| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.i) Group B |
| 2 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.: 2 x 1.5 Sq mm + 1 x 1.5 Sq mm earth wire. |
| 4 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. |
| 5 | Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. |
| 6 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc. as required. |
| 7 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)(i) 8 way , Double door |
| 8 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator (ii) 6way , Double door |
| 9 | Supplying and fixing 5 amps to 32 amps rating, 240 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 10 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required (i) 40 Amps |
| 11 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required |
| 12 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 13 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 14 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 15 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 16 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 17 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
| 18 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
| 19 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 20 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40 mm |
| 21 | Supplying and fixing PVC batten/ angle holder including connections etc. as required |
| 22 | Supplying and fixing of12 Watt round Slim surface mounted LED panelPDC aluminium housing type fitting on ceiling with all accessories i.e ready to use (Make Havells-code- LHEAABP7IL1W012 or its equivalent of CG/ Bajaj/ Philips) |
| 23 | Supplying, installation, testing & commissioning of 10 watt LED bulkhead fittingsuitable for outdoor applications with IP 65 protection complete with all accessories ready to use as required. (Make-CG/BAJAJ/Havells/Philipscompitable to CG model no. LBHE-10-CDL. |
| 24 | Supplying, installation, testing & commissioning of 20 watt 4 feet LED tube light fittingsuitable for single phase AC complete with connection etc as required. (Make-Havells model e-lite curve cat no. LHEXBLP7PN1W020 / Philips /Bajaj/ CG/ and Compitable to Havells model e-lite curve cat no. LHEXBLP7PN1W020with similiar specification.) |
| 25 | Supplying and fixing ofsingle phase 230 volt40 Amp DP 2 module MCB Type Changeover i/c PVC cover and connection etc as required(Havells/L&T or equivalent |
| 26 | Supplying, installation, testing and commissioning of ISI marked A.C. ceiling fan having double ball bearing along with 3 nos aluminium alloy blades, Canopy and300 mm down rods etc as required but without fan regulator. including wiring the down rod of standrad length (up to 30 cm) with 1.5 sqmm, FRLS PVC insulated, copper conductor, single core cable, etc. as required. (Make : CG-WW-HE or Equivalent Make of Bajaj,Havells,Orient or other reputed brand1200 mm Sweep,White Colour |
| 27 | Supplying and fixing 100w stepped type electronic fan regulator piano type on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 28 | Supplying and fixing S/J type hook for ceiling fan clamp made of 12mm dia MS bar bent to the required shape etcas required |
| 29 | Supplying,installation,testing & commissioning of 10 watt LED tube light fitting 2 feet (Mirror light) suitable for single phase AC complete with connection etc as required. (Make-Havells model e-lite curve cat no. LHEXACP5IN1W010 / Philips /Bajaj/ CG/ and Compitable to Havells model e-lite curve cat no. LHEXACP5IN1W010with similiar specification.) |
| 30 | Supplying,installation,testing & commissioning of 30 watt LED street light suitable for single phase AC complete with connection etc as required. (Make-Havells / Philips /Bajaj/ CG/ and other with similiar specification.) |
| 31 | Supplying and Fixing of300 mm Exhaust Fan metallic body and blades suitable for single phase,Rated Voltage (Volts) 230,Rated Frequency (Hertz) 50 . Make Havells- Ventil Air DSP or its equivalent of CG/Khaitan/Bajaj |
| 32 | SITC OF 1KW 24 Volt solar power plant with 1.5 Kva hybrid invertor,1000 Wp Poly Crystalline solar panels , 2X 150 AH Solar batteries having 5yrs warranty, mounting structures, suitable cables from AC/DC box to MCB DB, looping box, changeover switch etc as required( Manufacturer -TATA /Luminous/Exide/loom solar/ushaor equivalent make) |
| 33 | SITC OF 3 KW 48 Volt solar power plant with minimum 3.75 Kva hybrid invertor,1000 Wp Poly Crystalline solar panels , 4X 200 AH Solar batteries having 5yrs warranty, mounting structures, suitable cables from AC/DC box to MCB DB, looping box, changeover switch etc as required( Manufacturer -TATA /Luminous/Exide/loom solar/ushaor equivalent make) |