| 1 | Supplying, laying, fixing, jointing and testing LT under ground XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm, 4 Core, IS 7098 marked, with electric connection lugs, laid in trenches/under floor or fixed naked with walls / on poles/ in ducts / in GI pipes etc. and including taking down existing cable, complete all as specified and directed.Note - Excavation, earth work, sand cushioning, cable cover and GI pipe shall be measured and paid separately. |
| 2 | Ditto all as per serial item No. 01 described here -in-before, but cross sectional area 4 Sqmm, 2 Core, complete all as specified and directed. |
| 3 | Ditto all as per serial item No. 01 described here -in-before, but cross sectional area 25 Sqmm, 4 Core, complete all as specified and directed. |
| 4 | Ditto all as per serial item No. 01 described here -in-before, but cross sectional area 35 Sqmm, 3.5 Core, complete all as specified and directed. |
| 5 | Ditto all as per serial item No. 01 described here -in-before, but cross sectional area 50 Sqmm, 3.5 Core, complete all as specified and directed. |
| 6 | Ditto all as per serial item No. 01 described here -in-before, but cross sectional area 70 Sqmm, 3.5 Core, complete all as specified and directed. |
| 7 | Ditto all as per serial item No. 01 described here -in-before, but cross sectional area 95 Sqmm, 3.5 Core, complete all as specified and directed. |
| 8 | Ditto all as per serial item No. 01 described here -in-before, but cross sectional area 120 Sqmm, 3.5 Core, complete all as specified and directed. |
| 9 | Ditto all as per serial item No. 01 described here -in-before, but cross sectional area 150 Sqmm, 3.5 Core, complete all as specified and directed. |
| 10 | Ditto all as per serial item No. 01 described here -in-before, but cross sectional area 185 Sqmm, 3.5 Core, complete all as specified and directed. |
| 11 | Supply and laying GI pipe \"light grade\" 40 mm bore in trenches, under floors, roads, along poles for protection of cables with all necessary fittings and sealing ends, complete all as specified and directed. |
| 12 | Ditto all as per serial item No. 11 described here -in-before but GI pipe \"light grade\" 50 mm bore, complete all as specified and directed. |
| 13 | Ditto all as per serial item No. 11 described here -in-before but GI pipe \"light grade\" 80 mm bore, complete all as specified and directed. |
| 14 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cable, pipes etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 15 | Ditto all as per serial item No. 14 described here -in-before but depth exc 1.5m and n.exc 3m, complete all as specified and directed. |
| 16 | Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed. |
| 17 | Removing of excavated surplus soil to a distance not exc 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.. |
| 18 | M&L for locally available river sand in trenches below and above / around UG cable for cable protection, in duct under & above the cables including punning around cable, complete all as specified and directed.Note - Punned thickness shall only be measured and paid. |
| 19 | Supply and laying unreinforced PCC Cable protection cover, class LV, type-1 flat with size 250 x 150 x 40 mm laid flat width wise, complete all as specified and directed. |
| 20 | S&F in replacement of unserviceable Straight through LT joint including jointing material and excavation upto 3mtr length and depth as required at site and making good surface after jointing of cable complete of size 95 to 120 sqmm 3.5 core, complete all as specified and directed. |
| 21 | S&F in replacement of unserviceable Straight through LT joint including jointing material and excavation upto 3mtr length and depth as required at site and make good surface after jointing of cable complete of size 150 to 185 sqmm 3.5 core, complete all as specified and directed. |
| 22 | S&F MCCB 4 pole 63 Amps breaking capacity 25 kA,including spreader link and taking down old existing MCCB, complete all as specified and directed. |
| 23 | S&F MCCB 4 pole 100 Amps breaking capacity 25 kA, including spreader linkand taking down old existing MCCB, complete all as specified and directed |
| 24 | S&F MCCB 4 pole 160 Amps breaking capacity 36 kA,including spreader linkand taking down old existing MCCB, complete all as specified and directed |
| 25 | S&F MCCB 4 pole 200 Amps breaking capacity 36 kA, including spreader link and taking down old existing MCCB, complete all as specified and directed |
| 26 | S&F MCCB 4 pole 250 Amps breaking capacity 36 kA,including spreader link and taking down old existing MCCB, complete all as specified and directed |
| 27 | S&F MCCB 4 pole 400 Amps breaking capacity 36 kA,including spreader link and taking down old existing MCCB, complete all as specified and directed |
| 28 | Supply and fixing in replacement Onload Change over Switch cubical type 4 pole of rating 630 Amps,with rotary handles, complete all as specified and directed. |
| 29 | Supply and fixing in replacement offload Change over Switch cubical type 4 pole of rating 400 Amps,with rotary handles, complete all as specified and directed. |
| 30 | Supply and fixing in replacement offload Change over Switch cubical type 4 pole of rating 250 Amps,with rotary handles, complete all as specified and directed. |
| 31 | Supply and fixing in replacement offload Change over Switch cubical type 4 pole of rating200 Amps,with rotary handles, complete all as specified and directed. |
| 32 | M&L for spraying chemical (Glycol /roundup andchemical composition Isopropyl amine salt of glyphosate a.i.-40.60%, surfactant inert polyoxy ethylene amine 15.00 % & manufacturing Impurities 4.00% ) on area to remove unwanted vegetation / grass at various locations as directed.Notes - 1. Ouoted rate shall be inclusive of labour and equipments to spray chemical on required area.2. Spray will be repeated quarterly or as per the directions of Engr-in-Charge. |
| 33 | Supply and lay new sub class \"B\" bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed. |
| 34 | Supply, installation, testing and commissioning LT Panel board suitable for 415 Volts, 3 Phase 4 wire, 50 Hz AC supply systemoutdoor type floor mounted along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick with ingress protection of IP-54 grade having aluminium bus bar of rating 400 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The panel shall be front openable and having inner & outer shells. The inner shell duly compartmented for each control gear, including powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements. The size of the outer shell should not be less than 1200mm x 1200mm x 450mm, mounted on angle iron stand made out of angle size 50 x 50 x 6mm grouted in PCC foundation in cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), including accommodating the following control gears and accessories:-(a)MCCB 250 Amps 4 pole 25kA 415 volts, (incoming) – 01No (b) MCCB 125 Amps 4 pole ,16 kA 415 Volts (out going ) -03 Nos(c) MCCB 63 Amps 4 pole ,16 kA 415 Volts (out going ) -01 No(d) Aluminium Bus bar of capacity 400 Amps 3phase and neutral -1 set.(e) Digital type voltmeter0-500 volts - 01 No.(f) Digital type Ammeter with CT of suitable ratio for reading upto 400 amps load-01 No(g) Indicating LED lamps R,Y& B -01 setNote: (i) Before placing the oder of material drawing of LT panel shall be submitted by contractor for approval of GE.(ii) Quoted rate shall be inclusive of dismantling old LT panel. |
| 35 | Supply and fixing in replacement of LT switch gear 440 Volts, 3 phase, 4 wire, 50 cycles, Air circuit breaker, cubical manual drawout type complete with microprocessor release of capacity rating up to 800 Amp, 50KA. The protection relays should be provided with inbuilt short circuit protection, overload protection, instantaneous protection (IPR), ground fault protection andfunctional blocking, The ACB should have been designed for an operating voltage upto 690 volts. The rated insulated voltage (UI) should be 1000 volts and the rated impulsive voltage (UMP) should be 12KV including sheet enclosure and mounted arrangement etc, complete all as specified and directed. |
| 36 | M&L for painting of steel tubular pole upto 09 mtrs length including clamp, bracket and junction box with two coats of aluminium paint after preparation of old painted surface and providing 03 Nos. alternate strip of 30 cm wide with black and white super quality enamel paint above embedded level and writing pole No. with 02 inch wide letter complete all as specified and directed. |
| 37 | M&L for earthing completewith galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to galvanized earth strip 32X6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-Iand specified includingprovision of earth wire protected by 40mm dia light grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation andearth work & connecting the earthing to an earthing test point /DG Set nuetral/body/ Lt panel etc. and testing on completion, complete all as specified & directed. |
| 38 | S&F in replacement aluminium busbar 400 Amp capacity, colour code with neutral including200 Amp MCCB three phase and neutral with enclosure including fixing arrangement with breaking capacity 36kA, complete all as specified and directed. |
| 39 | Supply and Erecting in vertical position steel tubular swaged pole type 410 SP-31 (9 metre long) with 300mmx300mm x6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5M from ground level/coping and making 30cm black and white strips with two coats of super enamelled paint up to 1.5M from ground level/coping including taking down/ dismantling of old steel pole complete all as specified and directed.Note:- Earthwork and concrete shall be measured and paid saparatly under respective items. |
| 40 | M&L for Cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint after preparation of surface, including dismantlig old cross arms complete all as specified and directed. |
| 41 | Supply, fixing, jointing and testing 1100 volt grade aluminium solid conductorcablewith pvc armouredtape and overall pvc sheathed 6 sqmm 2 corenominal cross section in service connection, including taking down old cable complete all as specified and directed. |
| 42 | Supply, fixing, jointing and testing 1100 volt grade aluminium solid conductorcablewith pvc tape armouredtape and overall pvc sheathed 10sqmm 2corenominal cross section in service connection, including taking down old cable complete all as specified and directed. |
| 43 | S&F in replacement Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and onegalvanisedironnut, 100mm height, 65mm dia for1100 volts grade complete all as specified and directed |
| 44 | S&F in repair/ replacement stay assembly complete having stay rod 16mm dia with accessories as shown in electrical plate No. 1 (including loop type insulator, stay clamps) complete all as specified and directed.Note:- Earthwork and concrete shall be measured and paid saparatly under respective items. |
| 45 | Material and labour for galvanised stay strand 7/4mm dia suitable for stay assembly including dismantling old one complete all as specified and directed. |
| 46 | Supplying and fixingLT MS cable route indicator, engraved the description on the disc not less than 6\" dia welded with40 x 6 mm MS Strip of approximate length 90 cm duly painted on all steel parts as per colour code and provision of PCC (1:4:8), type D-2 (using 40 mm graded crushed stone aggregate) of not less than 0.05 cum in each at base buried under the ground including necessary earth work, including taking down old cable route indicator complete all as specified and directed. |
| 47 | Supply and use electrical insulation tape roll of 25mm wide and 20 Mtr length (RYB) in repair/maintenance of cables joints or fixing of thimbles or colour coding of cables in panels/joints etc, complete all as specified and directed. |
| 48 | Supply & laying in replacement of PVC insulated armoured round sheathed copper conductor cable 4 sqmm size2 core, complete all as specified and directed. |
| 49 | M&L for Stretching of Over head line four conductor with street light feeder completein cantt area including fixing of spacer in between four conductor for maintaining clearance and to beavoid fault on over head lines, complete all as specified and directed. |
| 50 | Trimming of tree branches touching with LT over head line in the entire cantonment so as to maintaining sufficient clearance and avoid fault on over head lines, complete all as specified and directed. |
| 51 | Notes :-An amount of Rs. 1,55,140.00 on account of Credit Schedule for Schedule \"A\" Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum. |