| 1 | Cleaning/clearing ofmanholeof any description and any size and removing sludge and accumulated solid/semi solidswith proper equipment and washing down with water for smooth functioning of sewage line and manhole all as specified and directed.Waste obtained shall be removed to a distance exceeding 250 M away from unit lines and burried in ground including necessary excavation, earth work andspreading of bleaching powder, complete all as specified and directed by Engr in Charge. |
| 2 | Cleaning / clearing of blocked WC / EWC of any type and description including removalof soil, waste and vent pipes by using rubber cup 125mm dia with wooden handle, rodding or with gunny bags and clearing the blockage upto 1st manhole with cleaning rod including removal of all materials from traps of WC, complete all as specified and directed by Engr in Charge. |
| 3 | Cleaning / Clearing of Nahani traps, floor traps and gully traps of any description, any size any depth and removing sludge and accumaulated solid / semi solis with proper equipment and washing down with water for smooth functioning of sewage line, nahani traps and floor traps all as specified and directed.Waste obtained shall be removed to a distance exceeding 250m away from unit lines and burried in ground including necessary excavation, earth work and spreading of bleaching powder, complete all as specified and directed by Engr in Charge. |
| 4 | Cleaning / desludging of existing septic tank of10 to 50 users and any depth including taking out and removing sludge and accumulated solids/ semi solid contents in closed container at a place 250 m away from defence land and burried in ground including necessary excavation, earth work and spreading of spreading of bleaching powder complete all as specified and as directed.Note :- (i) The cleaning of septic tank shall be carried out mechanically using apropriate technological appliances. |
| 5 | Cleaning of existing sewer lines of dia 100 to 200 mm, any depth not exceeding 2.50 m deep by rodding manually or mechanically as required at site including manholes, inspection chamber, testinig after cleaning and getting out sludge and accumulated solids / semi solids from connecting manholes / lines, removing the sludge / spoil minimum 250 mtrs away from MOD land and refixing the manhole cover etc, complete all as specified and directed. |
| 6 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, manholes etc not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified and as directed |
| 7 | Demolition and breaking up drain pipes , 100/110 mm dia (PVC 150 mm bore/ Salt glazed stone ware, AC or Reinforced concrete) set in cement mortar or fixed with wall complete all as specified. |
| 8 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced) complete all as specified and directed. |
| 9 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soil of any description, complete all as specified and as directed.. |
| 10 | Removing excavated soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.5m above the starting point, complete all as specified. |
| 11 | M&L for PCC 1:4:8 type D-2, (Using 20 mm graded stone aggregate) as in bed of drain for 100mmbore pipe incl packing under and haunching against the sides of pipes after they are laid in and tested complete all as specified and directed. |
| 12 | S&F PVC (SWR) pipes 110mm diasingle socketed, in any length with rubber ring joints,laid in floor, or in trenches, complete all as specified and as directed |
| 13 | S&F in repair PVC (SWR) pipes 110mm diasingle socketed, in any length with rubber ring joints, fixed on walls or floors and spout pipe of retaining wall complete all as specified and as directed |
| 14 | S&F in repair PVC (SWR) pipes75mm diasingle socketed, in any length with rubber ring joints, fixed on walls or floors complete all as specified and as directed |
| 15 | S&F in repairPVC (SWR) vent cowl 75mm dia pipe complete all as specified anddirected. |
| 16 | Demolition of reinforced cement concrete cover slab for manhole /spetic tank and removing the debris to a distance not exc 500 M as directed. |
| 17 | M & L precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregatefor cover slab for Man holes/Septic tank set in CM 1:6 complete all as specified and directed. |
| 18 | M&L for mild steel deformed bars or TMT bars10mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 19 | M&L for PCC 1:2:4 type B-2 (using 40mm graded stone agg) as in surface channel, drain and manhole including finishing complete all as specified and directed. |
| 20 | Extra for forming fair finished drain channel 30cm inner girth in cement concrete using extra cement includingforms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 21 | Demolition of PCC block masonary, stone /boulder masonry, built in any type of cement mortar including all quoins, arches, pillars, etc., but including ashlar facings, dressed stonework and precast concrete articles.complete all as specified and directed. |
| 22 | M & L for Precast cement concrete 1:3:6 type C-1, (20mm graded crushed stone aggregate) block masonarywith solid blocks built in cement mortar 1:6 complete all as specified and directed. |
| 23 | M&L for walling of random rubble stone masonry uncourced well bonded bedded and solidly hearted built in CM 1:6 complete all as specified and as directed |
| 24 | Ditto as per item 23 abve butexcept stone complete all as specified. |
| 25 | M&Lprecast PCC 1:3:6 type C1 using 20mm graded stone agg as in bond stones set in cement mortar 1:6 complete all as specified and as directed |
| 26 | M&L PCC 1:2:4 type B-1 using 20mm graded stone agg as in coping to retaining wall / drains / manholes complete all as specified and directed. |
| 27 | M & L for Raised pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:3 complete all as specified and directed. |
| 28 | Taking down cement plastering at any description on brick or stone wall etcincluding rakingout joints hacking for key scrubbing down with water etc and removal of debries and depositing where directed. |
| 29 | M & Lrendering 15mm thick on fair faces of stone/concrete work in CM 1:4 incl finished even and smooth without using extra cement complete all as specified and directed. |
| 30 | M & L for Preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls over one coat of primer complete all as specified and directed by Engr in charge. |
| 31 | M & L for preparation of old plastered surface or prefeb shelter walls and applying two coat of cement base paint complete all as specified and directed. |
| 32 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as directed. |
| 33 | S & F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 34 | S & F in repairs galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc (each line wire to be measured) complete all as specified and directed. |
| 35 | Restraining & resecuringinclduing making good staples of galvanised steel barbed wire of any description and any type complete all as specified and directed. |
| 36 | M & L for preparation of new or previously untreated surfaces of steel of any description , over 10 cm in width or girth not otherwise described applying two coats of synthetic enamel paintover a coat of red oxide primer complete all as specified and directed. |
| 37 | M & L for preparation of old of steel of any description, over 10 cm in width or girth not otherwise described applying one coats of synthetic enamel paintcomplete all as specified and directed. |
| 38 | PCC (1:3:6)type C2 using 40 mm graded agg as in foundation mass concrete complete all as specified and directed by Engr in Charge. |
| 39 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engineer-In-Charge. |
| 40 | S & F Steel work in tubular trusses/purline including special shapewasher etc. complete using ERW or induction butt weldedtubes conforming to IS.1161-1979 grade St.-240 Complete all as specified and as directed by Engr-in-charge. |
| 41 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coveringscomplete all as specified and directed. |
| 42 | M & L Prepainted galvanume aluminium zine coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strenght 550 Mpa in roof coverings fixed with self tapping screws Complete all as specified and as directed by Engr-in-charge. |
| 43 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover filletscomplete all as specified and directed. |
| 44 | S & F of 5 mm thickness colour wall lining / panelling PVC sheet, solid sheet inclusive of solvent cement and fixing at site,for wall paneling /lining inclusive of fixing on walls over and incl PVC fillet 35 mm thick fixing of wall including corner on edges of openingas per specification etcdirected. |
| 45 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 46 | M&Lscreed bed or bedding layer of morter 15 mm thick cement plaster 1:6 for laying floor finished to receive floor tiles/chequred tiles or granitecomplete all as specified and directed. |
| 47 | M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc. complete all as specified and directed . |
| 48 | All as per item No19 above but as in skirting / daddo and pointed in white or coloured cement to match over backing coat 10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 49 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 50 | M&L for 50 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair all as specified. |
| 51 | M&L for chequered cement concrete tiles25 mm thick, with grey cement andpigments, set, jointed and pointed in neat cement slurry in floors complete all as specified and as directed. |
| 52 | M & L for providing, cement concrete Type B-1,1:2:4 (20 mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed. |
| 53 | S & Fixed in repair door closer hydraulically regulated designation No 3, universal type suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kgs of aluminium extruded section complete all as specified and directed. |
| 54 | M & L fixed in repair for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed. |
| 55 | Taking down door chowkhat with shutter area n-exc 1.5 Sqmeach(without taking off shutters from the frame) complete all as specified & directed. |
| 56 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening as per specification and shown in drg in SSR Part -II 2020complete all as specified and directed. |
| 57 | S&F factory made solid panel PVC door shutter 30mm thick consisting of frame made out of MS frame shall be covered with heat moulded plain cover PVC C channel having a PVC sheet strip of 20mm with struck in side with solvent cement for styles and plain colour PVC sheet for top rail lock rail and bottom rail and either side as gap inserted for top rail and bottom rail panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the styles and rails with suitable PVC sheet beading sheet and jointed together with solvent cement in frame at site as per specification andshown in drg in SSR Part -II 2020complete all as specified and directed. |
| 58 | S&F 150 mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and directed . |
| 59 | S&F 100mmlong Butt hinges, extruded aluminium alloy with galvanisedmild steel hinge pin, anodisedand fixed, type B-22 complete all as specified |
| 60 | S&F 150 mm long aluminium anodised handle fabricatedtype complete all as specified and as directed by Engineer-In-Charge. |
| 61 | M&L for 4mm thick sheet glass ordinary quality and glazing with oil putty in square n-exc 0.5 sqm in each pane incl hacking out old broken glass (any thickness, size quality or description) from wooden frames or stone, concrete or brick surrounds complete complete all as specified . |
| 62 | Supply & fixed (in repair) vitreous china wash down water closet pedestal pattern (EWC) , White including connection to trap and to flushing pipe with ‘P’ or ‘S’ trap, making good to floor, plastic water closet seat cover with mild steel chromium plated hingescomplete all as specified |
| 63 | S & F in repairs PVC valveless, syphonic action type, flushing cistern of 10 ltrs capacity, high or low level, white, with inlet, ball valve, float and handle including brackets, and connections to flush pipes of polyethylene of low or high density ,complete all as specified and directed. |
| 64 | S&F in repairs for Wash basins, Vitreous China (flat back or angle back type) size 580X450mm, including cutting for and pinning in ends of brackets or erecting stand but inclusive of fixing of supply and waste pipe , complete all as specified and as directed. |
| 65 | S&F in repairs mirror glass of size 0.60X0.450m bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with cromium plated brass screw and cup washer etc complete all as specified and as directed. |
| 66 | S&F in repairCP Stop cock/ Angle cock 15mm fancy type choromium plated etc, complete all as specified and as directed. |
| 67 | S&Fin repairs15 mm dia pillar taps cast copper alloy capstan heads, chromium plated, screwed down high pressure with or without lettered hot or Cold with long screwed shank and fly nuts screwed for iron pipe and fixed complete all as specified and direrected. |
| 68 | S&F in repairs 15 mm diabib taps cast copper alloy , choromium plated ,with crutch or butter fly handle screwed down screwed for iron pipe etc complete 15mm dia complete all as specified . |
| 69 | S&F in repairs PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed. |
| 70 | S & F in repairs 15 mm dia brass CP wall mixture for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and directed |
| 71 | S & F in repair15 mm dia concealed type Stop valves,chromium plated with long shank and cup screwed both ends for iron pipe or for unions and fixed. complete all as specified and directed |
| 72 | M&L in repair32mm dia bore waste fittings, brass, chromium plated for glazed ware sinks, basins, etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement complete all as specified and directed |
| 73 | M&L for rotational moulded polyethylene water storage tank 1000 ltrs capacity tripple layered cylindrical vertical with closed top hoisted and fixed in position including fittings incl dismantling of oldPVC water tanks and removing from site all as specified and as directed. |
| 74 | S & F in repair for Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 75 | Schedule of Credit |