| 1 | W1 conveyor floor area repair work and painting during ATA-2025 at Sulphate plant in FACTUdyogamandal. |
| 2 | Dismantling and removing the existing CC/RCC works and conveying and depositing the debris at places pointed out within a distance of 150M as directed by Engineer-in-charge |
| 3 | Demolishing and removing old cement plaster and disposal of the debris at places pointed out within a distance of 150M. |
| 4 | Dismantling carefully the damaged portion of the existing Acid Resistant Tiles of all thickness upto and including 40mm without disturbing the unaffected lining works from floors, drains, cooler basin etc. of all shapes & sizes, neatly dressing and stacking the serviceable bricks for reuse and disposal of the unserviceable dismantled items at low lying areas / places pointed out with in the factory premises. |
| 5 | Cleaning the loose particles,dust, oily/greasy materials,bitumen dippings,sealants etc. on the road surface/floor at different levels withbroom / wire brush & water washing, air compressor etc.with all charges as per departmental instructions. |
| 6 | Providing form work to RCC / CC works with necessary wooden planks, joists, runners, struts, posts etc. including removal after completion/ curing for foundation footings, machine equipment foundations and pedastals over foundation footings, sides of trench walls, plinth beams and rafts, pile caps and mass concrete works etc.at all levels inside factory area. |
| 7 | Supplying Portland pozzolana cement (PPC) of grade 53 conforming to IS1489 part-1 in 50 kg bags |
| 8 | Providing reinforcement to RCC works at all levels with MS or deformed bars including all charges for uncoiling and straightening rods, cutting rods, bending cold, placing in position and tying with tying wire of suitable gauge etc.complete.( Only Reinforcement Rods will be issued free of cost by the company ) |
| 9 | Supplying of latex based multipurpose polymer SikaLatex® Power of Sika / Nitobond® SBR(Latex) of FOSROC or equivalent for adding to mortar at site. |
| 10 | RCC or CC work 1:2:4 mix, using 20mm nominal size broken stone excluding cost of form work and reinforcement. |
| 11 | Plastering with cement mortar 1:4, 15mm thick, one coat floated hard and trowelled smooth at all levels. |
| 12 | Providing and laying in position ready mixed M-20 grade concrete for reinforced cement concrete work, using fly ash and cement content as per approved design mix, and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer in - charge. NOTE- (1) Minimum Cement content shall be @ 300 kg/cum. Excess cement used as per design mix is payable separately. \"(2) Fly ash conforming to grade I of IS 3812 (Part-1) only be used as part replacement of OPC as per IS: 456. Uniform blending with cement to be ensured in accordance with clauses 5.2 and 5.2.1 of IS:456 in the items of BMC and RMC. |
| 13 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 14 | Fresh lining / repairing the lining using Acid ResistantTiles of all thickness upto and including40mm with suitable mortar for floors, drains, cooler basins etc. of all shapes and sizes including transporting of all the required materials from Udyogamandal General Stores/Civil Maintenance Office stores/Plant Stock Yards to the work site, preparation of the required mortar as directed, (lining materials will be issued free of cost). |
| 15 | Providing & laying 10 mm thick Heavy dutyacid/alkali resistant vitrified industrial tiles of size 300 x 300 mm or nearest size conforming to IS 4457, of approved make( Johnson enduraor equivalent ), in all colours & shades , laid on 20mm thk cement mortar 1:4 ( 1 cement : 4 M.sand ), including grouting the joints of width 3 mm- 5mm , using epoxy grout mix of 0.70 kg of organic coated filler of desired shade ( 0.10 kg of hardener & 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 16 | Providing & laying 10 mm thick Heavy duty Acid/Alkali resistant vitrified industrial tiles of size 300x300 mm or nearest size confirming to IS 4457, of approved make ( Johnson endura or equivalent ), in all colours & shades, in dado/skirtings, riser of steps, laid on 12mm thk cement mortar 1:3 ( 1 cement : 3 M.sand ), including grouting the joints of width 3 mm- 5mm , using epoxy grout mix of 0.70 kg of organic coated filler of desired shade ( 0.10 kg of hardener & 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction |
| 17 | Cleaning the structural / other surface neatly at all heights, manually with suitable tools or with high pressure water jet spray (using suitable machanical means), and scraping if required, to remove the whole accumulated dust, rust, dirt etc. as per departmental instructions. |
| 18 | Painting two coats of single pack, lead free, acid and alkali resistant black bituminous paint of approved quality confirming to IS: 9862 after removing the loose materials, dust, oil, grease and cleaning the surface etc. carefully without damaging the surface including cost of paint materials, labour charges etc. complete as per departmental instructions at site. |