| 1 | Earth work in Excavation in trenches for foundation, pipes ,cables etc. in ordinary soil (Loam clay or sand) including lift upto 1.5 m.,lead upto 30m. And dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer.Desilting, Dredging, Deeping in pond including 1.5 mt. lift and 30 mt. lead with all. |
| 2 | Clearing jungle including uprooting of vegetation grass,bush,wood trees upto 30 cm. measured at a height of 1 metre above ground level and removal of rubush upto a distance of 50 m outside the perophery of area cleared. |
| 3 | Earth work in cutting or in filling in ordinary soil excavation to be in the form of regular pits not exceeding 1/2 metre 20\" in depth andd earthwork in embankment to be in 20 cm layers including ramming and dressing the surface to required level and slopes and also including 1.5 metre lift and 30 m lead the earth from cutting to be used in making filling or to be deposited as spoil bank within 30 metres distance as directed by engineer in charge. |
| 4 | Sand filling in plinth in plinth with sand under floor ,including watering, ramming, consolidating and dressing complete. |
| 5 | Cement concrete with 4 cm gauge approved stone ballast approved coaarse sand and cement in the proportion of 1:4:8 incluning supply of all materials labour and T&P etc. required for proper completion of the work |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 7 | providing and laying Autoclaved Aerated Concrete (AAC)/Autoclaved Concrete (ACC) blocks masonary 100mm/ 125mm tthick with Grade 1AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 in super structure above plinth level up to floor V level in cement mortar 1:4. the rate includes providing and placing in positing 2 Nos.6 mm Dia M.S. Bars At every third course of masonry work. |
| 8 | half brick masonry with common burnt clay FPS bricks of class designation 7.5 in superstructure above plinth level up to floor v level. |
| 9 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) |
| 10 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form work. |
| 12 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 13 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 14 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form work. |
| 16 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONALanti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration |
| 17 | 15 mm thick cement plaster 1:6 in two coats work in external plaster |
| 18 | 12 mm thick cement plaster 1:4 in internal plaster |
| 19 | Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm,which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). |
| 20 | Providing and laying Marble stone flooring with 18 mm thick, rissers of steps ,skirting ,dado 10 mm thick in base of cement mortar 1:4 laid over jointed with grey cement slurry mixed with pigment to match the shade of slab including polishing complete. |
| 21 | Providing and laying kota slab 20 mm flooring, rissers of steps ,skirting ,dado 10 mm thick in base of cement mortar 1:4 laid over jointed with grey cement slurry mixed with pigment to match the shade of slab including polishing complete. |
| 22 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 23 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 24 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 25 | Finishing wall with water proofing cement paint of approved make and quality on new work with two coat give an even shade. |
| 26 | Providing and fixing 1 mm thick MS sheet garage door with frame of 40 x 40 x 6 mm angle iron 3.15 thick ms gusset plates at the juncton corners including supply and fixing of necessary fitting complete all as per direction of Engineer-in-charge. |
| 27 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 28 | Providing and fixing ball bearingfor rolling shutter |
| 29 | Supply and fixing in position collapsible steel shutter with vertical channels 20 x 10 x 2 mm & braced with flat iron diagonals 20 x 5 mm size without and bottom rails steel pulleys with bolts , nuts locking arrangements ,stoppers ,handles complete including applying a primimg coat of approved red lead paint. |
| 30 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings :(Flat back wash basin of size 550x400 mm) |
| 31 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 32 | White glazed earthenware european type wc pan with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fitting and ci brackets 40 mm flush bend overflow arrangement with specials of standard make it complete. |
| 33 | Providing anf fixing 8 mm dia C.P/ S.S jet with Flexible tube upto 1 metre long with S.S triangular plate to european type WC of Quality and make as approved by Engineer in charge. |
| 34 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittingsand fixtures complete.10 litre capacity - range of four urinals basins with white PVC automatic Flushing Cistern. |
| 35 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 36 | providing and fixing toilet paper holder |
| 37 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 38 | Providing and fixing C.P. brass angle valve of approved quality conforming to IS:8931 : |
| 39 | Providing and fixing in position 100mm dia sand cast iron S&S pipe as per IS :1729 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.Providing and fixing of bend of required degree with access door |
| 40 | Providing and fixing ofplain bend of required degree |
| 41 | Providing and fixing ofcollar |
| 42 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm |
| 43 | Providing, Laying , fixing soil, waste and vent pipes 100mm dia sand cast iron S&S pipe as per IS :1729 jointing and testing complete as per specifications.(100mm o/d pipe ) |
| 44 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : |
| 45 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects.Inside size 75x120 cm and 120 cm deep |
| 46 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.CPVC SDR 11 Pipe & fitting 20mm o/d |
| 48 | CPVC SDR 11 Pipe & fitting 25mm o/d |
| 49 | CPVC SDR 11 Pipe & fitting 32mm o/d |
| 50 | Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect.(Boring with 300 mm id Housing Pipe,Upto 150 m depth BGL.(EACH BOARING)) |
| 51 | Supplying, lowering of PVC Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.CPVC SDR 11 Pipe & fitting 20mm o/d |
| 52 | CPVC SDR 11 Pipe & fitting 25mm o/d |
| 53 | Providing and fixing Submersible Pump 2 HP |
| 54 | Cement concrete with 4 cm gauge approved stone ballast approved coaarse sand and cement in the proportion of 1:4:8 incluning supply of all materials labour and T&P etc. required for proper completion of the work |
| 55 | Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : |
| 56 | Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint ofany colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :100 mm diameter pipe |
| 57 | Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group C) |
| 58 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 59 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired.2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 60 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 61 | Painting or Varnishing on iron works in small areas or new wood work with two coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials, labour and T&P etc. required for proper completion of the work. Paint to be used should confirm to the I.S.I.No. 103 195020 mm |
| 62 | 25 mm |
| 63 | 32 mm |
| 64 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 65 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 66 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 67 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.Module (100mmX75mm) |
| 68 | 12 Module (200mmX150mm) |
| 69 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 510 MM Sweep |
| 70 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 71 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.(62 A TP&N) |
| 72 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole |
| 73 | Triple pole and neutral |
| 74 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.(63 A) |
| 75 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipeof 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 76 | Add 18% GST |