Tender For Re-Tiling Of Bed Space In New Ministerial Residence Number-01 Situated At Vikramaditya Marg, Splitting Of Bricks In The Rear Shed, Putting Pebbles Around The Hut Built In The Residence, Painting Of The Interior And Other Various Necessary Repair Works. - Dismantling Tile work in Floor and roof laid in cement mortar including stacking material within 50 meters lead. Forthickness of tiles 10 mm to 25 mm. DAR.N0-15.23.1, 2 Providing and laying Vitrified floor Size of Tile 600x1200 mm in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved Make, in all colours & shades, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing with grey Cement Slurry @ 3.3 kg/Sqm including grouting the joint with white cement and matching Pigments etc. Complete.. (DAR-11.41A.2.2) 3 Brick work with Common burnt clay F.P.S. (Non Modular ) bricks of Class designation 7.5 in Superstructure above plinth level up to floor V level in all shapes and size in Cement Mortar 1:4 Cement and Coarse sand in including Supply of all materials labour T& etc required for proper completion of work as per DAR.No-6.4.1, 4 Dismantling Old Plaster or SkirtingRacking out joint and cleaning the surface for plasterincluding disposal of rubbish to the dumping ground within 50 metars lead. DAR No-15.56, 5 12 mm thick Cement Plaster with Cement mortar in proportion of mix 1:4 (1 cement : 4 coarse sand). DAR-13.4.1, 6 Providing and Fixing 12 mm thick densified tegular edged eco friendly light weight false ceiling tiles (Armstrong Mineral Fiber Acoustical Suspended Ceiling with New Lotus RH 70 Board Tile 600x600x12 mm module) of approved texture spintone/cosmos / Hexa or equivalent in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main T runner suitably spaced at joints to get required length and of size 15x45 mm made from 0.30 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross T of size 15x45 mm made out of 0.30 mm (Minimum) sheet, 1200 mm long spaced between mainT at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross Tof length 600 mm and size-15x45 mm made of 0.30 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x19X3000 mm made of 0.27 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 19 mm thick densified edges ceiling tiles of approved texture (Spintone / Cosmos/ hexa) in the grid, including, cutting/ making.opening for services like diffusers, grills,light fittings, fixtures, smoke detectors etc., The False ceiling tile shall have NRC. value of 0.50(Minimum), light reflection > 85%, non - combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity<0.043 w/m 0 KC. The Tile & Grid system used together should carry a 15 year warrantee. 7 Providing and Fixing of glazing in Aluminium door/ window, Ventilator shutter and Partitions etc. with EPDM Rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium Snap beading shall be paid in basic item). with APC Sheet (Aluminium Power Coated Sheet) 8 Structual Steel work riveted bolted or welded in built up section, trusses, Builds up gates,framed work lncluding cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Sl.N0-10.2, ( 9 Providing CorrugatedG.S. Sheet roofing including Vertical /Curved Surface Fixed with polymer Coated J or L hooks, bolts and nuts 8 mm dia meter with bitumen and G.I. limpet washers filled with white Lead, including a Coat of approved Steel Primer and Two coats of approved Paint on Overlapping of Sheets Complete (UP to any Pitch in horizontal /Vertical or Curved Surface), excluding the Cost of Purlins, rafters andand trusses and including cutting to size and shape wherever required. (1.00 mm thick with Zinc Coating not less than 275 gm/m²) DAR N0-12.1.1, 10 Supply and Placing of Pebble Stone. Complete work as Per Direction of Engineer in Charge. 11 Providing and Fixing of aluminium work for doors, window, Ventilators and Partitions with extruded built up standard tubular sections appropriate Z sections and other sections of approved make conforming to IS:733 and ISl;1285, Fixing with dash fasteners of required dia and size, including necessary filling up the gape at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neorapan gascket etc. aluminium section shall be smooth rust free straight mistred and jointed machanically whrever required including clear angle, aluminium snap beading for glazing/Paneling, C.P. Brass/Stainless Steel Screws, all complete as per architectural Drawing and the directions of Engineer-in-charge. (Glazing, Paneling and dash fasteners to be Paid for Separately) (For Fixed Portion) Power coated Aluminium (minimum thickness of power Coating 50 micron)DAR-21.1.1.2. 12 Providing And Fixing Float Glass Panes 4.0 mm thick(Weight not less than 10.00 kg/Sqm), (DAR-9.7.7.1) 13 Providing and Applying white Cement based Putty of average thickness 1 mm. of approved brand and manufacture. Over the Plastered wall Surface to Prepare the Surface even and Smooth Complete. (DSR-13.80), 14 Wall Painting with Premium acrylic emulsion paint of Interior grade, having VOC (VolatileOrganic Compound) Content less than 50 grams/litre of approved brand and manufacture, lncluding applying additional coats wherever required, to achieve even shade and colour. One Coat, DSR.N0-13.83.1), 15 Providing and laying in Position Cement Concrete of l 1:5:10 (1 cement, 5 Coarse sand (Zone-lll) Derived from natural Sources : 10 graded Stone aggregate 40 mm nomical size Derived from natural Sources ) DAR N0-4.1.10, 16 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work sqm DSR No-13.99.1, 17 Providing and fixing Chlorinated Polyyinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plains & brass threated fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joints of pipe and fitting with one step CPVC solventcement and the cost of cuttings chases and making good the same including testing of joints complete as per direction of Engineer Incharge. concealed work. including cutting chases and making good the walls etc. (20mm nominal outer dia pipe )18.8.2, 18 Providing and Fixing of UV Stabilised Fiberglass reinforced Plastic Sheet Roofing up to any Pitch, including Fixing with Polymer Coated J or L hooks, bolts & nuts 8 mm dia, G.l. Plain/bitumen Washers Complete but excluding the Cost of Purlins, Rafters, Trusses etc. the Sheets shall be manufactured out of 2400 TEX Panel Roving Incorporating Minimum 0.3%, Ultra-Violet Stabiliser in resing system under approximately 2400 PSl and hot Cured. they Shall be of Uniform Pigmentation and thickness without air Pockets and shall Conform to IS 10192 and IS 12866. the Sheets Shall be Opaque or translucent, Clear or Pigmented Textured or Smooth as Specified. 2 mm thick Corrugated (2.5 or 4.2 or 6) or Step-Down (2 or 3 or 6 ) as Specified.DAR N0-12.47.1, 19 Disposal of building rubbish /malba /Similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. DAR No-15.60,