Tender For Sitc Work Of Fire Fighting At Atonomous State Medical College Distt-Shahjahanpur (U.P.) - Earth work in exacavation in foundations in ordinary soil (loam clay or sand) including lift upto 1.5 m and lead upto 30 mt. & including filling, watering and ramming of excavated earth into the trenches or into the space between building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the E/I upto a distance of 30 mt. from the foundation trenches. 2 Filling of Carted earth in plinth in 20cm layer including leveling, dressing and watering and also including of supply of earth including carted loading & unloading as per direction of Engineer incharge.. 3 Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand. 4 Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone ballast 40 mm nominal size) and curing complete, including cost of form- work, in foundation. 5 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm(4)Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturers standard dilution) 6 Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Upto plinth level (i) R.C.C. work in Footing 7 (ii) R.C.C. work in Beam 8 (iii) R.C.C. work in Columns 9 Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Above plinth to floor-V lvl(iii) R.C.C. work in Columns 10 (i) R.C.C. work in Lintel 11 (ii) R.C.C. work in Beam 12 (iv) R.C.C. work in Slab 13 Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete. 14 Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick 15 Columns,Pillars, Piers, Abutments, Posts and Struts. 16 Edges of slabs and breaks in floors and walls Under 20 cm wide. 17 M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 18 M-150 brick work in 1:6in super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) 19 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation Class M-150in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) 20 Providing and laying damp-proof course 25mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 21 Providing & applying a coat of residual petroleum bitumen of grade ofVG-10 of approved quality using 1.7kg per square metre on damp proofcourse after cleaning the surface with brushes and finally with apieceof cloth lightly soaked in kerosene oil. 22 Providing and laying brick coba 120 mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement & coarse sand mortar finised smooth & top mashed false square 30 cm x 30 cm & side wall parapet shall be mono lythic plaster wall up to 30 cm higher and junction & corner shall be rounded by brick ballast cement & coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work. 23 TMT Fe-500 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 24 15 mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand. 25 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth. (1) 1 cement : 6coarse sand 26 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80mm in girth & finshed even & smooth. (1) 1 cement : 6 coarse sand 27 Making grooves 10 to 12mmwide xam deep in plaster of the walls or in ceiling vertically or horizontally as required. 28 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 25 mm thick 29 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 30 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 31 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials. 32 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 33 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick Single leaf 34 35 mm thick Doubleleaf 35 Providing & Fixing decorative high pressure laminated sheet of plain /wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick 36 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.Fabrication of holdfast for door, chaukhats and windows. 37 Providing & fixing of door / windows grill. 38 Z-Section steel windows with Openable panels, excluding Glass panes. 39 Angle iron chaukhat (40x40x5) 40 Fixing of Door, windows / ventilators chaukhats in position. (a) Door chaukhats 41 (b) Window chaukhats 42 Steel Painting:Applying priming coat:(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.(b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. 43 Providing and fixing Stainless steelsliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete. (a) 250mm x 16mm. 44 Providing and fixing Stainless steel tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 300 x 10mm 45 Providing and fixing Stainless steelhandles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete (a) 125 mm. 46 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 47 Providing and fixing fly proof galvanised M.S. wire gauge, to windows and clerestory windows using galvanised M.S. wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm all complete. With second class teak wood beading 62 X 19mm. 48 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110mm diameter 49 Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.Coupler 110 mm 50 Single Tee with Door Bend 87.5 degree 110 mm Bend 51 Shoe (Plain) 110 mm Shoe 52 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 53 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm 54 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 55 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C 56 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular type switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 57 Wiring for circuit/sub-main wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVCconduit as required. 2X1.5 sqmm + 1x1.5 sqmm earth wire 58 2X2.5 sqmm + 1x 2.5 sqmm earth wire 59 Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 25mm 60 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 61 Supplying and fixingfollowing size/modules, GI box along with modular base& cover plate for modular switches in recess etc as required. 1 or 2 module(75mm X 75 mm ) 62 Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. as required. 63 Supplying and fixing brass batten/angle holder including connectionetc. as required. 64 Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required. 65 Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. 66 Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. Make-Polycab or Eq 10 sqmm 2 core 67 10 sqmm 4 core 68 Supply of12 W LED BULB complete in all respect. Make-Philips or Eq 69 Supply ofLED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface/Pendent complete in all respect.Make-Philips or Eq 70 FIRE HYDRANT & SYSTEM Providing and fixing Single headed, Stainless Steel SS 304, ISI marked oblique patternhydrant landing valvewith80mmdia flangedinlet and 63mm dia instantaneous type female outlet complete with ABS cap and G.I. chain, twist release type plug and all accessories as per 13:5290-1983 (Type A)(Lifeguard/Safex) 71 Providing and fixing First-Aid Fire HoseReel wallmounting swinging type complete withdrum, bracket, 20 mm dia x 40M longhigh pressureHose Reel tubing as per IS:444 with Gun-Metal shut-off nozzle having 5mm dia. orifice, fixing 25 mm dia Ball valve. etc. 72 Providing and fixing Non-percolatingflexible hose(RRL type-A) ISI marked (IS:636) 63 mm dia x 15 M long complete with instantaneoustype gunmetal / SS,63mm dia. IS markedMaleandfemale couplings. 73 Providing and fixing Stainless Steel 304, 63mm dia short size branch pipes with 20 mm dia nozzles with 63mm GM/SS instantaneous coupling ISI marked (IS: 903). 74 Providing and fixing Gun-Metal Fire Brigade connection (Suction collecting head) consistingof63 mm dia instantaneous type male coupling with built-in check valves and 150 mm dia.flanged outlet complete with bolts, nuts and rubber insertions as requiredas perIS:904-1983. 4 Way 75 2 way 76 Providing and fixing dial type pressure gauge with syphone complete in all respects. Dial dia 100 mm, calibration 0-15 kg/sq cm. Valve shall be paid separately. 20 mm dia nominal bore 77 Supply and fixing of MS hose box of 750x600x200 mm fabricated of 16 gauze MS sheet 78 Providing, laying, jointing and testing in trenches /wall the following sizes of M.S. class `C (heavy class) pipes conforming to IS:1239complete as required. 80 mm dia 79 100 mm dia 80 150 mm dia 81 200 mm dia 82 Providing protection toembedded M.S pipesandfittingsbywrapping 2 mm thick pypkote protection including proper overlaps on joints. 200 mm dia 83 150 mm dia 84 100 mm dia 85 80 mm dia 86 Providing & fixing of butterfly valve suitableforpressure 15 Kg/Sqcm. with flanges, nut bolts&gasketscomplete required. 80 mm dia 87 100 mm dia 88 150 mm dia 89 200 mm dia 90 Supply and fixing of MS angle iron support of suitable size 91 FIRE SPRINKLER SYSTEM Providing and fixing & commissioning of extra coverage 20 mm dia. Quartzoid bulb type G.M. Sprinklerhead suitable to operate at 68 deg.C(UL/ISI/LPClisted /approved) Standard Pendant sprinkler 92 Extra Coverage side wall type 93 Providing, laying, jointing and testing in trenches /wall the following sizes of M.S. class `C (heavy class) pipes conforming to IS:1239complete as required. 25 mm dia 94 32 mm dia 95 40 mm dia 96 50 mm dia 97 65 mm dia 98 80 mm dia 99 100 mm dia 100 150 mm dia 101 200 mm dia 102 Providing and fixing gun metal ball valve suitable for pressure 15 Kg/Cm2 and confirming to IS: 778ofthefollowingsizeincluding providing necessary union/flange. 25 mm dia 103 Providing & fixing of butterfly valve suitableforpressure 15 Kg/Sqcm. with flanges, nut bolts&gasketscomplete required. 80 mm dia 104 100 mm dia 105 150 mm dia 106 Supply and fixing of 1000 mm length sprinkler flexible pipe hose pipe 107 FIRE PUMP ROOM (ACCESSORIES & PUMPS INSTALLATION) Supply, installation, testing & commissioning of electric driven Hydrant/Sprinkler Pump suitable for automatic operation consisting of the following :Horizontal end suction centrifugal pump complete with mechanical seal and including necessary arrangement for testing of pump Squirrel cage induction motor suitable for 415 V, 50 Hz, AC supply of suitable rating for the above pump with synchronous speed of 2900 RPM T.E.F.C. type and conforming to IP:55 and flexible coupling and coupling guard with the pump. Common bed plate of fabricated mild steel channel or cast iron type. The pump shall be of the following specifications: Discharge- 2850 lpm Head - 88 m No. of stage preferred - Single Speed RPM - 2900 Material of constructiona) Impeller - Bronze b) Casing - C.I. c) Shaft & Shaft Sleeve- SS-410 d) Bearing - Grease Lubricatede) Seal & Make - Mechanical Type of pump- End suction f).P- 75 HP 108 Supply, installation, testing & commissioning of diesel driven Hydrant/Sprinkler Pump suitable for automatic operation consisting of the following : Horizontal end suction centrifugal pump complete with mechanical seal and including necessary arrangement for testing of pump Diesel driven prime mover Common bed plate of fabricated mild steel channel or cast iron type. The pump shall be of the following specifications:Discharge- 2850 lpm Head - 88 m No. of stage preferred - Single Speed RPM- 1500 Material of construction a) Impeller - Bronze b) Casing - C.I. c) Shaft & Shaft Sleeve- SS-410 d) Bearing- Grease Lubricated e) Seal & Make - Mechanical Type of pump - Sidesuction f) H.P -- 125 BHP 109 Supply, installation, testing & commissioning of electric driven Jockey Pump suitable for automatic operation consisting of the following :Horizontally mounted centrifugal end suction pump complete with mechanical seal and including necessary arrangement for testing of pump. Squirrel cage induction motor suitable for 415 V, 50 Hz, AC supply of suitable rating for the above pump with synchronous speed of 2900 RPM T.E.F.C. type and conforming to IP:55 and flexible coupling and coupling guard with the pump. Common bed plate of fabricated mild steel channel or cast iron type. The pump shall be of the following specifications: Discharge - 180 lpm Head - 88 m No. of stage preferred - Single Speed RPM - 2900 Mover- Electric Motor Driven Material of constructiona) Impeller - Bronze b) Casing - C.I.c) Shaft & Shaft Sleeve- SS-410 d) Bearing - Grease Lubricated e) Seal & Make - Mechanical Type of pump - End suctionf) H.P.-- 15 HP 110 CUBICAL FIRE PANEL BOARD i) For 2 x 75 HP Wet Riser / Sprinkler Pump ii) For 2x 15 HP Jockey Pumps Supply, installation,testing andcommissioningofnon draw out Cubical typesectinalised floor standing powder coated switch board of 31 MVA fault capacity at 415 V complete with 4 strip, 630 A capacity Aluminium Bus - Bar Electrolytic grade, cable alley & supplying & fixing of following switchgears as per specifications including connections & interconnections. 111 POWER & CONTROL CABLING Power Cabling (XLPE) insulated and PVC sheathed, armoured, Aluminium Conductor of 1.1 KV grade on existing cable trays) including all termination points. 3C x 50 Sq. mm 112 4C x 16 Sq. mm 113 Control Cabling (PVC insulated and PVC sheathed, armoured, Copper Conductor of 1.1 KV grade on existing cable trays). 2C x 1.5 Sq. mm 114 Providing,fixing,testing and commissioning of pressure vessel for pressurization of hydrant system complete with pressureswitches, pressure gauge, valves at outlet / drain to operate as per operating sequencesincluding80 mmdia drain valve, air release valvewith stop cock on the top Duly paintedfrom inside and outside complete as required. 250 mmx 1200 mm 115 Providing & fixing of butterfly valve suitableforpressure 15 Kg/Sqcm. with flanges, nut bolts&gasketscomplete required. 50 mm dia 116 65 mm dia 117 80 mm dia 118 100 mm dia 119 150 mm dia 120 Providing and fixing gun metal ball valve suitable for pressure 15 Kg/Cm2 and confirming to IS: 778ofthefollowingsizeincluding providing necessary union/flange 25 mm dia 121 Providing and fixing of C.I. Non returnvalve suitablefor pressure 15 Kg/Sqcm.withflanges, Nut, bolts & washers, painting etc.completeas required. 80 mm dia 122 150 mm dia 123 ProvidingandfixingC.I.`Y strainer with bronzeperforatedsheetbasket testedtoapressureof 15 Kg/sqcm includingrubber gasket, flanges, nuts, bolts and washers, complete as required. 150 mm dia 124 100 mm dia 125 Supply and fixing of pressure switch for automation of pumps 126 SupplyInstallationTesting&CommissioningofMicroprocessorbasedNetworkableanalogueaddressabletypefirealarm control panel with 8X18 characters LCD display. The panel should be a single panel having 2 Loops with CAN networking capacity ,Two loops networkable panel with capacity of 477 devices.FACP shall accommodate devices at 100% capacity in any combination.The PANEL should have provision to integrate with any PA system Input/ Output Modules . The PANEL should have15 LEDs to display important information. System Integrator to be submit testing report from OEM. The PANEL should have Non-Volatile memory ensures the data does not loss even if power supply is accidentally removed. The PANEL should have RS232 interface enablescommunication with PC.The Fire Alarm Panel shall have sufficientnumbersofprogrammable relaycontrolsfor controlling AHUs, pressurization fans, ventilation fansat fire pump room, monitoring of fire sprinklerand fire hydrant pump, 240 voltsAC power supply. The panel shall include integral SMF lead acid batteries with sealed cells of 24V capable of running for a minimum of 8 hours with integral battery charger complete as required . The PANEL shall be able to generate minimum 999 History Events The Panel shall have provision for BMS IntegrationwithfollowingITProtocals like Modbus etc.ThePanelshallhaveEN54aprrovedLPCBlisted.(GST/Notifire ) 127 SITC OF (Multi -Sensor)Combination Heat Photoelectric Smoke Detector- Intelligent Combination Heat Photoelectric SmokeDetector with Remote Indicator Output and MagneticTest Function, With base (Certified by LPCB) 128 Supply, installation testing and commissioning of Analogue Addressable Manual call pointr, with flush mounting glass box resettable type, unique plug and play installation concept, confirms to EN 54-11 & EN-54-17, LPCB approved, Vds approved resettable glass type compatible with main fire alarm control board microprocessor basedand blinking facility complete Analogue addressable protocol having, Bi-coloured status LED, Non-frangible element fitted as standard (confirms to EN 54)Make - GST/Notifire 129 Supply, installation, testing and commissioning of addressable wall mounted interliigent loop powered electronic sounder cum strobe, with control module(all tones as per EN54-3), low power requirement, 07 volume levels, IP 65 rating, LPCB approved in accordaance to EN-55 part -3Make - GST/Notifire. 130 Supply, installation, testing and commissioning of sensor common mounting base, features integral short circuit isolator, slim profile,EN-54-17 Approved by LPCB and Vds approved operating voltage 15 to 30 Vdc complete all as specified and directed by Engr-in-Charge. Make - GST/Notifire 131 Supply and laying 2 x1.5 sq mm FRLS copper conductor armoured cable 600/1000 Volt (Polycab/Bonton/Fusion polymer) 132 Supply,laying, Jointing, testing and commissioning in trenches/fixing with clamp on wall connecting, thembling, glanding of XLPE insulated PVC innersheathed, armoured, galvanised steel strip or wire, LT control cableFRLS multistranded copper conductor, 1100 volts grade, cross-sectional area 2.50 Sqmm 4 core as per IS 7098 (Part I) 1988 complete all as specified and directed by Engr-in-Charge. 133 Supply, installation, testinngUPS 1 KVA (1000 VA),40-50 Min backup, boost function for low input over voltage protection Extended input voltage range of 135 to 300 volt UPS to battery backup mode including Battery back up system for 48 hrs suitable size of Battery should be includefor fire alarm control panel all as directed by Engr-in-Charge. Make: Microtec/ Luminious/Genus Power. 134 Supply and fixing fire alarm sirens Electronics horizontal type continous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured, single phase, 220/250V, 6000 RPM, 50 Hz, AC supply,at 1.5 Mtr with sound output variation of +5 db 500 m range, IP-65 Weatherproof, with suitable size of mounting stand and protection cover for siren.Make- Kheraj/Safecontrols/NSD 135 Supply and fixing of control unit for siren with Addressable Control Module for integration with main Fire Alarm panel. Make - Safecontrols/NSD. 136 Supply, Installation, testing and commissioning of Network module. The module shall connect panels and repeator panels through RS 485. The modules shall use RS 485 data at a baud rate. The Network module must be configured master/slave, multiple Master/Slave and peer to peer Networking, Net work card for integration of 2 loop Panels into a net worked system complete all as specified and directed by ENgr-in-Charge. Make - GST/Notifire. 137 Supply,Installation,TestingandCommissioningof ActiveRepeaterAnnunciator Panel complete with Passwordprotected access level, 8X18 characters LCD screen, 15 LEDs to display important information. 138 Excavation in trenches in hard/dense soilnot exceeding 1.5 mtr deep and notexceeding 1.5 mtrwide for laying of cables, foundation, etc or for shaft well, cesspits, manholes, pireholes, etc not exc 10 Sqm plan and getting out in soft/loose soil complete all as specified and directedat site. 139 Returning,filling inincluding spreading, levelling, watering and well ramming excavatedsoil inlayers not exceeding 25 cm thickeach, backin trenches after cableshave been laid and tested , poles, stays, struts havebeen erected and tested all as specifiede and directedat site. 140 Removing excavatedsurplus soil (Soft/Hard soil)obtained from exavation to a distance not exceeding 50 mtrand deposting where directedat a level not exceeding 1.5 m above the starting point all as sspecifed and ddirected 141 Material and labour for sand cushioning with a layer dry clean Gangariver of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified.Note: Punned thickness 18 cm shall only be measured. 142 Supply and laying old size sub class B bricks laid flat in trenches over the cable with the length of brickperpendicular to the directionof cable length, adjacent/abutting each other for cable protection complete all as specified and directed. 143 M&L for boring of holes under road/drain/PCC path by manual method for inserting the upto 40 mm dia light GI tubing for cable protection in minimum 60 mm depth from normal ground level all as specified and directed. 144 Supply and laying 40 mm dia GI tubing light grade complete with all fittings (ISI Marked) laid in trenches/fixed complete to walland ceiling or laid in floors, trenches, under road crossing, fixed on poles/walls for cable protection all as specified. 145 M&L for fixing of LT cable route indicator aluminium cast material, 100 mm dia, round with 5-6 mm thick, two hole for mounting, 3 mm Embossed letter as appropriate, includingstand of made out of angle iron of size 40 x 40x 6mm thick of length 90cm (60 cm above ground level) as directed and to be grouted 2 feet from the ground level including all excavation and earth work complete all as specified and directed. 146 Wall Mounted Horn type High intencity 6 Watt Fire Alarm Sounder complete with LMT (Eon AV/Hitune) 147 Supply and installation of 1000 watt PA system rack consisting ofAmplifier and one microphone.(NSD/Safecontrols)