| 1 | Labour charges with tools and tackles and transportation for dismantling of Existing electrical installations like panels, HTPN DBs, SPN DBs, conduits, wirings,cables, light fittings, fan fittings, switch-sockets and the same to be shifted to the section store keeping the items as good as possible. The whole job to be duly performed & supervised by the skilled manpower and company supervisor mending good damages to original finish. |
| 2 | S/Installation of floor mounted industrial LT panel board with following electrical accessories made out of 14 SWG (BBC) & 16 SWG (Cable end boxes) CRCA sheet on MS frame structure made out of MS angle (50 x 50 x 6mm) & MS flat (50 x 6mm). The main connection bars & interconnecting bars to switches are of suitable sizes & capacity of electrolytic copper bars with colour sleeves. The panel with earthing attachment is to be painted with powder coated paint as per direction of EIC. as follows :- |
| 3 | (a) 415V., 315A., TPN main switch in SS enclosure with 3 nos. 315 Amp HRC fuses as incommers- 02 No. (LK) (Cat No. SK90490) |
| 4 | (b) Castle Lock for Both Incomer SFU Chamber with single key- 02 Set |
| 5 | (c) 415V., 200A., TPN main switch in SS enclosure with 3 nos. 200 Amp. HRC fuses as outgoing - 1 no.(LK) (Cat No. SK90488)(d) 415V., 160A., TPN main switch in SS enclosure with 3 nos. 160 Amp. HRC fuses as outgoing - 1 no.(LK) (Cat No. SK90487) |
| 6 | (d) 415V., 125A., TPN main switch in SS enclosure with 3 nos. 125 Amp. HRC fuses as outgoing - 1 no.(LK) (Cat No. SK90486) |
| 7 | (e) 415V., 63A., TPN main switch in SS enclosure with 3 nos. 63 Amp. HRC fuses as outgoing- 2 nos. (LK) (Cat No. SK90484) |
| 8 | (f) 315A. 4-Bar BBC with tinned copper bars- 1 set. |
| 9 | (g) 500V., C.T. Coil (C.T. Ratio-400/5A.)- 3 Nos. |
| 10 | (h) LED Indicator lamp (LK)- 11 nos. |
| 11 | (i) Voltmeter (AE)- 0 - 500 Volt-01 no. |
| 12 | (j) Ammeter (AE)- 0 - 400 Amp.- 01 no. |
| 13 | (k) Selector Switch (Kaycee make)- 02 nos.(l) 2A , 240V, SP MCB (LK)- 13 Sets |
| 14 | (m) Danger Board-01 no. |
| 15 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment(Make: Legrand/ABB/Schneider) |
| 16 | 8 way |
| 17 | 6 way |
| 18 | Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment. (Make: Legrand/ABB/Schneider) |
| 19 | 8 way |
| 20 | 6 way |
| 21 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment6 way (Make: Legrand/ABB/LK) |
| 22 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Make: Legrand/ABB/LK) |
| 23 | 2+10 way |
| 24 | 2+12 way |
| 25 | Supplying and fixing 125A, 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etcMake(LK/Havells/ABB) |
| 26 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection(Make: Legrand/ABB/Schneider) |
| 27 | 200 A |
| 28 | 160 A |
| 29 | 125 A |
| 30 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand/ABB/Schneider) |
| 31 | 63 A, FP |
| 32 | 40 A, DP |
| 33 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make: Legrand/ABB/schneider) |
| 34 | 6-32 A, SP |
| 35 | 6-32 A, DP |
| 36 | 32 A, TP |
| 37 | 63 A, TP |
| 38 | Supplying and fixing 2 way MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment |
| 39 | Supply of4 Core XLPEInsulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes. [ Make: Havells / Gloster / Polycab] |
| 40 | 185 Sq.mm. |
| 41 | 95 Sq.mm. |
| 42 | 70 Sq.mm. |
| 43 | 50 Sq.mm. |
| 44 | 25 Sq.mm. |
| 45 | Laying of cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. |
| 46 | 4 Core 185 Sq.mm. |
| 47 | 4 Core 95 Sq.mm. |
| 48 | 4 Core 70 Sq.mm. |
| 49 | 4 Core 50 Sq.mm. |
| 50 | 4 Core 25 Sq.mm. |
| 51 | Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire as per GS |
| 52 | 4 Core 185 Sq.mm. |
| 53 | 4 Core 95 Sq.mm. |
| 54 | 4 Core 70 Sq.mm. |
| 55 | 4 Core 50 Sq.mm. |
| 56 | 4 Core 25 Sq.mm. |
| 57 | Supplying and fixing compression type gland and finishing thoseforfollowing XLPE / PVC armoured cable 4 Core as per GS.Make Dowells |
| 58 | 4 Core 185 Sq.mm. |
| 59 | 4 Core 95 Sq.mm. |
| 60 | 4 Core 70 Sq.mm. |
| 61 | 4 Core 50 Sq.mm. |
| 62 | 4 Core 25 Sq.mm. |
| 63 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FRLS\" PVC insulated & unsheathed copper wire (Brand- Finolex/Havells/Polycab/Gloster) in 20mm size PVC rigid conduit \"FR\" (Precision/Polycab make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch(Brand- Legrand-myrius/Crabtree/ABB) fixed on Modular GI/PVC switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. |
| 64 | Average run 9 mtr |
| 65 | Average run 10 mtr |
| 66 | Average run 12 mtr |
| 67 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FRLS\" PVC insulated & unsheathed copper wire (Brand Finolex/Havells/Polycab/Gloster) in 20mm size PVC rigid conduit \"FR\" (Precision /Polycab make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish |
| 68 | Average run 6 mtr |
| 69 | Average run 9 mtr |
| 70 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FRLS\" PVC insulated & unsheathed copper wire (Brand- Finolex/Havells/Polycab/Gloster) in 20mm size PVC rigid conduit \"FR\" (Precision/Polycab make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand- Legrand-myrius/Crabtree/LK/ABB) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works |
| 71 | On Board |
| 72 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FRLS\" PVC insulated & unsheathed copper wire (Brand Finolex/Havells/Polycab/Gloster) in 20mm size PVC rigid conduit \"FR\" (Precision/Polycab make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish |
| 73 | On Board |
| 74 | Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand: Finolex/Polycab/Gloster) in 20mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required |
| 75 | 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 76 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 77 | 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC |
| 78 | 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC |
| 79 | Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand: Finolex/Polycab/Gloster) in 25mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required |
| 80 | 4 x 56/0.3 (4 sqmm) + 2 x 36/0.3 (2.5 sqmm) ECC |
| 81 | Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required |
| 82 | 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC(For UPS I/C & O/G Connections) |
| 83 | 2 x 80/0.4 (10 sqmm)(For UPS neutral earthing) |
| 84 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. (Brand- Legrand-Myrius/Crabtree/LK/ABB) |
| 85 | 6 Module |
| 86 | 2 Row 12 Module |
| 87 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works(Brand- Legrand-Myrius/Crabtree/LK/ABB) |
| 88 | 2 Module |
| 89 | 4 Module |
| 90 | Supply & Fixing 240 V 6 A Modular type switch (Brand- Legrand-Myrius/Crabtree/LK/ABB)on existing GI Modular type switch board having top cover plate and making necessary connections as required. |
| 91 | Supply & Fixing 240 V 16 A Modularkey type switch (Brand- Legrand-Mylic/Crabtree/LK/ABB)on GI Modular type switch board having top cover plate and making necessary connections as required. |
| 92 | Supply & Fixing 240 V, 6A, 3 pin Modular type plug socket (Brand- Legrand-Myrius/Crabtree/LK/ABB) , without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc. |
| 93 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket(Brand- Legrand-Myrius/Crabtree/LK/ABB) , without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 94 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 95 | Supply & Fixing 240 V, 3 nos. 6 A, 3 pin Modular type plug socket & 1 no. 16A , 5 pin Modular type plug socket with 3 nos. 6A Modular type switch & 16A Modular type switch (Brand- Legrand-Myrius/Crabtree/LK/ABB), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[Computer Board] |
| 96 | Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection[Make: Legrand/LK/ABB] |
| 97 | Supplying and fixing PVC Rigid Conduit MMS \"FR\" [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works |
| 98 | 20mm size |
| 99 | 25mm size |
| 100 | 32mm size |
| 101 | Supplying & Fixing sheet metal/PVC inspection box (16 SWG) of the following sizes (in mm.) flushed in wallas per GS |
| 102 | 175 mm x 100 mm x 65 mm |
| 103 | 200 mm x 150 mm x 65 mm |
| 104 | 240 mm x 200 mm x 65 mm |
| 105 | Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required |
| 106 | 175 mm x 100 mm x 65 mm |
| 107 | 200 mm x 150 mm x 65 mm |
| 108 | 240 mm x 200 mm x 65 mm |
| 109 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 110 | 2.5 Sq.mm. |
| 111 | 4 Sq.mm. |
| 112 | 6 Sq.mm. |
| 113 | 10 Sq.mm. |
| 114 | 16 Sq.mm. |
| 115 | Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Make: Anchor) on HW board incl. S & F HW board. |
| 116 | Supply & Fixing 240 V,16 A, 3 pin Modular type plug top (Brand approved by EIC) & necy. Connections. (Make: Anchor) |
| 117 | Supply & Fixing of modular Blank plate (Brand- Legrand-Mylic/Crabtree/LK/ABB) |
| 118 | Supply & Fixing of perforated GI cable tray (18SWG) with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6 mm dia MS suspender with / without angle iron support as per GS. |
| 119 | 200 x 50 x 1.25mm With 25x25x3mm with angle iron support |
| 120 | 300 x 50 x 1.25mm With 25x25x3mm with angle iron support |
| 121 | Supply & Fixing of perforated GI cable traybend as per GS. |
| 122 | 200 x 50 x 1.25mm |
| 123 | 300 x 50 x 1.25mm |
| 124 | Supply & Fixing of perforated GI cable tray Tee as per GS. |
| 125 | 200 x 50 x 1.25mm |
| 126 | 300 x 50 x 1.25mm |
| 127 | Supply & Fixing of perforated GI cable tray Cross as per GS. |
| 128 | 200 x 50 x 1.25mm |
| 129 | 300 x 50 x 1.25mm |
| 130 | Supply of LED full Glow High eficiency light fittings (Make:- Philips, Cat. No. RC380B LED36S-6500 G5 L60W60 PSU OD / Lighting Techonology/ wipro having similar specification). |
| 131 | Supply ofSingle industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 502P 1xT-LED22W P3241/Wipro having similar specification). incl S&D 1x 18/20 watts 4 ft LED tube lamp (Make:-Philips, Cat. No. - Mas LED tube 1200 mm 18W865 T8 I/Wipro/ Lighting Techonolog) having similar specification). |
| 132 | Supply of Twin industrial box(thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 502P 2xT-LED22W P3241 / Wipro having similar specification) incl. S & D 2x 18/20 watts 4 ft LED tube lamp (Make:-Philips, Cat. No. - Mas LED tube 1200 mm 18W865 T8 I / Wipro Lighting Techonolog) having similar specification). |
| 133 | Fixing only Recessed type 34/36 Watt 2\" X 2\" LED down light on existing grid type false ceiling incl. necessary connection as required. |
| 134 | Fixing only single/twin LED light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener. [Schedule Item 14.b / C - 2] |
| 135 | Fixing only single/twin LED light fitting suspended 25 cm bellow the ceiling with 2 Nos. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S & F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5Sq.mm.) flexible copper wire of 1.10 mt. length. |
| 136 | S & Delivery of240 V, . Sweep AC. BLDC Ceiling Fan complete with blades, canopy,fork, ruber bush etc.incl. Departmental letters engraved on the body as per direction of EIC.but without regulator in following sizes :( Make :Crompton Energion HS 1200 mm (48 inch)/Orient ) |
| 137 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 138 | Supply of Heavy Duty Exhaustfanscomplete with all accessories having the following(Make - EPC) |
| 139 | 9\"(230mm) Speed 1370 RPM. |
| 140 | 12\"(300mm) Speed 1420 RPM. |
| 141 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: |
| 142 | (9\") |
| 143 | (12\") |
| 144 | Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) |
| 145 | Exhaust fan (9\"/12\") |
| 146 | Fixing only SPN Timer DB (4 to 16 way) on flat iron frame on wall |
| 147 | S& Fixingonly 18\" (450mm) full metal body wall Bracket Fan complete with all accessoriesto be fixedonwallinclu.Makingnecesy.Connection asper direction oftheEIC (Make- E.P.C.Electrical Pvt. Ltd., Tempset). |
| 148 | S/F 250 V 25 A dual timer controlled dual starter for controlling Double Air Conditioning machine in SS double door 12 way DB enclosure (LK/ABB/Siemens make) with S/F folling electrical accessories & front door locking arrangement with all connections by finishing the ends of 2 x 4 + 1 x 2.5 sq mm copper wire with dowells solderless socket by crimping method as to GS incl. earhing attachment on wall incl. necessary connection as per direction of EIC - a) 25 A DPMCB (LK Cat No - B20250C) - 1 no, b) 24 Hr programmable Digital timer (LK Cat No: 67DDT0) - 1 no, c) 3 pole power contactor (LK Cat No - MNX22/230 V) - 2 nos, d) 2 module AC motor starter (Legrand Myrius Cat no - 673031) - 1 no, e) 1 module 10 A Modular switch (Legrand Myrius) - 1 no, f) 3 module cover plate (Legrand Myrius) - 1 no, g) LED indicator lamp (LK) - 2 no, h) outgoing connector (aproved reputed make) - 2 nos, i)25 A Auto-Off-Bipass DPDT toggle switch - 2 nos to be fixed on iron frame. |
| 149 | S & F 250V 25A Timer controller for single AC machine in SS double door 8-way DB enclosure (Make:- LK, encloser cat no DBSPN012DD) or equvalant) with S&F following electrical accessories & front door locking arrangement with all connection by finishing the ends of 2x4 & 1x2.5 copper wire dowells solderless socket by crimping method as to GS earthing attachment on wall incl necessary connections as per direction of EIC :-i) 20A DPMCB (LT make cat no B20250C) --- 1 Noii) 24 Hr programmable Digital/Analog Timer (LT make cat no 67DDT0) ---- 1 Noiii) 3 pole power contractor (LT make cat no MNX 22/230V) with 1 NO +1 NC additional contact block ---- 1 setiv) 2 Moduler AC motor stater (Legrand/Myrius) ---- 1 No.V) 2 Module plate with cover (Make :-Legrand/Myrius) -- 1 Novi) 20A Auto-Off-Bipass SPDT toggle switch (approved/reputed make) ---- 1 No.vii) 10A SPST Moduler typeswitch (Make :-Legrand/Myrius) - 1 No.viii)Outgoing connector make ELMAX (approved/reputed make) - 1 No |
| 150 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By TATA-Medium GI pipe |
| 151 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe |
| 152 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required |
| 153 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damagesNo. 4 SWG |
| 154 | Add GST @18% |
| 155 | Add LWC @1% |
| 156 | Less: Cost of old wornout panels and other accessories including old cut piece cables, panel supports and guarding cages etc. - Rs. 15,000/- |
| 157 | Defect Liability Period - 1 (One) year |
| 158 | Make and model to be approved by EIC |