| 1 | Supply, installation, testing & Commissioning ofonline, double conversion IGBT based technology UPS of capacity 60 KVA with 3 phase AC input 300 to 450V and 3 phase AC output 415 ± 1%, 50 Hz, pure sine wave with inbuilt isolation transformer along with suitable number of SMF batteries as per OEM recommendation for minimum 30 mins back up, the AH capacity of each battery shall not be less than 130 AH complete all as specified and as directed.Make: KRYKARD/ Microtek/ LuminousNote: (i) The quoted rate is inclusive of Batteries, inter connecting copper cables along with copper lugs for batteries.(ii) Manufacturer type test certificates/ test reports for equipments shall be submitted by contractor before claiming payment.(iii) The quoted rate deemed to be inclusive of service visit once in three months during defect liability period. Contractor shall submit undertaking on Rs 100 non-judicial stamp paper.(iv) The contractor shall submit technical specification & GA drawings for approval of GE before placing order.(v) The testing of UPS shall be carried out by rep nominated by Accepting Officer.(vi) Battery rack/ structural steel shall be measured and paid seperately under relevant item. |
| 2 | M&L for sub main wiring with 4 runs of 25 Sqmm single core, PVC insulated, PVC innersheathed, unarmoured 1100 Volts grade, multi-stranded, copper conductor cables (FRLSH quality) drawn through PVC casing capping/ conduit/ flexible pipe as per site site requirement with fitting/accessories, fixed on, walls, ceiling etc. as required including 25 Sqmm PVC insulated, unsheathed, multistranded, copper conductor, single core cable as earth continuity wire complete as specified and directed.(i) Four runs of cables, one run of earth wire and one run of rigid PVC conduit shall be measured as one run length.(ii) The quoted rate is deemed to be inclusive of necessary copper lugs for termination of cable. |
| 3 | Supply, installation, testing & commissioning of 4P, 415 volts, 50 Hz, 125 Amps motorised automatic transfer switch with controller, enclosure made up of sheet metal/ polycarbonate body with minimum IP 40 protection having provision for selection of manual and auto mode operation including, protection against over voltage/ under voltage, phase sequence, single phasing taking down defective switch complete all as specified and as directed.Note: The quoted rate shall be deemed to be inclusive of necessary supporting angle iron frame work as specified by Engineer-in-Charge for mounting transfer switch without any wall support. |
| 4 | Supply and fixing 6 way vertical type of MCCB TPN DB, double door, IP-43, IK-09, suitable for flush mounting type, powder painted with suitable capacity copper bus bar for each phase, neutral link, earth bar and Din rail ,415 Volts complete all as specified and as directed . |
| 5 | Supply and fix MCCB 125 Amps, TPN/4 pole, 415 volt, breaking capacity 16 KA Thermal magnetic type, suitable for fixing in VTPN DB complete all as specified and as directed by Engineer-in-Charge.Note :(i) MCCB should be Ics = 100 % Icu (ii) MCCB should be adjustable O/L (0.8-1)In andS/C - (5-10)ln |
| 6 | Supply & fixing MCB TP415 Volts, \"C\" series, breaking capacity 10 KA of rating25 to 63 Amps complete all as specified and as directed. |
| 7 | Supply and fix sheet metal enclosure of thickness not less than 1.6 mm with, 2 pole DC MCCB of rating 320 Amps, thermal magnetic type complete all as specified and as directed. |
| 8 | M & L for sub-main wiring with 10 Sq.mm (nominal area) PVC unsheathed multi strandard copper conductor PVC insulated 1100 volt grade4 runs of single core cable drawn through and including rigid PVC conduit medium grade minimum 25 mm size / casing capping as per site requirement and its accessories complete along with one single core PVC insulated unsheathed multistranded copper conductor cable green colour of size 10 Sqmm as continuous earthing wire and connecting to common earth dolly completely concealed in walls/ceiling/roofs all as directed and specified. Note : Five runs of PVC copper cable and one run of PVC conduit will be measured as one RM. |
| 9 | M & L for XLPE insulated, PVC innersheathed, unarmoured, 25 Sqmm single core multistrand 1100 volts grade copper conductor (FRLSH quality) cable drawn through and including PVC conduit medium grade minimum 20 mm size and its accessories for fixing on wall complete all as specified and as directed. |
| 10 | M & L for XLPE Insulated, 35 Sqmm single core, PVC Innersheathed, Unarmoured, multistrand 1100 volts grade aluminium conductor cable drawn through and including PVC conduit medium grade minimum 25 mm size and its accessories for fixing on wall complete all as specified and as directed. |
| 11 | Material and labour earthing with copper plate 60cm × 60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead, buried directly in ground to a depth not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to20×3mm copper strip as earthing lead by means of nuts, bolts and washers of steel after welding of copper strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified orindicatedincludingtesting on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe,Copper earth strip upto 7.5 m long for connecting totest point etc. all as required at site for complete earthing. |
| 12 | M & L for earthing with steelearth plate electrode ofsize 60cm x 60cm x 6mm thick buried directly in ground to a depth not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 , adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified orindicatedincludingtesting on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting totest point etc. all as required at site for complete earthing. |
| 13 | Supply & fixing IP 65 / 66thermoplastic-polycarbonate cable junction box of size 155X210X92which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on surface / framewith the helpofrequired size / self drill screw complete all as specified and as directed by Engineer-in -charge. |
| 14 | Supply, fabricate and fix cross arms any size along with, brackets, clamps, bolts, nuts, washers, bracers etc including drilling holes, cold/hot complete to accommodate UPS batteries, including one primer coat and one under and finishing coat of paint complete all as specified and as directed by Engineer in Charge. |
| 15 | M&L point wiring with 1.5 Sqmm (nominal area) PVC unsheathed multi stranded copper conductor pvc insulated 1100 volt FRLS grade multi stranded cable drawn through and including PVC casing caping/conduitISI marked minimum 20mm size and its accessories complete along with 1.5 Sqmm cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed ,surface, in walls/ceiling/roofs with and including 1.2 mm thick MS sheet terminal boxes duly fabricated flush mounting in the wall for mounting switches, switch socket combinations fan regulators etc., as required with 3 mm thick plastic laminated sheet top cover complete all as directed and specified |
| 16 | All as per item No 15.00 herein before but with 2.5 Sqmm single coremulti standard unsheathed copper conductor for one three pin socket 16 Amps on independant board including continuous earth wire PVC insulated 2.5 Sqmm copper solid conductor to common earth dolly complete. |
| 17 | All as per item No 15.00 herein before but with 4 Sqmm single core multi standard copper conductor for one three pin socket 15 Amps on independent board/metal clad socket for charging point including continuous earth wire PVC insulated 4 Sqmm copper solid conductor to common earth dolly. |
| 18 | supply and fixing modular switch 1 way 16A, 220V 50Hz1 module as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 19 | supply and fixing modular switch 1 way 6A, 220V 50Hz 1 module as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 20 | supply and fixing modular Socket, 16A - 2/3 pin combined ,220V 50Hz2 module as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 21 | S&F ceiling rose, surface bakelite 65 mm x 30 mm, 3 terminals complete all as specified and directed |
| 22 | M&L for Sub main wiring complete with 2 x 1.5 sqmm, single core, multi stranded copper conductor FRLS PVC insulated and sheathed cable 1100 volts grade, drawn in 25mm PVC casing caping in surface/PVC conduit on surface (as required) along walls roofs etc including 1.5 sqmmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly completeall as specified and directed. |
| 23 | M&L for Sub main wiring complete with 2 x 2.5 sqmm, single core, multi stranded copper conductor FRLS PVC insulated and sheathed cable 1100 volts grade, drawn in 25mm PVC casing caping in surface/PVC conduit on surface (as required) along walls roofs etc including 2.5 sqmmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly completeall as specified and directed. |
| 24 | M&L for Sub main wiring complete with 2 x 4 sqmm, single core, multi stranded copper conductor FRLS PVC insulated and sheathed cable 1100 volts grade, drawn in 25mm PVC casing caping in surface/PVC conduit on surface (as required) along walls roofs etc including 4 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly completeall as specified and directed at site.Note:(i)All three wire/cable (phase, neutral and earth) should be run through for each individual circuit from the DBs.(ii) Two run/four runs of cable and one run/two runs of earth conductor and PVC Conduit/Casing Caping be measured as one length. |
| 25 | Supply and fixing 240V, 10 KA \"C\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, complete with connection testing and commissioning all as directed by Engineer-in-Charge.Make: Havells/L&T/Legrand |
| 26 | Supply and fixing DP RCBO 30 mA 40 Amps SPN complete all as specified and dirested by Engr-in-charge.Make: Havells/L&T/Legrand |
| 27 | S&F DB SPN 8 waywith category of protection double door type IP-42 factory made with tinned copper 200 Amps rated bus bar suitable for MCBs,all as specified and directed. Note : SPN distribution board shall be fixed in the wall such that front cover shall be seen flush with the wall surface .Make: Havells/L&T/Legrand |
| 28 | Supply and fixing toughened glass round highay LED light of 100 W in PDC housing suitable for industrial application.The luminaire has efficiancy upto 125 lm/W, 10KV SPD and ingress protection of IP66 with additional safety chain all as specified and directed by Engineer in charge.Make: Phillips /Crompton/Havells |
| 29 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. all as specified directed. Make: Phillips /Crompton/Havells or equivalet. |
| 30 | M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth strip 25x4mmconnected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I.Note: (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item(ii) The unit rate shall also includes for Wire mesh, funnel, excavation, PCC chamber pit and test point complete.(iii) Cost of PVC insulated unsheathed copper cable of size 10 sqmm with suitable size of PVC conduit from test point to incomer DB of bldg shall be deemed to be included in the rate quoted for this item. |
| 31 | Supply, lay, testing and commissioning UG cable XLPE insulated, armored heavy duty electric cable of size 10 sqmm 4 core, 1100 volts grade with stranded aluminium conductor in trenches including suitable size of double grip cable gland and joiinting etc complete for the following sizes :-Make:Polycab/Havells/KEI |
| 32 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Phillips /Crompton/Havells |
| 33 | Supply, laying of Telerex DWC (double Wall corrugated) HDPE pipe ISI marked of outer dia of 40 mm and inner dia 32 mm polethylene including couplers, bends, cap etc.,with smooth internal and profiled external surface for non pressure under ground cable complete all as secified.Make Rex Polyextrusion Ltd or equivalent. |
| 34 | Supply and fix ofexhaust fan, steel body AC single Phase. 230V of size 380m sweep with, blades, frame and louvers, including cutting of galvalume sheet to the size of Exhaust fan frame, including provision for mounting of exhaust fan by using angle iron, nuts and bolts all as specified and directed.Make: Phillips /Crompton/Havells |
| 35 | S & FFe410 W (Gde E-250) quality A for chamber ,RCC tank and heavy bracket framing ( Beam,tee, angle channel or flat section) including distance pieces, clests etc. |