| 1 | Sub Head-I Operation & Maintenance Sub-Station, DG set and IEIRunning Maintenance and Operation of Sub-Station Equipment having dry type transformers 2500KVA - 3 No. and D.G Set of capacity 1500 KVA – 2 Nos. with PLC/SCADA based system with all allied accessories, sports lighting along with PLC/SCADA system, external lighting, home lighting and electrical installation as per terms & conditions including routine and preventive maintenance as per details of installations are given in Annexure-C,D, E,F, M,N & O attached.Operation shall be done by deployingi) 1 No. Operator cum Electrician in each shift (total 3 shift) & 1 No. Khallasi in each shift (total 2 shift). |
| 2 | Running Maintenance and Operation of external lighting, home lighting and electrical installation as per terms & conditions including routine and preventive maintenance as per details of installations are given in Annexure A and B attached. Opeartion shall be done by deploying.i) 1 No. Operator cum Electrician& 1 No. Khallasi in general shift. |
| 3 | Servicing of Dry type 3 x 2500 KVA transformer through OEM/authorized aent of Kirloskar Make i/c cleaning checking & setting or winding temperature meter as per specification complete as reqd. |
| 4 | Carrying out \"B\" Check of the individual D.G Set (Capacity 1500 KVA, Cummins Make, Model KTA50G81) from OEM / authorized dealer.i) Element lub oil filter, Qty- 4ii)Kit fuel filter and ring, Qty- 2 iii) Kit super BYP Filter element, Qty-2iv) Seal O Ring, Qty-2 v)Inhibitor Corrosion 20 liters, Qty-2vi) Valvoline premium blue 7800 plus 1/210 Ltr, Qty-1vii) B check maintenance service charges, Qty- 1 viii) Kit air cleaner elements(K,QSK,V series), Qty-2ix)Radiator cleaning/descaling charges, Qty- 1 x) Inhibitor corrosion 05 Ltr, Qty- 2 |
| 5 | Testing & calibration of HT Panels through OEM/authorized agent of Kirloskar Make i/c checking of internal connection, cleaning of relays and setting the relays according to load current etc. |
| 6 | Servicing, cleaning, checking of all parts of 3/4 Pole LT 415 V ACB\"s through OEM/authorized agent of Kirloskar Make i/c indicating lighting, tightening of loose connections as per specification, rectification of control wiring, circuits etc. as reqd (800A / 1000A / 2000A / 2500A |
| 7 | Supply and replacement (i/c deduction of cost for replaced item) of following LED lights with all accessories i/c connection interconnection and testing etc as required. 20watt aluminum battan (1200 MM Long) LED light with IP :20 fixed on surface of wall and roof |
| 8 | 36 watt fixture (600MMx600MM ) LED light with IP :20 Fixed on surface/recess of roof. |
| 9 | Supplying and replacement (including deduction of cost for replaced item) of following sizes of aluminum conductor XLPE insulatedPVC inner sheathed armoured cable 1.1 KV grade confirming to IS:7098 (Part-I) complete with all amendments etc as required:-2 x 16 Sq.mm |
| 10 | 4x50 Sq.mm |
| 11 | Supply and replacement of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 12 | Supplying and replacement (including deduction of cost for replaced item) of 1.5 sqmm ISI marked, FRLS PVC insulated, single core copper conductor cable etc. as required. |
| 13 | Supplying and replacement (including deduction of cost for replaced item) of 2.5 sqmm ISI marked, FRLS PVC insulated, single core copper conductor cable etc. as required. |
| 14 | Supplying and replacement (including deduction of cost for replaced item) of 4.0 sqmm ISI marked, FRLS PVC insulated, single core copper conductor cable etc. as required. |
| 15 | Providing and Fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panels board including drilling holes in cubical panels, making connections etc. as required.100 A, 30KA, MCCB |
| 16 | 125 A, 36KA, MCCB |
| 17 | Supplying and fixing 5A to 32A rating, 240/415V, 10kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commissioning etc. as required.Single Pole |
| 18 | Single Pole and neutral |
| 19 | Double Pole |
| 20 | Sub Head-II Operation & Comprehensive Maintenance ofFire Alarm & Fire FightingRunning Maintenance and Operation of Addressable Fire Alarm System and Fire Fighting System and all allied accessories including routine and preventive maintenance. Details of installations are given in Annexure-G. Schedule for routine and preventive maintenance is given in Annexure-H & I. Operation shall be done by deploying 1 No. Operator cum Technician& 1 No. Khallasi in each shift (total 3 shifts) etc. as required. |
| 21 | Comprehensive Maintenance of fire alarm panel and programming/re-programming to make system in healthy condition. |
| 22 | Servicing of Diesel Engine (for fire pump) 72 BHP of Kirloskar make including supplying and replacement of following items testing etc as required. a) Kit element oil filter -1 setsb) Kit fuel filter element (primary & secondary) – 2 setsc) Coolant (1 ltr.)d) Air filter (inner & outer ) – 1 setse) Lube Oil – 15 Ltr |
| 23 | Comprehensive maintenance (routine, preventive and breakdown) of complete PLC and SCADA System alongwith sports lighting and Running maintenance of Sports lighting& Associated equipments installed as per details of installation given in Annexure ‘M’, ‘N’ andschedule of routine & preventive maintenance given in Annexure ‘O’ etc complete as required. |