Tender For Interior And Its Allied Works At Kpl Registered Office At Jawahar Building On Percentage Rate Basis; 1 CIVIL WORKS 2 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres below and as per the site incharge direction. 3 Dismantling wooden boardings in lining of walls and partitions, including supporting members, stacking etc inlcuding lifting, transport, scaffolding, labour, tolls etc all complete within 50 metres lead :Thickness above 25 mm up to 40 mm sqm. - Wall panelling. 4 Dismantling of existing 2x2 grid false ceiling, gyp board ceiling with necessary support, stacking etc inlcuding lifting, transport, scaffolding, labour, tolls etc all complete within 100 metres leadas per the site incharge direction. 5 Dismantling of existing wooden flooring with skirting, stacking etc inlcuding lifting, transport, labour, tolls etc all complete within 100 metres leadas per the site incharge direction. 6 Dismantling tile work in floors and walls laid in cement mortar including stacking material etc inlcuding lifting, transport, labour, tolls etc all complete within 50 metres lead for thickness of tiles 10 mm to 25 mm sqm 7 Dismantling & refixing of existing Board room table (Veneer finish) in usable condition, stacking and transporting the materials from the site to the desired area as per the Site incharge instruction.- Table Size (2.1m x 6.5m) 8 Dismantling of 18 deep Laminated ply Storage along the walls including supporting members, stacking etc inlcuding lifting, transport, scaffolding, labour, tolls etc all complete within 50 metres lead : - 18 deep laminated ply storage from wall. 9 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) 10 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 5 in Superstructure above plinth level up to floor V level in cement mortar 1:4 (1 cement :4 coarse sand) 11 Providing & applying 12 mm thick cement plaster in CM 1:4 (1 part of cement: 4 parts of sand) to walls internally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces, scaffolding, rounding off or champhering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface,chiselling the undulated surface wherever necessary and curing, etc., all materials and labour complete in all respects including all lead, lift and descent andcomplete complying withspecifications and as instructed by the Engineer in charge. 12 Cement Plaster in crushed stone aggregate - 20mm cement plaster of mix 1:4 (1 part of cement: 4 parts of crushed stone aggregate) 13 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 14 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more 15 Providing and injecting chemical emulsion for Anti- Termite treatment by creating a chemical barrier around the wall trenches& along the external perimeter of the building, expansion joints if any , surrounding of pipe and conduits etc., using chemical emulsion as per manufacturers instruction, including drilling holes and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole. Cost shall include all material and labour, etc. (Plinth Area at Ground Floor level only shall be measured and paid for). complete as per manufacturers specification. Approved manufacturers : PCI, Godrej, Pidilite or approved equivalent. 16 Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.Note:- (1) The elevational area (i.e.face area) of the scaffolding shall only be measured for payment purpose. The inner grids will not be measured for payment. (2) The payment will be made once only for execution of all items for such works . 17 Disposing of all unservicable items like demoilsed tile, brickworks, concrete and other debris away from the site for a lead of 10 KM as perdirection of Engineer-in-charge mentioned in Item no.20 to 80. (Eicher van/ Equivalent) 18 Water Proofing Treatment in Terrace:Providing and laying integral cement based water proofing treatment including prepatation of surface as required for treatment of roofs, balconies , terraces etc, consisting of following operations. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water -proofing compound confirming to IS 2645 including cleaning the surface before treatment, (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabsand as directed by Engineer-In-Charge including all labour, materials ,tools etc., all complete (c) After two days of proper curing applying a secound coat of cement slurry admixed with proprietary water proofing compound conforming to IS : 2645. Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test, All above operations to be done in order and as directed and and as directed by Engineer-In-Charge including all labour, materials ,tools etc., all complete With average thickness of 120 mm and minimum thickness at khurras point. 19 GROUTING & WATER PROOFING -EXTERNAL WALLS:a) Identifying the week areas on the surafce, joints, crack set and drilling holes of 10mm dia, fixing PVC nozzle with polymer mortar in the drilled holes. b) Water proofing in Terrace- Cleaning the surface area with wire brush and water wash apply the brushbond roof guard is high build fibre reinforced seamless waterproofing render suitable for waterproofing of old and new roofs, it is a polymer base product applied in terrace surface area with two coats. c) he Identified Area is Clean and Free of Dust and other particles, etc,. Reinforcing steel must be primed with Nitozinc Primer immediately after cleaning. All surfaces including edges must be primed. 20 Trimming & cutting of Trees and its branches inside the KPL office premises with required labours & tree cutting equipments including cutting, shifting, transpoting & disposing of all wastes as directed by the Site incharge. 21 FLOORING 22 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of requiredthickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 1200 mm OR 200X1200 mm(Basic cost of Tile - Rs.950/Sq.m) 23 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 1200 mm OR 200X1200 mm (Basic cost of Tile - Rs.950/Sq.m) 24 PARTITION 25 Providing and fixing 85mm thk Full Height Veneer finished Marine BWP Plywood Partitions using 25 x 50mm anodised aluminum section framework @ 600 c/c bothways with horizontal noggings at floor and soffit, both side skinning with 12mm thick veneer finished Marine BWP Plywood All electrical/network switch boxes, niches to be boxed/packed with adequate reinforcement using PLYwood. The aluminium channel to be provided at intersection of two materials. The partition may have veneer finished PLY Jamb lining all around. Complete as per drawing and directions. The veneer should be of teak or equivalent ( Basic cost of veneer - Rs.80)Both side Veneer finished partition - 0 to 3 mtrs Height. 26 Providing and fixing 85 mm thk Full Height Laminate finished Marine BWP Plywood Partitions using 25 x 50mm anodised aluminum section framework @ 600 c/c bothways with horizontal noggings at floor and soffit, both side skinning with 12mm thick veneer finished Marine BWP Plywood. All electrical/network switch boxes, niches to be boxed/packed with adequate reinforcement using PLYwood. The aluminium channel to be provided at intersection of two materials. The partition may have laminate finished PLY Jamb lining all around. Complete as per drawing and directions. ( Basic cost of Laminate - Rs.55)Both side Laminate finished partition- 0 to 3 mtrs Height. 27 FALSE CEILING 28 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) 29 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge with 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6 sqm ) 30 DOORS & WINDOWS 31 Providing andfixing of WOODEN ACOUSTIC DOOR: – 55mm to 76mm thick sandwich type composite sound reducing flush door shutters. The combined assembly set of door frame and door shutters to be as per following details:(a) Door frame shall be of teak / hard wood of size – 110 mm X 100 mm, including making necessary grooves in the frame for fixing of hollow bulb type EDPM gaskets on rebates to block noise leakage from gap in between door frame and shutter.(b) The frame of shutter shall be made from 40 mm thick teak / hard wood stiles and top & bottom rails of size 94 mm and core made of lock rail 100 mm wide and 40 mm thick and three additional strips 50 mm wide and 25 mm thick (minimum) (c) The core of door shutter shall be filled with acoustic insulation material , sound absorbing and damping material.(d) Face panels shall be of 12 mm thick Marine ply boards of approved make conforming to relevant IS codes / International Standards on both sides of the core of the shutter with required primer at the unexposed surface . One side of ply board shall be fixed to the core of the shutter along with a 5 mm thick Neoprene rubber sheet on its inner face.(e) 01 mm mica OR 04 mm thick Teak Veneer of approved make shall be bonded with 12 mm thick marine plyboard on both face of shutter by using high strength cross linked PVAC based adhesive.(f) Dropdown Seal: – Excellent quality range of Internal Automatic Dropdown Seal, which are manufactured from high grade quality raw materials. These Internal Automatic Dropdown Seal can be customized as per our precious customers specifications. These Internal Automatic Dropdown Seal are widely known for its durability and quality. Internal Automatic Dropdown Seal can be availed at industrial leading price. Resists sound upto 37db, air, insects, cold smoke, light. Designed for timber (wooden) doors.(g) Hardware- The door assembly shall be fixed to the door frame with heavy duty stainless steel hardware i.e. Door Lock, SS Bal bearing Hinges , SS door handle ‘D’ type back to back, SS Tower boltBoth side Veneer finished door of size 750 x 2100mm. 32 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. 33 Aluminium Doors/ Windows/ VentilatorsSupply , Fabrication and Installation of Anodized Aluminium (AC15 Grade) hollow section of approved size for Sliding Doors/ Windows/ Ventilators including beading Clips, Cleats + Wastages etc., and also including cost of all labour, materials, plant and machinery, transportation etc.,. complete all as per material specification mentioned in the Technical Bid and direction of Engineer-in-charge. 34 Applying Weather/structural non sag elastomeric PU sealant (600ml Sausage) for joints in RCC/ Brick/ Stone/ wood/ Ceramic/ Gypsum/ Alluminium work complying to ASTM C920, DIN 18540-F & ISO 11600 35 PAINTING 36 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. where ever required and as directed by Engineer-In-Charge including all labour, materials ,tools etc., all complete 37 Applying priming coats with primer of approved brand andmanufacture, having low VOC (Volatile Organic Compound ) content with water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. 38 Providing and applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content with ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre . 39 Applying priming coat with ready mixed red oxide zinc chromate primer including second coat of approved brand and manufacture on steel galvanised iron/steel works where ever required and as directed by Engineer-In-Charge including all labour, materials ,tools etc., all complete 40 ApplyingWall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.(Two coats) and where ever required and as directed by Engineer-In-Charge including all labour, materials ,tools etc., all complete 41 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture and as directed by Engineer-In-Charge including all labour, materials ,tools etc., all complete. 42 Providing and applying white washing with lime even shade three coats in wall surface and where ever required and as directed by Engineer-In-Charge including all labour, materials ,tools etc., all complete 43 Removing existing white or colour wash by scrapping and sand papering and preparing the ceiling, external & internal wall surface, steel surface, grills etc., smooth including necessary repairs to scratches and removing the unwanted materails from the surfaces including all labour tools, materails etc., etc. complete. 44 Applying wall painting with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 45 Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface again fine wet rubbed smooth, which is further allowedto dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. - PARITION & DOORS 46 FURNITURE 47 Providing and erection of High back Chair with pneumaticlift and tilting mechanisum and it should have Adjustable arm rest and Nylon basefrom approved Manufacture as per the approval. - MD Chair(Basic Cost - Rs. 25000) 48 Providing and erection of Medium back Chair with pneumaticlift and tilting mechanisum and it should have Adjustable arm rest and Nylon basefrom approved Manufacture as per the approval. (Basic Cost - Rs. 10000) 49 Providing and erection of Visitors Chair with pneumaticlift and tilting mechanisum and it should have Adjustable arm rest and Nylon basefrom approved Manufacture as per the approval. (Basic Cost - Rs. 7500) 50 Providing, fitting & fixing of 3 Seater Half leather Sofa set from GODREJ or EQUIVALENT MAKE as approved & directed by the site incharge. (Basic cost - Rs.30000) 51 Providing, fitting & fixing of Center table from GODREJ or EQUIVALENT MAKE as approved & directed by the site incharge. (Basic cost - Rs. 9000) - LIVING 52 Providing, fitting & fixing of Corner table from GODREJ or EQUIVALENT MAKE as approved & directed by the site incharge. (Basic cost - Rs.6000) - LIVING 53 Providing & Fixing of Workstation Table of size: 1200x600x750 HT using 19mm thk PLY finished with 4mm thk Veneer panel on exposed surface and 0.8mm laminate on other surfaces.The table top & the vertical modesty panel should be of 19mm thk BWP Marine plywood finished with Veneer. The table should have a pedestal storage of size 400X525X700MMhaving3 drawers unit with telescopic channel, 150mm handle and multipurpose lock with Castors. The handle for the shutters should be of Stainless steel or white metal handle in Brushed SS Finish of minimum 150mm high. The table should have a metal key board tray with mouse pad and a metal CPU Trolley with castors as per standards. All others to be completed as per the drawing & instruction from the Site Incharge. 54 Providing & Fixing of Workstation Table of size: 1500x750x750 HT with side unit of size 1050 x 450 x 705 using 19mm thk BWP Marine Plywood finished with laminated on all sides. The table top and the vertical modesty panel should be of 19mm thk BWP Marine plywood finished with laminate. Model - Godrej Finness Table with Eru, Make - Godrej 55 Supplying and installation of Anutone / Topakustiks / Idea Tec / Wood Fit / Equivalent Brand of Acoustic Wooden Wall Panelling with fire retardant grade pine wood fibre slats of size 2430 x 128 x 16mm with lineal perforation of 2mm back lined with soundtex black acoustical fleece 0.27mm thick, 63 g / m2, tongue-groove edge for a seamless look, 5 test fire retardant grade with noise reduction coefficient not less than 0.75 NRC to absorb low and mid range frequencies from 125Hz to 4000Hz. GI strut CC50 frame work not more than 60 cm centre to centre using GI channels are fixed on the wall, over which an acoustic filling polywool material sound synth of 500 gsm density of 50mm thick has fixed and finally the panels are fixed and finished, so as to have an neat appearance as directed by the departmental offices. The cost includes cost of material, cost of Labours, scaffolding, transportation, conveyance, etc., complete complying to standard specication. - Rafters 56 Supplyand installationofAnutone/Tectum/Heradesign/ Equivalent Brandof Acoustical SlimWall Panellingof synth slim, polyfibrepanels, core-pigmented, high-density, Synth PF rigidpanels of size1200x2400x9mmthick, volume density210-230kg/m3,weight1.9-2.1kg/m2installedby usingGIstrut frameworksystem. TheGIstrut framework systems includes GI strut CC 50 cross channel having thickness 0.7mm, length3600mm, knurledweb50, depth 25mmandequal flanges15mmisfastenedtowallpositioned horizontallyinaregularmannerat600mmcentretocentre. Anutone (or) Equivalent Brand of strand, square edge, magnesitebondedpinewood fibre core tiles of size600x 2400x10mm, density400kgs /m3,weight8kg/m2are fastenedtostrutCC50crosschannelwithsuitablefasteners. Longer edgesof thepanel shouldbeperpendicular tostrut CC50crosschannel. Synthslimpanelsarethenadheredto strand behind with stick S7 adhesive. The system is backlinedwiththeacoustical infillSynthPF500gsm50thick. Thesystems toachievenoise reductioncoefficient not less than0.85NRC,soastohaveanneatappearanceasdirected by the department offices. The cost includes, cost of material, cost of labour, scaffolding, transportation, conveyance, etc., complying to standard specication. 57 Supplying and fixing the Wall Panelling with the following specification fixing horizontally and vertically in position of wall. Fixing the water proof ply wood 9mm thick board over the country wood planks. The rate inclusive of all materials, labour power and conveyance of materials to the work site, loading & unloading etc., and as per drawing and design by the Departmetnal Officers. The water proof ply wood & other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.- 3 thk ply Wall panelling 58 Supplying and fixing the Wall Panelling with the following specification fixing horizontally and vertically in position of wall. Fixing the water proof ply wood 9mm thick board over the country wood planks. Over the ply wood OST sheet of 4mm thick will be fixed with necessary screws and fevicol giving neat finsih. The top will be finished with two coats of sanding polishing. The surface will be finished with necessary design as directed by the Departmental Officers. The rate inclusive of all materials, labour power and conveyance of materials to the work site, loading & unloading etc., and as per drawing and design by the Departmetnal Officers. The water proof ply wood and OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.( Basic cost of OST - Rs.80)- 3 thk Veneer ply Wall panelling 59 Supplying and fixing of 75mm to 100mm deep Veneer Jamb lining with the water proof ply wood of 18mm thick board over the ply dummy sides with 75x12mm thk ply board Architrave on all sides. Over the ply wood OST sheet of 4mm thick will be fixed with necessary screws and fevicol giving neat finsih. The top will be finished with two coats of sanding polishing. The surface will be finished with necessary design as directed by the Departmental Officers. The rate inclusive of all materials, labour power and conveyance of materials to the work site, loading & unloading etc., and as per drawing and design by the Departmetnal Officers. The water proof ply wood and OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification - 75mm to 100mm deep Veneer Jamb lining. 60 Providing andfixing of300mm deep OVERHEAD STORAGE UNIT using 19mm PLYfinished with 1mm thk Laminate outside and .8mm thk laminate inside. the storage unit with openable shutters and to be fixed by Hinges.The intermediate shelvesto be of 19mm PLY. The shutters shall be finished with 1mm thk Laminate outside and .8mm thk laminate inside & the edges to be finished with 1st quality teak wood beading all around with necessary polish. The handle for the shutters should be of Stainless steel or white metal handle in Brushed SS Finish of minimum 150mm high. All Hardwares like hinges, lock & drawer channels should be from EBCO or approved. All others to be completed as per the drawing. - WORKSTATION 61 MISCELLANEOUS 62 Providing and fixing of silhouette Blinds made of 38mmx38mm aluminium extruded top rail with powder coated finished enabled with control Mechanism to be louvolite and chain must be metal. Stops to be fitted top & bottom to eliminate over-run and it should have straight edge finish. The blinds should be of approved manufactures and complete as per the approved shade and texture.( Basic cost Rs 500/-) 63 Providing and fixing of Roller Blinds made of 38mmx38mm aluminium extruded top rail with powder coated finished enabled with control Mechanism to be louvolite and chain must be metal. Stops to be fitted top & bottom to eliminate over-run and it should have straight edge finish. The blinds should be of approved manufactures and complete as per the approved shade and texture.( Basic cost Rs 200/-) 64 Sun control film : Removing, cleaning of existing sun control film & Supplying, fixing Sun Control Film from 3M Suncontrol film Night vision 15 with 75% solar energy reduction of approved quality having size 3.8 micron thickness and fixing over plain glass in the Aluminium Window including cost of labour, material, equipments, machinery, transportation, loading and unloading, etc.,. complete as per material specification mentioned in the Technical Bid and direction of Engineer-in-charge. - 3M Make 65 Providing and fixing of Sliding Mosquito Screen: Aluminium extruded from first melting, 6063 alloy with Powder Coatings of approved colour withPlastics components of nylon 6. Below are the specifications: Weather-stripping: 100% PolypropyleneScreen Material: Stainless steel 304-grade Colour: Black PVC Coated. Sliding Profile - 50x18mm, Midbar Profile - 35x18mm, Bottom Track Profile - 62x31mm & Side & Top Profile - 62x31mm. 66 ELECTRICAL WORKS 67 LIGHTPOINT WIRING INPVC CONDUITWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group A 68 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independentswitch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit,and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. - Group A 69 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way modular switch, modularplate ,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 70 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 71 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 72 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 73 2 X 4 sq. mm + 1 X4 sq. mm earth wire 74 2 X 6 sq. mm + 1 X6 sq. mm earth wire 75 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 76 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required 77 Supplying and fixing following ways, Surface / Recess Mounting Vertical type 415V TPN MCBdistribution board,Sheet Steel Dust ProtectedDuly Power Painted inclusive of 200Amps tinned copper Buspar ,Common Netural link , Earth bar , Din Bar for Mounting MCB (But With Out As MCB and Incomer ) as required Note : verticalType MCB TPDBis normallyused where 3 Phase Outlets Are Required - 4 way (4 + 18), Double door 78 Supplying and fixing following way,single pole and neutral,sheet steel,MCB distributionboard, 240 V,on surface/ recess,complete withtinnedcopperbusbar,neutralbus bar,earthbar,dinbar, interconnections,powder painted including earthing etc.as required. (But without MCB/RCCB/lsolator) - For 16 way Douple Door SPN MCB DB 79 Supplying and fixing following rating, four pole, (Single and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.- 63 AMCB 80 Supplying and fixing following rating, four pole, (three phaseand neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 81 63 A 82 100A 4P MCB 83 Supplying and fixing TP sheet steelenclosure on surface/recess along with63A 415VC curveTPMCB completewith connections, testing and commissioning etc. as required. 84 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 85 Single pole 86 Triple Pole & netural 87 Supplying and fixing single pole blanking plate in theexisting MCB DB complete etc. as required. 88 POWER SOCKETSupplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required 89 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 90 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 91 Supplying and fixing 20 A, 240 V, SPN Industrial typesocket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 92 Supplying and fixing 20 A, 415 V, TPN Industrial typesocket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, 4P, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 93 Supplying and fixing 30 A, 415 V, TPN Industrial typesocket outlet, with 2 pole and earth, metal enclosed plug top alongwith 30 A C curve, 4P, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 94 UPS WIRINGWiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 95 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 96 1 or 2 Module (75mmX75mm 97 3 Module (100mmX75mm) 98 6 Module (200mmX75mm 99 8 Module (125mmX125mm 100 Supplying and fixing following modular base & cover Plate on Existing modular metal Boxes etc as required 101 1 or 2 Module 102 3 Module 103 6 Module 104 8 Module 105 Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc. as required. 106 5/6 A switch 107 15/16 A switch 108 3 pin 5/6 A socket outlet 109 6 pin 15/16 A socket outlet 110 Supply, Fixing, Testing and Commissioning Ofof Pop - up box for Conferranceroom tables. 6A Universal socket - 2 Nos (with switch control),HDMI port - 1 No,USB 2.0 / 3.0 port - 1 No,USB Type C - 1 No,RJ 45 - 2+1 Nos (Cat 6 + Cat 6A),VGA Port - 1No for the socket out let and complete with connections, testing and commissioning etc. as required. 111 LIGHT FITTING ANDFAN Supply, Testing&CommissioningofLEDRecessedFullGlow(2X2) Luminaire with a nominal system lumen output of 3600 Lumens (130Lm/W) and a Luminaire Wattage should not exceed 48W with Electronic driver. Also Operatingvoltageof140-270Vwithcutoffandautorestartfeature@325V. Power factor should be >0.95 & THD should be <10% & CRI>80. Color temperature–6500K.LEDLifeshouldbe50,000Hrs.Theluminairehousing shouldbemadeofpowdercoatedmetallicCRCAwithhighefficiencyPMMA diffuser.Make : BAJAJ,SKYLUX GLADDEN , Model No :BZRSQL 48L LED GX WH 112 COB based recessed with trim directional downlight, Jupiter, system power: 3 W, Luminous flux of luminaire 1200 lm, Colour temperature of 5700 K, cool white, CRI > 80, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours; energy-efficient LED, direct light emission, housing in die-cast aluminiumwith adjustable luminaire part, Polyester powder white coloured coat applied over a 5-stagepre-treatment ceiling trim, Clear cover with reflector and a beam angle of 38°, ZHLS (ZERO HALOGEN LOW SMOKE) wiring, Electronic control gear, Protection class II, IP 20, (Garnet 3W COB Spotlight) Cutout-60mm 113 COB based recessed with trim directional downlight, Jupiter, system power: 9 W, Luminous flux of luminaire 1200 lm, Colour temperature of 5700 K, cool white, CRI > 80, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours; energy-efficient LED, direct light emission, housing in die-cast aluminiumwith adjustable luminaire part, Polyester powder white coloured coat applied over a 5-stagepre-treatment ceiling trim, Clear cover with reflector and a beam angle of 38°, ZHLS (ZERO HALOGEN LOW SMOKE) wiring, Electronic control gear, Protection class II, IP 20, (Garnet 9W COB Spotlight)Cutout-65mm 114 Similar to recessed mounted type flexi strip 14W / mtr with controller for every 5mts. Rate shall be inclusive of necessary soldering work to be done for completing the work. 115 Supply,Installation, Testing and Commisioining ofCeiling Profile Ligth Type TruGroove, Installation/mounting type Recessed, Color Temperature Tc (K) 3000 / 3500 / 4000 Housing (Material And Finish)3/4 to 2 thick Extruded thickaluminum trim/Section and die-cast endplates,System Wattage 20W, Classifications (IP/IK) IP20, Cover (Glass/ PC) Poly carbonate, Electrical Class II,/ LED Lamps 240Nos/Mtr (LM26) 5 mtr roll with LED Driver lumens Including cost of 3/4 to 2 thick Aluminum Channel Accessories complete as required (Make IP Mac, Sanspa, Helius, ) 116 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required 117 EARTHINGSupplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) and as per technical specification and as per latest IS / IEC 118 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required and as per technical specification and as per latest IS / IEC 119 RACEWAY / CABLE TRAYSSupplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness 120 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 200 mm width X 50 mm depth X 1.6 mm thickness 121 Supply and Laying of 100 x 45mm Aluminium truncking box of 1.6mm thick and should be earthed with 14 SWG bare copper wire and bond firmly to thejunction box with hardware as required. Areas where the hollow portion of two raceway meets, both ends have to be connected with 14 SWG earth wire to maintain continuity.Intersecting points also to be connected through junction boxes. 122 Necessary cutting chipping works for laying the above raceway including closing the same with strong plastering work.Places where 3 or more raceways are laid they shall be bound firmly with chicken mesh &masonry work done before making the floor strong, smooth finish & in level with the level. Charges to be inclusive of disposingbroken rubble as instructed. 123 MISCELLANEOUS WORKSRemoving & Reinstallation of existing smoke detectorin the existing room will be placed as per present ceiling as per site condition with all required accessories. 124 Removing & Reinstallation of existing Camerain the existing room will be placed as per present ceiling as per site condition with all required accessories. 125 Removing & Reinstallation of Bio Metric Switchin the existing room will be placed as per present Wall as per site condition with all required accessories. 126 Removingof existing Switch Board , and 6Amps Socket,in the existing roomas per site condition with all required accessories. 127 Removingof existing Switch Board , and 16Amps Socket, in the existing roomas per site condition with all required accessories. 128 Removingof existingData & Voice Socket, in the existing roomas per site condition with all required accessories. 129 Removingof existing Wiring ( Lighting,Power,Data & Voice Cable , Ac Wiring)in the existing roomas per site condition with all required accessories. 130 Removingof existing light Fitting ( 2 x2 led light, spot light,Wall Light,Tube light )in the existing roomas per site condition with all required accessories. 131 Removingof existing Split Ac Unit of Indoor and Outdoor MS Stand, Copper Pipe , Drain Pipe Shiting To other Placein the existing roomas per site condition with all required accessories. 132 FIRE DETECTION AND ALARM SYSTEM 133 Supplying,installation,testing & commissioning of intelligent analog addressable photothermal detectorcompletewith mounting base complete as required 134 Supplying,installation,testing& commissioningof response indicatoronsurface/recessed MSBoxhavingtwoLED, metallic cover complete withallconnections etc as required 135 Supplying,installation,testing & commisssioningof intelligent addressableprogrammablesounder complete as required. 136 Supplying, installation, testing &commissioning offault isolator complete withbase as required. 137 Supplying,installation, testing& commissioning of intelligent addressablethermaldetector withrateof rise cumfixed tempreaturethermistorcomplete withbase as required. 138 Supplying,installation,testing& commissioningof addressablefire controlmodule complete as required. 139 CABLING WORKSSupplying&laying of2x1 .5sqmmfiresurvival armouredcable, 600/1 000V ratedwithannealed copper conductorhaving glass mica firebarriertapecoveredbyanextrudedlayerofCross Linkable EthylenePropylene Rubber (EPR) insulation and LSZH inner bedding, steelwirearmouring&LSZHoutersheathcompleteas required. 140 CCTV WORKS 141 Supply, laying, testing and commissioning for cat-6 4pair Networking cable for CCTV Camerasincluding termination and crimping through 25mm PVC conduit 142 Supply and fixing ofIP cosmic/dome camera 20 mt2 Mega Pixel HD Camera Make CP Plus/Secureye / D -Link/Matrix/Hikvision 143 CONFERENCE WIRING SYSTEM 144 Supplying installing testing andcommissioning of 30 watt wall Speakerincluding of with necessary works etc. 145 Supplying installing testing andcommissioning of Ceiling Speaker 20W including of with necessary works etc. 146 Supplying installing testing andcommissioning of 240 watt Mixer Amplifier PLE-1ME240-2IN including of with necessary works etc. 147 Supplying installing testing andcommissioningof Cordless Mic UHF- CCSE-CMLincluding of with necessary works etc. 148 Installing testing andcommissioning of existing Ceiling Speaker including of with necessary works etc. 149 Installing testing andcommissioning of 240 watt Mixer Amplifier PLE-1ME240-2IN including of with necessary works etc. 150 Installing testing andcommissioningof Cordless Mic UHF- CCSE-CMLincluding of with necessary works etc. 151 Supplying installing testing andcommissioning ofCG Connectors & Sockets 152 Supply,laying testing and commissioning of of 2 Core flexible Cable PVC insulated with rigid PVC conduit Pipe open / concealed typeand with all necessaries. 153 Supply,laying testing and commissioning of of 8 Core shielded conference cable PVC insulated with rigid PVC conduit Pipe open / concealed typeand with all necessaries. 154 PROJECTOR AND MOTORIZED SCREENSYSTEM 155 Supplying installing testing andcommissioning of 3 feet ceilling Mount kit including of with necessary works et 156 Supply,laying testing and commissioning of 20 Metre HDMI CableRigid PVC conduit Pipe open / concealed typeand with all necessaries. 157 Supply,laying testing and commissioning of 3core 1.5 sq.mmPVC power Cable projectorRigid PVC conduit Pipe open / concealed typeand with all necessaries. 158 Installing testing andcommissioning of Existing Conference System With Monitor,Speaker,and Equlizerwith necessary works etc. 159 DATA & VOICE WORKS 160 DATA / VOICE / TELEPHONE CABLE Supply and laying of UTP 4 pair CAT 6telephonecable telecom box to EPABX system withs uitable PVC conduit pipe with all necessary fixing accessories, arrangements and etc.Cost include all bends, clamps, screws, junctions, clippings and concealed or open in manner slab / wall / partitions and etc.Cost include tools, lead, lift, loading, unloading charges, cutting, transport, labour charges, wastages and etc. Cost include tiles floor cutting with special tools & without damage the tiles for to laid the telephone cabling work,filling with cement mortar, packing, refinish with existing removed tile swith cement mortar,cements lurry and white cement pointing with colouring pigment.Cost include removal of the existing wirings and conduits.Make of 2pairwires- POLYCAB, ANCHOR, FINOLEX & ORBIT. 161 Supply, Installation, Testing and Commisioing of Modular type 1Nos of RJ11 in PVCsurfacebox with suitable Face plate fixing the same in the wall /partitions with all necessary fixing accessories, arrangements and etc.Cost include removal of the existing RJ11. Make of RJ11-ANCHOR ROMA. 162 Supply and laying of 20pair telephone cable krone connector to EPABX system with suitable PVC conduit pipe with all necessary fixing accessories, arrangements and etc.Cost include all bends, clamps, screws, junctions, clippings and concealed or open inmanner slab /wall /partitions and etc. Cost include tools, lead, lift, loading, unloading charges, cutting, transport, labourcharges,wastages and etc.Cost include removal of the existing wirings and conduits.Make of the cable- POLYCAB, ANCHOR, FINOLEX & ORBIT 163 Supply and Fixing of 20 pair krone connector with enclosure with all necessary fixing accessories, arrangements and etc.Cost include fixing all hardwares and accessories.Cost include removal of the existing krone connetor. 164 Supplying and fixing E-CAT6 cable with PVC conduit pipe from server to each computers including proper termination and marking with tags with all necessary fixing accessories, arrangementsand etc.Cost include all bends, clamps, screws, junctions, clippings and concealed or open in manner slab / wall /partitions and etc.Cost include tools, lead, lift, loading, unloading charges, cutting, transport, labour charges, wastages and etc.Cost include tiles floor cutting with special tools & without damage the tiles for to laid the data cabling work, filling with cementmortar, packing, refinish with existing removed tiles with cementmortar, cements lurry and white cement pointing with colouring pigment.Cost include removal of the existing wirings and conduits. Make of Cat-6 cable- D-LINK. 165 Supplying and fixing RJ 45 I/O with metal or plastic surface mounting face plate with all necessary fixing accessories, arrangements and etc.Cost include all accessories like tools, lead,lift,loading, unloading charges, cutting, transport, labourcharges, wastages and etc.Cost include removal of the existing RJ45.Make of RJ45-D-LINK/AMP/MOLEX. ( SINGLE PLATE ) 166 Supplying and fixing RJ 45 I/O with metal or plastic surface mounting face plate with all necessary fixing accessories, arrangements and etc.Cost include all accessories like tools, lead,lift,loading, unloading charges, cutting, transport, labourcharges, wastages and etc.Cost include removal of the existing RJ45.Make of RJ45-RJ45-D-LINK/AMP/MOLEX. ( DOUPLE PLATE ) 167 Supplying and fixing RJ45 mounting cord length of 7feet.Costincludeall accessories. Make of Cat-6 mounting cord 168 Supplying and fixing RJ45 mounting cord length of 3 feet.Cost include all accessories. Make of Cat-6 mounting cord 169 Supplying and fixing of 16 port jack panel .Cost include all accessories. 170 Supplying and fixing of 16 port switch 10/100 Mbps including connections. 171 Supplying and fixing 12U closed rack with locking arrangement.Cost include all accessories. 172 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 173 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 174 25 mm 175 32 mm 176 HVAC WORKS - BOARD ROOM 177 CASSETTE ACUNITSupplying, fixing , Testing and Commissioning of 3.5 TRAir Conditioner 5 star rated-Copper Condenser Coil Capacity, With an S-UTR Compressor Cassette type unit including installation, gas filling along with cutting the holes in the walls for drain pipes including providing and fixing 25mm dia PVC drain pipe and adequate copper pipe for a standard length of 3 metres along with powder coated supports.( Make :voltas / carrier / blue star / Samsung ) 178 Providing structural supports for the outdoor units. The support shall be standard bracket and not to be fabricated at site. The unit shall also NOT rest on sunshade or roof slab.3.5TR Cassette Unit 179 Supply and erection of soft copper refrigeration pipe complete with bends, elbows, supports, insulation for suction line etc..3.5TR Cassette Unit 180 Supply and laying of power and control cabling from the MCCB (provided by the electrical agency near the indoor units) to the indoor and outdoor units. The power wiring to the compressor motor, condenser fan motors and the evaporator fan motor shall be with suitably rated copper conductors taken within PVC conduit pipes. The earthing to the motors shall be with 6 SWG copper rod. 1.5/1 TR Hi wallunits: 181 Supply and laying of drain piping of PVC from the indoor unit to the nearest drain with 25mm Hard PVC pipe 182 HVAC WORKS - MD ROOM 183 Supply of 2.0 TR SPLIT AC UNIT - 5 STAR RATEDinverter technology split air conditioner with full function wireless remote and auto restart feature, with indoor/outdoor unit, gas charge, Copper condenser coils and Copper cooling coils company provided copper refrigerant pipe complete in all respects.Acceptable makes AC: Carrier, Toshiba, Daikin, O General, Hittachi, Mitshubishi, Voltas, Blue Star 184 Supplying, fixing , Testing and Commissioningfor including installation of 5KVA wall mounted stablizer forsplit units Controlwith necessaryWorks etc….. 185 Supplying, fixing , Testing and Commissioningfor providing additional copper pipes (5/8 and 3/8copper pipe one circuit) for the above split units with necessary insulation and with adequate pvc insulated copper wire from indoor to outdoor units concealed and taken through beyond the standard 3m length. 186 Supplying, fixing , Testing and Commissioningfor providing additional 25mm dia PVC drain pipeconcealed and taken through wall/ partition beyond the standard 3m length for the above split units. 187 Supplying, fixing , Testing and Commissioningstandard powder coated support brackets for the above split units including fasteners and other accessories as required.