | 10 mm²/16 mm² Cable (4C) from meter to consumer cut out ,1.1kV Grade,Armoured, XLPE Insulated Stranded Conductor FRLS type |
| 203 | 3 phase Smart Energy Meter 20-80 Amp, DLMS Compliant of accuracy class 1.0 |
| 204 | Polypropylene weather proof outdoor type Meter Box for Three Phase Meter along with Zinc plated clamps |
| 205 | LT 16 mm² 2 Core XLPE service cable armoured |
| 206 | Main Service Distribution Box |
| 207 | Single Phase (smart/ prepaid) Energy Meter 5-30 Amp, DLMS Complaint of accuracy class |
| 208 | Polypropylene weather proof outdoor type Meter Box for 4 Single Phase Meter along with Zinc plated clamps |
| 209 | Supply,Carraige upto site, installation,testing and commisioning of 11 KV Metering Unit CT/PT operated for various capacities of distribution Transformers as per KPDCL guidelines complete in all respects (Foundation ,earthing etc) |
| 210 | Carraige upto site , erection,Testing and commisioning ofEnergy Meters |
| 211 | 3-Ø, 4-Wire Trivector Meter (Prodigy) suitable up to 100 KVA DTR. |
| 212 | Single Phase Smart Energy Meter 10-60 Amp, DLMS Complaint of accuracy class 1.0 |
| 213 | Polypropylene weather proof outdoor type Meter Box for Single Phase Meter along with Zinc plated clamps |
| 214 | 3 phase Smart Energy Meter 20-80 Amp, DLMS Compliant of accuracy class 1.0 |
| 215 | 3 phase Smart Net Energy Meter 20-80 Amp, DLMS Compliant of accuracy class 1.0 |
| 216 | Polypropylene weather proof outdoor type Meter Box for Three Phase Meter along with Zinc plated clamps |