| 1 | Dismantling of ACSR conductors from the disturbed span including jumper, removing the binding from insulator, of any size for LT OH Line/ structures, etccomplete all specefied and as directed |
| 2 | Dismantling/taking down old unserviceable cross arms, bracings, support, clamp including nuts, bolts and washers complete all as specified and as directed. |
| 3 | Dismantling insulators any type, any size complete all as specified and as directed. |
| 4 | Dismantling of stay assembly complete including bolts, nuts & washers etc. of any description any size and removing from the site complete all as specified and as directed. |
| 5 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for taking out/for laying under ground cables/pipes etc and getting out any type soil complete all as specified andas directed. |
| 6 | Returning filling in including spreading, levelling, watering and well ramming in layers n-exc 25 cm complete all as specified and as directed. |
| 7 | Removing excavated soil to a distance n-exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point |
| 8 | M&L for sand cushioning in cable trenches over & under the cables, with river washed coarse sand, as per standard practice with proper compaction complete all as specified anddirected by Engr-in-Charge. Note :- (Punned thickness shall be considered for payment). |
| 9 | M&L for brick protection over cables inside the trench by using common burnt clay building bricks,sub-class\"B\" laid dry and flat and width wise along the axis of the trench complete all as specified and as directed by Engineer-in-Charge. |
| 10 | Boring of holes under road, pavement, hard standing by trenchless technologytechnique for 40-80 mm dia pipe all as specified and as directed by Engineer-in-Charge. |
| 11 | M&L for GI pipe light grade ofsizes 80mm dia, ISI marked with all fitting for cable protection, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc all as specified and as directed by Engineer-in-Charge. |
| 12 | All as per item No. 11 above but size 50mm dia complete all as ditected. |
| 13 | All as per item No. 11 above but size 40mm dia complete all as directed. |
| 14 | M&L for PVC Flexible suction hose pipe (light grade), laid in trenches, under coping, bendor fixing on wall/pole/ crossing nallah etc of 40mm dia, all as specified and as directed by Engineer-in-Charge. |
| 15 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power UG cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core confirming to relevant IS specifcations, complete all as specified and as directed. |
| 16 | All as per item No. 15 above but 95 sq mm 3.5 core complete all as dirceted. |
| 17 | All as per item No. 15 above but 70sq mm 3.5 core complete all as dirceted. |
| 18 | All as per item No. 15 above but 50 sq mm 3.5 core complete all as dirceted. |
| 19 | All as per item No. 15 above but 25 sq mm 4.0 core complete all as dirceted. |
| 20 | All as per item No. 15 above but 16 sq mm 4.0 core complete all as dirceted. |
| 21 | All as per item No. 15 above but 16 sq mm 2.0 core complete all as dirceted. |
| 22 | All as per item No. 15 above but 10 sq mm 2.0 core complete all as dirceted. |
| 23 | All as per item No. 15 above but 6 sq mm 2.0 core complete all as dirceted. |
| 24 | M&L forstraight through joints (heat shrinkable type) cable joint kit including jointing materials for making joints of UG electric cable 1100 volt grade heavy duty with PVC/XLPE insulated aluminium conductor nominal cross sectional area 25 to 50 sqmm 3.5/4.0 core and testing complete all as specefied and as directed. |
| 25 | M&L for straight through joints (heat shrinkable type) cable joint kit including jointing materials for making joints of UG electric cable 1100 volt grade heavy duty with PVC/XLPE insulated aluminium conductor nominal cross sectional area 95 to 120 sqmm 3.5 core and testing complete all as specefied and as directed. |
| 26 | M&L for plain cement concrete type C1(1:3:6) using 20 mm graded stone aggregate as in coping including necessary form work and finishing exposed surface/white washing all as directed. |
| 27 | Supply and fixing thermo plastic cable terminal box of size not less then 167x125x82mm including terminals with locking arrangments including necessary mounting arrangement of any steel tubular/RCC poles with suitable size of clamps nuts bolts washer etc. fixed with poles including one single pole MCB of capacity 6-32A and PVC connector for cable termination complete all as specified and directed. |
| 28 | Supply & fixing wheather proof copper three core cable of size 1.5 Sqmm drawn in and including UPVC conduit medium grade fixed to pole/wall with suitable size clamps or fixing accessories complete all as specified and directed. |
| 29 | Supply & fixing street light bracket decorative type single arm fixing on the pole,made of GI pipe light grade pipe size not less than 1.0 Mtr, 32 mm dia as per sample and fixed with suitable size of MS clamps, nut, bolt, washers, welding work as required etc to poles/walls complete all as directed. |
| 30 | S&F LED Street light fitting 1 x 60/70 Watt pressure die cast housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution connecting up complete with suitable size PVC insulated wire ISI marked, including taking out the existing fully rusted unserviceable complete all as specified and as directed. |
| 31 | M&L street light panel board factory made outdoor type suitable for connecting 6 KW, 3 phase load prefixed with and including the following accessories complete. (a) MCB, 3 Pole, 40 Amp, 50Hz , 415V -01 Nos(b) Digital timer switch (24 hrs operation) - 01 Nos (c) Contactor 32 Amps capacity three phase, 415 Volts 50 Hz |
| 32 | M & L for fabrication of LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made out of 3.15 mm thick CRCA sheet of size not less then 1200mm x 1000mm x 450mm and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting locking arrangement and painted to both internal and external surfaces with powder coating paint in heatprocess in grey colour complete all as specified and as directed and comprising the followings:-BUSBAR :- Aluminium bus bar for 4Pole of minimum capacity 600 Amps- 01 (set of 04)INCOMING :- (a) MCCB, 4P, 400 Amps, 35 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 No(b) Digital voltmeter 3 Phase( 0-500 volt) 96mm x 96mm having accuracy class 1.0, 4.5 digit LED display - 01 No (c) Digital Ammeter three Phase having accuracy class 1.0, 4.5 digit 0.5 VAburden with LED display, size 96mm x 96mm with 3 Nos CT (200/5)- 01 No(d) LED R-Y-B indicating lamps (Set of Three)- 01 set(e) Instrumental control wiring MCB/fuse min 3 Amps - 03 NosOUTGOING:-(a) MCCB, 4P, 250 Amps, 35 kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos(b) MCCB, 4P, 100 Amps, 25 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 Nos(c) MCB 63 Amp TPN10 KA \"C\" series, 415 volts, AC, 50 Hz- 01 Nos(d) MCB 40 Amp SPN10 KA \"C\" series, 230 volts, AC, 50 Hz- 02 NosNOTE:-(i) Wiring of panel board shall be done using multistranded copper wire of suitable size and gauge with connector, copper lugs all as required at site.(ii) The rate quoted by tenderer also includes to fix the legs of the panel box in PCC 1:3:6 pot hole foundation 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. |
| 33 | M & L for fabrication of LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made out of 3.15 mm thick CRCA sheet of size not less then 1000mm x 1000mm x 450mm and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting locking arrangement and painted to both internal and external surfaces with powder coating paint in heatprocess in grey colour complete all as specified and as directed and comprising the followings:-BUSBAR :- Aluminium bus bar for 4 Pole of minimum capacity 400 Amps- 01 (set of 04), Digital multifunction meter (Volt, Amp) - 01 NoINCOMING :- (a) MCCB, 4P, 250 Amps, 35 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 No(b) On load changeover switch, capacity 200 A, 415 volts, AC, 50 Hz- 01 Nos(c) LED R-Y-B indicating lamps (Set of Three)- 01 set(d) Digital voltmeter 3 Phase( 0-500 volt) 96mm x 96mm having accuracy class 1.0, 4.5 digit LED display - 01 No (e) Digital Ammeter three Phase having accuracy class 1.0, 4.5 digit 0.5 VAburden with LED display, size 96mm x 96mm with 3 Nos CT (200/5)- 01 NoOUTGOING:-(a) MCCB, 4P, 200 Amps, 35 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 Nos(b) MCCB, 4P, 100 Amps, 25 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 Nos(c) MCB 40 Amp SPN10 KA \"C\" series, 230 volts, AC, 50 Hz- 04 NosNOTE:-(i) Wiring of panel board with copper wire of suitable size and gauge with connector, copper lugs all as required at site.(ii) The rate quoted by tenderer also includes to fix the legs of the panel box in PCC 1:3:6 pot hole foundation 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. |
| 34 | M & L for fabrication of LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made out of 3.15 mm thick CRCA sheet of size not less then 1000mm x 800mm x 450mm and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting locking arrangement and painted to both internal and external surfaces with powder coating paint in heatprocess in grey colour complete all as specified and as directed and comprising the followings:-BUSBAR :- Aluminium bus bar for 4 Pole of minimum capacity 350 Amps- 01 (set of 04), Digital multifunction meter (Volt, Amp) - 01 NoINCOMING:- (a) MCCB, 4P, 200 Amps, 35 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 Nos(b) LED R-Y-B indicating lamps (Set of Three)- 01 set(c) Digital voltmeter 3 Phase( 0-500 volt) 96mm x 96mm having accuracy class 1.0, 4.5 digit LED display - 01 No (d) Digital Ammeter three Phase having accuracy class 1.0, 4.5 digit 0.5 VAburden with LED display, size 96mm x 96mm with 3 Nos CT (200/5)- 01 NoOUTGOING:-(a) MCCB, 4P, 100 Amps, 25 kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos(b) MCB 63 Amp TPN10 KA \"C\" series, 415 volts, AC, 50 Hz- 01 Nos(c) MCB 40 Amp SPN10 KA \"C\" series, 230 volts, AC, 50 Hz- 04 NosNOTE:-(i) Wiring of panel board shall be with using multistranded copper wire of suitable size and gauge with connector, copper lugs all as required at site.(ii) The rate quoted by tenderer also includes to fix the legs of the panel box in PCC 1:3:6 pot hole foundation 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. |
| 35 | M & L for fabrication of LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made out of 3.15 mm thick CRCA sheet of size not less then 1000mm x 800mm x 450mm and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting locking arrangement and painted to both internal and external surfaces with powder coating paint in heatprocess in grey colour complete all as specified and as directed and comprising the followings:-BUSBAR :- Aluminium bus bar for 4 Pole of minimum capacity 400 Amps- 01 (set of 04), Digital multifunction meter (Volt, Amp) - 01 NoINCOMING :- (a) MCCB, 4P, 250 Amps, 35 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 No(b) LED R-Y-B indicating lamps (Set of Three)- 01 set(c) Digital voltmeter 3 Phase( 0-500 volt) 96mm x 96mm having accuracy class 1.0, 4.5 digit LED display - 01 No (d) Digital Ammeter three Phase having accuracy class 1.0, 4.5 digit 0.5 VAburden with LED display, size 96mm x 96mm with 3 Nos CT (200/5)- 01 NoOUTGOING:-(a) MCCB, 4P, 160 Amps, 25 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 Nos(b) MCCB, 3P, 63 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 03 Nos(c) MCB 40 Amp SPN10 KA \"C\" series, 230 volts, AC, 50 Hz- 10 NosNOTE:-(i) Wiring of panel board shall be with using multistranded copper wire of suitable size and gauge with connector, copper lugs all as required at site.(ii) The rate quoted by tenderer also includes to fix the legs of the panel box in PCC 1:3:6 pot hole foundation 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. |
| 36 | M & L for fabrication of LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made out of 3.15 mm thick CRCA sheet of size not less then 900mm x 800mm x 450mm and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting locking arrangement and painted to both internal and external surfaces with powder coating paint in heatprocess in grey colour complete all as specified and as directed and comprising the followings:-BUSBAR :- Aluminium bus bar for 4Pole of minimum capacity 250 Amps- 01 (set of 04), Digital multifunction meter (Volt, Amp) - 01 NoINCOMING :- (a) MCCB, 4P, 160 Amps, 25 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 Nos(b) LED R-Y-B indicating lamps (Set of Three)- 01 set(c) Digital voltmeter 3 Phase( 0-500 volt) 96mm x 96mm having accuracy class 1.0, 4.5 digit LED display - 01 No (d) Digital Ammeter three Phase having accuracy class 1.0, 4.5 digit 0.5 VAburden with LED display, size 96mm x 96mm with 3 Nos CT (200/5)- 01 NoOUTGOING:-(a) MCCB, 3P, 63 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 04 Nos(b) MCB 40 Amp SPN10 KA \"C\" series, 230 volts, AC, 50 Hz- 12 NosNOTE:-(i) Wiring of panel board shall be with using multistranded copper wire of suitable size and gauge with connector, copper lugs all as required at site.(ii) The rate quoted by tenderer also includes to fix the legs of the panel box in PCC 1:3:6 pot hole foundation 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. |
| 37 | S&F Bus bar chamber panel board outdoor top canopytype, made out of 3.15 mm thick CRCA sheet weather/vermin proof, front door open type, 3 phase 4 wire, 440 volts , AC, 50Hz, with 4 Pole aluminium bus bar of capacity 100 Amps rated with PVC insulated colour code sleves, mounted on porceclain insulators, complete with R-Y-B indicating lamps, duly wired including locking arrangement , cable gland for incoming and outgoing cables of suitable sizes, panel size not less than 500mm x 500mm x 400mm, mounting MS angle base frame duly painted with synthetic enamel black paint and totally mounted on PCC(1:3:6) foundation upto a height of 45 cm above ground level complete all as specified and directed |
| 38 | M&L for Two coats aluminium paint over the exisiting steel tubular poles 7.5 - 9.20 mtrs above ground including cross arms/ bracings/clamps etc and 1.5 meter zebra lines with black & yellow colour paint bottom of the pole, after cleaning the existing poles and making good surface all surrounding and writing the pole numbers with white letters on black backgroundall as specifeid and directed by the Engr-in-charge. |
| 39 | Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways completeall as specified & directed. |
| 40 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge. |