| Sl. No. | Item Description |
| 1 | EARTH WORKS |
| 2 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 3 | All Kinds of Soil |
| 4 | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 5 | Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidating & dressing complete. |
| 6 | CONCRETE WORKS: |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level: |
| 8 | 1:4:8 (1 Cement:4 coarse sand:8 graded stone aggregate: 40 mm nominal size) |
| 9 | 1:5:10 (1 Cement: 5 coarse sand:10 graded stone aggregate: 40 mm nominal size) |
| 10 | Providing & laying damp-proof course 50 mm thick with cement concrete cement concrete 1 : 2 : 4 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 11 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth |
| 12 | R.C.C. Work |
| 13 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: |
| 14 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 15 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 16 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 17 | R.C.C. work in beams, suspended floors, roofs having slope uptp 15o landings, balconies, shelves, chajjas,lintels, band, plain window sills, staircases and spiral staircases above plinth level upto floor fivelevel excluding the cost of centering, shuttering, finishing and reinforcement, with 1 : 1 .5: 3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) |
| 18 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 19 | Thermo-Mechanically Treated bars |
| 20 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 21 | Thermo-Mechanically Treated bars |
| 22 | FORM WORK |
| 23 | Centering and shuttering including strutting,propping etc.and removal of form for : |
| 24 | Foundations, footings, bases of columns, etc. for mass concrete |
| 25 | Columns, pillars, posts and struts |
| 26 | Lintels, beams, plinth beams, girders, bressumers and sqm cantilevers |
| 27 | Suspended floors. roofs, landings, balconies and access platform, with water proof ply 12mm thick. |
| 28 | BRICK WORKS: |
| 29 | Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: |
| 30 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 31 | Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in |
| 32 | Cement mortar 1 : 4 (1 cement : 4coarse sand) |
| 33 | WOOD WORKS |
| 34 | Providing wood work in frames of doors, windows, clerestory windows and other frames.wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately |
| 35 | Local best quality Uningthou wood |
| 36 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. |
| 37 | Local best quality Tolhao Wood |
| 38 | 35 mm thick Shutters |
| 39 | Providing and fixing bright finished brass door latch with necessary screws etc. complete |
| 40 | 250 x 16 x 5 mm |
| 41 | Providing & fixing bright finished brass Tower bolts (barrel type) with necessary screws etc. complete. |
| 42 | 250x10 mm |
| 43 | Providing and fixing chromium plated brass handles with necessary screws etc. complete: |
| 44 | 125 mm |
| 45 | STEEL WORKS |
| 46 | Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting. hoisting fixing in position and applying a priming coat of approved steel primer, includingwelding and bolted including special shaped washers etc.complete |
| 47 | Etoctric resistanco or induction butt welded tubes |
| 48 | Providing and fixing stainless steel ( Grade 304) railing made ofHollow tubes, channels, plates etc., including welding, grinding, buffinge polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 49 | FLOORING: |
| 50 | Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shadecomplete. |
| 51 | Marble tiles (polished) Raj Nagar |
| 52 | 18mm thick |
| 53 | Marble stone flooring with 18mm thick marble stone (sample Of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with |
| 54 | Raj Nagar Plain |
| 55 | Extra for prefinished nosing to treads of steps of marble stone. |
| 56 | Providing and fixing 1st quality ceramic glazed wall tiles conformingto IS : 15622 (thickness to be specified by the manufacture of approved make in alt colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (I cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 57 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption\"s less than 0.080/0 and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. |
| 58 | Size of Tile 600 x 600 mm |
| 59 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of25x25xO.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.l. channels 45x15xO.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to Gil. intermediate channel with connecting clips made out of 2.64mm diax230mm long C.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/pattition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed. all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with |
| 60 | 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part l, |
| 61 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineerincharge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using selt drilling Iself tapping screws ot size (5.5x 55 mm) with EPDM seal,comptete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with |
| 62 | Precoated galvanised iron profile sheets 0.40 mm thick |
| 63 | Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts andnuts and or C.I. seam bolts and nuts, G.l. plain and bitumen washers complete |
| 64 | Ridges plain (500 - 600mm) |
| 65 | Gutter (600 mm over all girth), |
| 66 | Precoated galvanised iron profile sheets 0.40 mm thick |
| 67 | FINISHING: |
| 68 | 12 mm cement plaster of mix 1:4 (1 cement:4 coarse sand). |
| 69 | (1 cement:4 coarse sand) |
| 70 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement:4 coarse sand). |
| 71 | 1:4 (1 cement:4 coarse sand). |
| 72 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. |
| 73 | New work(two or more coats)over and including priming coat with cement primer |
| 74 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface |
| 75 | Water thinnable cement primer |
| 76 | Finishing walls with textured exterior paint of required shade: |
| 77 | New Work(two or more coats applied @3.28ltr/10 Sqm)over and including base coat of water proofing cement paint [email protected]/10 sqm. |
| 78 | Applying priming coat:- |
| 79 | With ready mix pink or grey primer of approved brand and manufacture on wood work(hard and soft wood) |
| 80 | Painting (two or more coats) with synthetic enamel paint of approved brand and manufacture to give an even shade. |
| 81 | Two or more coats on new work |
| 82 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaece to prepare the surface even and smooth |
| 83 | Construction of Toilet Block |
| 84 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m |
| 85 | All kinds of soil. |
| 86 | Filling availabte excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layerby ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 87 | Supplying and filling in plinth with sandy soil under floors including, cum watering,ramming consolidating and dressing complete. |
| 88 | CONCRETE WORK : |
| 89 | Providingand layingcement concretein foundation and plinth excludingthe cost of centering andshuttering in |
| 90 | 1:4:8 ( 1cement:4 coarse sand:8 gradedstone aggregate 40mm nominal size) |
| 91 | 1:5:10(1 Cement:5 coarse sand:10 graded stone aggregate: 40 mm nominal size) |
| 92 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (Icement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 93 | Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1 cement:3 coarse sand:6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth. |
| 94 | RCC WORK |
| 95 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 96 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 97 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement |
| 98 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 99 | Reinforced cement concrete work in beams, suspended floors,roofs having stope upto 15o 9 landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 100 | STEEL REINFORCEMENT |
| 101 | Reinforcementfor RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 102 | a)Thermo-Mechanically Treated bars |
| 103 | Form Work |
| 104 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 105 | Foundations, footings, bases of columns, etc. for mass concrete |
| 106 | Lintels, beams, plinth beams, girders, bressumers ands cantilevers. |
| 107 | Suspended floors, roofs, landings, balconies and access |
| 108 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 109 | BRICK WORK |
| 110 | Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: |
| 111 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 112 | Half brick masonry 2nd class (local 1st class) in cement mortar 1:3 (1 cement : 3 coarse sand) insuperstructure. |
| 113 | Cement mortar 1 : 3 (1 cement : 3 coarse sand) |
| 114 | Brick edging 7cm wide 11.4 cm deep to plinth protection with 1st class common burnt clay F.P.S. ( non- modular) bricks including grouting with cement mortar 1:4 (1cement:4fine sand) |
| 115 | WOOD WORK |
| 116 | Providing wood work in frames of doors, windows, clerestory windows and other frames.wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately |
| 117 | a) Local best quality Teak Wood |
| 118 | Providing and fixing panellod or panollod and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.. |
| 119 | a) Local best quality Teak Wood |
| 120 | 35 mm thick shutters |
| 121 | Providing & fixing M.S. grills of required pattern to wooden frames of window etc with M.S. flats at required sparings & frames all round bars with round headed bolts & nuts or by srcews. |
| 122 | Plain grill |
| 123 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. Complete |
| 124 | 250x10 mm |
| 125 | 100x10 mm |
| 126 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete |
| 127 | 125 mm |
| 128 | 75mm |
| 129 | FLOORING |
| 130 | Providing and laying Vitrified tiles in floor in diffe rent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.080/0 and conforming to 19.15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will bo done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubbermallet for placing the tiles gently and easily. |
| 131 | Sizes of Tiles 600x600 mm (Double charged) |
| 132 | Providing and laying vitrified tiles in different sizes (thickness to be specefied by manufacture), with water absorption less than 0.08% and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement motar 1:3 (1cement:3c/sand), jonting with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 133 | sizes of tile 500x500 mm |
| 134 | Marble stone flooring with 18mm thick marble stone (sample Of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with |
| 135 | Raj Nagar plain |
| 136 | FINISHING |
| 137 | 6mmcement plasterof mix : |
| 138 | 1:3 ( 1 cement : 3 f/s ) |
| 139 | 15 mm cement plaster 1:3(1 cement : 3coarse sand) |
| 140 | 15 mm cement plaster on rough side of single or half brick wall of mix |
| 141 | 1:4 (1 cement: 4 coarse sand) |
| 142 | White washing with lime on new work (three or more coats ) to give an even shade. |
| 143 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade |
| 144 | New work (two or more coats) over and including priming coat with cement primer:- |
| 145 | Applying one coat of cement primer of approved quality on wall surface : |
| 146 | finishing walls with Acrylic smooth exterior paint of required shade : |
| 147 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cemont paint applied @ 2.20 kg/ 10 sqm). |
| 148 | Painting with oil type wood preservative of approved brand and manufacture. |
| 149 | New work( Two or more coats) |
| 150 | SANITARY INSTALLATIONS |
| 151 | Providing and fixing white vitreous china water closet squatting pan |
| 152 | Orissa pattern. |
| 153 | 580x410 |
| 154 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device ( handle lever ) conforming to IS: 7231, with all |
| 155 | 10 litre capacity- white |
| 156 | Providing and fixing white vitreous china flat back or wall corner typeb lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 157 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. |
| 158 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : |
| 159 | Flat back wash basin of size 630x450 mm |
| 160 | Providing and fixing grating for gully trap or Nahni trap. |
| 161 | Stainless stell |
| 162 | 100 mm nominal diameter |
| 163 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 164 | Flexible pipe |
| 165 | 40 mm dia. |
| 166 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 167 | Providing and fixing 610 x 20 mm Diplomat brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws |
| 168 | Providing and fixing soap container of glass with C.P. lid and brackets fixed to wooden cleats with C.P. brass screws. |
| 169 | Providing and fixing 100 mm H.C.I. soil vent pipes. |
| 170 | Providing and fixing MS holder bat clamps of approved design to 100 mm HCI pipe socket i/c cost of cutting holes and making good the walls etc. |
| 171 | Providing and fixing 100 x 100 x 100 mm HCI branch of the required degree with access doors, insertion rubber washer 3 mm thick bolts and nuts complete. |
| 172 | Providing and fixing 100 mm HCI bend of the required degree with access door insertion rubber washers bolts and nuts etc. complete. |
| 173 | Providing and fixing 100 mm HCI plain bend of required degree. |
| 174 | Providing and fixing 100 mm HCI collar |
| 175 | Providing and fixing 50 mm H.C.I. soil vent pipes. |
| 176 | Providing and fixing MS holder bat clamps of approved design to 50 mm HCI pipe socket i/c cost of cutting holes and making good the walls etc. |
| 177 | Providing and fixing 50 x 50 x 50 mm HCI branch of the required degree with access doors, insertion rubber washer 3 mm thick bolts and nuts complete. |
| 178 | Providing and fixing 50 mm HCI band of the required degree with access door insertion rubber washers 3 mm bolts and nuts etc. complete. |
| 179 | Providing and fixing 50 mm HCI plain band of required degree. |
| 180 | Providing and fixing HCI traps with 100 mm inlet and 100 mm outlet of self cleaning design with HCI screwed down of hinged grating with or without vent arm complete i/c cost of cutting and making good the walls and floors |
| 181 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. |
| 182 | 15 mm |
| 183 | 20 mm |
| 184 | 25 mm |
| 185 | 32 mm |
| 186 | Making connection of GI distribution branch with GI main 25 mm to 40 mm diameter by providing & fixing Tees i/c cutting and threading the pipe etc complete. |
| 187 | Providing and fixing C.P. bib cock of superior quality. : |
| 188 | 15 mm diameter ( ordinary) |
| 189 | Providing and fixing brass stop cock of superior quality. |
| 190 | 15 mm diameter |
| 191 | Providing and fixing brass full way G.M valve with CI wheel of approved |
| 192 | 25 mm diameter |
| 193 | 32 mm diameter |
| 194 | Providing and fixing C.P. brass shower rose with 12.5 or 19 mm inlet : |
| 195 | 100 mm diameter |
| 196 | Repainting G.I. pipes and fittings with white paint of approved quality |
| 197 | 25 mm dia pipe |
| 198 | 32 mm dia pipe |
| 199 | Providing and fixing WATER STORAGE TANKS (Sintex) with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level. |
| 200 | 2000 litres net capacity storage tanks |
| 201 | Construction of Compound Fencing |
| 202 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 203 | All Kinds of Soil |
| 204 | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 205 | Cement concrete |
| 206 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level: |
| 207 | 1:4:8 (1 Cement:4 coarse sand:8 graded stone aggregate: 40 mm nominal size) |
| 208 | R.C.C. |
| 209 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: |
| 210 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 211 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 212 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 213 | R.C.C. work in beams, suspended floors, roofs having slope uptp 15o landings, balconies, shelves, chajjas,lintels, band, plain window sills, staircases and spiral staircases above plinth level upto floor fivelevel excluding the cost of centering, shuttering, finishing and reinforcement, with 1 : 1 .5: 3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) |
| 214 | STEEL REINFORCEMENT |
| 215 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 216 | Thermo-Mechanically Treated bars |
| 217 | FORM WORKS |
| 218 | Centering and shuttering including strutting,propping etc.and removal of form for : |
| 219 | Foundations, footings, bases of columns, etc. for mass concrete |
| 220 | Columns, pillars, posts and struts |
| 221 | Lintels, beams, plinth beams, girders, bressumers and sqm cantilevers |
| 222 | BrickWorks |
| 223 | Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in |
| 224 | Cement mortar 1 : 4 (1 cement : 4coarse sand) |
| 225 | STEEL WORKS: |
| 226 | Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting. hoisting fixing in position and applying a priming coat of approved steel primer, includingwelding and bolted including special shaped washers etc.complete |
| 227 | Etoctric resistanco or induction butt welded tubes |
| 228 | Finishing |
| 229 | 12 mm cement plaster of mix 1:4 (1 cement:4 coarse sand). |
| 230 | (1 cement:4 coarse sand) |
| 231 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement:4 coarse sand). |
| 232 | 1:4 (1 cement:4 coarse sand). |
| 233 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface |
| 234 | Water thinnable cement primer |
| 235 | Finishing walls with textured exterior paint of required shade: |
| 236 | New Work(two or more coats applied @3.28ltr/10 Sqm)over and including base coat of water proofing cement paint [email protected]/10 sqm. |
| 237 | Supplying and fixing galvanised steel barbed wire.weighing 9.38kg/100 m straining and fixing to any type of standard rails straining bolts i/c securing with and provision of galvanised mild steel wire, staples or steel pins etc as directed (Posts and struts of wood, concrete, steel and straining bolts shall be paid separately). |
| 238 | Construction of Main Gate |
| 239 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 240 | All Kinds of Soil |
| 241 | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 242 | CONCRETE WORK : |
| 243 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level: |
| 244 | 1:4:8 (1 Cement:4 coarse sand:8 graded stone aggregate: 40 mm nominal size) |
| 245 | RCC WORK : |
| 246 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: |
| 247 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 248 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 249 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 250 | R.C.C. work in beams, suspended floors, roofs having slope uptp 15o landings, balconies, shelves, chajjas,lintels, band, plain window sills, staircases and spiral staircases above plinth level upto floor fivelevel excluding the cost of centering, shuttering, finishing and reinforcement, with 1 : 1 .5: 3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) |
| 251 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 252 | Thermo-Mechanically Treated bars |
| 253 | FORM WORK : |
| 254 | Centering and shuttering including strutting,propping etc.and removal of form for : |
| 255 | Foundations, footings, bases of columns, etc. for mass concrete |
| 256 | Lintels, beams, plinth beams, girders, bressumers and sqm cantilevers |
| 257 | Columns, pillars, posts and struts |
| 258 | BRICK WORK : |
| 259 | Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in |
| 260 | Cement mortar 1 : 4 (1 cement : 4coarse sand) |
| 261 | Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting. hoisting fixing in position and applying a priming coat of approved steel primer, includingwelding and bolted including special shaped washers etc.complete |
| 262 | Etoctric resistanco or induction butt welded tubes |
| 263 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement:4 coarse sand). |
| 264 | 1:4 (1 cement:4 coarse sand). |
| 265 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface |
| 266 | Water thinnable cement primer |
| 267 | Finishing walls with textured exterior paint of required shade: |
| 268 | New Work(two or more coats applied @3.28ltr/10 Sqm)over and including base coat of water proofing cement paint [email protected]/10 sqm. |
| 269 | Providing Internal Electrification Installation. |
| 270 | Wiring for light point / Fan point / Exhaust Fan point / Call bell point with 1.5 mm. FR PVC insulated copper conductor single core cable in surface / recessed steel conduit with modular type switch modular plate, suitable G.I. box and earthing the point with 1.5 mm 2 FR PVC insluted copper conductor single core cable etc., as reqd. |
| 271 | Group - A |
| 272 | Group - B |
| 273 | Group - C |
| 274 | Wiring for twin control point with 1.5 sqmm FR PVC insulated copper conductur single core cable in surface/recessed steel conduit, 2 way modular type switch, modular plate suitable size GI box and earthing the point with 1.5 sqmm FR insulated copper conductor single core cable etc. as required. |
| 275 | Wiring for light pt/power plug with 4x4mm2 FR pvc ins. Cu.cond.s/c cable in surface /recessed steel conduit alongwith one no. 4mm2 FR pvc.ins.Cu.cond. s/c cable for loop earthing etc.as reqd. |
| 276 | Wiring for circuit/ Sub-main wiring along with earth wire with (the following sizes) of FR PVC insulated copper conductor single core cable in surface / recessed steel conduit etc. as reqd. |
| 277 | 2x2.5mm2+1x2.5mm2 earth wire |
| 278 | 2x4mm2+1x4mm2 earth wire |
| 279 | 2x6mm2+1x6mm2 earth wire |
| 280 | Supplying Wiring in existing conduit |
| 281 | Supplying and drawing (following pait) 0.5sqmm FR PVC insulated copper conductor unarmoured telephone cable in the existing surface/recessed steel/PVC conduit reqd. |
| 282 | 2 pair |
| 283 | TV Cable in existing conduit |
| 284 | Supplying and drawing Co-Axial TV cable RG-6 grade 0.7mm solid copper conductor PE insulated shielded with file tinned copper braid and protected in PVC sheath in existing surface/recessed steel/PVC conduit as reqd |
| 285 | S/F (following Modular type switch/socket) on the existing switch box i/c connectionetc.as reqd. |
| 286 | 5/6 amps. Switch |
| 287 | 2 way 5/6 amps switch |
| 288 | 15/16 amp.s switch |
| 289 | 3 pin 5/6 amps.socket outlet |
| 290 | 6 pin 15/16 amps.socket outlet |
| 291 | Telephone socket outlet |
| 292 | TV antenna socket outlet |
| 293 | Supplying & fixing stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc. as reqd. |
| 294 | S/F (following size/modular switch plate base and cover plate for modular switch in recess SSS as reqd. |
| 295 | 1 or 2 module (75mmx75mm) |
| 296 | 6 module |
| 297 | 8 module |
| 298 | 12 module |
| 299 | S/F 3 pin amp ceiling rose on the existing junction box/wooden box i/c connection etc. reqd. |
| 300 | Supply and fixing Bell Push Modular Type |
| 301 | Providing and Fixings (following capacity TP & N) dis-connection fuse switch unit inside the existing cubicle panel board with ISI marks HRC fuses including drilling holes in the cubicle panel board, making connection as reqd. |
| 302 | 400 amp. T.P. & N |
| 303 | S/F (following way) single door pole & neutral, sheet MCCB distribution board, 240V on surface/recessed complete with tinned Cu.bus bar neutral bus bar, earth bar, din bar detachable gland plate, interconnection, phosphatized and power painted i/c earthing etc.as reqd. (But without MCB/RCCB/Isolator) |
| 304 | 2+8way |
| 305 | S/F 5 amp. to 32 amp.rating 230V \"B\" series MCB for lighting and other load of (following pole) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. |
| 306 | Single pole |
| 307 | S/F (following rating) double pole 240V isolator in the existing MCB DB complete with connection, testing and commissioning as reqd. (a) 63 amp. |
| 308 | 63 amp |
| 309 | S/F bus bar chamber with 4 strips Cu. Bus bar length 900mm suitable suitable for 200 amp.capacity complete with all accessories i/c connection earthing the body etc.as reqd. |
| 310 | S/F 48\" (1200mm) A.C. ceiling fan complete with down rod, canopy, 3 (three) blades but without regulator etc as reqd. (Make Bajaj/ Usha or similar |
| 311 | S/F 305mm sweep exhaust fan complete with all accessories i/c connection etc as reqd |
| 312 | Supplying, Erection, testing and commissioning of (pre-wired) wall bracket/ceiling fittings of all sizes and shapes containingCFL/LED/W GLS lamps per fitting, complete with all accessories including connection etc. as required(havell,s /Bajaja/Phillips/Cromton). |
| 313 | Ceiling fitting (Surface) with 12/15 watt LED Lamp. |