| 1 | Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, pier holes, for foundations of poles, struts, stays etc. or layingunderground cable and water supply pipe lines etc.in hard/dense soil/rocks,& getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge. |
| 2 | Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil/\ complete all as specified and directed by Engineer-in-charge. |
| 3 | Removal of excavated soil material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge. |
| 4 | Taking up or down 15mm bore galvanised steel water tubing including connections, fixed in walls, ceiling or laid under floor or laid in trenches etc complete all as specified and directed by Engineer-in-charge.Note :-Excavation and earthwork shall be measured and paid for separately. |
| 5 | All as per Srl item No 4 above but 20 mm dia bore. |
| 6 | All as per Srl item No 4 above but 25 mm dia bore. |
| 7 | All as per Srl item No 4 above but 40 mm dia bore. |
| 8 | All as per Srl item No 4 above but 50 mm dia bore. |
| 9 | All as per Srl item No 4 above but 80 mm dia bore. |
| 10 | All as per Srl item No 4 above but 100 mm dia bore. |
| 11 | All as per Srl item No 4 above but 150 mm dia bore. |
| 12 | S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge. |
| 13 | All as per Srl item No 12 above but 20 mm dia bore. |
| 14 | All as per Srl item No 12 above but 25 mm dia bore. |
| 15 | All as per Srl item No 12 above but 40 mm dia bore. |
| 16 | S&F 50mm bore galvanized steel water tubing medium grade with & including all fittings, laid in trenches complete all as specified and directed by Engineer-in-charge. |
| 17 | All as per Srl item No 16 above but 80 mm dia bore. |
| 18 | Supplying, laying, jointing, commissioning and testing 100mm bore centrifugally cast (Spun)ductile iron pressure pipe with spigot and socketed ends class K-7, confirming to IS : 8329/2000 blast furnace slag cement with portland cement properties suitable for rubber gasket jointing / tyton joints with inside cement mortar lining and black bitumen external coating, duly (ISI marked) laid in trenches complete all as specified and directed by Engineer-in-Charge. Note :- (i)DI fittings shall be measured and paid separately under respective items (ii)Pipes shall be laid in trenches already excavated for taking out old GI pipe line. Extra excavation / earthwork shall not be paid. |
| 19 | All as per Srl item No 18 above but 150 mm dia bore. |
| 20 | S&F in replacement gun metal globe or gate valve 20mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge. |
| 21 | All as per Srl item No 20 above but 25 mm dia bore. |
| 22 | All as per Srl item No 20 above but 40 mm dia bore. |
| 23 | All as per Srl item No 20 above but 50 mm dia bore. |
| 24 | Supplying, fixing and testing in replacement of 80mm bore cast iron sluice valve with langed ends drilledISI marked conforming Class PN 1.6 to IS 14846-2000with stainless steel spindle with iron wheel, CI gatewith brassnut, bolts, washers and rubber packing for connecting pieces etccomplete all as specified and as directed by Engineer-in-Charge. |
| 25 | All as per Srl item No 24 above but 100 mm dia bore. |
| 26 | All as per Srl item No 24 above but 150 mm dia bore. |
| 27 | S&F Cast iron non return valve / reflux valve with rubber seat flanged type with by pass arrangement suitable for 80mm bore pipe, ISI marked, conforming to IS- 5312/2004 with stainless steel spindle, CI gate with brass nuts, bolts, washers and jointing with necessary ruber gasket etc including dismantling & taking out old unserviceable sluice valve of 80 mm bore, complete, all as specified & directed. |
| 28 | All as per Srl item No 27 above but 100 mm dia bore. |
| 29 | Supplying & fixing DI fittings confirming to IS-9523-2000 suitable for spigot & socketed pipes such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc),tee pieces, single branch, \"Y\" junction, double branch, cross collar, caps and plugsetc. suitable for spigot and socketed pipes upto 150 mm bore, complete, all as specified and directed by Engineer-in-charge. |
| 30 | M&L for Construction of brick masonry valve pit, in repair, of internal size 60cm x 60cm x 60cm including necessary excavation and earth work in soft/loose soil, brick work,plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 3 mm thickfixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock ,complete all as specified and directed by Engineer - in - ChargeNote :- (i)Brick wall shall be 23 cm thickbuilt incement mortar (1:4)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds.(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls. (iv) PCC coping shall be 15 cm thick in cement concrete ( 1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Three coats of white wash to internal surfaces of valve pit.(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation. |
| 31 | All as per Srl item No 30 above but internal size 90cm x 90cm x 90cm |
| 32 | All as per Srl item No 30 above but internal size 150cm x 150cm x 90cm |
| 33 | M&L for \"D\" Joint suitable for DI /CI/GIpipe sizes 50 mm dia bore including excavation work and other fittings as required including testing at site complete all as specified and directed by the Engineer-in-Charge. |
| 34 | All as per Srl item No 33 above but 80 mm dia bore. |
| 35 | All as per Srl item No 33 above but 100 mm dia bore. |
| 36 | All as per Srl item No 33 above but 150 mm dia bore. |
| 37 | S & F in repair15mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixedall as specified and directed. |
| 38 | All as per Srl item No 37 above but 20 mm dia bore. |
| 39 | All as per Srl item No 37 above but 25 mm dia bore. |
| 40 | Supply and fixing in repairhigh jet fountain nozzle with orifice size 19 mm and suitable with 40 mm dia pipe. |
| 41 | S&F in replcementFRP junction box for street light central with linked door control incl 6 amp MCB SP with aluminium bus bar-04 nosfor controling street light/garden lightcomplete as directed by Engr-in-Charge. |
| 42 | Surface cleaning by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds by excavation not exceeding 15cm deep including sweeping removing the same to distance not exceeding 50m away from the installation and burning the same all as specified and directed by Engr-in-Charge. |
| 43 | Supplying and fixing in replacementof under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with standed aluminium conductor 4 core 16 sqmm laid in trenches/ duct/ pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engr-in-Charge. |
| 44 | All as per itme No 43 above but 3.5 core 25 Sqmm |
| 45 | Material and labour in repair for earthing complete with copperplate electrode 60cmx60cmx3.15mm thick, buried directly in ground, vertically to a dpeth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not lss than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead copper strip 20 x 3 mm by means of bolts, nuts, check-nuts and wahsers of galvanised iron and thimbles and of earth wire protected by galvanised iron pipe light grade 40mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh complete 1:3:6 type C-1 using 20mm graded stone aggregate in lieu of CI cover and frame etc all as specified and directed. |
| 46 | S&F in replacement 80mm dia butterfly valve complete all as specified and directed by Engineer-in-charge. |
| 47 | All as per Srl item No 46 above but 100 mm dia bore. |
| 48 | All as per Srl item No 46 above but 150 mm dia bore. |
| 49 | All as per Srl item No 46 above but 200 mm dia bore. |
| 50 | S & F double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 (Part I and II ) for protection of underground cable .Outer dia of pipe 50 mm with all fitting laid in trenches/road/nallah or fixed along wall ,poles or laid under floor (including cutting floor /Road and making good to match with existing adjointing surface etc for cable protection all as specifiedand as directed. |
| 51 | Suppyling, installing, testing and commissioning of Indoor type factory made ,CRCA sheet ,thickness 3.15mm,platform mounted LT panel board to accommodate the following items and built upon angle iron frame suitable size compatmentalized design work ,dully powder coated with gray paint and suitable size of cable glands chromium plated and copper busbars TPN,250 Amps,415V,50Hz complete as following:-(i) MCCB 160 Amps,4 pole,36 Ka -01 (incoming)(ii) MCCB 63 Amps,4 pole,25 Ka -02 (outgoing)(iii) Voltmeter 0-500 V digital type with selector switch - 1 No.(iv) Amp meter 0-200 A digital type with selector switch -1 No.(v) Soft Starter suitable for 20 HP centrifugal monoblock multistage pump set-02 Nos(vi) Indicating lamp LED RYB set of three with colour coding -1 No. |
| 52 | Suppyling, installing, testing and commissioning of Indoor type factory made ,CRCA sheet ,thickness 3.15mm,platform mounted LT panel board to accommodate the following items and built upon angle iron frame suitable size compatmentalized design work ,dully powder coated with gray paint and suitable size of cable glands chromium plated and copper busbars TPN,250 Amps,415V,50Hz complete as following:-(i) MCCB 100 Amps,4 pole,36 Ka -01 (incoming)(ii) MCCB 63 Amps,4 pole,25 Ka -02 (outgoing)(iii) Voltmeter 0-500 V digital type with selector switch - 1 No.(iv) Amp meter 0-200 A digital type with selector switch -1 No.(v) Soft Starter suitable for 10/15 HP motor -02(vi) Indicating lamp LED RYB set of three with colour coding -1 No. |
| 53 | Supply and fix single core PVC insulated FR cable with multi stranded copper conductor 1.5 sq mm cross sectional area 3 core ,1100 volts grade including PVC conduit pipe all as specified and as directed. |
| 54 | Supply and fixing in replacementAquascape PF - 1500 12V X 50W fountain light with MR-16 lamp, connection cable made from bronze. Make: Aquascape Model PF-1500 or Equivalent |
| 55 | Supply and fixing in replacement high light intensity empowered colour changing and monochromatic LED10 W under water fountain light with polarized light design & intelligent logoarithmic control technology complete all as specified and as directed. |
| 56 | M&L sand cushioning / filling for underground cable protection, filling under floors ,consolidated and compacted with clean dry sand complete all as specified and as directed. |
| 57 | M & L stone Slab40 to 50 mm thick rough dressed jodhpur stone patties/ slab cover in trenches for protection of cable 25 to 30 CM wide and thickness not less than 50 mm in length lay dry abutting each other with gap between adjacent slab not exceeding 10 mm over sand cushioning. |
| 58 | Supplying, laying & jointing PVC water pipe 20 mm size complete all as specified & as directed by Engineer –in-charge. |
| 59 | M&L for taking out of Elect Motor 7.5 HP Capacity installed as motor from foundation after disconnecting electrical connections, dismantling motor and rewiding the same with super enamelled copper winding wire of existing gauge including varnishing, baking, cotton tape and greasing of bearings, bushes and other connected parts, reassembling and fixing the same in its original position including replacement of unserviceable nut-bolts, washer, lugs, terminal plate and making proper electrical connection complete all as specified and directed by Engineer-in-charge.Make of winding wire : - Devidayal / ChetakNote : - (i) Bearing if required for replacement shall be paid seprately (ii) Transportation of motor is included in the unit rate of items nothing extra shall be paid on this account |
| 60 | All as per serial item No 59 here-in-above but motor of capacity 5 HP |
| 61 | All as per serial item No.59 here-in-above but motor of capacity 3HP |
| 62 | All as per serial item No.59 here-in-above but motor of capacity 2 /1HP |
| 63 | Taking out centrifugal motor of any capacity from foundation, dismantling the motor, taking out rotor and filling the material by welding work, finishing by lathe machine, replacement of unserviceable bearing, reassembling the motor and fixed in its original position complete all as specified and directed by Engineer-in-charge.Note: - (i) Bearing shall be measured and paid for separately as “Supply only” (ii) New Nuts, bolts and washers if required for refixing the motor shall be provided by the contractor, nothing extra shall be paid on this account. |
| 64 | Supply only Ball Bearing of suitable size for rotor of motor 7.5 HP installed complete all as specified and directed by Engineer-in-charge. |
| 65 | All as per serial item No 63 here-in-above but for motor of 5 HP. |
| 66 | All as per serial item No 63 here-in-above but for motor of 3 HP. |
| 67 | All as per serial item No 63 here-in-above but for motor of 1/ 2 HP. |
| 68 | Taking out defective centrifugal pump set , assembled with 7.5 HP elelctric motor, dismantling the pump set for carrying out repair / replacement of unserviceable parts such as CI impeller, Bush, ball bearing etc. reassembling, installing, commissioning and testing complete all as specified and directed by Engineer-in-charge.Note :(i) CI impeller, Bush & ball bearing required to replace shall be measured and paid for separately under respective items of BOQ as “Supply only”.(ii) The cost of transportation is included in the unit rate of this item nothing extra shall be paid on this account. |
| 69 | All as per serial item No 68 here-in-above butpump setassembled with 5HP elelctric motor |
| 70 | All as per serial item No 68 here-in-above butpump setassembled with 2 /3HP elelctric motor |
| 71 | Supply only ball bearing suitable for centrifugal Pump set assembled with 7.5 HP motor complete all as specified and directed by Engineer-in-charge. |
| 72 | All as per serial item No 71 here-in-above but assembled with 5HP Motor |
| 73 | All as per serial item No 71 here-in-above but assembled with 3 HP Motor |
| 74 | Supply only stainless steel Bush suitable for pump set assembled with 7.5 HP motor complete all as specified and directed by Engineer-in-charge. |
| 75 | All as per serial item No 74 here-in-above but assembled with 5 HP Motor |
| 76 | Supplying, laying & jointing in replacement submersible cable flat type, copper conductor of size 10 Sqmm 3 core complete all as specified & as directed by Engineer –in-charge. |
| 77 | All as per serial item No.76 here-in-above but 6 Sqmm 3 core. |
| 78 | All as per serial item No. 76 here-in-above but 4 Sqmm 3 core. |
| 79 | S&F in replacement rubber coupling as per existing model & make suitable for centrifugal pump set assembled with 7.5 HP motor complete all as specified & as directed by Engineer –in-charge. |
| 80 | All as per serial item No. 79 here-in-above but assembled with 5 HP motor |
| 81 | M&L for rewiding of submersible pump set of capacity 5 / 7.5 HP with PVC insulated copper winding wire of existing gauge including varnishing, baking, cotton tape and greasing of bearings, bushes and other connected parts complete all as specified and as directed by Engineer –in-charge |
| 82 | S&F in replacement fully automatic star delta starter type ML2 FASD having relay of range 20 - 32 Amp including making electrical connection complete all as specified & as directed by Engineer-in-chargeMake :- L&T Cat Part No SS90705 or equivalent Crompton Greaves / ABB / Schneider / Seimens |
| 83 | S&F in replacement DOL starter range 13 - 22 Amp including making electrical connection complete all as specified & as directed by Engineer-in-chargeMake :- L&T Cat Part NoSS96228 or equivalent Crompton Greaves / ABB / Schneider / Seimens |
| 84 | S&F in replacement on / off switch (push button) complete all as specified & as directed by Engineer-in-charge |
| 85 | S&F in replacement indicating lamp with holder and cover as per existing complete all as specified & as directed by Engineer-in-charge |
| 86 | S&F in replacement MCCB 4 Pole 100 Amps, thermal magnetic releasehaving, breaking capacity 25 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars,making necessary welding work, metal work for fixing base plate etc and connectionscomplete all as specified and as directed by Engineer-in-Charge.Make : Legrand Cat Part No. DPX 160 420055 or equivalent in L&T / Schneider / Standard |
| 87 | All as per item No. 86 here-in-before but MCCB 4 Pole, 125 Amps rating, breaking capacity 25 KA, 415 Volt Make : Legrand Cat Part No. DPX 160 420056 or equivalent in L&T/ Schneider / Indoasian |
| 88 | All as per item No. 86 here-in-before but MCCB 4 Pole, 160 Amps rating, breaking capacity 25 KA, 415 Volt Make : Legrand Cat Part No. DPX 160 420057 or equivalent in L&T/ Schneider / Indoasian |
| 89 | Preparation of old painted steel surfaces of panel body of any size incl scrapping old paint, denting and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge. |
| 90 | M&L for complete removal of existing paint of Elect motor with pump including base frame and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge. |