| 1 | Dismantling all types of masonry excepting cement concrete plain of reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor. |
| 2 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor. |
| 3 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. In ground floor. |
| 4 | Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m.a) In ground floor including roof. |
| 5 | Scraping of moss, blisters etc. thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge). |
| 6 | Removing old scales, blisters etc. of interior surface of walls, ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper. (Payment againt this item will be made only when this has been done on the specific direction of the Engineer-in-Charge). |
| 7 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish and stacking anywhere within the compound as directed. |
| 8 | Removal of rubbish, earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge. |
| 9 | Single brick flat soling of picked jhama bricks including removing & dressing bed to proper level & filling joints with powered earth or local sand. |
| 10 | Ordinary Cement Concrete (mix 1: 2: 4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.Pakur variety. Consider a distance of 8 Km from Sealdah Railway station. |
| 11 | Ordinary Cement concrete (Mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes..(a) Pakur Variety. Consider a distance of 8 Km from Sealdah Railway station |
| 12 | Cement concrete with graded stone ballast (40 mm size excluding shuttering). In ground floor. Pakur variety. 1:3:6 proportion. |
| 13 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor)a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.i) Up to the roof of Ground floor. |
| 14 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. Tor Steel/Mild Steel. JSW/Electrosteel/Shyam/SRMB/Elegant(a) For works in foundation, basement and uptoroof of ground floor / upto 4m. |
| 15 | Brick work with 1st class bricks in cement mortar (1:6)i) In Superstructure ground floor. |
| 16 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]. With 1:6 cement mortar.i) 20 mm thick plaster with (1:6) cement mortar. |
| 17 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]. With 1:6 cement mortar.ii) 15 mm thick plaster with (1:6) cement mortar. |
| 18 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]. With 1:6 cement mortar.iii) 10 mm thick plaster with (1:4) cement mortar. |
| 19 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. |
| 20 | Applying Inerior grade Acrylic Primer of approved quality and brand on plaster or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. One coat. Water based interior grade Acrylic Primer. In Ground Floor. |
| 21 | Applying Acrylic Emulsion paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer): Two coats: Standard Quuality. |
| 22 | Applying exterior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative texture (matt finish) or smooth finish Acrylic exterior emulsion paint including scrapping and preparing the surface thoroughly, complete as per manufacturer’s specification and as per direction of the EI. Water based interior grade Acrylic Primer. One coat. In ground floor. |
| 23 | Protective and decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rates includes cost of materials labour, scaffolding and all incidental charges but excluding the cost of primer. (Two coats). Premium Acrylic Emulsion. In ground floor. |
| 24 | b) Priming one coat on steel or other metal surfacewith synthetic oil bound primer of approved quality including smoothening surface by sand papering etc. |
| 25 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary.b) On steel or other metal surface. With super gloss (hi-gloss). Two coats (with any shade except white). |
| 26 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement(iii) 35 mm. thick |
| 27 | Supplying, fitting & fixing UPVC pipes A-Type and fittings conforming to IS: 13592-1992 with all necessary clamps nails, including making holes in walls, floors etc. cutting trances in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materials (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.i) UPVC Pipes. |
| 28 | Supplying, fitting & fixing UPVC pipes A-Type and fittings conforming to IS: 13592-1992 with all necessary clamps nails, including making holes in walls, floors etc. cutting trances in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materials (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.iii) Bend 87.5 degree, 110mm dia. |
| 29 | Supplying, fitting & fixing UPVC pipes A-Type and fittings conforming to IS: 13592-1992 with all necessary clamps nails, including making holes in walls, floors etc. cutting trances in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materials (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.ii) Shoe |
| 30 | M.S. works in framed gratings of window etc.made of round or square bars and frame work or M.S. flats (with the bars securely fixed to the flat bar frame) with or without intermediate flat bar stiffener and fixed with necessary screws etc. complete, as directed. (For fixing chequered plate)In ground floor. |
| 31 | 125 mm thick brick work with 1st class bricks in cement mortar (4:1). In super structure ground floor. |
| 32 | M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.In ground floor. |
| 33 | A) Supplying & laying of approved brand of scratch proof, semi flexible P.V.C. blended homogeneous marble Vinyle flooring in tiles conforming to IS:3461, fixing with synthetic acrylic adhesive after preparing the floor, levelling & smothaning when necessary with suitable putty, as per the design & instruction of the Engineer-in-charge.2 mm thick |
| 34 | Supplying, fitting & fixing steel windows and ventilator with or without integrated grills conforming to I.S. 1038 – 1975 and manufactured from rolled steel section conforming to I.S. 7452 – 1974 with non-friction projecting type, box type hinges, glazing clips, lugs, locking brackets, handle plate etc. including hoisting in position strengthening if required, fixing lugs in cement concrete (4:2:1) with stone chips 19mm. down, cutting holes & mending good damages to match with the existing surface complete in all respect excluding glazing. In ground floor. Flash but welded windows & ventilators. Without integrated grills.(viii) M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S. flats and bars. |
| 35 | Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. 4 mm thick. |
| 36 | Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand (1.5mm thick) |
| 37 | Supplying ‘Godrej’ mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete. |
| 38 | Door stopper. (Brass) |
| 39 | Anodized aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws. 225 mm long X 12 mm dia bolt. |
| 40 | Anodised alluminium butt hinges of approved quality manufactured from extruded section conforming to I.S specification (IS: 205/66) and fitted and fixed with cadmium plated screws. 100 x 75 x 4.0mm. |
| 41 | Anodized alluminium ‘D’ type handle of approved quality manufactured from extruded section conforming to I.S specification (IS: 230/72) fitted and fixed complete. With continuous plate base (hexagonal/ round rod). 125mm. grip x 12mm. dia rod. |
| 42 | Supplying profiles of required section made of alluminium alloy extrusions conforming to IS: 733/1983 and IS: 1285/1975; anodized (with required film thickness and specified colour/ natural) matt finished conforming to IS: 1868/1983 for fabrication of composite door, sliding and casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer-in-Charge. In 10 to 12 micron thickness anodizing film. Natural white. B) Movable door shutter.i) Door frame. (Top & sides). |
| 43 | Supplying profiles of required section made of alluminium alloy extrusions conforming to IS: 733/1983 and IS: 1285/1975; anodized (with required film thickness and specified colour/ natural) matt finished conforming to IS: 1868/1983 for fabrication of composite door, sliding and casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer-in-Charge. In 10 to 12 micron thickness anodizing film. Natural white. B) Movable door shutter.ii) Shutter : (a) Top Rail |
| 44 | Supplying profiles of required section made of alluminium alloy extrusions conforming to IS: 733/1983 and IS: 1285/1975; anodized (with required film thickness and specified colour/ natural) matt finished conforming to IS: 1868/1983 for fabrication of composite door, sliding and casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer-in-Charge. In 10 to 12 micron thickness anodizing film. Natural white. B) Movable door shutter.(b) Bottom rail |
| 45 | Supplying profiles of required section made of alluminium alloy extrusions conforming to IS: 733/1983 and IS: 1285/1975; anodized (with required film thickness and specified colour/ natural) matt finished conforming to IS: 1868/1983 for fabrication of composite door, sliding and casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer-in-Charge. In 10 to 12 micron thickness anodizing film. Natural white. B) Movable door shutter.(c) Lock rail |
| 46 | Supplying profiles of required section made of alluminium alloy extrusions conforming to IS: 733/1983 and IS: 1285/1975; anodized (with required film thickness and specified colour/ natural) matt finished conforming to IS: 1868/1983 for fabrication of composite door, sliding and casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer-in-Charge. In 10 to 12 micron thickness anodizing film. Natural white. B) Movable door shutter.(d) Door vertical |
| 47 | Supplying profiles of required section made of alluminium alloy extrusions conforming to IS: 733/1983 and IS: 1285/1975; anodized (with required film thickness and specified colour/ natural) matt finished conforming to IS: 1868/1983 for fabrication of composite door, sliding and casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer-in-Charge. In 10 to 12 micron thickness anodizing film. Natural white. B) Movable door shutter.(e) Glazing clip. |
| 48 | A) Partly glazed partly paneled or fully glazed single leaf alluminium swing door made of extruded and anodized alloy alluminium sections, fabrication including cutting to proper shape and size, drilling and aligning fittedwith heavy duty hydraulic actionfloor spring placed in the floor with mending damages with top pin assembly of approved make and brand, fitted with in-builtlocking arrangement, flush bolt, glazing clips and all other necessary fittings, fixture, adhesive and joineries, cutting glass of approved make to requisite shape and size fitting with dry set neoprene or EPDM gasketing,cutting to requisiteshape and size panel board (pre-laminated /particle block) fixing them with glazingclips as per drawing, specification and direction of Engineer-in-charge. |
| 49 | Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete.Medium (I.S.I. size 2) |
| 50 | Supplying fitting and fixing in position approved PVC door frame (matt finish) made of extruded PVC multichamber hollow section having dimensions 60mm X 50mm X 2mm (± 0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm X 20mm X 1.2 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of PVC expendable fastener wooden gulties and galvanised steel screws including cost of all materials and labour, hirecharges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete. |
| 51 | PVC door shutter 30 mm thick: Supplying, fitting & fixing PVC door shutter of approved quality and shade in position, the style and rail of the PVC door shutter will be made of rigid PVC multi-cavity hollow chamber of 59 mm X 30 mm section with 2 mm (± 0.2mm) wall thickness horizontal and vertical section shall be fixed to each other by self tapping screws and one solid polymeric/ MS galvanized tubular L-shaped brackets 100 mm X 200 mm in each corner of the shutter frame for placing hinges. Polymer based multi-cavity holo section of 120 mm X 30 mm with 2 mm (± 0.2mm) wall thickness will be placed in the middle, reinforced by solid polymer bar of 200 mm long at both end and screws from both sides as lock rail. The section frame will then be fitted in by PVC panels of size 100 mm X 25 mm with wall thickness 1.2 mm (± 0.2mm) and 2 nos of 6 mm dia bright rod will be inserted horizontally with both sides checked and nut system and stretches where fixing of hinges or hasp bolt or tower bolt or door ring are required to be strong enough to with stand wire and tear. The rate is inclusive of cost of all materials and labour, hire of tools and plants appliances. Carriage of all materials taxes and all other incidental charges complete. The rate is exclusive of cost of hinges, hasp bolt, tower bolt, door ring etc. in ground floor. |
| 52 | M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete.The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc.Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work.Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof.i) For trusses spanning up to 12.00 m |
| 53 | Supplying , fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap.(Payment to be made on area of finished work).(i) In Roof:-a) With 0.5 mm thick sheet |
| 54 | Supplying, fitting and fixing super ivory endure (acid proof) tiles of 8 mm to 10 mm thick in walls, floor and skirting stair case etc. laid in panels or pattern as directed with cica advised and tiles grout with complete including all material and labours and all complete. |
| 55 | Fixing of LT Kiosk for 100 KVA DTR |
| 56 | Earthing of DCDB and Battery charger |
| 57 | Laying of 4 Core 120 sqmm 1.1 KV XLPE Cable |
| 58 | I/D termination for 4 Core 120 sqmm 1.1 KV XLPE Cable |
| 59 | Supply & Fixing of 2 Ton AC |
| 60 | Supply & fixing of 16 amp socket top. |
| 61 | Supply & fixing of 16 Amps 5 Pin plug |
| 62 | Supply & fixing of Starter for A.C. |
| 63 | Conduit type Pointwiring for Tube Lights,Fan,Exhust Fanetc. with 1.1 kv grade, 2x1C x 1.5 sq.mm including earth continuity by 1C x 1 sq mmPVC insulated stranded copper wire in 19 mm heavy dutynon - rigid PVC conduit with saddling complete. |
| 64 | Conduit type wiring for A.C and others with 2x1C x 4 sq.mm including earth continuity by 1C x 1.5 sq mmPVC insulated stranded copper wire. |
| 65 | Conduit type wiring for A.C and others with 4x1C x 10 sq.mm including earth continuity by 1C x 4 sq mmPVC insulated stranded copper wire. |
| 66 | Supply & fixing of 4\"\"/4\"\"PVC Box. |
| 67 | Supply & fixing of 4\"\"/4\"\" Modular PVC Box with Modular plate. |
| 68 | Supply & fixing of 100A Busbar. |
| 69 | Supply & fixing of 12 Way Double door D.Box (Metal). |
| 70 | Supply & fixing of 4 Way Double door D.Box (Metal). |
| 71 | Supply & fixing of 63 Amps MCB Isolator (3 Phase/4pole) |
| 72 | Supply & fixing of 20A M.C.B |
| 73 | Supply & fixing of 2 Way D.P Box (Metal). |
| 74 | Supply & fixing of 10A M.C.B |
| 75 | Installation AC Distribution Switchboard Panel |
| 76 | Dismantling & refixing of Tube Lights and making necessary wiring |
| 77 | Dismantling & refixing of Distribution box & making necessary wiring |
| 78 | Dismantling of Control Cables from Battery charger and refixing the same at DCDB with supply of cable gland |
| 79 | Shifting of Battery Charger and Battery Bank from old Battery room to New Battery room |
| 80 | Supply & fixing of DCDB suitable for 3 Nos Battery Charger set with interchangability options |
| 81 | laying of 4 Core 2.5 sqmm Cu Control Cable with terminal jointing, sockets etc. |