| 1 | Dismantling of Existing old split air-conditioning machines IDU & ODU and the same to be shifted to the section store keeping the items as good as possible. The whole job to be duly performed & supervised by the skilled manpower and company supervisor mending good damages to original finish. |
| 2 | Supply & Delivery of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), havingCooling Capacity range (5.2 KW - 5.3 KW), with fixed speedrotary compressor, refrigerant gas R32/ R410A,, Air flow range CFM (560 - 600), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for 1 Ph. 230V, 50 Hz. power supply.(Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ / Panasonic/ /Mitsubishi Heavy) |
| 3 | Supply & Delivery of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), havingCooling Capacity range (6.6 KW - 7.0 KW), with fixed speed compatible rotary compressor, refrigerant gas R 32 / R 410A, Air flow range CFM (780 - 850), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for 1 Ph. 230V, 50 Hz. power supply.(Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/Mitsubishi Heavy) |
| 4 | Supply & Delivery of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), minimum 15KW nominal cooling capacity ceilingsuspended[concealed] SplitAir ConditionerwithR410A/R407C/R-32 Refrigerant, with single Scroll Compressor / Swingcompressorininvertermachine,suitable foroperationon415V,+_5%,50Hz,3PhAC Supply.withprechargedrefrigerant,Wired/ Wireless remote & all other accessories (Make : DAIKIN model FDMF140BRV16/RZMF140BRY16/Mitsubishi heavyindustries model FDUM125CSV-S6/FDC125CSV-S6 / O-General model ARG60F/AOG60F/Mitsubishi Ele). |
| 5 | Installation testing & commissioning of above AC machinesatIOP Emergencybyfixingtheindoor with 10mmfullthreaded suspenderboltwith double nut & spring washer after S&F35x35x6mmMSAnglewith suitable no of holes to be fastened on ceiling as per instruction of EIC.Out door unit will be fixed on outside wall/terrace on outdoor bracket/MS chair mending good the damages of walls by CC & sand cement plaster. as per instruction of EIC |
| 6 | REFRIGERANT PIPING: Supplying, laying and commissioning of hard copper refrigerant piping (minimum thickness 0.9 mm), complete with fittings, elbows, supporting arrangements etc. (Make: Rajco/Royku) |
| 7 | Liquid Line by 1/4\" copper refrigerant pipe |
| 8 | Liquid Line by 3/8\" copper refrigerant pipe |
| 9 | Suction Line by 5/8\" copper refrigerant pipe |
| 10 | Suction Line by 6/8\" copper refrigerant pipe |
| 11 | REFRIGERANT PIPE INSULATION: Supply & Fixing of Nitrile Rubber tube insulation of 9 mm thick on above Copper Pipes. (Make- K-Flex/Armacell) |
| 12 | Liquid Line by 1/4\" copper refrigerant pipe |
| 13 | Liquid Line by 3/8\" copper refrigerant pipe |
| 14 | Suction Line by 5/8\" copper refrigerant pipe |
| 15 | Suction Line by 6/8\" copper refrigerant pipe |
| 16 | CONDENSATE DRAIN PIPING: Supplying & laying of 25 mm dia (SCHEDULE 40) Drain Water piping work out of PVC / HDPE hared pipes, fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors with insulation. (Make - Supreme/Finolex/Prince Pipe) |
| 17 | CONTROL CABLING: Supply & Laying of 4 Core 2.5 sq.mm.unarmoured Cu control cable. 1.1 KV Gr. PVC/XLPE insulated, PVC- Sheathed cable, Copper armoured for Control cable incl.laying on wall surface by suitable clamping arrangement, proper glanding & finishing the cable ends with solderless sockets for following cables. (Make - Polycab/Havells/Finolex ) |
| 18 | Charges for suspended false ceiling to cover the Indoor Units & Supply air duct including the cost of hinged type trap door arrangement with 3mm thick ACP Sheet as per manufacturer\"s specification on the frame work fabricated from Aluminium hollow rectangular section of size 50mm x 25mm (2mm thick) & duly suspended by Aluminium hollow rectangular section of size 50mm x 38mm (2mm thick) and silicon sealent complete in all respect as per direction of EIC. (Make: Pratapbond/Aludecor/Timex Bond) |
| 19 | Supply & Fixing of Canvas for concealed split unit |
| 20 | Supply & fixing of extruded Aluminium Grill (Make - Caryaire/Ravistar/Dynacraft). |
| 21 | Scraffolding arrangement by making suitable scaffolding by bamboo, ropes & wooden plank etc to be provided as per direction of EIC with transportation cost. |
| 22 | Less Cost of 06 (six) nos old air-conditioning machines aged more than 10 years, along with piping and other accessories - Rs. 36,000/- |
| 23 | The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill.If any refurbished material is supplied and installed, penal action will be taken as per existing rules |
| 24 | Defect Liability Period - 1 (One) year |
| 25 | Make & model of each and every material to be approved by EIC |