| 1 | Fixed Volume Pipettes 1mL. Now, silent and effortless with textured adjustment knob for a firmer feel (thermofisher/eppordorf/BRnds) alongwith 200 tips autoclavable. |
| 2 | Fixed Volume Pipettes 10 mL Now, silent and effortless with textured adjustment knob for a firmer feel (thermofisher/eppordorf/BRnds) alongwith 10 tips autoclavable |
| 3 | Fluoride standard- 1000 ppm nist traceable with certificate make merck sigma- 500ml atleast with 2-3 years expiry date with ISO: 17034 |
| 4 | Iron standard - 1000 ppm nist traceable with certificate make merck sigma- 500ml atleast with 2-3 years expiry date with ISO: 17034 |
| 5 | Nitrate standard- 1000 ppm nist traceable with certificate make merck sigma- 500ml atleast with 2-3 years expiry date with ISO: 17034 |
| 6 | Photometric test kit for measurement of Iron Fe Number of tests: 100 (Powder Pillows) Sample volume required: 10ml Compatible with photometers: 0.00 - 3.00 mg/l Fe atleast with 2-3 years expiry date |
| 7 | Photometric test kit for measurement of Nitrate NO2 Number of tests: 100 (Powder Pillows) Sample volume required: 10ml Compatible with photometers: pHotoFlex 0.00 - 0.33 mg/l NO2-N: 0.00 - 1.08 mg/l NO2atleast with 2-3years expiry date |
| 8 | Photometric test kit for measurement of Sulfate SO4Number of tests: 100 (Powder Pillows)Sample volume required: 10mlCompatible with photometers:pHotoFlex 0 - 70 mg/l SO4 atleast with 2-3 years expiry date |
| 9 | Round 16 mm Quartz Cells round cuvettes, empty (16 mm diameter). (as compatiable with instrument) |
| 10 | Sulfate standard- 1000 ppm nist traceable with certificate make merck sigma- 500ml atleast with 2-3 years expiry date with ISO: 17034 |
| 11 | CMCfor spectrophtometer for 2 years after completion of 3 years warranty |
| 12 | Credit of old DR 6000 spectrophotometer (unrepaired) complete in all respect. |
| 13 | US VIS SPECTROPHOTOMETER with Double Beam Source Lamp: Tungsten(visible range), Typical wavelength range: 190-1100 nm, wavelength accuracy: ± 1 nm but not less than±0.5 nm, Spectral Bandwidth: 2 nm but it should not be more than 4 nm, Scanning Speed: Max 2000 nm/min (in 1 nm steps), etc. and instrument complete in all respect as per standard specifications exclusive of GST.(Make: HACH/ WTW-Xylem/ Thermo Orion/ Lovibond), Warranty: 3 years. |
| 14 | 10mm 1 rectangular cuvette quartz, layer thickness 10 mm. Quartz Cells (as compatiable with instrument) |
| 15 | 20mm- 1 rectangular cuvette quartz, layer thickness 20 mm. (as compatiable with instrument) |
| 16 | 50 mm Quartz Cells -1 rectangular cuvette quartz, layer thickness 50 mm. (as compatible with instrument) |