| 1 | Fabrication, supplying, installation, and commissioning of LED Bollard Light of MS Sheet i/c Laser cutting, making design as approved by Engineer In charge and welding the same and making suitable arrangement for mounting of 6-8 watt LED Down lighter i/c PU painted, foundation nut bolt excluding foundation complete etc. as required including 6-8/10 2 no. down lighter. |
| 2 | SITC of 8 to 10W LED cone type bollard light made up of pressure die cast powder coated housing with Polycarbonate diffuser, high efficiency long life, surge voltage, over voltage protection, open circuit, short circuit protection and other safety test as per IS 15885 part-2 etc as reqd. |
| 3 | P & L cement concrete in kerbs, steps and like at or near gound level excluding the cost of centering, shuttering and finishing 1:1 1/2 :3 ( 1 Cement : 1 1/2 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 4 | Providing and fixing of LED globe light of rice paper material having diameter 10 inch with wired and metal frame to sustain lantern shape suitable for rated voltage 220 volts 50 Hz supply in White/ Green/ Red/ Warm White Colours including allaccessories like B22 holder and 10 watt LED warm white/coolwhite/neturalwhite bulb, making connections asrequired,etc. |
| 5 | Providingand fixing of flexible LED String lightsuitable for rated voltage 220 volts 50Hz supply,inWhite/Green/Red/WarmWhite Coloursincludingallaccessorieslike connectors, integratedLEDadaptor etc. as required. |
| 6 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 7 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as reqd. |
| 8 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2X6 sqmm |
| 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 10 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm |
| 11 | S & L of following size DWCHDPE pipe ISI marked along withall accessoried like socket ,bend,couplers etc. Confirming to Is 14930, Part II complete with fittings and cutting jointing etc. Diret in ground (75 Cm below ground level) including excavation and refilling the trench but excluding sandcushioning and protective covring etc. complete as reqd. (a) 63 mm dia (OD-63mm & ID-51 mm nominal.) |