Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #48924436

Construction Of 6 Nos Type-Iv Quarters For Docters At Seijosa And Pakke Kessang

Issued by Government Departments · Pakke Kessang, Arunachal Pradesh
Tender Value
24.05 Lakhs
Estimated cost
Bid Submission
13 May 2025
0 days left
EMD
2.40 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pakke Kessang → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

construction of 6 Nos Type-Iv Quarters For Docters At Seijosa And Pakke Kessang

BOQ

Name of Work: C/O 6 Nos Type-IV Quarters for Docters at Seijosa & Pakke Kessang
Sl. No. Item Description
1(A) SITE DEVELOPMENT WORK
2Clearing and Grubbing Road Land . (Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.) -In area of thorny jungle`
3Excavation in Soil with Dozer with lead upto 100 metres (Excavation for road way in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 metres (average lead50 metres), including trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections.)
4Excavation in ordinary rock by manual means (Excavation in ordinary rock using manual means including loading in a truck and carrying of excavated material to embankment site with in all lifts and leads upto 1000 metres )
5(B) CIVIL CONSTRUCTION WORK
6Surface dressing of the ground, including removing vegetation and inequalities not exceeding 15 cm depth and disposal of rubbish, lead upto 50 m and lift upto 1.50 m
7Earth work in excavation in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) including banking in 20 cm layers and breaking clods, ramming and dressing up for the purpose of making embankments or filling up ground depressions, lead upto 50 m and lift upto 1.50 m.
8Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost ofcentring and shuttering.
9Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M-20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) Footing
10Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement (a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).columns upto plinth level
11Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). Plinth band & Tie Beams
12Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete
13Centring and shuttering including strutting, propping etc and removal of form work for : e) Column, pillars, posts and struts etc.
14Centring and shuttering including strutting, propping etc and removal of form work for : d) Lintels, beams, girders, bressumers and cantilevers etc
15Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand).
1615 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall
17Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement morter 1:2 (1 cement : 2 coarse sand) to match the existing floor
18Applying a coat of hot bitumen (mashphalte 80/100 or equivalent) using 1.70 Kg per Sq.m. on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
19Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand).Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level.
20Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.+ Extra for half brick masonry in superstructure above plinth level and up to floor two level.
216 mm cement plaster 1 : 3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams
22Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). Lintel band
23Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).columns
24Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). Beam
25Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishingand plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M-20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).slab
26Centring and shuttering including strutting, propping etc and removal of form work for : d) Lintels, beams, girders, bressumers and cantilevers etc
27Centring and shuttering including strutting, propping etc and removal of form work for : e) Column, pillars, posts and struts etc.
28Centring and shuttering including strutting, propping etc and removal of form work for : d) Lintels, beams, girders, bressumers and cantilevers etc
29Centring and shuttering including strutting, propping etc and removal of form work for : c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas(3.5 m height).
30Reinforcement of RCC work including bending, binding and placing in position complete b) Tar/TMT steel
31Providing and fixing T-iron frames for doors, windows and ventilators of MS Tee sections joints mitred and welded with 15 x 3 mm legs, 10 cm long embedded in cement concrete block 15 cm x 10 cm x 10 cm size of 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or bolt and nuts as required, including fixing of necessary butt hinges and screws and applying a priming coat of approved primer
32Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size).
33Providing and fixing T-iron frames for doors, windows and ventilators of MS Tee sections joints mitred and welded with 15 x 3 mm legs, 10 cm long embedded in cement concrete block 15 cm x 10 cm x 10 cm size of 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or bolt and nuts as required, including fixing of necessary butt hinges and screws and applying a priming coat of approved primer Z section
34Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
35Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. a) With 12 mm mild steel U beading
36Fixing of Door, windows / ventilators chaukhats in position.(a) Door Chaukhats
37(b) -d- Window chaukhats
38(c) -do- Ventilator chaukhats
3915 mm cement plaster 1 : 6 (1 cement : 6 fine sand) on the rough side of single or half brick wall
4012 mm cement plaster 1 : 6 (1 cement : 6 fine sand).
41Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
42Providing 75 mm thick 1st class brick drip course at junctions of roofs and walls in cement mortar 1:4 (1 cement : 4 fine sand).
43Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete
4425 mm thick cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with a floating coat of neat cement
45Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
46Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
47Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : a) 25 mm thick
48Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete
49Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
50Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS:15622 (thickness to be specified by the manufacturer)of approved make in all colours,shades except burgundy, bottle green,black of any size as approved by Engineer-in-charge in skirting,risers of steps and dados over 12 mm thick bed of cement Morter 1:3(1 cement:3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete
51Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red 18 mm thick (slab area upto 0.50 sqm)
52Providing and fixing flush door shutters, non-decorative type, core of black board construction with frame of 1st class hard wood and well matched commercial ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 40 mm thick including anodised aluminium butt hinges with necessary screws
53Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
54Providing & fixing stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16 mm
55P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. 300 mm x 10mm
56Providing & fixing stainless steel handles ISI marked anodised ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 125 mm
57Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade.
58Finishing walls with Acrylic Smooth exterior paint of required shade : (a) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
59Providing two coats of acrylic based wall putty over cement plaster/brick wall and ceiling both internal and external after removing all the loosely adhering materials from the wall/ceiling surface with the help of emery stone,putty blade or wire brush,moistering the wall with the help of sufficient quantity of clear water as specify and directed by the department.
60Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with : 4.0 mm thick glass panes sqm
61Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an evenshade.
62Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade
63Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound....
64Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete.
65Extra for providing and fixing glass strips in joints of terrazzo floor. a) 40 mm wide and 4 mm thick
66Providing and fixing flush door shutters, non-decorative type, core of black board construction with frame of 1st class hard wood and well matched commercial ply veneering with vertical grains or cross bands and face veneers on both faces of shutters b) 25 mm thick (for cupbaord) including nickel plated bright finished MS piano hinges with necessary screws.
67Pre-cast terrazzo tiles 20 mm thick with white, black or white and black marble chips of sizes up to 6 mm laid in floor, treads of steps and landings on 25 mm thick bed of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete with pre-cast tiles of : a) Light shade using white cement
68Supply and filling of cinder in Sunken portions of Toilets and roads as per direction of Enginee-in-charge including all cost of materials. Labour T & P etc. required for proper completion of work.
69Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includesreparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
70(C) INTERNAL WATER SUPPLY & SANITATION
71Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
72Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : a) W.C. pan with ISI marked white solid plastic seat and lid
73Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require (a)White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tappillar tap.
74Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink without drain board 610x510 mm bowl depth 200 mm
75Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.a) 32 mm dia for wash basin
76b) -d- 40 mm dia for lab sink
77Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : b) Rectangular shape 453x357 mm
78Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality). a) 750 x 20 mm size
79Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms
80Providing and Fixing C.P. brass Ablution health faucet assembly with 1.2 m long braided PVC hose with mounting bracket fixed on wall complete.[FOR EWC]
81Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to IS:8931. 15 mm nominal bore
82Providing 15 mm dia. inletC.P. brassProviding and Fixing C.P. Single flow overhead shower (With Arm)-ESSCO EOS-542A-125MMDIA
83Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.a) 110mm dia P.V.C. pipe
84b) -do- 90mm dia P.V.C. pipe
85Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 90mm
86Providing and fixingterminal guard.(a) 110 mm
87(b) -do- 90 mm
88Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.(a) 110mm bend
89(b) -do- 90 mm bend
90(c) -do- Coupler 110 mm
91(e) -do- Coupler 90 mm
92(f) -do- Single tee with door 90x90x90 mm
93(g) -do- Single tee with door 110x110x110 mm
94Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to15 mm nominal bore
95Providing and fixing clean out plug 110 mm dia.
96Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc.Exposed on wall a) 32 mm dia nominal bore (medium duty)
97Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.a) 20 mm dia nominal bore
98b) -do- 25 mm dia nominal bore (medium duty)
99Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.(a) 32 mm dia nominal bore.
100Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions.a) 15 mm nominal bore
101Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 a) 15 mm nominal bore
102Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.(a) 15 mm nominal bore
103Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931a) 15 mm nominal bore
104Providing and fixing non Return valve with wheel of approved quality.(a) 25 mm dia nominal bore
105(b) -do- 32 mm dia nominal bore
106Providing and fixing brass stop cock of approved quality.(a) 20 mm nominal bore
107Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Capacity 1000 litre
108Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.(a) 110 mm dia P.V.C. pipe
109b) -do- 90 mm dia P.V.C. pipe
110Providing and fixing square mouth S.W. Gully trap grade \"A\" complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 75 and water tight C.I. cover with frame of 300 x 300mm.size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design. a) 150 x 100 mm. size P type
111Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes (a) 110 mm diameter
112Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.(a) 110 mm
113Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.(a) 110 mm
114Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
115Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With FPS bricks of class designation 75 (i) For Sewer Line
116(ii) Extra for depth of man hole size 90x80 cm
117Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design.
118(D) SEPTIC TANK SIZE 5.0 M x 2.10 M x 3.0 M & SOAK PIT
119Earth work in excavation in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) including banking in 20 cm layers and breaking clods, ramming and dressing up for the purpose of making embankments or filling up ground depressions, lead upto 50 m and lift upto 1.50 m.(a) In all kind of soil upto 1.5 m depth
120(b) -do- In all kind of soil upto 1.5 m to 3.0m. depth
121(c) -do- In all kind of soil upto 3.0 m to 4.5m. depth
122Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
123Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand).
124Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishingand plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).Slab
125Centring and shuttering including strutting, propping etc and removal of form work for : c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas(3.5 m height).
126Reinforcement of RCC work including bending, binding and placing in position complete b) Tar/TMT steel
12715 mm cement plaster 1 : 6 (1 cement : 6 fine sand) on the rough side of single or half brick wall
12825 mm thick cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with a floating coat of neat cement
129Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar
130Providing and fixing S.C.I. Tee 150 mm at the inlet and outlet of septic tank.
131Providing and fixing soil, waste and vent pipes:75 mm diameter Sand cast iron S&S pipe as per IS: 1729
132Providing & fixing of 75mm dia Sand cast iron S&S as per IS - 1729 terminal guard.
133Providing & Fixing 75mm plane sand cast iron S&S bend of required degree.
134Providing lead caulked joints to sand cast iron/ cetrifugally cast (squn) irons pipes & fitting of 75 mm dia
135Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -10- Circular shape 500 mm internal diameter
136Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.
137(E) INTERNAL ELECTRIFICAL WORK
138Wiring for light point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.earth continuity wire and piano type switch etc. complete in all respects.
139Same as item No.(1) but for fanandlight duty exhaust fan.
140Same as item No.(1) but for5 Amp plug point with piano type switch and socket etc.
141Same as item No.(1) but forcall bell
142Supply and wiring of submain 2 number 2.5 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20 mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number2.5 Sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
143Supply and wiring of submain 2 number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number4 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
144Supply and wiring of submain 2 number 6 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 6.0 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
145Supply and wiring of submain with 4 number 10 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in32 mm dia heavy duty (2mm thick ) PVC conduitpartly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 6 sqmmearth contunity wire including colour wash etc. complete in all respects.4 X 10 sqmm
146Supply and wiring of submain with 4 number 16 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in32 mm dia heavy duty (2mm thick ) PVC conduitpartly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 6 sqmmearth contunity wire including colour wash etc. complete in all respects.(a) 4 X 16sqmm
147Supplyfixingand concealing of20mm dia. 2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work .( for Telephonepoints)
148Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.
149Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.
150S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work.
151Supplyfixingofelectronic fan regulator 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.
152Supply and fixing of 15 Watt to 18Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect.(corridor ceiling)CAT-A
153Supply & fixing of single wall light bracket made of brass on matching polished MDFEG boardbrassincludingconnectionetc. as required.
154Supply & fixing of Call Bell Of Approved Make on matching polishedMDFEG boardbrassincludingconnectionetc. as required.
155Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.k.63 A
156Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.k.100 A TPN
157Supply and fixing of flush/surface mounting distribution boards complete in all respects.6 Way TPN DOUBLE DOOR
158Supply and fixing of 240 volts \"L\" series miniature circuit breaker 6 Amp. To 32 Amp. (10 K A ) in existing MCB, DB complete with connections as required. 6 - 32 amps.
159Supply fixing and making connection of following FPMCBS complete in all respects as per direction and satisfaction of engineer-in-charge.(a) 40 Amp. 4 Pole MCB(10 KA)
160(b) do- 63 Amp. 4 Pole MCB(10 KA)
161Supply and fixing of power plug with 15A/250 V flush type switch and 3 Pin 15 A/250V flush type socket in suitable M.S. box of 175mmx100x50mm size Switch bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer.
162Supply & fixingof Sheet Steel Enclosure Surface/ Flush Mounting fitted With 20/32 Amp. 2 Pin and earth metal clad scraping earth plug and socket complete in allrespects as per direction and satisfaction of engineer-in-charge.
163Supply and fixing Single Pole MCBS Blanking Plate complete in all respects.
164Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15 mm dia G.I.pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects.
165Supplying & Laying of 25mmx5mm G.I. Strip for earthing purpose as required complete in all respects.
166Supply & fixing of two number 6 SWG G.I. wire for earthing purpose as required complete in all respects.
167Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1100 Volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size.as per direction of Engineer-Incharge.complete in all respect The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (a) 120 sqmm 3.5 core
168Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.2mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB\"s to be used. All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports.The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section.The minimum clearances between bus bars shall be as follows :Phase to phase - minimum 20mm.Phase to neutral-minimum 15mm.Main L.T. Panel -G.F.Incoming :One (1) No 300 Amp. 4 pole 1 NO.Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-300A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) Set of Phase Indication Lamp.Bus Bar :One (1) No. 300 Amp. TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.100 Amps TPN-1No.OR outgoing as per site requirment
169Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules.
170Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality.
171Providing & fixing of 3 Pin telephone outlet complete in all respect on existing board with connections as required.
172Providing, drawing, connecting and testing of telephone/invertorwire 2 pair 0.51 sqmm. tinned copper conductor PVC insulated in existing conduit from telephone outlet box to the junction box/tag block.
173Providing and Laying unplastisized rigid PVC pipe conforming to IS:13592 type A including jointing , cuttingand making good the walls & floors as per requirement.110 mm
174Supply and erection of AC 1200mm Sweep, 230/250 Volts, 50 Hz ceilling fan with regulater standar down rod, blades including connection etc. complete as required
175Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required.300 mm sweep.
176Supply and Fixing of LED bulb 10 watt
177Transportation of Engineering materials for main building and Septic tank etc
178(F) CONSTRUCTION OF APPROACH ROAD
179Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness by manual means (a) In area of light jungle
180Excavation for road way in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 metres (average lead 50 metres), including trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections.)
181Excavation for roadway in ordinary rock by deploying a dozer, 80 HP including cutting and pushing the cut earth to site of embankment upto a distance of 100 metres ( average lead 50 metres ), trimming bottom and side slopes in accordance with the requirements of lines, grades and cross sections.
182Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock,loading in tippers and disposal within all lifts and lead upto 1000 metres,trimming bottom and side slopes in accordance with requirements of lines,grades and cross sections.(By Manual means)
183(G) CONSTRUCTION OF C.C. PAVERS
184Preparation of sub grade by excavating earth to an average depth of 22.50 cm, dressing to camber and consolidating with road roller, making good the undulations etc. and disposal of surplus earth, lead upto 50 m.
185Consolidation of sub-grade with road roller of 8 to 12 tonne capacity including making good the undulations etc. with earth or quarry spoils etc. and rerolling the sub grade.
186Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1..
187Cement Concrete Pavement:-Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383..
188Transportation of Engineering materials for C.C.Pavers
189(H) CONSTRUCTION OF C.C. DRAIN
190Earth work in excavation in foundation trenches not exceeding 1.50 m width or 10 Sq.m.on plan or drains not exceeding 1.50 m in width or 10 Sq.m. on plan including dressing ofsides and ramming of bottoms, lift upto 1.50 m including getting out the excavated soiland disposal of surplus excavated soil as directed, within a lead of 50 m.(Hard Soil)
191Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
192Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone shingle 20 mm nominal size) excluding the cost of centring and shuttering in : Foundations and plinth
193Centring and shuttering including strutting proping etc. and removal of form work for:Wall
19412 mm cement plastering 1:3 ( 1 cement : 3 fine sand)
195Neat cement Punning in side of drain
196Transportation of Engineering materials for C.C. Drain

AI Tender Summary

OUR REF NO 48924436
AUTHORITY Government Departments
TENDER VALUE 24.05 Lakhs
LAST DATE 13-05-2025
Authority
Authority Name Public Health Engineering Department
Work Description construction of 6 Nos Type-Iv Quarters For Docters At Seijosa And Pakke Kessang
Basic Detail
Tender No EE/PHE/LMI/NIT/2024-25/05
Bidding Type Tender
Location
City Pakke Kessang
State Arunachal Pradesh
Key Dates
Publish Date 30 Apr 2025
Submission Date 13 May 2025
Open Date 13 May 2025
Finance
Tender Value 24.05 Lakhs
Tender Fee 5000
EMD 2.40 Lakhs
Exemption Available
Document List
BOQ_2714.xls
SBD.pdf
Tendernotice_1.pdf
6f094226-0ba6-499f-b6e5-e7008ed1024f.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 30, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
May 13, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 13, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2714.xls

pdf

SBD.pdf

pdf

Tendernotice_1.pdf

html

6f094226-0ba6-499f-b6e5-e7008ed1024f.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders