Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-05-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-05-2025 |
| Sl. No. | Item Description |
| 1 | Surface excavation n.exc 30cm deep and averaging 15 cm deep and getting out in soft/loose soil , complete all as specified and directed by Engineer-in-Charge. |
| 2 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in soft/ loose soil, complete all as specified and directed by Engineer-in-Charge. |
| 3 | Material and labour for plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge. |
| 4 | Material and labour for brick work with flyash bricks class designation 75 old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 , complete all as specified and directed by Engineer-in-Charge. |
| 5 | Material and labour for brick work with flyash bricks class designation 75 old size bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 , complete all as specified and directed by Engineer-in-Charge. |
| 6 | Material and labour for reinforced cement concrete M-25 (Design Mix) 20mm graded aggregate in foundations including rafts, footings,, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles, complete all as specified and directed by Engineer-in-Charge. |
| 7 | Material and labour for reinforced cement concrete M-25 (Design Mix) 20mm graded aggregate in columns, pillars, piers, posts & struts , complete all as specified and directed by Engineer-in-Charge. |
| 8 | Material and labour for reinforced cement concrete M-25 (Design Mix) 20mm graded aggregate in beams, cantilevers, bressumers, lintels etc , complete all as specified and directed by Engineer-in-Charge. |
| 9 | Material and labour for reinforced cement concrete M-25 (Design Mix) 20mm graded aggregate in slab supported on walls, basement walls, ballast walls, & the like, any thickness, above top of footings, including attached pillasters & buttresses complete |
| 10 | Material and labour for reinforced cement concrete M-25 (Design Mix) 20mm graded aggregate in walls, retaining walls, basement walls, ballast walls and the like, any thickness , above top of footings , including attached pilasters and buttresses , complete all as specified and directed by Engineer-in-Charge. |
| 11 | Material and labour for reinforcement 10mm dia and over TMT bars including cutting, bending and binding with 0.9mm dia binding wire , complete all as specified and directed by Engineer-in-Charge. |
| 12 | All as per item 11 here in before but5mm dia and over upto and including 10mm dia in stirrups , spacers & binders, complete all as specified and directed by Engineer-in-Charge. |
| 13 | Excavation over areas n. exc. 1.5 m deep & getting out soft/loose soil , complete all as specified and directed by Engineer-in-Charge. |
| 14 | Formwork to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffit of foundation & plinth beams & similar work rough finished , complete all as specified and directed by Engineer-in-Charge. |
| 15 | Formwork to sides & soffit of floor & roof beams, beam haunchings, girders, bressumers, lintels,cantilevers, shelves including, supportsoverhang etc fair finished, complete all as specified and directed by Engineer-in-Charge. |
| 16 | Formwork to sides of pillars, posts, struts, piers, columns, stanchions complete fair finished, complete all as specified and directed by Engineer-in-Charge. |
| 17 | Formwork to soffits of suspended slabs such as roof slab, floor slab, landing, & similar work n. exc 300 mm thick horizontal or sloping complete fair finished, complete all as specified and directed by Engineer-in-Charge. |
| 18 | Formwork to edges of concrete flats, treads, breaks in floors, eindow cills, concrete railing, opening in walls, floor & roofs n exc 20cm & sides of RCC/pcc bands in walls, horizontal or sloping and similar work exceeding 10cm but n exc 20cm wide, complete all as specified and directed by Engineer-in-Charge. |
| 19 | Formwork to faces of walls, retaining walls , abutments, parapets & staircase railings & similar work including attached pillasters , buttresses etc vertical or to batter , complete all as specified and directed by Engineer-in-Charge. |
| 20 | Material and labour for rectangular glazed ceramic coloured tiles in vertical surface exc area of each tile 0.36 sqm n exc 1 sqmset and jointed in neat cement slurry and pointed in white or coloured cement to match as in skirting/Dado over 10mm thick rendering in CM 1:4 , complete all as specified and directed by Engineer-in-Charge. |
| 21 | Material and labour for coloured Non Skid ceramic tiles (square/rectangular) area of each tile exceeding 0.30 but not exceeding 0.64 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM 1:6 , complete all as specified and directed by Engineer-in-Charge. |
| 22 | Material and labour for 5mm thick cement rendering in CM 1:3 on fair faces concrete surfaces inceiling after hacking the concrete surface , complete all as specified and directed by Engineer-in-Charge. |
| 23 | Material and labour for 10 mm thick cement rendering in CM 1:6 on fair faces of brick work or concrete surfaces including the provision of groove in plaster at junction of brickwork & concrete surfaces , complete all as specified and directed by Engineer-in-Charge. |
| 24 | Material and labour for 15 mm thick cement rendering in CM 1:4 on other than fair faces of brick work or concrete surfaces including provision of 300mm wide chicken wire mesh on junction of concrete & brick work , complete all as specified and directed by Engineer-in-Charge. |
| 25 | Supply and fixing Vitreous China Half stall urinal complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, flush pipe, SS bottle trap and Union for discharge pipe, complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply and fixing of vitreous counter top china wash hand basin of size 480x380x160mm fixed on to granite surface with all fittings and acessories required including PVC connection 450mm long 02 Nos connected to central hole mixer and chromium plated waste coupling including SS bottle trap, central hole mixeretc , complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply and fixingVitreous china wash down water closet pan (Pedestal pattern) having connected flushing cistern, having size 645x365x702mm of Model Zest C8810 (S-110) of Parryware or equivalent including connection with trap & seat cover , complete all as specified and directed by Engineer-in-Charge. |
| 28 | Supply and fixing vitreous china squatting pan, \"Orissa\" pattern , size 580x440mm white, with integral footrest (excluding cistern & flush pipe ) fixed with concrete , complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply and fixing PVC valveless, syphonic action type flushing cisterns 10 ltrs capacity , low level , white, with inlet ball valves , float and handle including brackets and pvc flush pipe 32 mm bore low level , fixed in repairs , complete all as specified and directed by Engineer-in-Charge. |
| 30 | Supply and fixingSS peg set of 5 size 300x20x2.5mm , complete all as specified and directed by Engineer-in-Charge. |
| 31 | Supply and fixing polished chrome finish health faucet with 1.2m pipeincluding hoze & bracket holder , complete all as specified and directed by Engineer-in-Charge. |
| 32 | Supply and fixing toilet paper holder in chrome finish of make Kohler or equivalent , complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply and fixing Bib tap pressmatic with aerator and wall flange, fancy type , suitable for 15 mm bore pipe, , complete all as specified and directed by Engineer-in-charge. |
| 34 | Supply and fixingstainless steel grating openable 100mm size with/without hole with PVC floor trap including fixing with white cement , complete all as specified and directed by Engineer-in-charge. |
| 35 | Supply and fixingStop valves, cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore complete all as specified and directed by Engineer-in-charge. |
| 36 | Supply and fixing Soap dish any type, fixed to plugs with chromium plated brass screws , complete all as specified and directed by Engineer-in-charge. |
| 37 | Supply and fixing chromium plated, towel rail, 20mm dia, D type, 60cm long between flanges , complete all as specified and directed by Engineer-in-charge. |
| 38 | Supply and fixing vitreous china urinal of size 295x325x575mm starwhite wall hung sensor based complete including SS bottle trap, urinal spreader & stop valve, complete all as specified and directed by Engineer-in-charge. |
| 39 | Supply and fixing toughened glass frosted partition 6mm thick fixed on wall / floor with SS cleats & supports in approved shape, complete all as specified and directed by Engineer-in-charge. |
| 40 | Supply and fixingframeless toughened glass swing door 12mm thick alongwith necessary arrangements for floor machine & door movement top arrangement, ss plate over floor machine, necessary 40mm SS pipe 300mm long handles in each panel, 5 lever mortice locks, complete all as specified and directed by Engineer-in-charge. |
| 41 | Supply and fixing wall mixer cast copper alloy with bend pipe for overhead shower for \"Hot\" or \"Cold\" screwed down for 15mm bore iron pipe or brass ferrule complete all as specified & as directed by Engineer-in-Charge |
| 42 | Supply and fixing chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union with shower arm, complete all as specified and directed by Engineer-in-charge. |
| 43 | Material and labour for 18 to 20mm thick Granite stone of black shade work (table rubbed, polished & moulding), as in floors, washbasin counters and like bedded with and including 15 mm thick screed bed in CM (1:4) and jointed with grey cement slurry @ 3 Kg/Sqm, and pointed with white with admixture of pigment to match with shade of granite stone including grinding, polishing, rounding and moulding of stone slabs on edges , complete all as specified and directed by Engineer-in-charge. |
| 44 | Supply and fixing in bevelled edge mirror of selected quality glass thickness 5mm, mounted on 6 mm thick AC bldg board or commercial plywood, fixedwith aluminium angled frame and required CP MS hanging arrangements, complete all as specified and directed by Engineer-in-charge. |
| 45 | Supply and laying of CPVC pipes 16mm OD SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors , complete all as specified and directed by Engineer-in-charge. |
| 46 | Supplying and laying of CPVC pipes 20mm OD SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors , complete all as specified and directed by Engineer-in-charge. |
| 47 | Supply and fixing water storage tank of 1000 ltr capacity, HDPE double layer, ISI marked, fixed and hoisted in position on staging or roof complete with locking arrangement including over flow pipe, air lock pipe, brass valve 20 mm high pressure with polythene float and flynut, ISI marked, screwed andsuitable for iron pipe 20 mm bore , complete all as specified and directed by Engineer-in-Charge.Note:- Make of tank shall be engraved on the tank. |
| 48 | Supply and fixing PVC Connections 15 mm size with PTMP nuts of length 450mm, complete all as specified and directed by Engineer-in-charge. |
| 49 | Supply and fixing 110 mm bore PVC (SWR) Soil, waste single socketed pipe in any length with rubber ring joints laid in floors or trenches , complete all as specified and directed by Engineer-in-charge. |
| 50 | Supply and fixing 110 mm bore PVC (SWR) Soil, waste single socketed pipe in any length with rubber ring joints fixed on wall, complete all as specified and directed by Engineer-in-charge. |
| 51 | Supply and fixing 75 mm bore PVC (SWR) Soil, waste single socketed pipe in any length with rubber ring joints laid in floors or trenches , complete all as specified and directed by Engineer-in-charge. |
| 52 | Supply and fixing 75 mm bore PVC (SWR) Soil, waste single socketed pipe in any length with rubber ring joints fixed to walls , complete all as specified and directed by Engineer-in-charge. |
| 53 | Supply and fixing 110 mm bore PVC (SWR) bends of any radius , complete all as specified and directed by Engineer-in-charge. |
| 54 | Supply and fixing 75 mm bore PVC (SWR) bends of any radius , complete all as specified and directed by Engineer-in-charge. |
| 55 | Supply and fixing 110 mm bore dia PVC (SWR) reducers , complete all as specified and directed by Engineer-in-charge. |
| 56 | Supply and fixing PVC (SWR) vent cowl 75 mm bore , complete all as specified and directed by Engineer-in-charge. |
| 57 | Material and labour for salt glazed stoneware gully trap, square or round moulded type \"P\", 100x100mm size , complete all as specified and directed by Engineer-in-charge. |
| 58 | Supply and fixingof ventilators made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 48 x 25mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy duty stain less steel pivot hinges shall be provided per shutter. The windows should be paneled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 10mm square guard bars with 6” (152.4mm) pitch, complete for finished with suitableprovision as in ventilator in toilet/bathroom/staircase (Make: A2Z Infra Solutions/ Elixir Metform Pvt Ltd./ Lakshmi Fabrications) , complete all as specified and directed by Engineer-in-charge. |
| 59 | Cuttingchases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends of edges of landings, steps, cills etc., and cutting chases for concealed water tubing and making good, complete all as specified and directed by Engineer-in-charge. |
| 60 | Supply & fixing of solid WPC door frame size 100mm x 65mm single rebate made from 100% lead free (single extruded process) material with density 780 kg/ cum & manufactured by ISO :9001-2015 certified company , all as per specification drawings as directed by Engr-in-Charge. The door frame should be water proof , termite proof, fire retardant and having excellent screw holding capacity, complete all as specified and directed by Engineer-in-charge. |
| 61 | Supply and fixing30mm thick moulded WPC factory made 100% solid door (confirming as per IS :4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with wood grain texture and back side plain with density not less than 600kh/cum. Manufactured by an ISO :9001-2015 certified company. The door should be water proof, termite proof, fire retardant and having screw holding capacity including fixing in frame at site with 3 Nos stainless steel butt hinges , 2 Nos aluminium tower bolt 150mm,02 Nos aluminium handles 150mm for each shutter all as per specification & drawing, complete all as specified and directed by Engineer-in-charge. |
| 62 | Material and labour forPCC in 1:3:6 type C-1 (using 20mm graded mechanically crushed stone aggregate) 50 mm thick as in plinth protection/path, laid in alternate bays etc.finished even and smooth without using extra cement and joints filled with bitumen and sand mixture applied hot all as specified |
| 63 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/loose soil , complete all as specified and directed by Engineer-in-charge. |
| 64 | Material and labour for providing 3 mm thick APP (Atactic polypropylene polymer) modified prefabricated five layer, weight not less than 3.6 Kg/Sqm water proofing membrane, black finished, reinforced with Non-woven polyster matt make as approved over roof consisting of a coat of bitumen primer @ 0.40 Ltr/Sqm by same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25º C temperature and viscocity 70-160 Cps. over the primer coat, the layer membrane shall be using butane torch and sealing all joints etc. after preparing the surface complete applying two coats of bituminous based Aluminium paint @ 0.2kg/sqm complete over and including 10mm thick cement plaster in CM (1:4) on RCC roof slab including cleaning of existing using WPC @ 2% by wt of cement complete as per standard practice as per manufactuter\"s instructions all as specified and directed.The vital physical and chemical parameters of the membrane shall be as under:-(i) Joint strength in longitudinal and transverse direction at 25º C as 650/450 N/5 Cms.(ii) Tear strength in longitudinal and transverse direction as 300/250N/5 Cms. Softening point of membrane not less than 150º C cold flexiblility up to 20º when tested in accordance with ASTM (D-5147)(iii) The laying of membrane shall be carried out through the manufacturer or their authorized applicator only. |
| 65 | Material and labour for treating top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface (ATT) , complete all as specified and directed by Engineer-in-charge. |
| 66 | Material and labour for treating the backfill in contact with foundation at the rate of 7.5 lit of emulsion per sqm of vertical surface ( area of substructure in contact with backfill to be measured), complete all as specified and directed by Engineer-in-charge. |
| 67 | Material & labour for preparation of new plastered surfaces ofceiling and applying two coats of oil bound distemper , over a coat of alkaline resistant primer & 1 mm thick putty complete all as specified and directed |
| 68 | Material & labour for preparation of new plastered surfaces of walls and applying two coats of exterior emulsion paint , over a coat of alkaline resistant primer & 1 mm thick putty , complete all as specified and directed by Engineer-in-charge. |
| 69 | Material & labour for preparation of exposed brick wall /concrete surface by cleaning the surface with wire brush to remove all dirt/loose materials from the bricks and from the joints between the bricks.Prepared surface should be then washed with diluted HCL acid (dilution ratio of 1:50) for three times in a day for two days. After acid wash surface should be allowed to be air dried for one day.Note : Further treatment over the surface so achievedwill be carried out only after approval of the same by GE. Note:- This item shall be executed by authorised applicator only. for carrying out efflorescence treatment to exposed and prepared wall surfacehere–in–abovein following sequence :–(a) Prime the prepared surface with one of the following product mixed with cement in 1:1ratio as bonding agent :–(i) Pidicrete URP of M/S Pidilite(ii)Sika Latex of M/s Sika(iii) Nitobond SBR Latex of M/s FOSROC (b) Immediately after priming the surface PMM (Polymer Modified Mortar) to be applied \"BY HAND\" while the primer is tacky.10 mm thick PMM should be prepared by mixing one of the following compounds in Cement Mortar 1:3 as per manufacturer\"s instructions :–(i) Pidicrete URP of M/S Pidilite(ii)Sika Latex of M/s Sika(iii) Nitobond SBR Latex of M/s FOSROC(c) PMM surface should be allowed to dry one day.After that it shoud painted with two coats of one of the following compound mixed with cement only in ratio of one part of selected com-pound and one point five part of cement :–(i) Pidicrete URP of M/S Pidilite(ii)Sika Latex of M/s Sika(iii) Nitobond SBR Latex of M/s FOSROC(d)Now apply two coats of one of the following compound over the surface.These compounds are to be used as per manufacturer instructions :–(i) Pidifin 2K of M/S Pidilite(ii)Brush Coat of M/s Sika(iii) Brush Bond of M/s FOSROCNote : Both coats should be perpendicular to each other and gap between two coats shall be minimum 6 hours.(e) Sprinkle loose coarse sand after second coat while surface is tacky. Note: (i) Item will be executed by authorised applicator of the selected /approved company only. (ii) Every stage of work will be approved by GE then only next layer will be executed by contractor. |
| 70 | Removal of excavatedmaterial(soil) to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point , complete all as specified and directed by Engineer-in-charge. |
| 71 | Material and labour for Broken stone or boulders Hardcore of gauge n exc. 63mm deposited, spread and levelled in layers n exc. 15cm thick, watered andrammed to a true surface , complete all as specified and directed by Engineer-in-charge. |
| 72 | Supply and fixing Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with Grey cement &pigment, complete all as specified and directed by Engineer-in-charge. |
| 73 | Material and labour for Sand filling under floors or in foundation including watering & consolidation 25mm thick for, complete all as specified and directed by Engineer-in-charge. |
| 74 | Material and labour for precast cement concrete Type B1 1:2:4 (20mm graded aggregate) kerb stones with solid blocks exc 10cm in width & setting in mortar 1:4, complete all as specified and directed by Engineer-in-charge. |
| 75 | Excavating in post holes(or similar holes) each n exc 0.5cum , getting out , returning filling in and ramming earth or broken rubble mixed earth around , in layers not exceeding 25cm thick in soft / loose soil, complete all as specified and directed by Engineer-in-charge. |
| 76 | Material and labour for plain cement concrete in foundations, filling & mass concrete1:2:4 Type B2 (40mm graded aggregate), complete all as specified and directed by Engineer-in-charge. |
| 77 | Supply and fixing steel work in tubular struts, frames, trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161-1979 grade St-240 , complete all as specified and directed by Engineer-in-charge. |
| 78 | Material and labour for plates (plain or chequred) channels, square cut or notched (ordinary or counter sunk ) forming holes , without any attachment Gde Fe-410-W(Gde E-250) quality B, complete all as specified and directed by Engineer-in-charge. |
| 79 | Supply and fixing Mild steel bolts dia of neck exc 20mm but n. exc 25mm made with hexagonal or square head one end screwedthe other, or screwed both ends, each end screwed to be fitted with washers & one hexagonal or square not exc 30cm long, complete all as specified and directed by Engineer-in-charge. |
| 80 | Supply and fixing polycarbonate sheet of approved colour 3mm thick to be fixed on frame, chajjas, roof sheets as per approved desifn & confirm to properties as per relevant IS including overlapping & wastage, complete all as specified and directed by Engineer-in-charge. |
| 81 | Material and labour for applying two coats of Synthetic enamel paintover one coat of red oxideprimer on new Steel surfaces over 10cm width or girth including preparing new surfaces to receive painting, complete all as specified and directed by Engineer-in-charge. |
| 82 | Excavation over areas for additional 1.5m or part thereof in depth beyond 1.50m complete all as specified & as diretced |
| 83 | Material and labour for brickwork with sub class \"B\" bricks, straight or curved on plan exc 6m mean radius , built in 1:6 cement mortar complete all as specified & as diretced |
| 84 | Material and labour for rendering 15mm thick on fair faces of external walls with 1:4 cement mortar complete all as specified |
| 85 | Supply and fixing CI pipe 100 mm complete all as specified and directed by Engineer-in-charge. |
| 86 | Material and labour MS TMT Bars 6 to 8mm dia and over cut to length, bend to shape required, incl cranking, bending, for hooping for columns, hooking ends and binding with and incl MS wire (Annealed) not less than 0.9mm dia or securing with clips , complete all as specified and directed by Engineer-in-charge. |
| 87 | Material and labour for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in surface channel/ drains inside the manholes, coping, benching and the like, complete all as specified and directed by Engineer-in-charge. |
| 88 | Extra over for forming fair finished to drains or channels n exc 30 cminnergirth in cement concrete using extra cement including forms moulds, mitered/ stopped ends , complete all as specified and directed by Engineer-in-charge. |
| 89 | Material and labour for precast RCC 1:2:4 Type B-1 (using 20mm graded crushed stone aggregate ) as in manhole covers, including necessary formwork etc, set and jointed in CM 1:4 complete etc complete all as spd & as directedNote : reinforcement shall be measured and paid separately under respective item |
| 90 | Material and labour for reinforced concrete pipes, 150mm bore , class NP3 , laid & jointed complete with collars laid in trenches at any depth including jointing & testing complete all as spe & as directed |
| 91 | Material and labour for concrete bed to drain pipes 150mm dia including packing under and haunching against the sides of pipes after they are laid & tested in cement concrete 1:3:6 type C-2 (using 20mm graded crushed stone aggregate ), complete all as specified and directed by Engineer-in-charge. |
| 92 | Supply & filling of broken brick bats in soakage well of 2nd class bricks complete allas specified |
| 93 | Supply and lay Tubes, `medium grade\", galvanised, 40 mm bore, with all fittings; laid in trenches/ fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 94 | Supply and lay Tubes, `medium grade\", galvanised, 20 mm bore, with all fittings; laid in trenches/ fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 95 | Supply and fix Gun metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipes and fixedof 20 mm dia. |
| 96 | Material and labour for cutting/tapping existing CI/GI pipe of any bore in positionfor insertion of new TEEon any bore of pipe complete all as specified and directed. |
| 97 | Supply, laying and testing cable PVC Insulated ,armoured, heavy duty electric cable 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4core, filixng along with wall / roof complete all as specified and directed. |
| 98 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, heavy duty electric cable 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core, complete all as specified and directed by Engineer-in-charge. |
| 99 | Supply and fixing for GI protection pipe of 40mmdia light grade for cable protection including all fittings laid in trenches or fixed on pole, complete all as specified and as directed. |
| 100 | Material and labour for old size bricks sub class \"B\" for cable protection laid along length of cable complete all as specified and as directed. |
| 101 | Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and includingPVC conduit not less than 20mm dia with and including accessories, concealed on wall/ and surface on ceilingand its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI metal flushboxes made out of 1.2mm thick of any module from 2 to 18module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbedsurfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dollywith suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed.NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately.2. All chases will be cut by chase cutter only. |
| 102 | Description all as per item No 101 here in before but for socket out let point 5 Amps on same board |
| 103 | Description all as per item No 101 here in before but for socket out let point 5 Amps on independentboard |
| 104 | All as per srl item No 101 above but point wiring for one socket out let 15 & 5 Amps (independent) controlled by one switchwith using 2.5 Sq mm (nominal area) stranded copper conductor |
| 105 | Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal , complete all as specified and directed by Engineer-in-charge. |
| 106 | Supply and fixingmodular switches, one way,6 amps one module, 230V, 50 Hz supply, complete all as specified and directed. |
| 107 | Supply and fixingmodular switches, one way,16 amps one module, 230V, 50 Hz supply, complete all as specified and directed. |
| 108 | Supply and fixingsocket outlet 2/3 pin combined 2 module, 6 amps, 230 volts moduler type ,ISI Marked, , complete all as specified and directed by Engineer-in-Charge. |
| 109 | Supply and fixingsocket outlet 2/3 pin combined 2 module, 6Amp / 16 Amps, 230 volts moduler type ,ISI Marked, , complete all as specified and directed by Engineer-in-Charge. |
| 110 | Supply and fixing of LED luminaries of capacity 20 watt integrated aluminium batten with including Oppel diffuser complete including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and as directed. |
| 111 | Supply and fixsurface mounted LED tube light fitting with high efficient diffuser mirror light, aluminium housingin CRCA body suitable and including 10 watt LED tube high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. |
| 112 | Supply and fixing in replacement bracket for security light made up of 25/40 mm dia,0 9m long GI pipe,light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts , complete all as specified and directed by Engineer-in-Charge. |
| 113 | Supply and fixLED security light luminaire 30/35 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP65 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W eachand having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any position complete all as specified and directed. |
| 114 | Supply and fixing Bulk Head Fitting 10 Watt and connected withcopper conductor cable of size 1.50 Sqmm,for fixing the light fittingcomplete all as specified & directed. |
| 115 | Supply and fix in repair sheet steel enclosure with saperate busbar chamber for cable terminationwith and including MCCB four pole, 240 volts, 50Hz , breaking capacity 25 KA, 125 Amps, B curve,all as specified and and as directed. |
| 116 | Supply and fixing MCB DB4 way TPN double door powder coated complete alongwith 200 Amp rated Bus bar, 415 Volts rated bus bar IP 43 protection, suitable forMCB 4 Pole 63 Ampas incommer. Note: Thimble/lugs of rating of MCB TPN should be used with wire for fixing in the MCB. Complete all as specified and directed. |
| 117 | Supply and fixing in repair SPN distibution board 8 way, double door, IP 43, as per IS 8623including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles complete all as specified and directed. |
| 118 | Supply and fixing 240 V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB complete with connection testing and commissioning. |
| 119 | Supply and fixing 240 V, 10 KA \"B\" curve miniature circuit breaker (MCB) of SPN and current carrying capacity 40 to 63 Amp, in the MCB DB complete with connection testing and commissioning. |
| 120 | Supply and fixing 240 V, 10 KA \"B\" curve miniature circuit breaker (MCB) of SP and current carrying capacity 40 to 63 Amp, in the MCB DB complete with connection testing and commissioning. |
| 121 | Supply and fix MCB TPN63 Amps,440 volt,10 KA \"B\" curve, complete all as specified and directed by Engineer-in-Charge. |
| 122 | Supply and fixing Exaust fan 300 mm Sweep AC single phase 230 Volts of size 1400RPMmetal body with louvers including fixing arrangment , making hole of suitable size complete as specified and directed. |
| 123 | Material and labour for sub main wiring with two single core FRLSH, PVCinsulatedunsheathed copper conductor cable 6.0 sq mm drawnin and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSH of 6.0 sqmm,green colourfor earthcontinuity conductor including including taking down old unserviceable sub main wiringand making good the disturbed surface complete,all as specified and directed. |
| 124 | NOTE:- Amount of credit ofRs. 0.00 for retrieved materials is mentioned in Schedule of Credit Page No 21 & 22 of tender documents in pdf form which will be deducted offline while acceptance of tender. |