| 1 | A) Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area & stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means SSR OF 2022-23 ITEM NO. 21.02 & PAGE NO.197 Bd.A.1 Page No. 115. |
| 2 | B) Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area & stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means SSR OF 2022-23 ITEM NO. 21.02 & PAGE NO.197 Bd.A.1 Page No. 115. |
| 3 | Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterialupto distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringandstruttingetc.complete.(Liftupto1.50m)ByMechanical Means Bd.A.2 Page One Number 259 SSR of 2022-23 ItemNo. 21.06 and page No. 115 |
| 4 | A) Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade) Bd. E. 1 Page No. 287 SSR OF 2022-23 ITEM NO. 24.01 & PAGE NO.131. |
| 5 | B) Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade) Bd. E. 1 Page No. 287 SSR OF 2022-23 ITEM NO. 24.01 & PAGE NO.131. |
| 6 | A) Providing and laying in situ/Ready Mixcement concreteM-20of trap / granite /quartzite/ gneissmetal for R.C.C. workin foundations like raft, strip foundations, grillage andfootings of R.C.C. columns and steel stanchionsetc. including bailing out water, formwork, laying/pumpingcover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade finely washed etc) Bd.F.3 Page No. 298 and B.7, Page No.38 SSR OF 2022-23 ITEM NO. 25.11 & PAGE NO.178. |
| 7 | B) Providing and laying in situ/Ready Mixcement concreteM-20of trap / granite /quartzite/ gneissmetal for R.C.C. workin foundations like raft, strip foundations, grillage andfootings of R.C.C. columns and steel stanchionsetc. including bailing out water, formwork, laying/pumpingcover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade finely washed etc) Bd.F.3 Page No. 298 and B.7, Page No.38 SSR OF 2022-23 ITEM NO. 25.11 & PAGE NO.178. |
| 8 | A) Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc.complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)SSR OF 2022-23 ITEM NO. 25.31 & PAGE NO.179. |
| 9 | B) Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc.complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)SSR OF 2022-23 ITEM NO. 25.31 & PAGE NO.179. |
| 10 | A) Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)Bd.F.6 Page No. 300 and B-7, Page No. 38. SSR OF 2022-23 ITEM NO. 25.5 & PAGE NO.181 |
| 11 | B) Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)Bd.F.6 Page No. 300 and B-7, Page No. 38. SSR OF 2022-23 ITEM NO. 25.5 & PAGE NO.181 |
| 12 | A) Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade ) Bd.F.9 Page No. 303 and B.7, Page No.38 SSR OF 2022-23 ITEM NO. 26.05 & PAGE NO.184. |
| 13 | B) Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade ) Bd.F.9 Page No. 303 and B.7, Page No.38 SSR OF 2022-23 ITEM NO. 26.05 & PAGE NO.184. |
| 14 | A) ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/ quartzite/ gneiss metal for R.C.C.slabs andlandingsasper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) SSR of 2022-23 Item No. 25.7 and page No. 182. |
| 15 | B) ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/ quartzite/ gneiss metal for R.C.C.slabs andlandingsasper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) SSR of 2022-23 Item No. 25.7 and page No. 182. |
| 16 | ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-20oftrap/quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawingsorasdirectedincludingsteelcentering, formwork,steelprops,laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) SSRof 2022-23 Item No. 26.17 and page No. 185. |
| 17 | A) Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Bd.F.17, Page No. 306 SSR OF 2022-23 ITEM NO. 26.33 & PAGE NO.188 |
| 18 | B) Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Bd.F.17, Page No. 306 SSR OF 2022-23 ITEM NO. 26.33 & PAGE NO.188 |
| 19 | A) Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. Bd.G. 1 Page No. 313 SSR of 2022-23 Item No.27.01 and page No. 197. |
| 20 | B) Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. Bd.G. 1 Page No. 313 SSR of 2022-23 Item No.27.01 and page No. 197. |
| 21 | A) Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineer inchargein layers of 15cm. to 20cm.including watering and compaction etc. complete.Bd.A.11 Page No. 263 SSR OF 2022-23 ITEM NO. 21.37 & PAGE NO.157. |
| 22 | B) Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineer inchargein layers of 15cm. to 20cm.including watering and compaction etc. complete.Bd.A.11 Page No. 263 SSR OF 2022-23 ITEM NO. 21.37 & PAGE NO.157. |
| 23 | A) Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Bd.G.5 Page No. 315 SSR OF 2022-23 ITEM NO. 27.05 & PAGE NO.144 |
| 24 | B) Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Bd.G.5 Page No. 315 SSR OF 2022-23 ITEM NO. 27.05 & PAGE NO.144 |
| 25 | Providing and fixing steel window C.R.C. sheet as per I.S. 1513 : 1986. gauge sect. 65 x 40 x 25 mm shutter single sheet of 24 gauge single leaf joinedby fusion welding at appropriate points with vertical grooves of 15 mm wide and 15 mm deep at a distance of 45 mm. The first andlastribshouldbe60mmawayfromverticaledgeoftheshutter.theshuttershallbe welded, with angle to from the periphery of the shutter. At the center of the frame there shall beangleweldedtobifurcatetheframeintosegmentswithtwoleafshuttersquare12mm square guard bars at 120 mm center with all accessories As directed by Engineer in charge. SSR of 2022-23 Item No. 39.21 and page No. 181. |
| 26 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre asperdrawing including fixtures,necessarywelding andpainting withone coatsof anticorrosive paint and two coats of oil painting complete. SSRof 2022-23 Item No. 40.01 and page No. 264 Bd.U.1 Page One Number 537 |
| 27 | Providing and fixing steel frame of angle 50 x 50 x 6 mm size for window with 16 mm with mild steel bars horizontally at 10 cm c/c for ventilator portion and at 15 cm c/c for remaining portion with M.S. flat of size 40 x 6 mm vertical at center including iron hold fast boxes for fixing40x6mmverticalatcenterincludingironholdfastboxesforfixing40x6mm vertical at center including iron hold fast boxes for fixing shutters including welding finishing painting etc. complete. As directed by Engineer in charge. SSR of 2022-23 Item No. 39.33 and page No. 182. |
| 28 | Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two trackswithrectangularpipe having overalldimension63.50x38.10x1.02mm atweight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm atweight0.695Kilogram/One Running Metre.Topandside track section61.85x31.75x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Runningmetre.AsperdetaileddrawingsandasdirectedbyEngineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box. SSR of 2022-23 Item No. 39.39 and page No. 252. As directed by engineer-in-charge. |
| 29 | Providing and fixing M.S. grill door 24 Kilogram/ One Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etcAs directed by Engineer in charge. SSR of 2022-23 Itemno. 39.31 and page No. 182. |
| 30 | Providing and fixing steel frame door of angle 50 x 50 x 6 mm with mild steel bars 16 mm dia. horizontally at 10mm c/c for ventilator portion including iron hold fast boxes for fixing shutters including welding, finishing, painting etc. complete.As directed by Engineer in charge. SSR of 2022-23 Item No. 39.35 & page No. 250. |
| 31 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:5without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Bd. L.2 Page One Number 368 SSR of 2022-23 Item no. 32.03 and paeg No. 153. |
| 32 | Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain/ obscuredglass panels of approvedtype andquality, iron oxidised fixtures and fastenings, oil painting two coats complete. BD-T-53Page One Number 509 SSR of 2022-23 Item No. 39.19 and page No. 247. |
| 33 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positionsincludingbasecoatof15mmthickincementmortar1:4usingwaterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping thesurfaceofthebasecoatroughtoreceivethesandfacedtreatment6to8mm thickin cementmortar1:4finishingthesurfacebytakingoutgrainsandcuringforfourteendays scaffolding etc.complete.Bd.L.7 Page One Number 369 SSR of 2022-23 Item No. 32.11 |
| 34 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:5without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Bd. L.2 Page One Number 368 SSR of 2022-23 ItemNo. 32.03 and paeg No. 209. |
| 35 | A) Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. As directed by Engineer in charge.SSR of 2022-23 Item No. 32.34 and page NO. 212. |
| 36 | B) Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. As directed by Engineer in charge.SSR of 2022-23 Item No. 32.34 and page NO. 212. |
| 37 | A) Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of1:4cementmortarincludingneatcementfloat,fillingjoints,curingandclearing etc. complete. Bd.M. 12 Page One Number385 SSR of 2022-23 Item No. 33.4 & page No. 217. |
| 38 | B) Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of1:4cementmortarincludingneatcementfloat,fillingjoints,curingandclearing etc. complete. Bd.M. 12 Page One Number385 SSR of 2022-23 Item No. 33.4 & page No. 217. |
| 39 | Providingandapplyingprimingcoatonconcrete/masonary/AsbestosCementplastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.As directed by Engineer in charge. SSR of 2022-23 Item No. 35.21 and paeg No. 225. |
| 40 | A) Providingandapplyingexternalraincoatpaintingwithcrackfilling acrylicpolymerbased chemical compound coating to the external surface of walls to prevent water seepage in the masonry walls during monsoon added with required shade Steiner to give required shade to the surface in two coats. Including providing three coat of priming of polymer base primer including preparing surface scrapping the existing loose old paint, removing loose particles of sandonthesurfaceopeningandcleaningthecracksdevelopedintheexternalplaster, removinglooseparticlesbychiseling,fillingcracksbychemicalscompoundofapproved makewithproperpenetrationetc.CoatingofRaincoatwiththehelpofbrushandasper instructions andspecificationgivenby manufacturerandwithinstructionfrom Engineer in- charge. Work shall be executed by certified applicator only and covering gurantee of 3 years on court stamp paper of Rs. 500/- and necessary testing etc. complete.As directed by Engineer in charge. SSR of 2022-23 Item No. 35.29 and page No. 226. |
| 41 | B) Providingandapplyingexternalraincoatpaintingwithcrackfilling acrylicpolymerbased chemical compound coating to the external surface of walls to prevent water seepage in the masonry walls during monsoon added with required shade Steiner to give required shade to the surface in two coats. Including providing three coat of priming of polymer base primer including preparing surface scrapping the existing loose old paint, removing loose particles of sandonthesurfaceopeningandcleaningthecracksdevelopedintheexternalplaster, removinglooseparticlesbychiseling,fillingcracksbychemicalscompoundofapproved makewithproperpenetrationetc.CoatingofRaincoatwiththehelpofbrushandasper instructions andspecificationgivenby manufacturerandwithinstructionfrom Engineer in- charge. Work shall be executed by certified applicator only and covering gurantee of 3 years on court stamp paper of Rs. 500/- and necessary testing etc. complete.As directed by Engineer in charge. SSR of 2022-23 Item No. 35.29 and page No. 226. |
| 42 | Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two trackswithrectangularpipe having overalldimension63.50x38.10x1.02mm atweight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm atweight0.695Kilogram/One Running Metre.Topandside track section61.85x31.75x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Runningmetre.AsperdetaileddrawingsandasdirectedbyEngineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising with box. SSR of 2022-23 |
| 43 | Providing and Fixing mat finish stainless steel (of 302 grade ) railing with toppipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75mmdiameteretc.complete(PriorapprovalofsampleandbrandbyEx.Engineeris necessary before use)As directed by Engineer Incharge SSRof 2022-23 Item No. 40.08 |
| 44 | A) ROYALTY CHARGES :- Supply of Rubble, Murum, Soil, 60mm./40mm. metal (Hand broken), royalty charges are not included in the rates.[As per Govt. of Maharashtra, Revenue and Forest Departments Gazette No.146 Dt.04 June 2021 States that the royalty charges ofRs.211.95/Cu.M. ) are considered. The surcharge levied on Royalty shall also be payable to the contractor.E DSR ITEM NO. ... & PAGE NO.... A) For SAND |
| 45 | B) ROYALTY CHARGES :- Supply of Rubble, Murum, Soil, 60mm./40mm. metal (Hand broken), royalty charges are not included in the rates.[As per Govt. of Maharashtra, Revenue and Forest Departments Gazette No.146 Dt.04 June 2021 States that the royalty charges ofRs.211.95/Cu.M. ) are considered. The surcharge levied on Royalty shall also be payable to the contractor.E DSR ITEM NO. ... & PAGE NO.... A) For SAND |
| 46 | A) ROYALTY CHARGES FOR OTHER MINERALS |
| 47 | B) ROYALTY CHARGES FOR OTHER MINERALS |
| 48 | Laboratory testing charges are not considered in the Rate Abstracts. Where ever required separate item shall be taken in the estimate for material testing charges, on the basis of testing frequency and charges fixed by Vigilance & Quality Control Circle, for the current year and shall form part of tender.testing of material by Quality control and certified quality must be use by contractorA) BRICKS : Water, Absorption, Compressive Strength, Efflorescence (Set of 5 bricks) |
| 49 | B) Concrete : Compressive Strength of C.C.Cubes (Set of 3 cubes) |
| 50 | Laboratory testing charges are not considered in the Rate Abstracts. Where ever required separate item shall be taken in the estimate for material testing charges, on the basis of testing frequency and charges fixed by Vigilance & Quality Control Circle, for the current year and shall form part of tender.testing of material by Quality control and certified quality must be use by contractorA) CONCRETE : Compressive Strength of C.C.Cube (Set of 3 cubes) |
| 51 | B) FOR BRICKS |
| 52 | A) ADD 18% G.S.T |
| 53 | ADD 18% G.S.T |
| 54 | A) ADD 0.5% LABOUR INSURANCE |
| 55 | B) ADD 0.5% LABOUR INSURANCE |