|
| 1 | Material and labour for General servicing of 1.5/2.0 TR capacity window type AC after taking down from the existing position, transporting to workshop, clean internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water, replace the unserviceable parts if any including re-fixing the AC in same/ other location and connecting, commissioning complete all as specified and directed. |
| 2 | All as per item No 1 here in above, but Outdoor unit of Split type Air Conditioner 1.5/2.0 Ton. |
| 3 | All as per item No 1 here in above but Indoor unit of Split type Air Conditioner 1.5/2.0 Ton. |
| 4 | All as per item No 1 here in above but Deep Freezer of capacity upto 420 Litres |
| 5 | All as per item No 1 here in above but Refrigerator of capacity 165 Litres to 310 Litres. |
| 6 | Material and labour for General servicing of 1.0/ 1.5/ 2.0 TR capacity window type AC after taking down from the existing position, clean internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water at same location, replace the unserviceable parts if any including re fixing the AC in same/ other location and connecting, commissioning complete all as specified and directed. |
| 7 | All as per item No 6 here in above, but Outdoor unit of Split type Air Conditioner 1.5/2.0 Ton. |
| 8 | All as per item No 6 here in above but Indoor unit of Split type Air Conditioner 1.5/2.0 Ton. |
| 9 | Material and labour for General servicing of 1.5/ 2.0 TR capacity inverter split type AC indoor Unit clean internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water at same location, replace the unserviceable parts if any commissioning complete through OEM all asspecifiedand directed. |
| 10 | All as per item No 9 here in above, but Outdoor unit of Inverter Split type Air Conditioner 1.5/2.0 Ton. |
| 11 | Material and labour for Leak testing of Window type Air Conditioner of capacity 1.0/1.5/2.0 TR including filling of nitrogen gas for pressure testing, finding leaks, Vacuuming the system, necessary brazing work, charging with suitable refrigerant gas of required quantity, testing for proper functioning complete all as specified and directed. |
| 12 | All as per item No 11 here in above but Split type Air Conditioner 1.5/2.0 Ton. |
| 13 | Supply and fix in replacement of Hermetically sealed compressor unit suitable for Window 1.5 Ton capacity in exchange of the existing unserviceable sealed compressor unit including connecting up complete all as specified and directed. |
| 14 | All as per item No 13 here in above but 2.0 TR |
| 15 | All as per item No 13 here in above but spilt AC of 1.5 TR |
| 16 | All as per item No 13 here in above but spilt AC of 2 TR |
| 17 | All as per item No 13 here in above but suitable for Refrigerator of capacity upto 310 Litres |
| 18 | All as per item No 13 here in above but suitable for Deep Freezer of capacity upto 420 Litres |
| 19 | Supply and fix Copper Condensing coil suitable for 1.5/2.0TR capacity Window type Air conditioner including necessary brazing, gas charging, leak testing, Vacuuming etc including taking down old unserviceable condensing coil complete all as specified and directed. |
| 20 | All as per item No 19 here in above but Outdoor unit of Split type Air Conditioner 1.5/2.0 Ton. |
| 21 | Supply and fix in repair Running capacitor 100/120 MFD suitable for Window/Split type AC complete all as specified and directed. |
| 22 | All as per item No 21 here in above but 45/50 MFD. |
| 23 | All as per item No 21 here in above but 36 MFD. |
| 24 | All as per item No 21 here in above but 10 MFD. |
| 25 | All as per item No 21 here in above but 8 MFD. |
| 26 | Supply and fix in repair Capacitor 6 MFD, 240 Volt suitable for fan motor of Window / Split type AC complete all as specified and directed. |
| 27 | All as per item No 26 here in above but 4 MFD, 240 Volt. |
| 28 | All as per item No 26 here in above but 2/2.5 MFD, 240 Volt. |
| 29 | All as per item No 26 here in above but 1.5 MFD, 240 Volt. |
| 30 | Material and Labour for taking down the defective definite purpose magnetic contactor of the split/window AC’s of any make, and Supply and fixing of new contactor of 240 VAC.30 Amps 50 Hz, and coil volt of 208/240V 50/60Hz and Testing complete all as specified and directed. |
| 31 | Supply and fix in repair swing motor suitable for window/split AC any type any make and capacity complete all as specified and directed. |
| 32 | Material and Labour for taking down the damaged air filter set and S/F of new air filter set for split/window type AC’s of 1.5 / 2TR capacity complete all as specified and directed. |
| 33 | Material and Labour for taking down the defective unserviceable starting relay and supply and fixing new rely suitable for 1.5/2TR Window / Split type AC’s and Testing complete all as specified and directed. |
| 34 | Material and Labour for taking down the defective capillary tube set and Supply and fixing new suitable capillary set for split type AC’s complete all as specified and directed. |
| 35 | Material and Labour for taking down the damaged drain connectionsand S/F of new drain connection with necessary clamps, Nipple, coupling etc., for any capacityof ACcomplete all as specified and directed |
| 36 | Material and Labour for taking down the damaged drain pipe as per site and S/F of new drain pipe suitable for split type AC’s complete all as specified and directed. |
| 37 | Supply and fix in repair Anchor bolt/fast nut where ever necessary for fixing of out door/indoor unit of Split AC including taking down old rusted and broken anchor bolt complete all as specified and directed. |
| 38 | Supply and fix in repair flair nut where ever necessary including taking down old rusted and leaked flair nuts complete all as specified and directed. |
| 39 | Supply and fix in repair fan bush suitable for indoor/out door fan motor of spit Ac and widow AC of any type and any make completed all as specifed and directed including taking down old u/s fan bush. |
| 40 | Supply and fix in replace Fan motor 1/5 HP, 240 Volt long shaft suitable for Window type AC of any capacity, make or model complete all as specified and directed. |
| 41 | Supply and replace Fan motor 1/5 HP 240 Volt suitable for outdoor unit of split type AC of any capacity, make or model complete all as specified and directed. |
| 42 | Supply and replace fan motor 240 Volt suitable for outdoor unit of inverter type Split AC of any capacity, make or model complete all as specified and directed. |
| 43 | Supply and replace blower 240 Volt suitable for indoor unit of inverter type Split AC of any capacity, make or model complete all as specified and directed. |
| 44 | Supply and replace fan motor 240 Volt suitable for indoor unit of non inverter type Split AC of any capacity, make or model complete all as specified and directed. |
| 45 | Supply and fix in repair Fan blade suitable for Window type AC of any capacity make or model complete all as specified and as directed. |
| 46 | Supply and fix in repair Fan blade suitable for Outdoor unit of Split type AC of any capacity make or model complete all as specified and as directed. |
| 47 | Supply and fix non inverter type outdoor unit cabinate of split AC suitable for 2 Ton ACwith aluminium fins complete all as specified and direced. |
| 48 | Supply and fix in repair Copper tube 3/8\" including nitrile rubber insulation for refrigerant line suitable for split type AC complete all as specified and directed. |
| 49 | All as per item No 48 here in above butcopper tube of size 5/8\" complete all as specified and as directed. |
| 50 | All as per item No 48 here in above butcopper tube of size 3/4\" complete all as specified and as directed. |
| 51 | All as per item No 48 here in above butcopper tube of size 1/4\" complete all as specified and as directed. |
| 52 | All as per item No 48 here in above butcopper tube of size 1/2\" complete all as specified and as directed. |
| 53 | Supply and fill Refrigerant Gas R- 32 complete all as specified and directed. |
| 54 | Supply and fix in repair cooling coil made out of copper tube suitable for indoor unit of split AC of any capacity complete all as specified and directed. |
| 55 | Supply and fix in repair indoor Printed Circuit Board including sensors and temperature digital display sensor suitable for LLYOD AC of following Models as follows including all connecting wires/ lugs and the model as per site requirement complete all as specified and directed.1.LS24VIHC2.LS24I38FI(G)3.LS24I32WSEL |
| 56 | Supply and fix in repair outdoor Printed Circuit Board including sensors suitable for LLYOD AC of following Models as follows including all connecting wires/ lugs and the model as per site requirement site requirement complete all as specified and directed.1.LS24VIHC2.LS24I38FI(G)3.LS24I32WSEL |
| 57 | Supply and fix in repair indoor Printed Circuit Board including sensors and temperature digital display sensor suitable for LLYOD AC of following Models as follows including all connecting wires/ lugs and the model as per site requirement site requirement complete all as specified and directed.1.LS18I35JA2.LS18FI3.LS18A4.LS18FHO5.LS18I31AF6.GLS18I5FWCBP7.LS18I32WSEL |
| 58 | Supply and fix in repair outdoor Printed Circuit Board including sensors suitable for LLYOD AC of following Models as follows including all connecting wires/ lugs and the model as per site requirement site requirement complete all as specified and directed.1.LS18I35JA2.LS18FI3.LS18A4.LS18FHO5.LS18I31AF6.GLS18I5FWCBP7.LS18I32WSEL |
| 59 | Supply and fix in repair indoor Printed Circuit Board including sensors and temperature digital display sensor suitable for LG split type AC of Model No. MS-Q18ENXA all as specified, as per site requirement site requirement complete all as specified and directed. |
| 60 | Supply and fix in repair outdoor Printed Circuit Board including sensors and temperature digital display sensor suitable for LG split type AC of Model No. MS-Q18ENXA all as specified, as per site requirement site requirement complete all as specified and directed. |
| 61 | Supply and fix in repair indoor Printed Circuit Board including sensors and temperature digital display sensor suitable for LG split type AC of Model No. MS-Q24HNXA all as specified, as per site requirement site requirement complete all as specified and directed. |
| 62 | Supply and fix in repair outdoor Printed Circuit Board including sensors and temperature digital display sensor suitable for LG split type AC of Model No. MS-Q24HNXA all as specified, as per site requirement site requirement complete all as specified and directed. |
| 63 | Supply and fix in replacement outdoor Printed Circuit Board including sensors and temperature digital display sensor suitable for Voltas/Hitachi/Carrier/Blue Star split type AC of any model (invertor type) all as specified, as per site requirement site requirement complete all as specified and directed. |
| 64 | Supply and fix in replacement indoorPrinted Circuit Board including sensors and temperature digital display sensor suitable for Voltas/Hitachi/Carrier/Blue Star split type AC of any model (invertor type) all as specified, as per site requirement site requirement complete all as specified and directed. |
| 65 | Supply and replacement Printed Circuit Board and temperature digital display sensor suitable for Split type/Window type of any capacity make or model complete all as specified and directed. |
| 66 | Supply and replacement Printed Circuit Board and temperature digital display sensor suitable for three phase Tower AC of any capacity make or model complete all as specified and directed. |
| 67 | Material and Labour for repair of Printed Circuit Board (indoor + outdoor ) for inverter type AC of any make and model all as specified and directed. Note : The contractor should give a warrenty for 06 months on the repaired PCB and no extra amount will be charged by the contractor on the failure of the PCB within 06 months. |
| 68 | Supply and replace single phase preventer for Tower AC of any capacity make or model complete all as specified and directed. |
| 69 | Supply and fix in repair factory made MS bracket or Stand suitable for outdoor unit of split AC duly painted and grouted with fastnut/anchor on wall,including necessary PCC work, making surface matching with existing etc, all as specified. |
| 70 | Supply and fill Refrigerant Gas-R-410a complete all as specified and directed. |
| 71 | Material and labour in repair to voltage stabilizer 5 KVA by rewinding the main stabilizing unit and replacing PCB, sensing unit, power relay, connector piece and testing on completion all as specified and as directed |
| 72 | All as per item No 71 here in above but of 4KVA complete all as specified and directed. |
| 73 | Supply and fix in repair 3 Core multistranded Copper Conductor PVC insulated sheathed flexible cable of size 1.5 Sqmm complete all as specified and as directed |
| 74 | All as per item No 73 here in above but 4 Core, 1.5Sqmm complete all as specified and directed. |
| 75 | Material and labour for Sealed compressor unit suitable for 2.5/3 TR capacity 3 phase Tower AC including first filling of refrigerant gas, compressor oil etc. testing and commissioning , including taking down of old unserviceable one complete all as specified and as directed |
| 76 | Material and labour for servicing of condenser coil of Tower split AC 2.5/5 TR capacity, Cleaning / Pressure washing of choked condenser fins, tubes etc, with water soluble material including leak testing complete all as specified and as directed |
| 77 | Material and Labour for detecting the burint wiring of indoor and out door unit and rectifing the same with the help of suitable size wire, connectors shouldering wherever required and making functional in all respect complete all as specified and directed. |
| 78 | Supply and fix in repair Fan motor suitable for outdoor unit of 3 phase tower AC of any capacity make or model all as complete all as specified and directed. |
| 79 | Supply and fix in repair Industrial type metallic 3 pin top 20 Amps 240 Volt complete all as specified and directed |
| 80 | Supply and fix in repair 15 Amps 240 Volt Plug top Heavy Duty complete all as specified and directed |
| 81 | Material and labour for sub main wiring on wall /ceiling with 2 runs of 4 Sqmm single core PVC insulated un sheathed multi stranded copper conductor FR cable 1100 Volt grade drawn through and including PVC conduit pipe of medium grade not less than 20mm dia including PVC conduit specials and 1 run of 4 Sqmm cable single core 1100 Volt grade multi stranded copper conductor FR cable as earth continuity conductor and connecting with suitable size thimble including taking down of old one complete all as specified and as directedNote: Two runs of sub main wire, One run of earth wire and PVC conduit with accessories shall be measured as One unit. |
| 82 | Supply and fix in repair sheet metal enclosure single pole with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 Volt complete all as specified and directed. |
| 83 | Supply and fix in replacement of MCB SP 6 to 32 Amps \"C\" series 240 Volt, complete all as specified and directed. |
| 84 | Material and labour for spray painting single coat anti corrosive enamel paint to cover of window AC of any capacity complete all as specified and directed. |
| 85 | Material and labour for spray painting single coat anti corrosive enamel paint to outer unit of split AC 1/1.5/2 TR capacity complete all as specified and directed. |
| 86 | Material and labour for spray painting single coat anti corrosive enamel paint to cover of Refrigerator of any capacity complete all as specified and directed. |
| 87 | Writing letters or figures for permanent marking of MES No with anti corrosive enamel paint not exceeding 03 cm in height as numbers obtained from Engineer-in-charge in window AC/Split ACs inner and outer unit with thick approved colour paint complete all as specified and directed. |
| 88 | Supply and replace non inverter indoor unit of split type AC of size 1.5/2TR of make by dismantling the old indoor and connecting up with existing outdoor unit including copper pipe and necessary brazing as per site requirement complete all as specified and directed. |
| 89 | Material and labour for disconnecting the unserviceable stabilizer of any capacity 230 volts, any make from site and servicing complete and refixing back with necessary nuts/bolts fixed on walls and connecting up with A/C\"s drilling as per site requirement complete all as specified and directed by Engineer-in-charge. |
| 90 | Supply and fill Refrigerant Gas-R-22 complete all as specified and directed. |
| 91 | Material and labour for dismantling, taking down after disconnection split AC of capacity 1.5/ 2.0TR from existing location including indoor/ outdoor units along with its pipes, connecting cables, clamps/ stands, water drain pipes etc including making good the surfaces to match with existing finishes in all respects and re-fixing at new location as directed with all accessories such as clamps, pipes, stand for outdoor unit including top up of refrigerant gas if required and making satisfactory working of AC unit in all respect complete all as specified and directed by Engineer-in-charge. |
| 92 | Material and labour for dismantling, taking down after disconnecting Split AC of capacity 1.5/2 TR from high rise building (G+2 and above) along with its pipes ,connecting cables , clamps/stands, water drain pipes etc including making good the surfaces to match with the existing finishes in all respects and re-fixing at new location/existing location as directed with all accessories such as clamps, pipes, stand for outdoor unit including top up of refrigerant gas if required and making satisfactorily working of AC unit in all respect complete all as specified and directed by Engineer in Charge. Note: The safety equipments, including necessary tools/scaffolding/safety harness shall be provided by the contractor. The rate for the same shall deem to be included in the quoted rate. |
| 93 | Material and labour for attending day to day complaints pertains to various capacity of cooling appliances as and when required by Refrigerator Mechanic and helper with necessary tools and plants for checking the equipment at existing location, find out the faults to the equipments, complete and rectification of minor problems (compressor control panel resetting with electrical components like replacement of lugs/pin, MCB resetting, electrical wiring connections gas top up to make the AC functional in all respect complete all as specified and directed by the Engineer -In Charge. Notes:- “The contractor shall provide minimum 02 teams of skilled AC mechanics with helperon daily basis `and the number of teams to be increased as per requirement and No ofcomplaints. The team will be responsible for regular maint, testing, inspections and troubleshooting of the cooling appliances. The contractors should ensure that the appliances are maintained in optimal conditions, potentially reducing down time and extending their life span. The contractor should adhere the guidelines below :-Nature of complaint Timeline to Types of complaint Penalty will be leveid due to complete thenon rectification of defects/work complaints registered(a) Minor complaint\"s 0- 24 HoursComplaints like capacitor changes, servicing, Rs 500/- electrical faults, water leakage, gasper day charging, air fillters etc(b) Moderate complaint\"s24- 48 Hours Complaints likeleak arrest, change of PCBs, Rs 1000/- motors, thermostat etcper day(c)Major complaint\"s Within 7 daysIncludes replacement of compressor, Rs1500/-condensers etc per day (i) The nature of complaints will be decided as per the directions of Engr-in-Charge/GE (ii) The technicians detailed for this work cannot be clubbed with another CA”.. (iii) Complaints/service schedule list shall be collected from concerned JE/Engineer-In Charge and report back on daily basis. (iv) The Item shall be measured and paid only when no replacement of spares included in the repair work. If any spare replacement included in the work, the work shall be measured and paid under relavent item only. |
| 94 | All as per item No 93 here-in-above but for minor complaints. |
| 95 | All as per item No 93 here-in-above but formoderate complaints. |
| 96 | All as per item No 93 here-in-above but formajor complaints. |