| 1 | Sub Head- I (EI & Fans and Pump Sets)Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(a) Group C |
| 2 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required.(a) Group C |
| 3 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel / PVC conduit as required. |
| 4 | 3 X 1.5 sq.mm |
| 5 | 3 X 4 sq.mm. |
| 6 | 3 X 6 sq.mm |
| 7 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 8 | 5/6 A Switch |
| 9 | 3 Pin 5/6 A Socket Outlet |
| 10 | 15/16 A Switch |
| 11 | 6 Pin 15/16 A Socket Outlet |
| 12 | 5/6 Amp Plug top |
| 13 | 15/16 Amp Plug top |
| 14 | Replacementof Surface/Wall Mounted 1 X 20W to 22W LED Tube With4 feet MS Batten Fitting, LED Tube should have extruded aluminium housing for efficient heat dissipation. Total system Lumen of 22W Led should be 1700 or above in Cool day Light(5700K to 6500K), Power factor>0.90, CRI>80. Complete with Mounting Brackets & accessories as required with connections etc. complete as reqd. |
| 15 | Replacement of recess type 34W to 36W Full window glarefree opal Diffuser LED Panel of size 595X595mm suitable for Armstrong/POP/GB ceiling with MS Powder coated White Housing. Total system Lumen of 34W to 36W LED should be 3300 or above in Cool day Light(5600K to 6500K), Power factor>0.95, CRI (Ra) >80, Complete with all accessories as required etc, complete as reqd. |
| 16 | Replacement of wall mounted cabin fan 450 mm sweep suitable for operating on 230 volt single phase AC supply i/c connection with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable earth etc as reqd. |
| 17 | S/I/T/C of 15 Watt LED surface mounted round shaped LED downlighter with durable housing with al. heat sink with diffuser to give glare free light with removable driver i/c connection with all accessories etc. complete as required |
| 18 | Supplying , Installation, testing and commissioning of 80Watt TURBO LED Flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminum extrusion with IP66 i/c connection with all accessories etc. complete as required. |
| 19 | S/I/T/C of weatherproof box made out of hot moulded SMC sheet with clamp, neutral link, strip, gland, thimble and 1 No. 10 Amps. SP MCB complete with inter connection, earthing etc as reqd.(Box Size: 280mm X 170mm X 114mm) |
| 20 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required |
| 21 | Operation and maintenance of water supply pump set installed at Udyog Sadan Quatab institutional area 8:00A.M to 4:00P.M (excluding Sunday & Holidays) as well as carrying out other associated E & M work, day to day electrical maintenance work of all electrical installation, DB’s, SD’s etc. i/c cleaning of pump, pump rooms and its surroundings etc. complete as required.(a) Wireman cum Pump Operator – 1 No. |
| 22 | (b) Wireman - 1 No. |
| 23 | Replacement of 5 HP22 stage 3 phase 415 volts Submersible pump set ,capacity – 3000 Lph. , Head – 84 Mt. in the existing bore well with help of chain pulley block tripod i/c credit of old dismantle material etc.complete as reqd. |
| 24 | Replacement of Submersible Pump Controller for 5 H.P capacity in Sheet Enclosure type MU-G (motor rating AC-3 Duty, 415Volt, 50 Hz,3 Phase i/c connection , testing i/c credit of old dismantle material etc.complete as reqd. |
| 25 | Supplying and Fixing 3 core 4 sq mm PVC insulated PVC sheathed flat cable copper conductor for submersible Motor complete i/c credit of old dismantle material etc as reqd. |
| 26 | Supplying and Fixing lowering of following size of G.I. pipe, medium class i/c providing & fixing 6mm thick G.I. flange duly welded on both ends of the pipe at 3mtr interval complete with rubber packing , nuts and bolts for making water tight connections i/c credit of old dismantle material etc as reqd. |
| 27 | 50mm dia |
| 28 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 29 | Supplying , Laying and fixing following size of PVC insulated and PVC sheathed al. conductor armoured power cable of 1.1 KV grade of following ways as reqd. (a) 3 X 10 sq.mm. cableon surface |
| 30 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 31 | 3 X 10 sq. mm (22mm) |
| 32 | Sub Head - II (Credit of Dismantle material)Less Credit of following Old dismantle materials as and where basis etc. complete as required. |
| 33 | Assorted Copper wire |
| 34 | Batten Fitting |
| 35 | Flood Light Fitting |
| 36 | Downlighter |
| 37 | Recess Fitting 2x2 Fitting |
| 38 | Wall Mounted cabin fan |
| 39 | Worn out Switch / Socket |
| 40 | Ceiling fan |