| 1 | Supply of steel tubular pole swaged type as per IS:2713-1980 complete with base plate and top Canopy 410 SP-44 - 10.00 metreSOR P/131, I/42.3.15 |
| 2 | Erection of RS Joist pole/\"H\" beam/steel tubular/steel rail pole of length 7 metres but not exceeding 10 metres in cement concrete 1:3:6 (1 cement : 3 core sand: 6 graded stone aggregate 40mm nominal size) base, foundation, muffing including excavation and back refilling etc. as required.Sor P/134, I/42.19 |
| 3 | Dismantling of existing steel pole, R.S. Joist, girder with bracket clamp insulator or stay from the cement concrete foundation and making the site clear by refilling the pit to ground level i/c transportation to required destination within township.Sor P/85, I/35.9 |
| 4 | Prima coat over new steel and other metallic surface with red oxide zinc chromide paint complete with supply of material labour etc. including preparation of surface. Sor P/84, I/34.4.2 |
| 5 | Prima coat with aluminium paint, brushing complete with material and labour including preparation of surface. Sor P/84, I/34.4.3 |
| 6 | Supplying and installing double wall corrugated pipes (DWC) of HDPE (IS 14930 Part II -marked) for cable laid underground with necessary material and at required depth upto 90 cm. below road/ground surface, excluding excavation, back filling with excavated material, ramming and making the surface good. 50.00mm outside dia.For High Mast, SOR P/123, I/41.14.1 |
| 7 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor. 4 core armoured16 sq. mm(Make :- Vishal, RR Kabel, LS cable, PYMEN, V-Marc , Paraflex, Polycab, Primecab, Gloster, Unistar.)Sor P/114, I/41.1.10.3For High Mast |
| 8 | Laying of one number armoured / unarmoured power cable 1.1KV grade of size not exceeding 25 sq. mm direct in ground including excavation in all soil/ murrum /soft rock, sand cushioning, protective covering and refilling the pit etc. as required. Sor P/123, I/41.15.1For High Mast |
| 9 | Supply and fixing of multi core round FRLSH PVC insulated copper (flexible) conductor & PVC sheathed cables 1100Volts as per IS:694-1990 of approved makeThree core 1.5 sq.mm. (30/0.25 mm) Three core 1.5 sq.mm. SOR P/65, I/29.6.3 |
| 10 | Supply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF> 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job.90Watt, color temp 3000-6500k as required.Sor P/77, I/31.13.3 |
| 11 | Supplying and erection of water tight terminal box made of PC-GFS (polycarbonate),IP 66 /IP 67 (cable entry systems LES) in accordance with IEC 60670-22, resistant to weather influences (UV due to solar radiation, protected against rainwater, temperature resistant, impact resistant, etc. insulation voltage 1000 V a.c./d.c., wall thickness of the bottom part 2 / 2.7 mm of required size suitable for kit kat/MCB/switch including 2 nos. pole clamp of M.S. flat iron size 32x3mm, nut and bolts, excluding the cost of the kit kat/MCB/Switch, 4 Pole epoxy connector nut & bolt type, 30Amp, 500Volt complete as per specification as mentioned below. |
| 12 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of \"C\" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :-27.8.1 Single pole 27.8.1.2 MCB SP 6A to 32A, 10kA MCB SP 6Amp to 32Amp 10kA rating.MCB SP 6Amp to 32Amp 10kA rating. Sor P/56, I/27.8.1.2 |
| 13 | Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only) 28.4.1MCB/Isolator SP/DPSor P/63, I/28.4.1 |
| 14 | Supplying and fixing crimping type alum. lugs as per I.S.S. specification suitable for following size of cable with alu./copper solid/stranded conductor evenly crimped with high/pressure tool and connected to switch gear/bus/M.C.C.B./M.C.B. etc. as required complete.6 -16 sq. mmFor conductor size- 6mm to 16 sq. mm Sor P/118, I/41.7.1 |
| 15 | Earthing with G.I. earth pipe 4.5 metre long and 40 mm dia with masonry encloser in cement mortar, cover plate having lockingarrangement on the top etc. (but without charcoal or coke and salt) complete as required. Sor P/88, I/37.1 |
| 16 | Lettering with black Japan paint of approved brand and manufacture. Building Sor P/481, I/13.78. |
| 17 | Designing & casting of open raft shallow footing foundation with M-20 cement concrete suitable for 16meter high mast considering the safe soil bearing capacity at site as 10 T/sqm at 2meter depth including excavation, foundation nut bolts in an approved manner as per manufacturer drawing or engineer-in- charge Sor P/150, I/42.109 |
| 18 | Add extra for using salt and charcoal/coke for pipe earth electrode as required including excavation & refillingExcavation 4.5 m by manual labour Sor P/88, I/37.2.1 |
| 19 | Supply and laying 4.87mm 6 SWG G.I. wire at 0.5 metre below ground level as conductor earth electrode including jointing etc. as required. Sor P/89, I/37.8. |
| 20 | Providing and erection on existing foundation 16 meter high mast lighting system suitable to install upto 8 No. 2 x 250/ 400 w M.H/S.V/LED flood light and control gear with integral power tool, weight 450 kg. comprising of 2 sections of hot dipped galvanized materials as per BSEN ISO 1461 thickness 3 mm & 4 mm, dia 150mm & 360mm for top and bottom respectively, stress fitting arrangement on site with 500mm overlap dynamic loading to withstand max wind pressure as per -IS 875 part III, parameters for structural & foundation design must be taken from wind tunnel test. Lightning protection of GI single spike 1200mm at top and at base inside compartment having double internal lock with adequate size of MCB erected on PVC board complete with base plate of 25mm thick 520mm dia. and foundation bolts having 6 nos. bolts of 24mm dia 750 mm long (EN.8 grade) anchor plate 445 PCD, including accessories viz.(1) Lantern carriage of 50 NB ERW class-B, MS pipe covered with PVC sleeve suitable to carry 500kg. load and upto 8 fittings symmetrically.(2) Trailing copper cable 5x2.5 sq.mm, PVC insulated PVC Sheathed(3) Double drum 350Kg Winch having gear 53:1, oil bath (SAE90/140) arrangement. (4) 2 nos. Stainless steel wire ropes 5 mm dia (7/19) breaking load capacity 1450 kg x 2,. (5) Integral power tool 3-phase, 0.75HP 2m/min singlespeed .torque limiter upto 500 kg adjustable(6) Single LED 300 Nos. aviation light(7) Feeder pillar fabricated out of 14 SWG CRCA sheet and comprise of incoming MCB 32 A TPN switch, HRC fuses, single dial timer, suitable size of contactors for lighting and power tool, 2 nos. outgoing, reversing switchfor motor.(8) Foundation drawing, test certificate and guarantee certificate shall be provided by manufacturer. (without fixture and lampSor P/146, I/42.96 |
| 21 | Supplying and fixing flood light with high power LED of 3 to 6 Watt each assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF > 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire,testing etc. to complete the job.250Watt, color temp 3000-6500k as required. Sor P/77, I/31.14.8 |
| 22 | Supply and fixing of multi core round FRLSH PVC insulated copper (flexible) conductor & PVC sheathed cables 1100Volts as per IS:694-1990 of approved makeThree core 2.5 sq.mm.(50/0.25 mm) Three core 2.5 sq.mm. Sor P/65, I/29.6.4 |