Tender For Sitc Of Roof Top Grid Connected Solar Power Plant In Lm Sports Complex And Bed Minton Academy Back Side Mm Ground Nathusar Bas Ward No 43 Bikaner Under Mla Fund Scheme Ew, Bikaner-Rajasthan
TDR : 48854285
Tender Notice
BOQ
Expired
Bikaner
Rajasthan
Tender For Sitc Of Roof Top Grid Connected Solar Power Plant In Lm Sports Complex And Bed Minton Academy Back Side Mm Ground Nathusar Bas Ward No 43 Bikaner Under Mla Fund Scheme Ew
Name of Work: SITC of Roof Top Grid Connected Solar Power Plant in LM Sports Complex & Bed Minton Academy Back Side MM Ground Nathusar Bas Ward No:-43 Bikaner ( Under MLA Fund Scheme) (EW)
Sl. No.
Item Description
1
NON BSR Item
2
Supplying , installation , Testing and commissioning of grid connected SPV power plant in accordance with latest MNRE and ALMM approved specifications/ Indian standards with comprehensive maintenance as per following details :
3
(a)SITC of Monocrystalline standard IP-65 Half cut 144 cell PV Module of minimum rating 540/550 watt with eqal no. of module to be in each series circuit . Frame made out from Anodized Allunimium alloy with hot dippedgalvanized steelmounting structure , civil structure , lightning and over volage protection , earthing protection as per specification as required for making the solar system functional complete in all respect as required.
4
(b) SITC of IP-65 rating wall/floor mountedstring inverter 3 phase, low maintenance , full sine wave ,50 Hz AC out put with grid tied features along with all protection , controlling arrangement and required accessories ( as per MNRE specification ) of following capacity .The inverter AC nominal power out put rating must be equal or greater than the required KWp of the module at standard test condition (STC). The inverter unit shall be suitable for indoor and outdoor installations including all DC/AC Plugs and socket, DB\"s and with all necessary electrical DC solar cables between modules and inverters and AC cables for connecting the inverter to the AC Junction Box and panel ( as per site requirement) and lugs and terminations with solar metering and net metering, conduits and cable trays and all other material and workmanship required to connect with main distribution panel as per the direction of engineer-in-charge.
5
(C) Appropriate Test Certificate / Report with Liable warranty of product / accessories from OEM shall be submitted before work order. All as per pre approved by engineer in charge for additional technical parameters of product/work , refer Annexure \"A\" attached with PWD Electrical B.S.R. 2022