Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-05-2025 | Date Corrigendum for NIe-T-11/2025-26 | Date | 21-05-2025 |
| Sl. No. | Item Description |
| 1 | Building Works Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbishwithin a lead upto 75 m as directed |
| 2 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1.500 mm. |
| 3 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. |
| 4 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layercomplete. (Payment to be made on the basis of measurement of finished quantity of work)a)With earth obtained from excavationof foundation |
| 5 | (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement offinished quantity) |
| 6 | Pre-constructional Anti-termite measures(c) Anti-termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrefos emulsifiable concentrates (1% concentration) with water by weight @ 5 litres / sq.m of the surface before sand bed or sub-grade is laid. Holes upto 50mm to 75mm deep at 150mm centre to centre both ways shall be made with 12mm diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in 6.4 of code IS-6313 (Part-II) 1981. (Mode of measurement will be per sq.m of plan area of plinth treated). |
| 7 | Post-construction Anti-termite measures(a) Anti-termite treatment to the outside of foundation with chemical emulsion by admixing chloropyrefos emulsifiable concentrates (1% concentration) with water by weight including cutting shallow channel by excavating soil along and close to the wall face ensuring uniform dispersal of the chemical emulsion to a depth of 300mm from the ground level by rodding with 12mm dia. MS rod at 150mm interval in the channel. 1.75 litres of chemical emulsion per metre length shall be used and a balance quantity of 0.5 litres of the chemical emulsion per running metre shall then be used to treat the backfill earth by directing the spray of the emulsion towards the wall surface. The entire work is to be carried out as per specification laid down in para 4.3.1.1 of code IS-6313 (Part-III)-1981. |
| 8 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 9 | Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. |
| 10 | Cement concrete with graded stone ballast (40 mm size excluding shuttering)N.B Variety(1:3:6) |
| 11 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 12 | Controlled Cement concrete with well graded stone chips (20 mm nominalsize) excluding shuttering and reinforcement with complete design of concreteas per IS : 456 and relevant special publications, submission of job mixformula after preliminary mix design after testing of concrete cubes as perdirection of Engineer-in charge. Consumption of cement will not be less than300 Kg of cement with Super plasticiser per cubic meter of controlledconcrete but actual consumption will be determined on the basis ofpreliminary test and job mix foumula. In ground floor and foundation.[usingconcrete mixture]M 25 Gradei) NB Variety |
| 13 | Controlled Cement concrete with well graded stone chips (20 mm nominalsize) excluding shuttering and reinforcement with complete design of concreteas per IS : 456 and relevant special publications, submission of job mixformula after preliminary mix design after testing of concrete cubes as perdirection of Engineer-in charge. Consumption of cement will not be less than300 Kg of cement with Super plasticiser per cubic meter of controlledconcrete but actual consumption will be determined on the basis ofpreliminary test and job mix foumula. In ground floor and foundation.[usingconcrete mixture]M 30 Gradei) NB Variety |
| 14 | Hire & labour charges for shuttering with centering and necessary staging upto 4M using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels, curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 15 | (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shutteringin any concrete work |
| 16 | Reinforcement for reinforced concrete work in the all sorts of dtructures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection complete as per drawing and direction. a) For works in Foundation and upto roof of ground floor / upto 4M |
| 17 | Brick work with 1st class bricks in cement mortar (1:6) |
| 18 | Brick work with 1st class bricks in cement mortar (1:4) b) In superstructure, ground floor |
| 19 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) inground floor. |
| 20 | Supplying, fitting and fixing Fan Hook for ceiling with 1 metre long 16mm dia. rod complete including mending damages. Payment for mending damages and repair to be made separately. |
| 21 | Supplying and laying true to line and level vitrified tiles of approved brand(size not less than 600mmX600mmX10mm thick)in floor,skirting etc. set in 20mm sand cement mortar (1:4) and 2mm thick cement slurry back side of tiles using cement @ 2.91kg/sq mtror using polymerised adhesive (6mm. thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg. of cement per sq.m. below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacture\"s specification and direction of Engineer-in-Charge.(White cement, synthetic adhesive and grout materials to be supplied by the contractor). a) Deep Colour & White |
| 22 | Supplying,fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4nos.of key stones (10 mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface,if necessary or by synthetic adhesive & grout materials etc.(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 kg/Sq.m & joint filling using white cement slurry @ 0.20 kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m (ii) Other than coloured decorative including white |
| 23 | Supplying fitting and fixing Marble Slab/tile of 15 to 18 mm. thickness in floor, lobby, stair, landing & treads etc. over 20 mm. (av.) thick base of Cement mortar (1:2) laid with white cement slurry @ 4.4 Kg/Sq.m. before placing marble & jointed with white cement slurry @ 2.0 Kg./Sq.m. with necessary pigments including grinding and Granite polishing as per direction of Engineering-in-Charge in Ground, 1st & 2nd Floor. (White cement and Pigment to be supplied by the Agency).b) With Chawk Dungri |
| 24 | Supplying, fitting & fixing granite slabs 15 mm. to 18 mm. thick with uniform texture & without decorative veins in columns, wall facia & floor etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging curing and roughrning of concrete surface complete.[Using cement slurry at back side of granite @ 4.4 Kg./sq.m. & white cement slurry for joint filling @ 1.8 Kg./sq.m.] |
| 25 | 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]i) In Ground Floor |
| 26 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.(Add extra @ 1.2 % for each additional floors upto 4th floor and @1.5% for each addl. Floor above 4th floor) In ground floor.Flash butt welded windows and ventilators (No shop priming will be allowed to facilitate inspection ofworkmanship) Without integrated grills. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] |
| 27 | Supplying, fitting & fixing Glass mosaic/bisazza tiles at finished plain wall & floor surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge. |
| 28 | Supplying and laying true to line and level Scratch resistant, Neutral to UV rays, Non-fade, High Slip Resistant Full Body Vitrified Tiles conforming to IS:15622-2006 & IS :4457- 2007 and tested in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance: 0.6, Mohr\"s hardness > 7.0, Staining resistance: Class-1, Water Absorption E < 0.5%], MOR > 38N/sq.mm & Breaking strength > 4000 N for Outdoor area of building e. g. Driveway, Pathway, Pavements, Parking lots, Sloping ramps, Entrance lobbies, Patios, Portico, swimming pool enclosure, Bus Passenger Shed & directing visually impaired persons, set over necessary underlay and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles and removal of wax coating of top surface of tiles with warm water and cleaning the tiles using soft and dry cloth complete including the cost of materials, labour and all other incidental charges complete including backside slurry but excluding the cost of underlay and true to the manufacturer\"s specification and direction of Engineer-in-Charge. In Ground Floor: Sizes-300 mm x 300 mm x15 mm |
| 29 | Anti slip finger grip tiles , size 250mm * 125mm. Make: morbi |
| 30 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. |
| 31 | Collapsible gate with 40 mm X 40 mm X 6 mm Tee as top and bottom guide rail, 20 mm X 10 mm X 2mm vertical channels 100 mm apart in fully stretched position. 20 mm X 5 mm MS flats as collapsible bracings properly rivetted and washered including 38 mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. |
| 32 | Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge.Weight of Strainless Steel railing per metre 6.5 Kg (approx) |
| 33 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete, iron butt hinges and M.S. clamps. (d) Sal: Local |
| 34 | M.S. clamp for fixing door and window frame made of flat bent bar, end bifurcated, fixed in cement concrete with stone chips (4:2:1) fitted and fixed complete as per direction(c) 40mm x 6mm, 125mm length |
| 35 | Door stopper (Brass) |
| 36 | Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S.specification (I.S.205/66) and fitted and fixed with cadmium plated screws : (iv) 75 x 63 x 3.2mm. |
| 37 | Anodised aluminium D-type handle of approved quality manufactured from extruded section conforming to IS. specification (I.S.230/72) fitted & fixed with complete(a) With continuous plate base hexagonal/round rod)(vii) 150mm grip x 12mm.dia rod |
| 38 | (b) Supplying \"Godrej\" mortice lock chromium plated with keys 6 levers including fitting & fixing complete. |
| 39 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35 mm thick shutters (single leaf) |
| 40 | Supplying, fitting and fixing fibre reinforced polymer (FRP) composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to inpart monolitaheic composite structure as per approved technology of department of science and technology (DST) to satisfy IS:4020 door testing performance criteria in ground floor.i) 32mm thick |
| 41 | Supplying, fitting and fixingfibre reinforced polymer (FRP) composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to inpart monolitaheic composite structure as per approved technology of department of science and technology (DST) to satisfy IS:4020 door testing performance criteria i) 66mm x 90 mm |
| 42 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (x) 300mm long x 12mm dia. bolt. |
| 43 | i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.(c) 300mm long. |
| 44 | i) Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete.(b) Medium (I.S.I. size 2) |
| 45 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface, including throating, nosing and drip course where necessary. (ii) With 1:4 cement mortari) Ground floora)15 mm. thick plaster (External & internal) |
| 46 | (iii) With 1:3 cement mortar(c) 10 mm. thick plaster (Ceiling,etc.) |
| 47 | Making V-groove line ( 12 mm wide, 12 mm deep ) in plastered |
| 48 | Neat cement punning about 1.5 mm thick wall , dado, window, sills, floor, drain etc. NOTE: Cement 0.152 cu.m. per 100sq.m. |
| 49 | Applying interior grade acrylic primer of approved quality & brand on plastered or concrete surface old or new surface to receive distemper / acrylic imulsion paint including scraping & preparing the surface thoroughly , complete as per munufacturers specification & as per direction of the EIC.(I) Internal surface (all floors)(a) one coats (on new work only)(i) water based interior grade acrylic primer. |
| 50 | Applying exterior grade acrylic primer of approved quality & brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finished acrylic exterior emulsion paint including scraping & preparing the surface thoroughly , complete as per munufacturers specification & as per direction of the EIC.(iii) Two coats. |
| 51 | Protective & decorative acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required.The rate includes cost of material , labour,scaffolding and all incidental charges but excluding the cost of primer.(iii) Two coats. b) Premium 100% Acrylic Emulsion |
| 52 | Applying acrylic emulsion paint of approved make and brand on walls and ceilling including sand papering in intermediate course including putty ( to be done under specific instruction of SE)Two coats i) Standard quality |
| 53 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) |
| 54 | b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 55 | a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 56 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc.on the surface of necessary.(a) On timber or plastered surface:With other than hi-gloss of approved quality (iv) Two coats (with any shade except white) |
| 57 | (b) On steel or other metal surface : With other than hi-gloss of approved quality (iv) Two coats (with any shade except white) |
| 58 | Supplying, fitting & fixing UPVC pipes A - type and fittings conforming to IS: 13592 -1992 with all necessary clamps nails including making holes in walls, floor etc. and cutting trenches in any soil through masonry concrete structures etc. if necessary and mending good damages including jointing with jointing materials (Spun yarn, valamoid / bitumen / M. seal etc.) complete. A) UPVC Pipes:(iii) 160 mm dia. |
| 59 | B) UPVC Fittings:c) Bend 87.5 degree(iii) 160 mm Dia. |
| 60 | d) Shoe(iii) 160 mm Dia. |
| 61 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285-1975; Annodized (with required film thickness and specified colour/natural) matt finished conforming to IS: 1868-1983 for fabrication of , slidingwindows, formed of basic sections of any ISI embossed/certified make and brand as per direction of Engineer-in-Charge.(Payment will be made on finished length of the work).15 Micron colour annodizing2-track sliding windowi) Bottom frame |
| 62 | ii)Top and side frame |
| 63 | Louvered windowi) Top, bottom and side member |
| 64 | ii) Louvered Section |
| 65 | iii) Cleat angle (Non-annodized) |
| 66 | Shutter for all track sliding windowi) Bottom & Top member |
| 67 | ii)Style side member |
| 68 | iii) Interlock member |
| 69 | Labour charge for fabrication and installation of window made from annodized extruded alloy aluminium sections for the following units:- A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sections, fabrication, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (wall, column, beam, lintel etc.) as well as between glass and shutter frame for fixing glass and Poly Shulphate sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass all complete.(The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle 4mm. glass etc. but excluded the cost of extruded aluminuum section, neoprene/EPDM gasketing, locking arrangement and rollers.a) 2-track sliding window. |
| 70 | b) Louvered window |
| 71 | Supplying maruti lock ( 100 mm ) |
| 72 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.ii) 4mm thick coloured/tinted/ smoke glass |
| 73 | Supplying PVC rollers for sliding windows as per direction of Engineerin charge. |
| 74 | Supplying EPDM gusket of approved make and brand as per direction ofEngineer in charge i) For sliding windowsb) \"U\" shaped EPDM gasket for frames. |
| 75 | Providing waterproofing treatment over concrete roof surface (old or new) by the application of two coats of slurry prepared with latex of approved brand, water and cement in the proportion of (LP.W. Cement - 1:4:6) by volume, with brush in a time gap of minimum 4(four) hours to 14(fourteen) hours between the two layers, laying 20mm thick and sand and cement consolidated plaster (1:4) admixed with Plastocrete Super of approved brand 0.2% by weight of cement, laying flat 1st class Brick Bats / Bricks over the mortar keeping a gap of 10-20 mm between two bats, filling the vertical joints with the aforesaid mortar, providing a second layer of 20 mm thick sand and cement plaster (1:4) admixed with Plastocrete Super as above over the brick layer, the top surface of the treatment should be chequered toprovide the antistrip property.(Note - the applicator is to be specialised in such type of work as per specification and maintain the I.S.I. Marked of the ingredients of the application. The skilled worker such as Head Mason, Mason, Bhistri, Majdoor should be trained from expert and recognised technical Personal/Institution having affiliated ISO-9001) |
| 76 | Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling]Red Variety(ii) 30 mm. thick |
| 77 | Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidatingthe same by ramming and dressing complete. (Payment will be made on profile measurement before and after the work)ii) With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km. including the cost of carried earth. |
| 78 | (a) Ladder 6 Step- Supply, erection, testing and commissioning of Overflow ladder 6 step having step dimensions 500 mm x 75 mm thick, Type of step - Non- Slip step , Hand rail dia - 42 mm pipe, Steps - Stainless steel, Material of construction - AISI -304 , Centre to centre of steps - 250 MM, Type of fixing - Wall support fixing. including all accessories,fitting, fixing. (Make : Candy) |
| 79 | Ladder 8 Step-Delivery, supply, erection, testing and commissioning ofOverflow ladder 8 step without welded joints and treads having step dimensions 500 mm x 75 mm thick, Type of step - Non- Slip step , Hand rail dia - 43 mm pipe, Steps - Stainless steel, Material of construction - AISI -304 , Centre to centre of steps - 250 MM, Type of fixing - Wall support fixing, Accessories - Fixing anchors and electrical earthing connection including all accessories, fitting, fixing, all Taxes & T&P required for the work complete as per direction ofConsultant. (Make : Candy) |
| 80 | (c) Grating. Delivery, supply, erection, testing and commissioning of Modular type Grating having grating width - 350 mm, Height - 24 mm, Material of Construction -UV Stailized Polypropylene including all accessories, fitting, fixing, all Taxes & T&P required for the work complete as per direction of Consultant. (Make : Candy) |
| 81 | b) Pumping out water from ponds or tanks(Payment if permitted will be made on the quantity of water calculated on the basis of initial water level and final level on consideration being made for any water that may have been added through percolation or otherwise) |
| 82 | PRESSURE SAND FILTER. Delivery, supply, erection testing and commissioning of Pressure Sand Filter with dia meter - 2700 mm x 1050 HOS, Shell Thickness 8mm , Dish Thickness 10mm, Filter Nozzle Plate Thickness 10 mm, Material of construction MS Fabricated, Flow/unit - 164.06m3/hour, Velocity /Filteration rate - 28.68 m3/hour/m2, Maximum working pressure - 4 Kg/Cm2 , Type of filtering media - Silika Sand, Size of filter media - 8/16 & 16/32 mesh, Quanty of filtering media per unit 6600 Kgs, Type of Inlet distributor - Nozzle Plate fitted with Filter Nozzles, sampling arrangement including fixing, all Taxes & T & P required for the work complete as per direction of Consultant. (Make : CANDY) |
| 83 | Frontal Piping Supply, erection, testing and commissioning of Piping and Valves For Filter Type of Piping and pipe fitting - MS \"B\" class; Type of Valves: CI Butterfly Valve Size of valves - 150 mm for Inlet, out let, washout, upwash - 100 mm drain and 65 mm for air release for Filter including all accessories, fitting (Make : Pipe - Jindal or equ. Valves -Sir/Zoloto) |
| 84 | i) DOSING SYSTEM-PH ADJUSTMENT DOSING SYSTEM. (SODA ASH/HCL) (a) Pump and MS Stand Supply, erection, testing and commissioning Dosing Pump, Pump having capacity 0-15.5 Liters/hour, Flow adjustment - By adjusting stroke length from 0 -100% manually, Power rating - 230 V 50 Hz, MS Stand, Material of construction - MS Fabricated -including all accessories, fitting , fixing (Make : Pump - Toshcon, MS Stand - Candy) |
| 85 | CHLORINE DOSING SYSTEM - (a) Pump and MS StandSupply, erection, testing and commissioning Pump, Pump having capacity 0-90Liters/hour, Flow adjustment - By adjusting stroke length from 0 -100% manually, Power rating - 230 V 50 Hz, MS Stand, Material of construction - MS Fabricated -including all accessories, fitting , fixing (Make : Pump - Toshcon, MS Stand - Candy) |
| 86 | (e) Float Line Roller. Supply, erection, testing and commissioning of Float line Roller having Material of Construction - Stainless steel SS - 304 with two wheels, Capacity - 5 float lines each including all accessories, fitting, fixing. (Make : Candy) |
| 87 | Life Guard Chair -Delivery, supply, erection, testing and commissioning ofLife Guard Chair, Material of construction - AISI -304,including all accessories, fitting, fixing.(Make : Candy) |
| 88 | Life Buoy make: Wuxi |
| 89 | Life Jacket make: Markwel |
| 90 | S&PWorksSupply fitting & fixing Peet\"s valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fitting (tseted to 21 Kg per Sq. cm.)vi) 32 mm |
| 91 | vii) 25 mm |
| 92 | Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (vi) 32 mm dia |
| 93 | Supplying, fitting & fixing bib cock or stop cock.b) (ii) Chromium plated Concealed Stop Cock(Equivalent to Code No. 514(A) & Model‐ Tropical / Sumthing Special of ESSCO or similar brand) |
| 94 | c) (ii) Chromium plated Bib Cock with wall flange (Equivalentto Code No. 5047 & Model‐ Florentine of Jaquar or similarbrand) |
| 95 | Supplying, fitting and fixing shower of approved brand and make.(ii) Chromium plated round shower with revolving joint (Equivalent to Code No. 541(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 96 | (b) Chromium plated Rose shower with revolving joint and 150 mm long shower arm (Equivalent to Code No. 5489 & Model - Florentine of Jaquar or similar brand). |
| 97 | (d) Chromium plated Hand shower with Flexible Tube & fittings(Equivalent to Code No. Hsh-1937 & (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar).). |
| 98 | (f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar). |
| 99 | Supplying, fitting & fixing C.I. holder bat clamp including cutting holes in wall etc. & mending good all damges in cement concrete with jhama chips (1:2:4) & cement plaster (1:6) to match & curing complete in all respect.iii) 25 mm |
| 100 | iv) 32 mm |
| 101 | Supplying, fitting & fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD ‐ 1785 & threaded to match with GI Pipes as per IS : 1239 (Part ‐ I). With all necessary accessories, specials viz. socket, reducing tee, short piece etc. fitted with holderbatsclamps, including cutting pipes, maing threads, fitting,fixing etc. complete in all respect including cost of all coats of painting with approved paint in any positionabove ground.(Payment will be made on the centre line measurments of total pipe line including all specials. No separate payment will be made for assesories, specials. Payment for painting will be made seperately)a) For Exposed WorkPVC Pipes (Dia)25 mm |
| 102 | 32 mm |
| 103 | b) For Concealed Work15 mm |
| 104 | 20 mm |
| 105 | 25 mm |
| 106 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.(a) For Exposed Work(i) CPVC Pipes Class-I,SDR-11(Dia)25mm |
| 107 | 40mm |
| 108 | Supplying, fitting & fixing PVC pipes for underground work of approved make of medium duty) conforming to ASTMD ‐ 1785 & threaded to match with GI Pipes as per IS : 1239 (Part ‐ I). With all necessary accessories, specials viz. socket, bend, tee, union, coss, elbo, nipple, lomgscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials, jointing materials, cutting pipes, making thread, cutting trenches upto 1.5 metrebelow suffacein all sorts of soil & refilling the same directed complete in all respect. (Payment will be made on the centre line measurments of the total pipe line including all specials. No separate payment will be made for assesories, specials)PVC Pipes (Dia)32 mm |
| 109 | 40 mm |
| 110 | 50 mm |
| 111 | Supply , Fitting & Fixing of complete Bottle waste tap. i)32 mm |
| 112 | Supplying, Fitting, Fixing 10 litre P.V.C. low‐down cistren conforming to I.S. specification with P.V.C. fitting complete, C.I. brackets including two coats of painting to bracket etc. |
| 113 | Supplying P.V.C. water storage tankof approved quality with closed top with lid (Black) ‐Multilayerh) 2000litre capacity |
| 114 | Labour for punching hole in plasticwater storage tank upto 50 mm dia. |
| 115 | Labour for hosting plastic storage tank.ii) Above 1500 litre upto 5000 litre capacitya) Upto 1st story from GL. |
| 116 | b) Extra for each additional floor. |
| 117 | Supplying, fitting & fixing white vitreous china best quality approved make wash basin with C.I. brakets on 75mm x 75mm wooden blocks, C.P. waste fitting of 32 mm dia, one approved quality brass c.p. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quailty P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damges & painting thebrackets with two coats of approved paint.ii) 550 mm x 400 mm size |
| 118 | Supplying, fitting & fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.iii) 600 mm lomg |
| 119 | iv) 750 mm long |
| 120 | Supplying, fitting & fixing approved brand 32 mm dia. P.V.C. waste pipe, with P.V.C.. Coupling at one end fitted with necessary clamps.ii)750 mm long |
| 121 | Supplying, fitting & fixing pillar cock approved make c) CP Pillar Cock - 15 mm. (Code No. 5011 & Model - FLORENTINE of JAQUAR or equivalent). |
| 122 | e) (ii) CP Wall Mixture without spout but with provision for connnection to Telephone Shower and exposed pipe for Overhead shower (Equivalent to Code No. 5215 & Model - FLORENTINE of JAQUAR or similar brand). |
| 123 | (g) CP Sink Cock with Regular Swinging Spout (Table Mounted Model) (Equivalent to Code No. 5357 of JAQUAR or similar brand). |
| 124 | Supply of UPVC pipes (B type) & fittings conforming to IS‐13592‐1992(A) Pipes(i) Single socketed 3 Metre Lengthb) 110 mm |
| 125 | (iii) Single socketed 1.8 Metre Lengthb) 110 mm |
| 126 | (B)Fittings(i) Couplerb) 110 mm |
| 127 | v) Plain Yb) 110 mm |
| 128 | ix) Bend 45 degreeb) 110 mm |
| 129 | x) Bend 87.5 Degreeb) 110 mm |
| 130 | xi) Door bend (T.S.)b) 110 mm |
| 131 | xxi) 110 x110 \"P\" Trap75 mm |
| 132 | Labour for fitting & fixing U.P.V.C. pipes for above ground work including cost of joining materials etc. fitting & fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary & mending good all damages excluding the cost of masonary or concrete work, if necessary, but including the cost & fitting & fixing holder bat clamps (any floor) or for underground workincluding cutting trenches upto 1.5 meter & refilling the same complete as per direction of Engineer‐in‐charge. (Payment will be made on centre line measurment of the total pipeline includings specials)A) Above ground(ii) 110 mm dia. Metre |
| 133 | B) Under ground(ii) 110 mm dia. |
| 134 | Supplying, fitting & fixing E.W.C. in white glazed vitreous chainaware of approved make complete in position with necessary bolts, nuts etc.a) With \"P\" trap |
| 135 | Supplying, fitting & fixing 32 mm dia. Flush Pipe of approved make with nexessary fixing materials & clamps complete. i) Polythene Flush Pipe |
| 136 | Supplying, fitting & fixing liquidsoap container c) Fibre glass |
| 137 | Supplying, fitting & fixing soap holderb) Fibre glass |
| 138 | Supplying, fitting & fixing best quality Indian make mirror 5.5 mm thick with silvering as perI.S.I. specification suppoerted on fibre glass frame of any colour, frame size 550 mm x 400 mm |
| 139 | Supplying, fitting & fixing towel rail with two brackets.(b) Aluminiumiii) 25 mm dia. & 750 mm long |
| 140 | Supplying, fiiting & fixing Flat back urinal (half stall urinal) in white vitreous chainaware of approved make in position with brass screws on 75mm x 75mm x 75mm wooden blocks complete(ii) 470 mm X 280 mm X 340 mm |
| 141 | Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately).(i) 450 mm X 350 mm |
| 142 | Constructing inspection pit of inside measurment 600mm x 600mm x upto 600mm (depth) with 250mm thick 1st. class brick work in mortar (1:4) on sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over layer of jhama brick flat soling, 15 mm thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips & necessary reinforcement upto 1% & shuttering including 6mm thick cement plastering (1:4) in all external surfaces of the slab & one 560 mm dia R.C.C. mahole cover approved make supplied, fitted & fixing in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth & removing spoils after work complete in all respect with all costs of labour & materials.ii) With Pakur Variety) (SAIL/TATA/RINL) |
| 143 | Construction of septic tank of different capacities as per approved drawing with 1st. class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. mahole cover (heavy type) of approved make supplied, fitted & fixed in the 100 mm thick R.C.C. (1:1.5:3) top slab with necessary fittings, 20 mm thick cement plaster (1:4) with neatcement finish to the internal surface & 15 mm thick plaster (1:4) to outside wall upto 200 mm below G.L. floor finished with 25 mm thick grey artifical stone over 100 mm thick R.C.C. (1:1.5:3) bottom slab including supplying, fitting & fixing all necessary specials, fittings, S.W. tees, C.I. foots rest etc. including excavation earth in all sorts of soil, shoring, bailing out & pumping out water as necessary, raming, dressing the bed & refilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foregin materials from the chamber & including constucting attached inspection pit as per approved drawing & connecting all necessary pipes, joints etc. with internal plaster work & artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour & materials i) For 30 usersB) With Bazree (N.B Varity) (Other than SAIL/TATA/RINL) |
| 144 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round & cement brick work (1:4) upto 0.90 metre from the top with 20 mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15 mm thick cement plater (1:4) on outer face from top of the well upto G.L. & 6 mm thick cement plastering (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of well with brick metal (50 mm to 63 mm size) stone chips with necessary reinforcement & shuttering including one 560 mm dia R.C.C. manhole cover (heavy type) of approved making supplied, fitting & fixed in cover slab with necessary fittings, making necessary arrangements for pipe conections, excavation of well including shoring, dewatering & removing the exess eath from the premises as per direction complete in all repect with all costs of labour & materials. With 250 mm thick dry brick work & 250 mm thick cement brick work (1:6) & 1.00 mm inside dia. |
| 145 | Supplying, fitting and fixing with cement jointing (3:1) salt glazed stonewared pipe including excavation of earth upto 1.50 metre depth in all sorts of soil both mixed or unmixed and refilling (but excluding concreting at bottom and sides.)(ii) 225 mm |
| 146 | Cement Concrete with graded jhama khoa (30 mm. size) excluding shuttering In ground floor and foundationa)1:3:6 proportion |
| 147 | PUDDLE FLANGES Supply and installation of PVC Puddle Flanges & Sleeves of appropriate size and FRP Wielded Plate . 250 mm dia |
| 148 | Providing and fixing CI Butterfly valves including necessary nuts, bolts, gaskets etc. complete.250 mm dia Make: Sir/Zoloto |
| 149 | PUDDLE FLANGES Supply and installation of PVC Puddle Flanges & Sleeves of appropriate size and FRP Wielded Plate . 50 mm dia |
| 150 | PUDDLE FLANGES Supply and installation of PVC Puddle Flanges & Sleeves of appropriate size and FRP Wielded Plate . 25 mm dia |
| 151 | Sluice Valve, Supply, testing and commissioning of 250mm Sluice Valve with extension Spindle for Swimming Pool Drain (Make : SIR) |
| 152 | PLUMBINGProviding and fixingPVC pipes complete with UPVC Fittings i.e, tees, elbows, sockets, necessory clamps / support etc the sameas per instructions of Engineer-in-charge. Make : Price/Finolex/Supreme . 160 mm dia (10 kg) |
| 153 | PLUMBINGProviding and fixingPVC pipes complete with UPVC Fittings i.e, tees, elbows, sockets, necessory clamps / support etc the sameas per instructions of Engineer-in-charge. Make : Price/Finolex/Supreme . 110 mm dia (10 kg) |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail