Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-05-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 24-05-2025 |
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (un reinforced) as in roofs of existing water proofing treatment of any type and any thickness, complete all as specified and as directed. |
| 2 | M&L for applying bituminous primer conforming to IS -3384 @ 0.40 Kg/ Sqm on prepared surface on sunny day after the primed surface has dried and apply a coat of hot blown 85/25 penetration grade blown bitumen, confirming to IS -702@ 1.20kg/ Sqm on the surfaces. Provide APP (Atactic Polypropylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density firm. Minimum weight of membrance will be 3 kg/Sqm. APP membrance will be laid across the slope from lowest line sloping roof towards ridge with minimum end lap of 150 mm & side lap of 75mm bonded with hot blown bitumen. Over the APP membrance apply semi hot blown 85/25 penetration grade bitumen @ 1.20kg/ Sqm and blinded with fine sand in dry condition @ 0.50 kg/Sqm dusted over the bitumen coat.Note :- The laying of the membrane shall be got done by authorized applicator of the membrane manufacturer. |
| 3 | 20mm thick precast machine pressed factory made PCC tiles as in 1:2:4, type B-0 (using 12.5 mm graded crushed stone aggregates), 300x300mm size and 20mm thickness with grey cement & No pigment over and including a bedding layer of 15mm thick cement mortar 1:4 mixed with 5% creosote oil, joined & pointed flush in cement mortar 1:3 complete all as specified and as directed. |
| 4 | Preparation of newor previously untreated surface of any description exc 10cm width or girth and applying two coats of aluminium paint over a coat of primer complete all as specified and directed. |
| 5 | Demolition of stone slabs and tiles laid dry or dry bedded or pointed of any description or thickness in floors, aprons etc complete all as specified and directed by Engineer in charge |
| 6 | M & L Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like one piece full in cement mortar (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in CM 1:6 complete all as specufied and as directed. |
| 7 | Demolition of brick work or stone/boulder masonry built in cement mortar or cement limemortar including all quoins, aches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and as directed. |
| 8 | Brick work with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in CM 1:4 complete all as specified and as directed. |
| 9 | Taking down cement or cement lime plaster on brick or stone walls etc of any description including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed. |
| 10 | Rendering 15mm thick in two layers on fair faces of brick work or concrete surfaces in CM 1:4 mixed with water proofing compound @ 3% by weight of cement (cost of WPC is deemed to be included in quoted rate), finished even and smooth without using extra cement complete all as specified and directed. |
| 11 | Rendering 10mm thick plaster in cement mortar 1:6 on fair face of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and as directed. |
| 12 | Rendering 5 mm thick plaster in CM 1:4 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed. |
| 13 | Dismantlingfloor, heart or wall tiling including Cement Mortar bedding(but not backing) removing serviceable tiles to store and rubbish off the premisescomplete all as specified and as directed. |
| 14 | Non Skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:4) complete all as specified and directed. |
| 15 | Glazed ceramic coloured tiles 450mm x 300mm x 6 to 7 mm thick,sharp edged (joint free), in vertical surfaces such as walls, skirting etc , setto match over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 16 | Vitrified ceramic tiles 10mm thick (Square) polished, light shade, area of each tile n exc 0.36 sqmin floor etc, set and jointed in cement slurry and pointed in shite or coloured cement over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-charge. |
| 17 | Demolition of cement concrete (unreinforced) in ground floor and paving n.exc. 15 cm thickness (below or above ground level)complete all as specified and as directed. |
| 18 | 50mm thick, PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) in floor finished even & smooth with out using extra cementcomplete all as specified and directed. |
| 19 | 25mm thick PCC 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in floor base of tiles complete all as specified and directed. |
| 20 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 21 | Reinforced cement concrete, 1:1.5:3, type A-1 (using20 mm graded crushed stone aggregate) as in slab supported on walls, beams and columns in floor, roofs, landings, balconies, canopies, shelves and like complete all as specified and directed. |
| 22 | Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, floor and roof slabs and shelves, horizontal or sloping and similar workexc 5cmbutnot exc. 10cm wide complete all as specified and directed. |
| 23 | Use and waste of form work to soffits of suspended slabs such as floor slab,landings and similar work not exc 200mm thick in rough finish surfaces of concrete complete all as specified and directed. |
| 24 | Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 25 | Taking down chowkats or frames with shutters (without taking off shutters from frame) not exc 1.50 Sqm each including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out holdfasts shall be finished identical to existing finish without any extra cost to Govt.), complete all as specifiedand directed. |
| 26 | Taking down chowkats or frames with shutters (without taking off shutters from frame) exc 1.50 Sqm and not exc 4.00 Sqm each including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out holdfasts shall be finished identical to existing finish without any extra cost to Govt.), complete all as specifiedand directed. |
| 27 | Taking down shutter of any description exc 1 Sq.m and n.exc 2 Sq.m each complete all as specified and as directed. |
| 28 | S & F powder coated (of approved colour ) aluminium sections as in frame & shutter of doors/window,partitions as in sliding/ openable/ louvers/ fixed type with and including necessary rolling for smooth moving & locking arrangement, etc fixed to wall including, preparation of disturbed portion both side (internal & external surfaces of wall) match with existing surface treatment and all sides of aluminium frame shall be sealed with silicon sealent (inner/outer face) complete all as specified as directed by Engineer in Charge. |
| 29 | S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200 mm centre to centre , including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirementand direction of Engineer-in-charge. |
| 30 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beadscomplete all as specified and as directed. |
| 31 | Tinted sheet glass 4mm thick ordinary quality and glazing with any type of beading/oil putty in square n/exc 0.5 Sqm each pane complete all as specified and directed. |
| 32 | 4mm thick figured glass pin head type ordinary quality and size and in any tyupe of frame and glazing with oil putty(or beading) in square exc 0.5 sq.m in each panes complete all as specified and directed. |
| 33 | Checking of joinery (wooden/steel) iron/aluminium mongery, pelmet box, door springs etc requiring carpentry work and carrying out minor repairs such as tightening of screws/nails, minor adjustment of joinery, door /windows by means of planer/chisling etc. including petty repairs material like screws/nails, plug etc. to make it functional, complete all as specifiedand directed.Note : Any other mongeries used in work will be measured and paid separately |
| 34 | Repair to aluminium door or window of any size, shape and description including easing, cutting, drilling, including provn of parts such as rubber gasket, blanket cloth, cleats, etc to make door or window fully functional complete all as directed by Engr-in- Charge. Note : Any other mongeries used in work will be measured and paid separately |
| 35 | S&F in repair 18 mm thick prelaminated medium density fibre (MDF) boards, interior grade, prelaminated one side with decorative choice lamination and other side balancingwhite lamination fixed with screws as in cup board, shelves, kitchen cabinet, etc, complete all as specifiedand directed. |
| 36 | S&F in repairs ply wood grade BWR type BB, 12 mm thick fixed to timber frame work with nailsetc, complete all as specifiedand directed. |
| 37 | S&F in repairs drawer side channel of standard size and including roller for moving drawer, mild steel bright finish, or electrogalvanised, width of flap 30mm fixed in repair, complete all as specified for modular kitchen, complete all as specifiedand directed. |
| 38 | S&F in repairs stainless steel multipurpose bracket in wooden drawer/partitions for storing rations of various types made of 4mm dia stainless steel rods, fixed in side partitions etc fixed , complete all as specified for modular kitchen . |
| 39 | Fixing only existing stainless steel multipurpose brackets in wooden/drawer/partitions for storing rations of various type, complete all as specified and directed by the engr in charge. |
| 40 | S&F in repair Stainless steel zero crank hinges (auto) fancy type (with Euro concealed hinges) fixed to shutters in cupboards of standard size and shape for modular kitchen. Complete all as directed by Engr-in-charge. |
| 41 | Factory made solid PVC door frame of size 50mm x 47mm made out of 5mm wall nut colour PVC sheet reinforced with MS Square tube complete all as specified and directed. |
| 42 | Factory Made Solid PVC Moulded Door Shutter of wall nut colour, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and as directed. |
| 43 | S&F pressed steel frames 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified. |
| 44 | S&F pressed steel frames 165 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified. |
| 45 | 35mm thick factory made flush shutters, solid core construction, with block board, core and plywood face panel, commercial plywood on both sides, complete all as specified and directed. |
| 46 | M&L 35 mm Glazed and skeleton shutters, 2nd class H.W open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed by Engr-in-Charge. |
| 47 | S&F 100 mm long stainless steel butt hinges, medium weight, and fixed, complete all as specified and as directed. |
| 48 | S&F 150 mm long aluminium handles, cast type, anodised and fixed, complete all as specified and as directed. |
| 49 | S&F 150 mm long aluminium, anodised, barrel towel bolts of extruded section and fixed, complete all as specified and as directed. |
| 50 | All as per description of Ser item No. 49.00 herein before but 125 mm Size, complete all as specified and as dircted. |
| 51 | S&F aluminium alloy sliding door bolt 250 mm long with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and as dircted. |
| 52 | S&F floor door stoper of 140mm long of aluminium alloy body and tongue, anodised with hard drawn steel spring,complete all as specified and as dircted. |
| 53 | S&F in repairs 125 mm longaluminium anodised hasp and staple with mild steel hinge pin including boltsto hinge plate and fixed with screws, complete all as specified and as dircted. |
| 54 | S&F in repairs aluminium alloy sliding door bolt 250 mm long with hasp, staple ( bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and as dircted. |
| 55 | S&F in repairs 200 mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and as directed. |
| 56 | S&F in repairs mild steel cold rolled butt hinges medium weight 100 mm long fixed to pressed steel/angle iron frames by welding, complete all as specified and as directed. |
| 57 | S&F in repairs 40 mm dia cup board knobs, brass polished, fixed with nut, screws and washer of mild steel, complete all as specified and as directed. |
| 58 | S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples , complete all as specified and as directed. |
| 59 | S&F in repairs stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mmand fixed with stainless steel wire staples, complete all as specified and as directed. |
| 60 | S&F in repairsPVC bathroom cabinets quality as approved by Engr-in Charge, of size 600mmx400mmwith mirror on front doorand with one towel rail for hanging towel of MS chromium plated fixed with screw and wooden gutties etc, complete all as specified and as dircted. |
| 61 | Looking mirror of size 600x450mm with bevelled edges, fancy type, made ofselected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers , complete all as specified. |
| 62 | S&F in repairs mild steel helical door spring 300mm size including roller and roller platefixed to wooden or welded to steel frames with welding/fitted with screws etc, complete all as specified and as directed. |
| 63 | S& F in repairs fancy type mild steel curtain rodspowder coated 25 mm dia with end fittings and fixing brackets of required size ( two nos end brackets and two Nos wall brackets fixed with wooden gutties and screws, complete all as specified and as directed. |
| 64 | S& F in repairs fancy type stainless steel curtain rods 25 mm dia with end fittings and fixing brackets of required size ( two nos end brackets and two Nos wall brackets fixed with wooden gutties and screws, complete all as specified and as directed. |
| 65 | S&F in repairs door closers of aluminium die cast bodyhydraulically regulated designation No 3, universal type, suitable for door shutters of 851 to1000 mm in width and of weight between 61 to 80 kgs and fixed, complete all as specified and as directed. |
| 66 | S&F Aluminum door seal in repairs with PVC bush of adjustable type (Overall width 25mm) of approved quality, fixed to door shutter, complete all as specified and as directed. |
| 67 | Vitreous china wash down water closet (pedestal pattern), suitable for P or S trap whitecomplete, including connection to drain pipe and to flushing pipe antisyphonage pipe etc, fixed in repair,complete all as specified and asdirected. |
| 68 | S&F in replacement plastic water closet seat cover, white colour, closet pattern with flat bottom and cover and including mild steel chromium plated or aluminum hinges device, complete all as specified and directed. |
| 69 | Vitreous china squating pan, orissa pattern size 580 x 440 mm white with integral foot rests and fixed in repairs with cement concrete bedding complete all as per specified. |
| 70 | PVC low level flushing cistern 10 ltrs capacity , valve less, syphonic action type,white, with inlet, ball valve, float and handle including brackets, PVC 32mm dia flushing pipe suitable for EWC or Orrisa WC etc.,fixed in repairs,complete all as specified and directed. |
| 71 | Vitreous china,white, wash hand basin, flat back of size 550x400mm, white including MS brackets and pedestal pattern including cutting for and pinning including 32mm dia CP brass waste coupling and PVC waste pipe ,fixed in repair complete all as specified. |
| 72 | S & F for waste pipe of dia 32mm for WHB/Sink, complete all as specified and as directed. |
| 73 | S&F in repairs 32mm bore diaof CP brass waste coupling suitable for WHB, complete all as specified and as directed. |
| 74 | S&F in repairs 40 mm bore diaof CP brass waste coupling suitable for Kitchen sink complete all as specified and as directed. |
| 75 | Supply and fixing PVC lid with locking arrangements suitable for PVC water tank of any capacity Ltr, complete all as specified and as directed. |
| 76 | Supply & fixing ball valves as in repairshigh pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of 15mm bore (minimum weight 142 gms )complete all as specified and as directed. |
| 77 | Supply & fixing ball valves as in repairs high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of 20 mm bore complete all as specified and as directed. |
| 78 | S & F in repairs for spindle suitable for 15mm bore CP taps/ mixers, complete all as specifed and as directed. |
| 79 | 20mm dia brass chromium plated tubular towel rails,D type,60 cm long between flanges Fixed in repair complete all as specified and as directed. |
| 80 | Glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated brackets, guard and railing 60cm long fixed in repair complete all as specified and as directed. |
| 81 | Corner Glass self ( With CP brakets), as in repairs complete all as specified and asdirected. |
| 82 | Single lever wall mixer, telephonic type, brass, chromium plated,fancy type, with capstan head handles with lettered \"hot\" and \"cold\", screwed down high pressure, including CP brass wall flanges and necessary extension nipples screwed for 15mm bore pipe connection,fixed in repair, complete all as specified and directed. |
| 83 | Centre hole mixer for mixing hot & cold water for wash hand basin, cast copper alloy, with dual capstan heads, chromium plated, screwed down high pressure, with lettered \"Hot\" & \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe suitable for 15mm bore, fixed in repair complete all as specified and directed. |
| 84 | Hand shower (telephonic shower), chromium plated, with 900mm long 15mm bore chrome finish flexible pipe, fixed in repair complete all as specified and directed. |
| 85 | Shower rose, brass, chromium plated, 100 x 100mm Square with or without swivel joint, with & including CP brass arm and wall flange, fixing to steel pipe or union as in repair complete all as specified and directed. |
| 86 | Angle valve, brass, chromium plated, fancy type,with capstan head handle screwed down high pressure, including CP brass wall flanges; screwed for 15mm bore pipe connection fixed in repairs complete all as specified and directed. |
| 87 | Bib taps, brass, chromium plated, fancy type,long nose, with capstan head handle screwed down high pressure, including CP brass wall flanges; screwed for 15mm bore pipe connection fixed in repairs complete all as specified and directed. |
| 88 | Health faucet, brass, chromium plated, with 900mm long 15mm bore chrome finish flexible pipe, fixed in repair complete all as specified and directed. |
| 89 | Jet spray, brass, chromium plated, heavy duty, including flexible pipe suitable for 15mm bore water connection; for EWC fixed in repair complete all as specified and as directed. |
| 90 | PVC flexible connections 450mm long 15mm dia with brass flange nuts & washers complete all as specified & directed. |
| 91 | PVC flexible connections 600mm long 15mm dia with brass flange nuts & washers complete all as specified & directed. |
| 92 | Soap dish, brass, chromium plated, heavy duty, fixed to wall with plugs with brass cadmium plated screws, fixed in repair complete all as specified and directed. |
| 93 | CP brass grating 100mm dia, centre hole, fixed in repair complete all as specified and asdirected. |
| 94 | Toilet paper holder, brass, chromium plated, heavy duty, fixed with brass screw complete all as specified and as directed. |
| 95 | Plate rack of size 750 x 750 x 300mm made of selected quality 0.63mm thick stainless sheet, of shape and design as approved by GE, fixed with brass screws and rawl plugs complete all as specified and directed. |
| 96 | Sink wall mixture, brass, chromium plated,fancy type, with capstan head handles screwed down high pressure, withlettered \"hot\" and \"cold\", including CP brass wall flanges and necessary extension nipples screwed for 15mm bore pipe connection,fixed in repair, complete all as specified and directed. |
| 97 | Sinks with drainage board made of stainless steel 1mm thick kitchen or laboratary with lugs, washers and wastes: including waste coupling and waste pipe & bedding in CM to dwarf wall or incl fixing cantiliver brackets and connecting upon to pipe overall size 915mm x 460mm bowl size 410mm 330mm x 160mm, fiexed in repair complete all as specified and as directed. |
| 98 | Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered\"Hot\" or \"Cold\" with\" long screwed shanks and fly-nuts, screwed for iron pipe and fixed in repairs, complete all as specified and as directed. |
| 99 | Dismantling water tanks of 1000 ltrs and removing to store, complete all as specified and as directed. |
| 100 | Dismantling water tanks of 500 ltrs and removing to store, complete all as specified and as directed. |
| 101 | Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity (Tripple layer) white in colour including water tank cover (internaly/interlocking arrangment for water tank cover), hoisted and fixed in position including tank nipple inlet & outlet and connecting up pipes complete all as specified and directed. |
| 102 | All as per description of Ser item No. 101.00 here in before but 500 ltr capacity water tank, complete all as specified and as dircted. |
| 103 | Taking up ordown steel tubing and connection, including cleaning for re-fixing or removal to store ofsize of pipe 15 mm bore laid on floor or wall complete all as specified and directed. |
| 104 | Taking up ordown steel tubing and connection, including cleaning for refixing or removal to store ofsize of pipe 20 mm bore laid on floor or wall complete all as specified and directed. |
| 105 | 15 mm dia medium grade GI tubes with all fittings and fixedto walls and ceiling or laid in floors complete all as specified and directed. |
| 106 | All as per item No. 105.00 here in before but 20mm bore complete all as specified and directed. |
| 107 | S&F 16 mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 including all necessary fittings in wall/ trenches complete all as specified |
| 108 | All as per item No107.00 here in before but 20mm bore complete all as specified and directed. |
| 109 | Dismantling of wrought iron or mild steel dia work of any description complete all as per specified and directed by Engr-in-Charge. |
| 110 | Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410-W(Gde-E- 250)quality A complete all as per specified and directed by Engr-in-Charge |
| 111 | Dismantling asbestos cement (Corrugated or semi corrugated etc) sheet in roof covering including ridges, all as per specified and directed. |
| 112 | S&F in repair Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-charge. |
| 113 | S&F in repair Pre-painted glavalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-charge. |
| 114 | Preparation of old decorated plastered surfaces and applying one coat of white wash on walls, complete all as specified and directed. |
| 115 | Preparation of old decorated plastered surfaces and applying one coat of white wash on ceiling, complete all as specified and directed. |
| 116 | Complete removing existing treatment on walls surfaces by scraping down smoke soot, moulds moss & efflorences salts and trading oil & greasy spots and applying two coats of distemper oil emulsionwhite or tinted over one coat of 1 to 1.20mm thick wall care putty over a coat of alkali resistance primer, complete all as specified and directed. |
| 117 | Preparation of new plastered surfaces by using necessary filling compound of white putty to obtain smooth/even finish using sand paper and applying two coats of distemper oil emulsion over a coat of alkali resistant cement based priming paint complete all as specified and directed. |
| 118 | Preparation of old plastered or un-plastered surface by brooming down or steel wire brushing, scraping down smoke soot, moulds moss and filling nails marks with wall puttyand applying one coat of OBD white ortinted, complete all as specified and directed. |
| 119 | Preparation of plastered or un-plastered surface old decorative and washing down, brooming down or steel wire brushing, etc and applying one coat of cement base paint on walls, complete, all as specified and directed. |
| 120 | Prepration of new plaster surfaces ofwallandapplying two coats of cement based paint over a coat of alkali resistant cement base primer on wall surfaces complete all as specified and directed. |
| 121 | Complete removing existing treatment upto 4 storey bldg including scraping,removing all mud,cake with wire brush and gunny bags from old plastered surfaces and preparation of surfaces by using necessary filling compound ofwhite putty exterior grade to obtain smooth/even finish using sand paper and applying two coats of first quality exterior grade wheather proofing acrylic emulsion paint as per manufacturers instructions of any shade and colour over a coat of alkali resistant cement based priming paint complete all as specified and directed. |
| 122 | Preparation of old wooden painted surface not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint white or tinted, complete all as specified and directed. |
| 123 | M&L for preparation of new woodensurfaces of any description, not otherwise described over 10 cms width or girth and applying two coats of synthetic enamel paintoveronecoat of pinkprimer, complete all as specified and as dircted. |
| 124 | Preparation of old painted steel and iron surfaces exc 10 cm width or girthandapplying one coat of synthetic enamel paint , complete all as specified and directed. |
| 125 | Dismantling Wall and ceiling boards (fibre pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specifiedand directed. |
| 126 | S & F powder coated GI frame grid of size 600 x 600 for false ceiling including non asbestos fibre cement building boards of 4mm thick and size 595x595mm , fixed or laid/ inserted to timber/GI/Aluminium frame work with screws and including butterfly clip complete all as spd and directed. |
| 127 | S & F hollow PVC Wall panelling consisting of 5-6mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at siteas per specifications and drawing complete all as specified and as directed. |
| 128 | Taking down carefully existing surface/ concealed unserviceable aluminum/ copper point wiring(light, fan, socket, power or sunken box) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets, bracket holder, boards light fittings,etc.and making good to disturbed surfaces of walls, floors, ceilings, etc. where required and finished the existing surfaces after complete of new point wiring as specified here-in-after complete all as specified and as directed by Engr-in-Charge. |
| 129 | Taking down unserviceable sub main wiring of any type and any size including wooden batten, PVC conduit or casing caping complete all as specified and as directed by Engr-in-Charge. |
| 130 | Taking down unserviceable main switch/ DBs of any size/ capacity including MCB any type & capacity for reuse carefully disconnecting and making good to disturbed surfaces complete all as specified and directed by Engr-in-Charge. |
| 131 | M&L for Point wiring using approved color coding as per IS code (Red,Black and Green for single phase circuit) with multi stranded copper condutor 1.5 Sqmm nominal cross section area,single core,PVC insulated and unsheathed FRLSH cable 1100V grade,in and including medium grade,PVC concealed conduit ISI marked of dia not less than 20mm and conduit accessories concealed in wall/roof/floor etc with terminated to new pressed flush metal box and readily available cover with outer plates and inner plates etc, suitable for mounting modular type switches , sockets, fan regulators etc PVC insulatedPVC insulated multistranded copper condutor 1.5 sqmm nominal cross section area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the followings :- One light Pointcontrolled by one,one wayswitch. |
| 132 | All as per item No 131.00 here in before for one ceiling fan controlled by one way switch. |
| 133 | All as per item No 131.00 here in before for one exhaust fan controlled by one way switch. |
| 134 | All as per item No 131.00 here in before for one bell point controlled by one way switch. |
| 135 | All as per item No 131.00 here in before for 3 Pin 5 Amp Socket on the same board, complete all as specified. |
| 136 | All as per item No 131.00 above but 3 Pin 5 Amp Socket on independent board complete all as specified and directed. |
| 137 | All as per item No 131.00 here in before but for point wiring with two runs of FRLSH PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 2.5 sqmm drawn through in and includingPVC conduit size of not less than 25mm concecled in wall / surface |
| 138 | All as per item No 131.00 here in before but for Geyser/AC point with 4 Sqmm on independent board incl. 4 sqmm multi stranded copper conductor earth wire connected to common earth/earth dolly complete. |
| 139 | M&L for modular switchsingle pole one way 6 amps 240 volts with polycarbonate body complete all as specified and directed. |
| 140 | M&L for modular socket 6 amps 5 pin flush type, 240 volts. with polycarbonate body. complete all as specified and directed. |
| 141 | M&L for modular socket out let,5 pin 6ampsand 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed. |
| 142 | M&L for modular switch single pole one way 16 amps 240 volts with polycarbonate body complete all as specified and directed. |
| 143 | Supply and fixing modular electronic fan regulator, step type, two module 120 watt 230 volt and making all necessary connections complete all as specified and directed. |
| 144 | S & F modular bell push type 6 Amp 1 module |
| 145 | M & L for call bell Ding dong type complete all as directed. |
| 146 | S&F ceiling rose surface bakelite type 65x50mm three terminals. |
| 147 | M&L for Point wiring using approved color coding as per IS code (Red,Black and Green for single phase circuit) with multi stranded copper condutor 1.5 Sqmm nominal cross section area,single core,PVC insulated and unsheathed FRLSH cable 1100V grade,in and including medium grade,PVC concealed conduit ISI marked of dia not less than 20mm and conduilt accessories concealed in wall/roof/floor etc withincluding Tee, Junction boxes and provision of3 mm thick plastic laminated sheet cover of suitable size on existing terminal boxes with new brass screwsfor mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with strandedcopper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly for one light/Fan/exhaust fan point controlled by one Switch complete all as specified & directed for the follongs :-one light Pointcontrolled by one,one wayswitch. |
| 148 | All as per item No 147.00 here in before for one ceiling fan controlled by one way switch. |
| 149 | All as per item No 147.00 here in before for one bell point controlled by one way switch. |
| 150 | All as per item No 147.00 here in before for 3 Pin 5 Amp Socket on independent board complete all as specified and directed. |
| 151 | All as per item No 147.00 here in before but M & L for point wiring with two runs of FRLSH PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 2.5 sqmm drawn through in and includingPVC conduit size of not less than 25mm concecled in wall / surfacecomplete all as specified and directed. |
| 152 | Switch piano, flush type, ivory finish 5/6 Ampere single pole, one way with marking as light complete, all as specified and directed by Engr-in-Charge. |
| 153 | Socket out let 2 in 1, 3 Pin suitable for 5/6 Ampere in same board flush type complete all as specified and as directed by Engr-in-Charge. |
| 154 | Switch piano, flush type, ivory finish 15/16 Ampere single pole, one way with marking as light complete, all as specified and directed by Engr-in-Charge. |
| 155 | Supply and fixing of socket out let multipurpose 2 in 1, 3 Pin suitable for 5/6 Amp and 3 Pin suitable 15/16 Ampere flush type complete all as specified and as directed by Engr-in-Charge. |
| 156 | Switch socket out letcombination 2 in 1, 3 Pin suitable for 5/6 Ampere for independant board flush type complete all as specified and as directed by Engr-in-Charge. |
| 157 | Switch socketcombinationflush type multi purpose 3 pin 16 Amps and one 3 pin 6 Amps controlled by one switch withfuse & neon indicator ISI mark |
| 158 | Bell push, ivory finish 5/6 Ampere single pole, one way complete, all as specified and directed by Engr-in-Charge. |
| 159 | Supply and fixing of one 5/6 Amp two way switch complete all as specified and directed by Engr-in-Charge |
| 160 | Supply and fixing of stepped type 5 steps 100 watts electronic fan regulator flush type on the existing phenolic laminated sheets etc as required all as specified and as directed by Engr-in-Charge. |
| 161 | Lamp holder pendant/angle type, PVC/polycarbonate type, insulated body with back plate of batten fitting complete all as specified and as directed. |
| 162 | Supply and fixing of modular White cover plate with frame, 1 modulecomplete all as specified and as directed by Engr-in-Charge. |
| 163 | Supply and fix modular white cover plate with framebut 2 modulecomplete all as specified and as directed by Engr-in-Charge. |
| 164 | Supply and fix modular white cover plate with framebut 3 modulecomplete all as specified and as directed by Engr-in-Charge. |
| 165 | Supply and fix modular white cover plate with framebut 4/5/6 module as per site requirementcomplete all as specified and as directed. |
| 166 | Supply and fix modular white cover plate with framebut 8 modulecomplete all as specified and as directed. |
| 167 | Supply and fix modular white cover plate with framebut 12 modulecomplete all as specified and as directed. |
| 168 | Supply and fixing in replacement modular metal flush box with 1.6 mm thick1/2 module flishing mounting in the wall for fitting cover plate with frame on switch/socket complete all as specified . |
| 169 | All as per item No 168.00 here in before but size 3 module complete all as specified. |
| 170 | All as per item No 168.00 here in before but size 6 module complete all as specified. |
| 171 | All as per item No 168.00 here in before but size 8 module complete all as specified. |
| 172 | All as per item No 168.00 here in before but size 12 module complete all as specified. |
| 173 | S&F in repair Surface Mounting modular type Plastic Boxes / PVC rectangular block including cover plates for mounting of switches, sockets, fan regulator etc. of size 2 module including making necessary cutting and making good existing surface all as specified and as directed. |
| 174 | All as per item No 173.00 here in before but size 3 Module. |
| 175 | All as per item No 173.00 here in before but size 4 Module. |
| 176 | All as per item No 173.00 here in before but size 6 Module. |
| 177 | S&F in repair Switch socket combination box type gang box 5 pin 5 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge. |
| 178 | S&F in repair Switch socket combination box type gang box type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge. |
| 179 | Sub main wiring with two run single core 1.5 sqmm FRLSH copper conductor cable PVC insulated,unsheathed, 1100V grade including 25mm dia in PVC concealed conduit/PVC casing & caping medium grade ISI marked with all accessories such as Tees, elbows, junctgion boxes etc, as required fixed on wall alongwith one run of 1.5 sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable submain of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-incharge.Note : Two runs of 1.5 sqmm and one run 1.5 sqmm cable and one run of PVC conduit shall be measured as one RM |
| 180 | All as per item No 179.00 here in before but using two run single core 2.5 sqmm FRLSH copper conductor cable PVC insulated, 1100V grade alongwith one run of 2.5 sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board completeNote : Two runs of 2.5 sqmm and one run 2.5 sqmm cable and one run of PVC conduit shall be measured as one RM |
| 181 | All as per item No 179.00 here in before but using two run single core 4.00 sqmm FRLSH copper conductor cable PVC insulated, 1100V grade alongwith one run of 4.00 sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board completeNote : Two runs of 4.00 sqmm and one run 4.00 sqmm cable and one run of PVC conduit shall be measured as one RM |
| 182 | S&F in replacement single pole and neutral sheet metal steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz double door SPN DB system 4 Way all as specified and directed by engineer in charge. |
| 183 | All as per item No 182.00 here in before but size double door SPN DB system 6 Way all as specified and directed by engineer in charge. |
| 184 | All as per item No 182.00 here in before but size double door SPN DB system 8 Way all as specified and directed by engineer in charge. |
| 185 | All as per item No 182.00 here in before but size double door SPN DB system 12 Way all as specified and directed by engineer in charge. |
| 186 | All as per item No 182.00 here in before but size double door MCB DB TPN 4 ways 415 volts grade IP 43 Protection all as specified and directed by engineer in charge. |
| 187 | All as per item No 182.00 here in before but size VTPN MCCB Double door Distribution Board 04 way 415 volts grade IP 43 Protection Grade with provision for (MCCB) as incoming and Three/single phase all as specified and directed by engineer in charge. |
| 188 | S&F in repair connection and testing \"C\" series TPN MCB 40 to 63 Amp 440V, 50Hz, 10kA for lighting and other domestic loads include necessary copper lugs etc all as specified and as directed by Engineer- inCharge. |
| 189 | All as per item No 188.00 here in before but SPN MCB 40 to 63 Amp 240V, 50Hz, 10kA |
| 190 | All as per item No 188.00 here in beforebut SPN MCB 32 Amp 240V, 50Hz, 10kA |
| 191 | All as per item No 188.00 here in beforebut SP MCB 6 - 32 Amp 240V, 50Hz, 10kA |
| 192 | All as per item No 188.00 here in beforebut SP MCB 40 Amp 240V, 50Hz, 10kA |
| 193 | All as per item No 188.00 here in beforebut SP MCB 63 Amp 240V, 50Hz, 10kA |
| 194 | S&F in repair LED light fitting with high output diffuser 1 feet, 5 watt 220 V Trimline Neu is a robust and high performance batten. This LED luminaire comprises of extruded channel in thermally conductive material. High translucent serrated milky white/warm white diffuseris used to get glare free and smooth light distribution. Efficacy: 100 lm/W. Also available in warm white and natural whiteconnecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by engineer in charge. CRI > 80, IP - 20, CCT - 6500K complete all as specified and as directed. |
| 195 | All as per item No 194.00 here in beforebut2 feet, 10 watt 220 V size complete all as specified and as directed by engineer in charge. |
| 196 | All as per item No 194.00 here in before but 4 feet, 20 watt 220 V size complete all as specified and as directed by engineer in charge. |
| 197 | S&F in repair LED Bulk head (6500K) fitting of 09/10 Watt surface mounting type extruded Polycorbonate body with diffuser complete with testing all as specified and directed by engineer in charge |
| 198 | S&F in replacement of ceiling mounting LED warm light fitting POLARIS PAN NIO-III,PANEL 2\"x2\" PLR 36 FO-ww ,35/36 watt LED environmental friendly , new generation , aesthetically designed ,ultra modern recess mounting luminaire with high brightness SMD LEDs as light source suitable for Armstrong /grid /ceiling all as specified and directed by Engr-in-charge. |
| 199 | S&F in replacement of surface/recessed mounting LEDdown lighter round/square shape 10/12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-charge. |
| 200 | All as per item No 199.00 here in before but for LED down lighter round/square shape 15 watt. |
| 201 | All as per item No 199.00 here in before but for LED down lighter round/square shape 20/22 watt. |
| 202 | S&F in repair surface mounting LEDsquare shape 18 watt ( size 1\" x 1\")220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-charge. |
| 203 | Supply and fixing in repairs LED street light fitting 35 Watt 230 V ACIP66 protection efficacy ≥ 110 lm/W outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with 0.6 mtr long 20/25 mm (as per manufacturer standard)dia GI Pipe in 45 degree bend shape and necessary clamping devices required at site complete all as specifiedand directed by Engr-in-Charge. |
| 204 | S&F in repair Metal clad Plug socket single pole enclosure with two pin earth plug and socket with one single 20 Amp , 240 volts MCB complete all as specified and directed by Engineer-in-Charge. |
| 205 | Supplyand fixing of fan capacitor in repairs 2.5/3.15 MFD complete all as specified and as directed . |
| 206 | Supply and fixing of Polycarbonate plug top in repairs, 3-pin, 15/16 Amps ISI Marked |
| 207 | Supply and fixing of Polycarbonate plug top in repairs, 3-pin, 5 Amps ISI Marked |
| 208 | Supply only of Rigid non-metallic PVC casing caping exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipehooks etc complete all as specified and as directed. |
| 209 | S&F in repair rigid non - metalic PVC casing caping of 25/12mm inclusive of all elbow, tees,etc complete all as per the direction of Engr-in-Charge. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail