Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-04-2025 | AMNDT | Other | 10-05-2025 |
| Sl. No. | Item Description |
| 1 | M & L for Repair/ Maint, Servicing of Diesel engine generating set of capacity5 KVA of Make:- Kirloskar, 1500 RPM,Air cooled/Water cooled consisting of the following works:-(a) Replacement of all Filters, Lubricating Oil.(b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings(c) Carry out necessary Tappet Clearance, if required.(d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins.(e) Check functioning of Changing Alternator.(f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required.(g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required.(h) The Governor shall be Checked and Tuned for Proper Functioning.(j) Check for Leaks if any and shall be rectified.(k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues.NOTE : (a) Replacement of Consumable Items such as Distilled Water, Lube Oil, Grease etc are deemed to be included in the unit quoted rate. (b) All Other Spare Parts (Quantitites mentioned under supply only items here-in-after are Provisional only) and will be Measured & Paid seperately as \"Supply only\" under appropriate Items. Labour element for the same shall deemed to be included in the unite quoted rate) |
| 2 | All as per serial item No. 01 above but for 15 KVA DG set complete ditto |
| 3 | All as per serial item No. 01 above but for 20 KVA to 25 KVA DG set complete ditto |
| 4 | All as per serial item No. 01 above but for 30 KVA to 40 KVA DG set complete ditto |
| 5 | All as per serial item No. 01 above but for 62.5KVA/63 KVA to 82.5 KVA DG set complete ditto |
| 6 | All as per serial item No. 01 above but for 100 KVA to 125 KVA DG set complete ditto |
| 7 | All as per serial item No. 01 above but for 100 KVA to 160 KVA DG set complete ditto |
| 8 | Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 5 KVA complete all as specified and as directed. |
| 9 | Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 5 KVA complete all as specified and as directed. |
| 10 | Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 5 KVA complete all as specified and as directed. |
| 11 | Supply only AVR (as per existing/ as approved) suitable for DG Set 5 KVA complete all as specified and as directed. |
| 12 | Supply only Controler (as per existing/ as approved) suitable for DG Set 5 KVAcomplete all as specified and as directed. |
| 13 | Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 15 KVA complete all as specified and as directed. |
| 14 | Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 15 KVA complete all as specified and as directed. |
| 15 | Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 15 KVA complete all as specified and as directed. |
| 16 | Supply only AVR (as per existing/ as approved) suitable for DG Set 15 KVA complete all as specified and as directed. |
| 17 | Supply only Controler (as per existing/ as approved) suitable for DG Set 15 KVAcomplete all as specified and as directed. |
| 18 | Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 20 KVA to 25 KVA complete all as specified and as directed. |
| 19 | Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 20 KVA to 25 KVA complete all as specified and as directed. |
| 20 | Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 20 KVA to 25 KVA complete all as specified and as directed. |
| 21 | Supply only AVR (as per existing/ as approved)suitable for DG Set 20 KVA to 25 KVA complete all as specified and as directed. |
| 22 | Supply only Controler (as per existing/ as approved) suitable for DG Set 20 KVA to 25 KVA complete all as specified and as directed. |
| 23 | Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 30 KVA to 40 KVA complete all as specified and as directed. |
| 24 | Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 30 KVA to 40 KVA complete all as specified and as directed. |
| 25 | Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 30 KVA to 40 KVA complete all as specified and as directed. |
| 26 | Supply only AVR (as per existing/ as approved)suitable for DG Set 30 KVA to 40 KVA complete all as specified and as directed. |
| 27 | Supply only Controler (as per existing/ as approved) suitable for DG Set 30 KVA to 40 KVA complete all as specified and as directed. |
| 28 | Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 62.5 KVA/63 KVA to 82.5 KVA complete all as specified and as directed. |
| 29 | Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 62.5 KVA/63 KVA to 82.5 KVAcomplete all as specified and as directed. |
| 30 | Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 62.5 KVA/63 KVA to 82.5 KVAcomplete all as specified and as directed. |
| 31 | Supply only AVR (as per existing/ as approved)suitable for DG Set 62.5 KVA/63 KVA to 82.5 KVAcomplete all as specified and as directed. |
| 32 | Supply only Controler (as per existing/ as approved) suitable for DG Set 62.5 KVA/63 KVA to 82.5 KVAcomplete all as specified and as directed. |
| 33 | Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 100 KVA to 125 KVA complete all as specified and as directed. |
| 34 | Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 100 KVA to 125 KVAcomplete all as specified and as directed. |
| 35 | Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 100 KVA to 125 KVAcomplete all as specified and as directed. |
| 36 | Supply only AVR (as per existing/ as approved)suitable for DG Set 100 KVA to 125 KVA complete all as specified and as directed. |
| 37 | Supply only Controler (as per existing/ as approved) suitable for DG Set 100 KVA to 125 KVA complete all as specified and as directed. |
| 38 | Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 160 KVA complete all as specified and as directed. |
| 39 | Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 160 KVA complete all as specified and as directed. |
| 40 | Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 160 KVA complete all as specified and as directed. |
| 41 | Supply only AVR (as per existing/ as approved)suitable for DG Set 160 KVA complete all as specified and as directed. |
| 42 | Supply only Controler (as per existing/ as approved) suitable for DG Set 160 KVA complete all as specified and as directed. |
| 43 | Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 5 to 15 KVA capacity, complete all as specified and as directed. |
| 44 | Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 25 to 82.5 KVA capacity, complete all as specified and as directed. |
| 45 | Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 100 to 160 KVA capacity, complete all as specified and as directed. |
| 46 | Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 5 to 15 KVA capacity, complete all as specified and as directed. |
| 47 | Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 25 to 40 KVA capacity, complete all as specified and as directed. |
| 48 | Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 62.5 to 82.5 KVA capacity, complete all as specified and as directed. |
| 49 | Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 100 to 160 KVA capacity, complete all as specified and as directed. |
| 50 | Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set upto 30 KVA complete all as specified and as directed. |
| 51 | Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 40 KVA to 160 KVA complete all as specified and as directed. |
| 52 | Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 5 KVAto 160 KVA complete all as specified and as directed. |
| 53 | Supply only V Belt (as per existing/ as approved) suitable for DG Set 5 KVA to 40 KVA complete all as specified and as directed. |
| 54 | Supply only V Belt (as per existing/ as approved) suitable for DG Set 62.5 KVA/63 KVA to 160 KVA complete all as specified and as directed. |
| 55 | Dismantling the alternator of 5 KVA to 15 KVA DG Set from its position after disconnecting all electric connections with help of chain pulley, removing the bearing with the help of bearing puller and shifting the alternator to authorised workshop for repair and servicing complete checking of connections, terminals, lugs, tightening of connections, replacement of bushes, making good copper coil winding if burnt complete and refixing again its own position and proper alingment complete all as specifed and directed by the Engr-in-Charge. (Note: (a) Winding materials of copper coil with insulation materials shall be measured and paid seperately as Supply only. Labour element for re-winding shall deemed to be included in the unit quoted rate (b) Minor spare requireded for smooth functioning of alternator shall be provided by the contractor without any extra cost to the Govt) |
| 56 | Dismantling the alternator of 20 KVA to 63 KVA DG Set from its position after disconnecting all electric connections with help of chain pulley, removing the bearing with the help of bearing puller and shifting the alternator to authorised workshop for repair and servicing complete checking of connections, terminals, lugs, tightening of connections, replacement of bushes, making good copper coil winding if burnt complete and refixing again its own position and proper alingment complete all as specifed and directed by the Engr-in-Charge. (Note: (a) Winding materials of copper coil with insulation materials shall be measured and paid seperately as Supply only. Labour element for re-winding shall deemed to be included in the unit quoted rate (b) Minor spare requireded for smooth functioning of alternator shall be provided by the contractor without any extra cost to the Govt) |
| 57 | Dismantling the alternator of 82.5 KVA to 160 KVA DG Set from its position after disconnecting all electric connections with help of chain pulley, removing the bearing with the help of bearing puller and shifting the alternator to authorised workshop for repair and servicing complete checking of connections, terminals, lugs, tightening of connections, replacement of bushes, making good copper coil winding if burnt complete and refixing again its own position and proper alingment complete all as specifed and directed by the Engr-in-Charge. (Note: (a) Winding materials of copper coil with insulation materials shall be measured and paid seperately as Supply only. Labour element for re-winding shall deemed to be included in the unit quoted rate (b) Minor spare requireded for smooth functioning of alternator shall be provided by the contractor without any extra cost to the Govt) |
| 58 | Supply only Super Enamel Copper Winding Wires with Proper Guage Rewinding of Alternator/Armature etc Coils of any Capacity with Double Paper covering, conforming to IS:7404 (Part-I) : 1991 (as per existing Size, Turns and Insulation Class) including All Insulation Materials, Gasket, etc., suitable for 415 Volt Alternator complete all as specified and as directed. |
| 59 | Dismantling the Exciter Field armature assembly of 5 KVA to 15 KVA DG Set from ites existing position after after disconnecting all electric connections with help of chain pulley, removing the bearing with the help of bearing puller and shifting the armature to authorised workshop for repair and making good copper coil winding if burnt and servicing, complete checking of connections, terminals, lugs, tightening of connections, replacement of bushes complete and refixing again its own position and proper alingment and testing complete all directed by the Engr-in-Charge. (Note: (a) Winding materials of copper coil with insulation materials shall be measured and paid seperately as Supply only. Labour element for re-winding shall deemed to be included in the unit quoted rate (b) Minor spare requireded for smooth functioning of armature shall be provided by the contractor without any extra cost to the Govt) |
| 60 | Dismantling the Exciter Field armature assembly of 20 KVA to 40 KVA DG Set from ites existing position after after disconnecting all electric connections with help of chain pulley, removing the bearing with the help of bearing puller and shifting the armature to authorised workshop for repair and making good copper coil winding if burnt and servicing, complete checking of connections, terminals, lugs, tightening of connections, replacement of bushes complete and refixing again its own position and proper alingment and testing complete all directed by the Engr-in-Charge. (Note: (a) Winding materials of copper coil with insulation materials shall be measured and paid seperately as Supply only. Labour element for re-winding shall deemed to be included in the unit quoted rate (b) Minor spare requireded for smooth functioning of armature shall be provided by the contractor without any extra cost to the Govt) |
| 61 | Dismantling the Exciter Field armature assembly of 62.5 KVA/63 KVA to 82.5 KVA DG Set from ites existing position after after disconnecting all electric connections with help of chain pulley, removing the bearing with the help of bearing puller and shifting the armature to authorised workshop for repair and making good copper coil winding if burnt and servicing, complete checking of connections, terminals, lugs, tightening of connections, replacement of bushes complete and refixing again its own position and proper alingment and testing complete all directed by the Engr-in-Charge. (Note: (a) Winding materials of copper coil with insulation materials shall be measured and paid seperately as Supply only. Labour element for re-winding shall deemed to be included in the unit quoted rate (b) Minor spare requireded for smooth functioning of armature shall be provided by the contractor without any extra cost to the Govt) |
| 62 | Dismantling the Exciter Field armature assembly of 100 KVA to 160 KVA DG Set from ites existing position after after disconnecting all electric connections with help of chain pulley, removing the bearing with the help of bearing puller and shifting the armature to authorised workshop for repair and making good copper coil winding if burnt and servicing, complete checking of connections, terminals, lugs, tightening of connections, replacement of bushes complete and refixing again its own position and proper alingment and testing complete all directed by the Engr-in-Charge. (Note: (a) Winding materials of copper coil with insulation materials shall be measured and paid seperately as Supply only. Labour element for re-winding shall deemed to be included in the unit quoted rate (b) Minor spare requireded for smooth functioning of armature shall be provided by the contractor without any extra cost to the Govt) |
| 63 | S & F in repair heavy duty synthetic insulation mat of size 2mx1mx2.5mm thick conforming to IS:15652-2006 suitable for 1100 Volts, ISI marked complete all specification and directed. |
| 64 | Disconnecting & Dismounting of Self Starter, 12 Volts from the Engine of DG Set 5 KVA to 63 KVA, Transporting to nearest Authorised Workshop for Repairing, Replacement of Unservicable Parts, Servicing Complete, Transporting the same from Workshop to Site of Work and Re-fixing with DG Set, Testing, complete all as specified and as directed. (Note: Minor spare requireded for smooth functioning of starter shall be provided by the contractor without any extra cost to the Govt) |
| 65 | Disconnecting & Dismounting of Self Starter, 12 Volts from the Engine of DG Set 82.5 KVA to 160 KVA, Transporting to nearest Authorised Workshop for Repairing, Replacement of Unservicable Parts, Servicing Complete, Transporting the same from Workshop to Site of Work and Re-fixing with DG Set, Testing, complete all as specified and as directed. (Note: Minor spare requireded for smooth functioning of starter shall be provided by the contractor without any extra cost to the Govt) |
| 66 | S & F in repair Battery 12 Volt, 150 AH (as approved) and Providing all Electrical Connection complete all as specified and as directed.(MAKE : EXIDE XPRESS/LUMINOUS/AMRON) |
| 67 | S & F in repair Battery 12 Volt, 100 AH (as approved) and Providing all Electrical Connection complete all as specified and as directed.(MAKE : EXIDE XPRESS/LUMINOUS/AMRON) |
| 68 | S & F in repair Battery copper lead with brass clamp and nuts & bolts of any type and capacity DG Set as per site requirement (as per existing/ as approved) and connected complete all as specified and as directed. |
| 69 | S & F in repair Battery Terminal of Copper/Brass (as per existing/ as approved) and connected complete all as specified and as directed. |
| 70 | S & F in repair Oil Safety Control (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up complete all as specified and as directed. |
| 71 | S & F in repair Solenoid Switch Assembly (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up complete all as specified and as directed. |
| 72 | S & F in repair Water Safety Control (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up complete all as specified and as directed. |
| 73 | S & F in repair Water Temperature Gauge (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting upcomplete all as specified and as directed. |
| 74 | S & F in repair Toggle Switch 3-way, Double Pole (as per existing/ as approved) and connectedcomplete all as specified and as directed. |
| 75 | S & F in repair Injector Nozzle for 25 to 63 KVA DG Set (as per existing/ as approved) as per site requirementcomplete all as specified and as directed. |
| 76 | S & F in repair Injector Nozzle for 100 to 160 KVA DG Set (as per existing/ as approved) as per site requirementcomplete all as specified and as directed. |
| 77 | S & F in repair Diodes in any type and for any capacity of DG Set (as per existing/ as approved) as per site requirementcomplete all as specified and as directed. |
| 78 | S & F in repair Digital Battery Charger of 100 to 150 AH suitable for Charging Battery 12 Volt and Providing All Electrical Connections as required for BatteryCharging and Removing old Battery Charger to AGE E/M Store Yard and deposited complete all as specified and as directed. |
| 79 | Supply & Filling Coolant for Radiators as approved complete all as specified and as directed.(MAKE : KIRLOSKAR or equivalent Make as approved by GE) |
| 80 | Supply & Filling Engine Oil 20 W/ 40 Grade as approved, complete all as specified and as directed.(MAKE : CASTROL CRB PLUS or equivalent Make as approved by GE) |
| 81 | M & L for Cleaning of Radiator of any Capacity after Opening all Nuts, Bolts, etc. by dismounting, Re-mounting after Cleaning with Chemical and Tightening of Nuts, Bolts, etc. including Straightening of Radiator Fins with suitable Tools, complete all as specified and as directed. |
| 82 | M & L for Repairing & Cleaning of Diesel Tank with suitable Materials after disconnecting Fuel Line, Opening of all Nuts, Bolts, etc., Re-fixing the same after satisfactory Repairing including necessary Welding (if required), etc., complete all as specified and as directed. |
| 83 | M & L for Disconnecting all Electrical Cable Connection from the Dynamo Assembly and Taking down the Dynamo Assembly for Carry out Repairs and Complete Overhauling the System including Replacing the Unserviceable Parts like Carbon Bushes, Bearings, Armature, Burnt out coils, etc., Re-assambling & Re-fixing the Dynamo Assembly to Original Position and re-connecting all Electrical Cable Connections & Testing for DG Set 5 KVA to 15 KVA of MAKE : ASHOK LEYLAND/ KIRLOSKAR, complete all as specified and as directed. |
| 84 | M & L for Disconnecting all Electrical Cable Connection from the Dynamo Assembly and Taking down the Dynamo Assembly for Carry out Repairs and Complete Overhauling the System including Replacing the Unserviceable Parts like Carbon Bushes, Bearings, Armature, Burnt out coils, etc., Re-assambling & Re-fixing the Dynamo Assembly to Original Position and re-connecting all Electrical Cable Connections & Testing for DG Set 20 KVA to 40 KVA of MAKE : ASHOK LEYLAND/ KIRLOSKAR, complete all as specified and as directed. |
| 85 | M & L for Disconnecting all Electrical Cable Connection from the Dynamo Assembly and Taking down the Dynamo Assembly for Carry out Repairs and Complete Overhauling the System including Replacing the Unserviceable Parts like Carbon Bushes, Bearings, Armature, Burnt out coils, etc., Re-assambling & Re-fixing the Dynamo Assembly to Original Position and re-connecting all Electrical Cable Connections & Testing for DG Set 62.5 KVA to 160 KVA of MAKE : ASHOK LEYLAND/ KIRLOSKAR, complete all as specified and as directed. |
| 86 | S & F in repair MCCB 415 Volt, 36 KA, 4 Pole, 250 Ampscapacity, adjustable thermal (80%-100%) , (Ics=100% of Icu) complete all as specified and as directed. |
| 87 | S & F in repair MCCB 415 Volt, 36 KA, 4 Pole, 400 Ampscapacity, adjustable thermal (80%-100%) , (Ics=100% of Icu) complete all as specified and as directed. |
| 88 | S & F in repairOn Load Change Over Switch (Front Operated) Open Execution, current rating 100 Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. |
| 89 | S & F in repairOn Load Change Over Switch (Front Operated) Open Execution, current rating 160 Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. |
| 90 | S & F in repairOn Load Change Over Switch (Front Operated) Open Execution, current rating 200 Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. |
| 91 | S & F in repairOn Load Change Over Switch (Front Operated) Open Execution, current rating 250 Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. |
| 92 | S & F in repairOn Load Change Over Switch (Front Operated) Open Execution, current rating 320 Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. |
| 93 | S & F in repairChange Over Switch (side handle operated) in sheet metal enclouser, current rating 32 Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. |
| 94 | S & F in repairChange Over Switch (side handle operated) in sheet metal enclouser, current rating 63 Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. |
| 95 | S & F in repairOn Load Change Over Switch (side handle operated) in sheet metal enclouser, current rating 100 Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. |
| 96 | S & F in repairOn Load Change Over Switch (side handle operated) in sheet metal enclouser, current rating 200 Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. |
| 97 | S & F in repairOn Load Change Over Switch (side handle operated) in sheet metal enclouser, current rating 320 Amps,4 pole, 415 V, 50 Hzcomplete all as specified and directed. |
| 98 | Supply, Install, Commissioning and testing LT cubical type feeder pillar Panel, CPRI approved factory made, outdoor type, made out of 3.15mm thick CRCA sheet, Dust and vermin proof, weather proof with front operared double door type and rear single door shutter with seperate hinge door with locking arragnement, totally enclosed type including PCC 1:2:4, Type B-1 foundation of suitable size,415 Volts, 3 pahse, 4 wire, AC 50 Cycles per second having Aluminium bus bar insulated mounted on porcelain insulator and suitable double compression copper cable gland and internal wiring with copper conductor cable complete including taking down/dismantling existing panel board all as specified and directed comprising with the following items:(i) MCCB 250 Amps, 4 pole, 36 KA, 415 Volts, Adjustable thermal and magnetic release:- 01 No(ii) MCCB 160 Amps, 4 pole, 36 KA, 415 Volts, Adjustable thermal and magnetic release:- 01 No(iii) MCCB, 4 pole, 100 Amp, 16 KA, 415 Volts, Adjustable thermal and magnetic release:- 02 No(iv) Digital mulktifunction meter with 03 Nos CT of 20/5 A - 01 Set(v) LED pahse indicator lamp (RYB) with fuse link - 01 Set of 3(vi) Bus bar 4 strip, Aluminium of capacity 500 Amps strip TPN of suitable size - 01 Set(vii) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs(Note: (i) Panel shall be of factory made and CPRI approved(ii) External terminals with tinned copper has to be provided for trmming the incoming and outgoing cables with suitable lugs of MCB (if required)(iii) Necessary excavation and earth work for foundation shall deemed to be included in the unit quoted rate) |
| 99 | Supply, Install, Commissioning and testing LT cubical type feeder pillar Panel, CPRI approved factory made, outdoor type, made out of 3.15mm thick CRCA sheet, Dust and vermin proof, weather proof with front operared double door type and rear single door shutter with seperate hinge door with locking arragnement, totally enclosed type including PCC 1:2:4, Type B-1 foundation of suitable size,415 Volts, 3 pahse, 4 wire, AC 50 Cycles per second having Aluminium bus bar insulated mounted on porcelain insulator and suitable double compression copper cable gland and internal wiring with copper conductor cable complete including taking down/dismantling existing panel board all as specified and directed comprising with the following items:(i) MCCB 250 Amps, 4 pole, 36 KA, 415 Volts, Adjustable thermal and magnetic release:- 02 No(ii) MCCB 160 Amps, 4 pole, 36 KA, 415 Volts, Adjustable thermal and magnetic release:- 01 No(iii) MCCB, 4 pole, 100 Amp, 16 KA, 415 Volts, Adjustable thermal and magnetic release:- 02 No(iv) On load Changeover switch 4 pole, 250 A : 01 No(v) Digital mulktifunction meter with 03 Nos CT of 20/5 A - 01 Set(vi) LED pahse indicator lamp (RYB) with fuse link - 01 Set of 3(vii) Bus bar 4 strip, Aluminium of capacity 1000 Amps strip TPN of suitable size - 01 Set(viii) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs(Note: (i) Panel shall be of factory made and CPRI approved(ii) External terminals with tinned copper has to be provided for trmming the incoming and outgoing cables with suitable lugs of MCB (if required)(iii) Necessary excavation and earth work for foundation shall deemed to be included in the unit quoted rate) |
| 100 | S & F in repairFuel pump assembly, 1500 RPM, supply pressure of fuel 4.5 to 5.5 PSI as per IS: 4113 as per the existing make and model as approved suitable for 125 KVA DG Set and connecting up complete all as specified and directed. |
| 101 | M & L for Fuel Pump calibration, measure the exact mount, position of the injection pumps, plunger with dial guage and adjust the injection timing accordingly set the injection system timing with timing light and fuel delivery to each cylinder during engine combustion cycle of any capacity of pump complete all as directed by the Engr-in-Charge |
| 102 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking down/up existing unserviceable cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately) |
| 103 | All as per Serial item No. 102 above but for 120 Sqmm 3.5 Core cable complete ditto |
| 104 | All as per Serial item No. 102 above but for 70 Sqmm 3.5 Core cable complete ditto |
| 105 | All as per Serial item No. 102 above but for 50 Sqmm 3.5 Core cable complete ditto |
| 106 | All as per Serial item No. 102 above but for 35 Sqmm 3.5 Core cable complete ditto |
| 107 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depthfor foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 108 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. |
| 109 | Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting pointcomplete all as specified and directed. |
| 110 | M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed.(Note: Thickness after punning down shall be measured for payment) |
| 111 | Supply and laying locally available best quality, well burnt sub class B bricks (old size), laid dry in trenches for protection of UG cables complete all as specified and directed. |
| 112 | M & L earthing with copper earth plate electrode 600 mm x 600mm x 3.15 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with copper earth strip of size 20x3mm by means of bolts, nuts,check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. |
| 113 | M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy