| 1 | Scraping & Removing of white wash/ distemper/algli etc. from plain plaster & surfaces gently with care to keep intact the old designs. |
| 2 | Providing and fixing fully panelled/partly panelled/ double leaf shutter frame for doors as per approved design and drawings with approved ordinary C.P./ oxidised steel fittings as per Annexure - \"A\" and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete : 35mm thick. Ivory coast wood grade I |
| 3 | 5 step fan regulator 2 Module 360 degree rotating |
| 4 | Installation , testing and Commissioning of ceiling fan (any size) including wiring the down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in-charge. With regulator |
| 5 | Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in-charge. 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |
| 6 | Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab including cutting chase and making good and painting exposed portion of the clamps complete. |
| 7 | Surface Mounting (with extruded alumn. Housing ) Minimum lumen output 1300 lm |
| 8 | Providing and fixing single paitam (rebated) stone doors windows and ventilator frames of approved quarry in cement sand mortar 1:4: Size 100x 75mm |
| 9 | Providing and fixing double paitam (rebated) stone doors windows and ventilator frames of approved quality in cement sand mortar 1:4: Size 125 x 100mm |
| 10 | Renewing glass panes with wooden fillets wherever necessary.Float glass panes of thickness 5.5 mm |
| 11 | Repair of door, window shutters including cost of material and labour for change of damaged :13.33(c) Aldrop of mild Steel |
| 12 | (d) Stopper of Aluminium with |
| 13 | (f) Steel Hinges |
| 14 | (g) Mild Steel Tower Bolt 6\" long |
| 15 | Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 16 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 17 | Providing and fixing 1st quality MAT finished ceramic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). |
| 18 | Extra for Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477 , using 5kg. adhesive per cum of tile area, in average 3mm thickness instead of cement mortar. |
| 19 | Providing and fixing on wall face Unplasticised Rigid PVC Single socketed pipes rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.110 mm diameter |
| 20 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.Single tee with door (110x110x110 mm) |
| 21 | Bend 87.5° (110 mm bend) |
| 22 | Shoe (Plain) 110 mm Shoe |
| 23 | Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work.100 mm diameter pipes |
| 24 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in-charge. Concealed work including cutting chases and making good the walls etc.,15 mm nominal outer dia .Pipes. |
| 25 | 25 mm nominal outer dia .Pipes. |
| 26 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore |
| 27 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore |
| 28 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead:With cement mortar 1:4 (1 cement : 4 fine sand) |
| 29 | Providing and applying white cement based putty overplastered surface to prepare the surface even and smoothcomplete:New Plastered Surface (three or more coats) |
| 30 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding.Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 31 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work.12.46.1 |
| 33 | Spray painting in approved shade and approved quality with Duco paint of required colour to give even shade with two or more coats by compressor including sand papering, NC putty filler coat etc complete in all respect as per design given by Engineeer incharge on new work. |
| 34 | Accessories approved make & modular type, approved make (Roma) complete all respect - i) surface mounted complete; ii) type 3 pin 13A multi sockets, with suitable size box and plate with wiring connectious complete. Finishing: fan switch A regulator, with suitable size box and plate |
| 35 | Supply, erection, testing and commissioning of switches and accessories approved make (Roma) & modular type, approved make (Roma) complete in all respect. i) Surface mounted 6A/10A with suitable size box and plate with wiring connections complete. Finishing- as per approved |
| 36 | Providing and installing ceiling hanging handi fixtures with diameter 12 inches all complete. |
| 37 | Providing and layingDr. fixit WONDER Proof-UV Resistance hybrid urethane waterproofing Membrane For Roof terrace.Clean the surface by using air blower and ensure the surface is free from laitance, loose or friable materials, debris etc. Apply Primer coat of High Solid Content, Cold Liquid- Applied Elastomeric Water Proofing Membrane Dr Fixit Wonderproof using Brush/ roller and air cured the surface for 2-3 hours, laying 45 gsm Fiber mesh on the entire surface. apply two coats of High Solid Content, Cold Liquid- Applied Elastomeric Water Proofing Membrane Dr Fixit Wonderproof, each coats is perpendicular to the coat between the interval of 3-4 hours. |