| 1 | Inspection and checking of summer appliances such asSplit /window type Air Conditioners, Refrigerators, deep freezer, water coolers of any size/capacity lodged by users in person and caring out necessary repair to the items as required at site complete all as specified and as directed by Engineer-in-Charge.Note: Items required the replacement will be measured and paid seperately |
| 2 | Supply only over load protector including relay with new over load protector including relayforRefrigerator& Deep Fridger of any Capacity complete all as specified. |
| 3 | Supply only Over Thermostat complete all as specified. |
| 4 | Supply only Over Capillary tube includingfilter / stainer complete all as specified. |
| 5 | Supply only Over load protector / relay package assembly with new relay package assembly for Water Coolers 40 / 80 Ltrsto 150/150 Ltrs capacity complete all as specified. |
| 6 | Supply only OverThermostat complete all as specified. |
| 7 | Supply only Over Capillary tube includingfilter / stainer complete all as specified. |
| 8 | Supply only Over Condensorfan motor 1/ 16 HP 230 volts including bladescomplete all as specified suitable for 40/80 , 60/120 & 150/150 Ltrs capacity. |
| 9 | Supply only Over PVC Ball valve high pressurewith polythene float and fly nut screwed for Iron pipe 15 mmdia complete all as specified. |
| 10 | Supply only Over GI / Stainless steel water drain tray as per suitable size complete all as specified. |
| 11 | Supply only Over Running Capacitor 10 / 25 MFD complete all as specified. |
| 12 | Supply only Over starting Capacitor 80 / 100 MFD complete all as specified. |
| 13 | Supply only Over Self closing taps, cast copper alloy, chromium platedscrewedfor iron pipe15 mm dia complete all as specified . |
| 14 | Supply onlyfan motor of existing capacity and size for1.5 Ton / 2.0 Ton capacitysplit type Air conditionerofany make and model complete all as specified. |
| 15 | Supply only Over fan blade set complete all as specified. |
| 16 | Supply only Over indoor unit blower motor complete all as specified. |
| 17 | Supply only Over Running capacitor36 / 45 MFD complete all as specified. |
| 18 | Supply only Over Running capacitor50 / 50+6 MFD complete all as specified. |
| 19 | Supply only Over remote control unit for Split type Air Conditioner of1.5 Ton/2.0 Ton capacity of any type and make complete all as specified |
| 20 | Supply and fixing Over PCB for inverter split AC / window AC any type and any make 1.5 Ton, 2 Toncapacity all as directed. |
| 21 | Supply and fixing Over PCB for non inverter split AC / window AC any type and any make 1.5 Ton, 2 Toncapacity all as directed. |
| 22 | Supply and fixing Over PCB circuit of disconnecting of electrical connection of fromsplit ACand taking out the unserviceable PCBand repair,anytype and any make 1.5 Ton, 2 Toncapacity all as directed. |
| 23 | Supply only Over capillary tube including filter/stainer complete all as specified |
| 24 | Supply only Over brass service valve complete all as specified |
| 25 | Supply only Over contactor complete all as specified and directed. |
| 26 | supply and fixing and testing of factory made hermatically sealed compressor includingrubber bushessleeves, washers, nutsand bolts, terminal covers, clips etc forRefrigerator of any capacity upto 320ltr complete all as specified. Note for item Nos 2 to 4: The gas required for charging shall be measured and paid separately under appropriate item of schedule of work |
| 27 | All as per sl item no 26 here-in-before but for Water Coolers 40 / 80 Ltrs complete all as specified. |
| 28 | All as per sl item no 26 here-in-before but for Split typeAC 1.5/2.0 Ton capacity complete all as specified. |
| 29 | M&L for taking out condenser/ evaporator unit of split type Air Conditioner of any capacity and rectifiy leakage/ blockage of refrigerant and refixing the same after carryout necessary repairs complete all as specified and directed. |
| 30 | Supply and replace copper condenser unit of split type Air Conditioner of 1.5/2.0 Ton capacity complete all as specified |
| 31 | S&F in replacement of complete indoor unit suitable for outdoor unit with complete fittings like copper coil, temperature display, blower motor, PCB unit, evoprator unit, remote unit and filters etc suitable for existing 1.5/2.0 ton capacity Split type Air conditioner complete all as specified and directed.make : Voltas/LG/Blustar/Carrer |
| 32 | M&L for replacemet of PCB unit of any type indoor/outdoor unit of inverter type split AC of existing make and type 1.5 Ton, 2 Ton capacity all as directed. |
| 33 | Repairs to voltage stabilizer of capacity 3/4/5 KVA incl replacement of relays,PCB boards, transformer, LEDs complete all as specified |
| 34 | S&F voltage stabilizer of capacity 5 KVA for split AC 1.5/2.0 Ton capcaty complete all as specified and directed |
| 35 | S&F in replacement of complete outdoor unit suitbale for existing indoor unit, 3 star rated IDU with complete fittings like condenser assembly, fan motor with blade, Compressor, condensor, running/ starting capactors and complete outer body suitable for existing 1.5/2.0 ton capacity Split type Air conditioner complete all as specified and directed. make : Voltas/LG/Blustar/Carrer |
| 36 | Supply and replacement ofPVC insulated and PVC Round Sheathed, Copper Conductorof size three core 1.5sqmm for desert cooler complete all as specified |
| 37 | Supply and replacement of insulation kit of copper tubing refrigerent pipe of suction and discharge including sleeves for split AC 1.5 / 2.0 Ton including PVC sheathed copper cable of size three core 2.5 sqmm for split AC complete all as specified. |
| 38 | Material and labour for replacement of unserviceable UPVC conduit pipe 20mm dia to drain out pipe including all accessories and taking down the existing one, with fixing arrangment on wall, ceiling etc.,complete all as specified and directed. |
| 39 | Supply and replacement ofPVC insulated and PVC Round Sheathed, Copper Conductor of size three core 4.0 sqmm complete all as specified |
| 40 | Supply and replacement of SheetMetal single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 240 Volts, 20 amps capacity all as specified. |
| 41 | M&L for taking out condenser/ evaporator unit of refrigerator of any capacity and rectifiy leakage/ blockage of refrigerant and refixing the same after carryout necessary repairs complete all as specified and directed. |
| 42 | Repairs tobody of water cooler of any size including denting, cutting worn out portion ofbody and replacing withMS sheet of same guage including necessay welding etc complete all as specified. |
| 43 | Disconnect electrical connection, removing copper line, discharge line of split type AC up to 2.0 Ton capacity including indoor and out door units and all accessories and shifting/reinstalling and testing the whole unit of split type AC in new location and making the holes in walls complete all as specified. |
| 44 | Servicing/cleaning of split type/window type Air conditioners, of any capacity with chemical acid complete indoor and outdoor unit all as directed and specified by Engineer-in-charge |
| 45 | Repairing ,Servicing / Cleaning of Desert Coolers of any capacity / any make complete all as directed and specified by Engineer-in-Charge Note: Any consumable items will be measured and paid seperately |
| 46 | Spray painting with two coats of synthetic enamel paint over a coat of red oxide primerto desert coolers body complete all as specified |
| 47 | Supply and replacment of 4 MFD capacitor complete all as specified. |
| 48 | Supply and replacment of desert cooler front side metal grills of suitable size/make as per sample complete all as specified. |
| 49 | Supply and replacment of water lifting pump 20Watt, 240 V, Single phase submersible type (plastic body) suitable for Desert coolers |
| 50 | Supply and replacment of wood wool cool pad 15mm thick (minimum) of required size for side & back panel of coolers (set of three) all as directed. |
| 51 | Supply and replacment of Fan motor 230 Volts, 50Hz, three speed of existing make and capacity complete all as specified and directed. |
| 52 | S&F in replacement of fan blade of metal body, set of three suitable for desert cooler motor of any sweep complete all as specified and directed. |
| 53 | Taking out and dismantling the fan motor from desert cooler, incl cleaning the stator, rewinding with super enamelled winding wire of existing size & gauge including using high quality winding wire including necessary insulation with leathoroid sheet varnishing for winding of coil, making proper insulation etc including cleaning the rotor & the stator, overhauling lubricating with fresh grease, assembling including testing commissioning complete all as specified and directed |
| 54 | S&F in replacement water storage tank made of 20 SWG GI sheet suitable for existing size of desert cooler complete all as specified and directed. |
| 55 | S&F in replacement of complete steel body with fixing arrengement of fan motor of desert cooler suitable for exisitng size duly painted with two coats of synthetic enamel paint over a coat of red oxide primer externally and one coat of anti-corrosive paint internally complete all as specified & directed.. The body of desert cooler shall be fabricated as under:- (a)Top and bottom shall be made out of 20 SWG GI sheet.(b) Side Panels shall be made of 20 SWG GI sheet.(c)Front grill shall be of suitable size and approved quality. |
| 56 | S&F in replacement side grill (set of three for three side) made of 20 SWG GI sheet as per existing type and size suitable forexisting size of desert coolers complete all as specified and directed. |
| 57 | S&F in replacement flexible PVC pipe set complete for distribution of water of desert cooler (having droping elbow -3 Nos, distribution 3 way ) as per existing size, including clamping by screw/strip all as specified and directed. |
| 58 | Supply and fix rotary selector switch of three position to control the fan motor of desert cooler of any size/capacity complete all as specified and directed |
| 59 | Supply and fix switches used to control of water pump for desert cooler of any size/capacity complete all as specified and directed |
| 60 | Supply and Charging of refrigerant R-22 /410A/32 gas including cost of welding leak detection and refitting the same in entire system,for 1.5 ton and 2.0 ton window/split AC all as specified and as directed. |
| 61 | Supply and charging of refrigerant gas R-22/ R-134A including cost of welding, leak detection, rectification in the entire system , testing and commissioning of water coolers of 40/80 ltrs, 60/120 ltrs and 150 ltrs capacity all as specified and as directed. |
| 62 | Supply and charging of refrigerant 134A including cost of welding, leak detection, rectification in the entire system , testing and commissioning of refrigerator and deep freezer of capacity upto 320 ltrs all as specified and as directed. |
| 63 | Supply and replacement of plug top 3 pin, 16 Ampscomplete all as directed by Engr-In Charge. |
| 64 | Supply and replacement of plug top 3 pin, 6 Ampscomplete all as directed by Engr-In Charge. |
| 65 | Servicing/Cleaning ofRO plant and minor repair of capacity upto 25 Ltr/Hr and any make complete all as directed and specified by Engineer-in-Charge(Note :unserviceable parts measured and paid separately) |
| 66 | S&F in replacementRO Membrane suitable for water purifier of capacity upto 25 Ltr/hr of any make complete all as specified and directed |
| 67 | S&F in replacement Diaparagm Booster Pump |
| 68 | S&F in replacementhigh/low pressureswitch |
| 69 | S&F in replacement solenoid valves24 V DC |
| 70 | S&F in replacement Faucets/Faucets adapters |
| 71 | S&F in replacementsediments filter |
| 72 | S&F in replacement carbon filter |
| 73 | S&F in replacement Pre-filter suitable for 10\" long housing |
| 74 | Servicing/Cleaning ofRO plant and minor repair of capacity 50 Ltr/Hr and any make complete all as directed and specified by Engineer-in-Charge(Note :unserviceable parts measured and paid separately) |
| 75 | S&F in replacementRO Membrane suitable for water purifier of capacity 50 Ltr/hr of any make and any type complete all as specified and directed |
| 76 | S&F in replacement Diaparagm Booster Pump |
| 77 | S&F in replacementhigh/low pressureswitch |
| 78 | S&F in replacementsolenoid valves24 V DC |
| 79 | S&F in replacement Faucets/Faucets adapters |
| 80 | S&F in replacement sediments filter |
| 81 | S&F in replacement carbon filter |
| 82 | S&F in replacement Pre-filter suitable for 20\" long housing |
| 83 | S&F in replacement pipe 1/4\" & 3/8\" dia to suit water purifier of any make/ any capacity |
| 84 | S&F in replacement water taps of existing typefor water purifier of any make / any capacity . |
| 85 | S&F in replacementSS ball valve 1/4\" / 1/2\" of existing typefor water purifier of any make / any capacity. |
| 86 | S&F in replacement fitting dead plug, dead plug bottom tank, hex nut for water purifier or any make/ any capacity |
| 87 | S&F in replacement copper pipe 1/4\",1/2\"\",1/3\"\", and all suitable size for split AC unit of any make/ any capacity |