Tender For Restructure Of The Building Of 33/11 Kv Sub Station And Development Work Of Umaid Hospital S/S Jodhpur Restructure Of The Building Of 33/11 Kv Sub Station And Development Work Of Umaid Hospital S/S Jodhpur - 1 Dismantling stone rubble masonry including stacking of serviceable material and disposal of unserviceable material within 50 meters lead.In Cement mortar. (B-157/14.9.2) 2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.1: 3: 6 or richer mix.B-14.2.1 3 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.1: 4: 8 or leaner mix.B-14.2.2 4 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar.B-14.7.3 5 Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead:Of area 3 square meter and below.B-14.12.1 6 Dismantlingsteelworkinsinglesectionsincludingdismemberingandstackingwithin50 meters lead in: Channels, angles, tees & flats.B-14.17.2 7 Dismantling stone slab roofing over wooden karries and battens (dismantling karries and battens to be paid for separately) including stacking of serviceable material and disposal of unserviceable material within 50 meter lead:B-14.29 8 Carriage of materials including Building Rubbish Stone metal (Grit and ballast etc.) and lead 15km G-4.2 9 Carriage of materials including Stone for Masonry work & soling and lead 15km G-4.3 10 Earth work in excavation by mechanical means (Hydraulic exeavation / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift upto 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering and ramming and disposal of surplus excavated soil as directed within a lead of 50 mtr.All kinds of soils (B-44/1.8 ) 11 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).(B-54/3.1.6) 12 Random Rubble stone masonry forwith hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in : cement Mortar 1:6: (1 Cement : 6 Sand). ( B-69/6.1.6)) 13 Random Rubble stone masonry for with hard stone in superstructureabove plinth level one storey height for wall up to 30 cm. or less thickness in cement sand mortar 1:6 (1 Cement : 6 sand) (B-69/6.2.6+6.3.4)) 14 (a)Add extra for rock facing with porper projection and chisal dressing of edges of stone 2 line dressing for building corners,jambs including uniform joints.(B-70/6.4.6) 15 (b)Add extra for facing as per design and detailed specifications including additional cost of stonesCourse rubble facing First Sort. (B-70/6.4.1) 16 Add extra for facing as per design and detailed specifications including additional cost of stonesCourse rubble facing Second Sort. (B-70/6.4.2)) 17 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix(B-59/4.1) 18 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix (B-159/4.3) 19 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc.(B-61/4.10.2) 20 Providing & fabricating steel reinforcement for R.C.C. work including straightening,cutting, bending, palcing in position and binding ( including cost of binding wire) All complete up to floor three level. cold twisted deformed bars(IS : 1786) (B-62/4.13.1) 21 Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size).(B-55/3.2.4) 22 Half brick masonry in Super Structure using bricks of designation 75 with nominal hoop rainforsed (2 Nos. 6mm MS bar) at every fourth course in for hoop rainforcement 1Sqm. 6mm MS bar.Cement mortar 1:6 (1-Cement:6-coarse sand).(B-66/5.8.4+5.9) 23 S/F in wall machine cuts and polished stone shelves, tands and sills in CM 1:3 with machine cut adages.Kota stone MIN 30 mm thick.(B-72/6.17.3) 24 Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred weldedand grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C Cblock 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to framefor paitam fixing float glass 4mm thickpanes with glazing clips and metal sash putty andfixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge Window openable.(B-102/9.28.1)) 25 Supplying and fixing fixed wire gauge of 14 mesh X 24 gauge to the metal frame of rolled section by metal beading 20x3 mm with suitable screw at not exceeding 150mm distance. (B-102/9.26)) 26 Providing and fixing square bars or other flat welded to window, ventilators etc. (B-102/9.27) 27 Pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) :Deep groove pointing(12.31.3) 28 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :25 mm thick(B-139/12.3.1) 29 (b)Plaster on new surface on walls in cement sand mortar 1:6including racking of joint etc. complete fine finished : 20mm thick(B-139/12.3.2)) 30 Plaster on new surface on walls in cement sand mortar 1:4 including racking of joint etc. complete fine finish :25 mm thick(B-139/12.2.1) 31 Providing & laying broken glazed tiles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge.(B-109/10.24) 32 Supply and fixing Jodhpur sand stone Machine cut Dash, Coping,sill,lintel fixed in cement sand mortar 1:4 9 cm (3.5) thick (B-82/6.88.(ii) 33 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge :Profile B (b-99/9.6.2) 34 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A:25 mm thick .(B-93/8.13.1) 35 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand)For area of each slab from 901 to 2000 Sq.Cm :(B-132/11.18.1) 36 Supply and fixing in cement mortar welded hand railing made out of MS round or square bars, flats etc. for staircase or verandah as per design complete in all respect (wooden or PVC hand railing to be paid extra) with priming coat of red oxide. (B-99/9.7) 37 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001 to 5000Sqcm(B-132/11.19.2) 38 Finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding:New work (Two or more coats applied @ 3.84 kg/10 sqm).(B-145/12.41.1) 39 Painting with synthetic enamel paint of apprived brand and manufacture to give an even shade: one or more coats on New work.(B-146/12.46.1) 40 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer.B-144/12.37.1] 41 Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension).B-99/9.10 42 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).(B-86/7.12) 43 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).(B86/7.13) 44 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide B-9.80 45 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 40mm nominal size). (B-55/ 3.1.3) 46 Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4,with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge (B-107/ 10.16) 47 Providing & fixing ms sheetdouble leaf door shutters in angle iron frame 35x35x5 mm suitablly diagonally braced with 25x3mm flat ironabove and below lock rail of size 50x5 mm beading extra includingall fittings, as per direction of engg. incharge but excluding coes of chokhats including two coats of anti corrastie red oxide primer panit.M.S. sheet 22 SWG (B-100/9.17+9.17.1) 48 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :(B-109/10.22) 49 Finishing with neat cement (punning). (B-140/ 12.7) 50 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately).Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer)For fixed portion B-175/16.1.1.1 51 For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately).Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer)B-175/16.1.2.1 52 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With glass panes of 4.0 mm thickness ( weight not less than 10.0 kg/sqm) as per IS : 2835.B-176/16.5.1 53 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. With stainless steel cover plateB-176/16.6.1 54 P&F expanded grill made of anodised aluminium as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminium window/ vent with reqd. screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge.(16.10.1) 55 Excavation for roadwork in soil including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and disposal to the embankment location with a lift upto 1.5 m and lead upto 100 m as per Technical Specification Clause 302.3(R-8/3.1.1.1) 56 M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etcCategory‘B’ Denated only two side like I,Z,T shape etc. as per IRC SP63:2004(B-137/11.38.3(B) 57 Supply and fixing chittar or equivalent stone slab perchits with making edges and top surface level in cement mortar 1:3 complete finished Upto 2.15m span Soorsagar or eqvt. White Ashlar(b-77/6.51.1) 58 Providing & Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592:1992 Marked) of approved quality/make including jointing of pipes complete (B-257/3.44.1)a) 110 mm dia 59 P & F Indian type white glazed vitreous china 1st quality W.C. Orissa pan (I.S.: 2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor : (S-1/1.2.1)Size 530 x 410 mm. 60 P & F WVC wash basin (1st quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. Pillar cock (I.S.: 8934 Mark) & 32 mm C.P. brass waste coupling of approved make, 25mm G.I. waste pipe complete including cutting & making good the wall :Size 510mm X 400 mm (B-221/1.36.2) 61 P&F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge (B-223/1.45.1))Size 500X400mm 62 Construction of cement concrete chamber 125mm dia stainless steel sheetgrating.(B-255/3.38.4)) 63 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)15 mm nominal size(b-240/2.37.1) 64 (B)25 mm nominal bore (B-240/2.37.3) 65 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.15 mm nominal size(B-240/2.39.1) 66 P& F Bib Cock (IS : 8931 Mark), Superior quality of approved make a)Brass bib cock 400gm 15 mm nominal bore (B-232/2.7.1) 67 b)CP Brassbib cock 15mm Dia nominal bore(B-232/2.7.3) 68 c)C.P.Brass Long body 15 mm nominal bore not less then 690 gm. (B-232/2.7.4) ) 69 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15 mm Brass (IS:8931 marked).(2.12.1) 70 P&F Ball Cock (IS: 1703 Mark) with Rod & P.V.C. Ball Complete:Brass wt. 400gm 20mm (S-19/2.11.2) 71 P & F Full-way valve (IS :778 Mark) or wheel valve of approved make :(a) Gun-metal 15mm 72 (b) Gun-metal 25mm (S-22.15.1&3) 73 P&F storage tank confirming to IS(12701/89) standards of approved make with cover, 25mm dia 1Mlong G.I. over-flow pipe and 25cm long wash out pipe with plug and socket, including making connec- tion etc. complete of approved designb) 500 Ltr capacity. (2.26.3) 74 P&F Square -mouth gully trap A grade (IS : Marked) of approved make complete with C.I. Grating, frame & cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5 :10 base concrete, 40mm thick C.C. M-15 grade coping, 12 mm thick cement plaster in CM 1:3 complete as per approved design & type. Trap size 150 X 100mm, 7.2 kg. C.I. cover with frame, Internal chamber size 300 X 300mm. (S-3.5.1) 75 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M(B-250/3.19.1-3.32.1+3.33.2) 76 Providing & Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592:1992 Marked) of approved quality/make including jointing of pipes complete (B-257/3.44.1)a) 75mm dia 77 b) 110 mm dia 78 Providing & Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipe FittingsType B for sciland waste discharge system (IS:13592:1992 Marked) of approved quality/make110 mm dia.(3.45.1(a) Coupler (Socket) 110mm dia(3.45.1)) 79 b) Band 87.5 110mm dia(3.45.4 ) 80 c) Vent Cowel110mm dia(3.45.30 ) 81 d)SingleTee with door 110mm dia(3.45.17) 82 P & F Flush Cock/Flush Valve (IS: 9758 Mark) for WC of approved quality make: Brass / Gun metel Half-turn wt. 1 kg. of approved quality/ make, 25 mm nominal bore (233/2.14.9) 83 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR E-1.1 (A) short poing (upt 3 mtr.) (1.1.1) 84 (B) Medium point (Upto 6.0 Mtr.)(1.1.2) 85 (C) Long point (Upto to 10.0 Mtr.)(1.1.3) 86 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR2 x 2.5 sq. mm. + 1x1.5sqmm E- 4.1.7 87 (B) 2x4.0 sq. mm + 1x 2.5 sq mm ( E-4.1.14) 88 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR On board E- 1.3.1 89 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR E- 1.4.2 90 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR E-7.37 91 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR E- 5.9 92 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing E- 17.2.2 93 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) E- 15.7.3 94 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating E- 7.29.1 95 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Single pole MCB (With B/C curve tripping Characteristics)6 A to 32 A rating(E6.1.1.2) 96 Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSRDouble pole 30/40 amp (E 6.2.1.1) 97 P & F of ventilating fans, Capacitor start, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required.250 mm sweep Group-1 (E-15.13.3 )