| 1 | Demolition of brick work built in cement mortar including all quions, arches, pillars, etc complete all as specified and directed. |
| 2 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 3 | Boring holes 3m deep and 300 mm dia of pile in soil for Single under reamed piles and getting out and disposal of soil to a distance of n.exc 50m complete all as specified and directed. |
| 4 | Excavation in trenches in soft/ loose soil not exc 1.5m wide and not exc 1.5m deep for foundation, pier holes etc n. exc 10sqm on plan and getting out complete all as specified and directed. |
| 5 | M&L for Plain Cement Concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation, filling and mass concrete complete all as specified and directed. |
| 6 | M&L reinforced cement concrete M-25 design mix using 20mm graded crushed stone aggreagate as in foundation, footing, foundation beams, plinth beams, bases for columns, pedestal, under reamed piles, mass concrete, etc complete all as specified and directed. |
| 7 | M&L reinforced cement concrete M-25 design mix using 20mm graded crushed stone aggreagate as in columns, pillars, posts, struts etc complete all as specified and directed. |
| 8 | M&L reinforced cement concrete M-25 design mix using 20mm graded crushed stone aggreagate as in coping, beams, cantilevers, bressummers, Lintels over 1.5m span etc complete all as specified and directed. |
| 9 | M&L for Form work to sides of concrete foundations, footings, bases of columns raft, beam sides and soffits (if any) of foundations & plinth beams and similar wk etc rough finished surface of concrete complete all as specified and directed. |
| 10 | M&L for Form work to sides of pillars, posts, struts, piers, columns stachions flat with rough finished surface of concrete complete all as specified and directed. |
| 11 | M&L for Form work to sides of concrete floor or roof beams, beam haunchings, bressummers, lintels, cantilevers, shelves including supports overhangs etc also sprays between floor beams, etc on flat with rough finished surfaces of concrete complete all as specified and directed. |
| 12 | M&L mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cracking, bending, spirally for hopping for columns hookings ends and binding with and incl mild steel wire (annealed) not less the 0.9mm dia or securing with clips complete all as specified and directed. |
| 13 | The same as item No 12 above but 5 mm dia and over in stirrups, spacers and binders complete. |
| 14 | M&L for old size Brick work with sub- class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 15 | Taking down cement plaster on wall/ceiling/roof etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed. |
| 16 | M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6 complete all as specified and directed. |
| 17 | All as per item No 16 above but on other than fair faces. |
| 18 | M&L forapplying two coat of cement base paint on new plastered wall surfaces over a coat of primer incl preparation of surfaces etc complete as all specified and directed. |
| 19 | M&L Preparing old painted surfaces of walls, chajjas etc by washing rubbing down and stopping and applying two coat of cement base paint white or tinted complete all as specified as directed. |
| 20 | M&L for two coats of weather coat paint (apex) on old surfaces of wall including preparation of oldplastered surfaces complete all as specified and directed. |
| 21 | Returning filling in inclunding spreading levelling watering well raming in layers not exceeding 25 cm complete all as specified and directed. |
| 22 | Removingexcavated material to a distance exc 50m but n exc 150m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 23 | S&F MS angle Iron work as in fencing posts/angle horn and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc conforming to Fe 410-O or Fe 310-O complete all as specified and directed. |
| 24 | S&F Galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or typing at crossing with and provision of galvanised MS wire stapples or steel pins etc complete as all specified and directed. Note: Each line wire to be measured. |
| 25 | M&L for glazed ceramics coloured tiles of size 450x300x7mm thick on vertical surfaces such as skirting/dados/wall, etc over and including 10mm thick rendering in cmeent mortar (1:4) set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match the shade of tiles complete as all specified and directed. |
| 26 | S&F framed work as in doors or gates of angles or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering, Doors etc to be prepared for hanging or sliding with and incl either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete incl pintel hinges, stops hand made sliding bolts etc conforming to Fe 410-W (Gde-E-250) quality-A, complete all as specified as directed. |
| 27 | M & L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete as all specified and directed. |
| 28 | Demolition ofcement concrete of any description and in any position not otherwise specifically provided all as specified and directed. |
| 29 | M & L for Plain CementConcrete1:2:4 type B0(using 12.5 mm graded crushed stone aggregate) as incills, steps, parapets , copings,bound stone,bed plates, hold fastand the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 30 | Supply, stretch and fix concertina coil 600mm dia in stress position hot deep galvanised steel wire coated with CLR anti corrosive paints making diamond shape with the help of dove tail clips (18 SWG), the concertina coil is to be fixed with barbed wire at points where coil touched the bottom barbed wire with the help of lug rings (24 SWG) including all fittings like fastener clips, steel lug rings etc complete all as shown in drg all as specified and directed. Note: (i)Stretch length of each coil shall be 6 mtr. (ii)weight of each coil shall not be less than 9 Kg. |