| 1 | Provision of lighting arrangement |
| 2 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 3 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. butwithout charcoal/ coke and salt as required. |
| 4 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 5 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 6 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm |
| 7 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm |
| 8 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm |
| 9 | Supplying and erection of galvanised ‘D’ iron clamps complete with shackle insulator (100 mm X 110 mm), G.I. bolts, nuts and washers, coach screws etc. as required. |
| 10 | Dismantling of pole/ street light standard/ strut embedded incement concrete foundation etc. as required. |
| 11 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 12 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 13 | Fabrication, supply & erection of 7.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm, base plate of size 225 x 225 x 12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor - 4 nos. & shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB \"C\" characteristics ,earth Stud. cable support, clamp suitable for upto 4x25sqmm cable ..Logo/Name of manufacturer shall be either embosed or rivited plateon the pole, galvanization as per relevant IS code etc as required |
| 14 | Fabrication supplyiing and fixing class B Galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap & 1000 mm long 40 mm dia galvanized pipe with tightening bolts complete as reqd |
| 15 | Fabrication supplyiing and fixing class B Galvanised double overhang arm bracket made out of 250 mm long galvanized top tube with cap & 1000 mm long 40 mm dia galvanized pipe with tightening bolts complete as reqd |
| 16 | Providing and laying in position M25 grade reinforced cement concrete foundation of size 600 mm (L) ×600 mm wide and 1200 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 1160 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia- 1600 mm (approx) -8 nos.(with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 20mm dia, 750 mm long, J type i/c 2 nos. template anchor plates of size 225mm×225mm×3mm and providing DCW HDPE for cable entry and exit as required for 7m and 8 mtr pole. |
| 17 | Providing and laying of HDPE PIPE OF 40mm outer dia with PN 4 rating by hand Moling/Mannual method Confirming to IS 4984 592 |
| 18 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm |
| 19 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm |
| 20 | Fabrication,Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick (Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circufrential weld. It should also included accessories for High Mast head frame ,2 point suspension system with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. flood light luminaries luminaries symmitrically and its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L)X1m (W)X2m deep i/c excavation of earth i/c excavation of earth, providing cutting, bending and placing in position, rewinforcement of cold twisted bars of 12 mm dia -2100 mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required withpositioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required forhigh mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c,4Nos S.PMCB,63Amp.DP Isolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. galvanized as per relevant IS. |
| 21 | Supply and fabrication of pole protection system made up of 8 SWG steel wire mesh of size 25mm x 75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc as reqd. |
| 22 | Supply and fixing of 32mm dia X 1 meter long G.I. Pipe (Medium Class) bracket for mounting of fluorescent/HPMV/HPSV Street Light fitting on pole including bending the pipe to the required shape , 2 nos 25mm X 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd. |
| 23 | Supply of 70 watt LED Street Light Luminaire fitted with lens made of pressure die cast aluminum housing and toughened glass cover complete with the following specifications as per relevant IS (a) Total System Wattage :70 Watt + 5% (b) Luminaire Efficacy -130 Lumens/watt ( minimum) (c) Powerfactor > 0.95 (d) Protection Class IP66 (e) LED Package shall be Ceramic Base, (f) Multi chip,array,multi die,Mid power,Integrated array and COB type LED Chip is not acceptable (g) Operating Current of LED < 70% of rated maximum forward current, limited to a minimum of 350 mA and maximum of 1000 mA. (h) Wattage of LED Package : One watt to Five watt maximum (i) CRI >70 (j) THD<10% for complete fixture (k) Operating Voltage – 110-320 V, 50Hz +/- 3%. (l) The driver must have thermal Protection against 75 deg C ambient temperature with internal SPD of minimum 6 KV. Separate Compartment for Driver (m) Life of Street Light: Minimum 50,000 hrs |
| 24 | Supply of 140 watt LED Street light/ Flood Light Luminaire fitted with lens made of pressure die cast aluminum housing and toughened glass cover complete with the following specifications as per relevant IS (a) Total System Wattage :140 Watt + 5% (b) Luminaire Efficacy -130 Lumens/watt ( minimum) (c) Powerfactor > 0.95 (d) Protection Class IP66 (e) LED Package shall be Ceramic Base, (f) Multi chip,array,multi die,Mid power,Integrated array and COB type LED Chip is not acceptable (g) Operating Current of LED < 70% of rated maximum forward current, limited to a minimum of 350 mA and maximum of 1000 mA. (h) Wattage of LED Package : One watt to Five watt maximum (i) CRI >70 (j) THD<10% for complete fixture (k) Operating Voltage – 110-320 V, 50Hz +/- 3%. (l) The driver must have thermal Protection against 75 deg C ambient temperature with internal SPD of minimum 6 KV. Separate Compartment for Driver(m) Life of Street Light: Minimum 50,000 hrs |
| 25 | Installation and Commissioning of Street Light/flood light etc as required |