| 1 | M&L for servicing and maintenance of split type AC\"s of capacity1.5 TR/ 2.0 TR comprising of the following works & installed at different locationsincluding testing, painting of outdoor unit including writting MES Nos with black synthetic enamel paint (height of letters not less than 10mm) on indoor and outdoor unit complete all as specified and directed :-(i) Checking and rectifying the Indoor/outdoor units for noise free operation.(ii) Checking and rectifying the electrical connection for tightness.(iii) Cleaning the Out-door unit condenser andIn-door unit cooling coil with air blower and latest technology cleaning system.(iv) Greasing/Oiling of condenser fan motor and blower motor.(v) Checking and rectifying for any kind of refrigerant leakage.(vi) Checking the serviceability of remote control unit.Note:- (i) Any parts found unserviceable/defective rectified/changed shall be measured and paid separately under respectively item (here-in-after) of BOQ. (ii) Make of parts shall be as per original & Genuine make of AC.(iii) Make(s) of AC\"s to be repaired are specified in Appx \"B\". (iv) Providing Common tools, Special Tools, latest cleaning devices and Connected accessories is the responsibility of contractor. |
| 2 | All as per Srl Item No 1.00(here-in-before) but for Vertical/Tower type AC\"s of capacity 3.0 TR complete all as specified and directed. |
| 3 | All as per Srl Item No 1.00(here-in-before) but for VRF 18.0 TR AC (Outdoor Unit - One, Inverter, R410A refrigerant gas. Indoor Units - Seven, Roof suspended Concealed inside False ceiling)complete all as specified and directed. |
| 4 | S&F in renewal of running capacitor 45 mfd for split type AC unit as per existing as required at Site complete all as specified and directed. |
| 5 | S&F in renewal of running capacitor combo 50+6 mfd for split type AC\"s of capacity 1.5/2.0 TR complete all as specified and directed. |
| 6 | S&F in renewal of indoor blower fan motor, single phase, 230 Volt of split type AC Suitable for 1.5 TR capacity complete all as specified and directed. |
| 7 | S&F in renewal of indoor blower fan motor, single phase, 230 Volt of split type AC Suitable for 2.0 TR capacity complete all as specified and directed. |
| 8 | S&F in renewal of burnt compressor of capacity 1.5 TR of split type AC unit and re-fixing the same after renewal from the company make original compressor as per existing Make & Model of rotary type including gas charging complete all as specified and directed.Note :-(i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the unit quoted rate.(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same. |
| 9 | S&F in renewal of burnt compressor of capacity 2.0 TR of split type ACs unit and re-fixing the same after renewal from the company make original compressor as per existing Make & Model of rotary type including gas charging complete all as specified and directed.Note :-(i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the unit quoted rate.(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same. |
| 10 | M&L for repair to leaking area of split type AC unit of capacity 2.0 TRincluding dehydration, gas charging of gas R22/R410A/R-32 as applicable, pressure check & testing complete all as specified and directed.Note :-(i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the unit quoted rate.(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same. |
| 11 | M&L for repair to leaking area of split type AC unit of capacity 1.5 TRincluding dehydration, gas charging of gas R22/R410A/R-32 as applicable, pressure check & testing complete all as specified and directed.Note :-(i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the unit quoted rate.(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same. |
| 12 | S&F in renewal of air filter of indoor unit for split type AC units of capacity 1.5/2.0 TR as per existing Make & Model complete all as specified and directed. |
| 13 | S&F in renewal of insulation for Split AC Copper Tube 5/8 inch with Nitrile rubber insulation tube of OD thickness 10mm and length 6 ft per piece(minimized heat gain and loss, Good condensation control) followed with clamps complete all as specified and directed. |
| 14 | S&F in renewal of insulation for Split AC Copper Tube 1/2 inch with Nitrile rubber insulation tube of OD thickness 10mm and length 6 ft per piece (minimized heat gain and loss, Good condensation control) followed with clamps complete all as specified and directed. |
| 15 | S&F in renewal of insulation for Split AC Copper Tube 1/4 inch with Nitrile rubber insulation tube of OD thickness 10mm and length 6 ft per piece (minimized heat gain and loss, Good condensation control) followed with clamps complete all as specified and directed. |
| 16 | S&F in renewal of 3 core copper PVC insulated FRLSH cable of size 4.0 Sqmm, flexible cables, 1100 Volts and confirming to IS: 694 complete all as specified and directed. |
| 17 | S&F in renewal of swing motor of indoor unit as per existing Make & model for split type AC, 1.5 TR complete all as specified and directed. |
| 18 | S&F in renewal of swing motor of indoor unit as per existing Make & model for split type AC, 2.0 TR complete all as specified and directed. |
| 19 | S&F in renewal of suction line (1/4\") copper pipe or suitable size as per existing dia and length with Nitrile Rubber protection as required at site complete all as specified and directed. |
| 20 | S&F in renewal of discharge line (5/8\") copper pipe or suitable size as per existing dia and length with Nitrile Rubber protection as required at site complete all as specified and directed. |
| 21 | S&F in renewal of discharge line (1/2\") copper pipe or suitable size as per existing dia and length with Nitrile Rubber protection as required at site complete all as specified and directed. |
| 22 | Disconnecting and repair to PCB of split AC of capacity 1.5/2.0 TR and refixingthe same including testing complete all as specified and directed. |
| 23 | S&F in renewal of PCBs indoor/ outdoor units as per existing Make & model for Split type AC of Capacity 2.0 TR/ 1.5 TR complete all as Specified and directed. |
| 24 | S&F in renewal of PCBs indoor/ outdoor units as per existing Make & model for vertical type AC of Capacity 4.0 TR complete all as Specified and directed. |
| 25 | S&F in renewal of electronic cordless remote control unit as per existing Make & model of split type AC\"s of capacity 1.5/2.0 TR complete all as specified and directed. |
| 26 | S&F in renewal of Flexible PVC drain pipe of size 15mm bore & suitable for Split type AC of Capacity 1.5/2.0 TR complete all as specified and directed. |
| 27 | S&F in renewal of outdoor unit fan blade clock/anti clock wise rotation as per existing Make and model suitable for Split type AC of Capacity 1.5 TR complete all as Specified and directed. |
| 28 | S&F in renewal of outdoor unit fan blade clock/anti clock wise rotation as per existing Make and model suitable for Split type AC of Capacity 2.0 TR complete all as Specified and directed. |
| 29 | S&F in renewal of outdoor unit condenser fan motor as per existing Make & model suitable for 1.5 TR capacity air conditioner complete all as specified and directed. |
| 30 | S&F in renewal of outdoor unit condenser fan motor as per existing Make & model suitable for 2.0 TR capacity air conditioner complete all as specified and directed. |
| 31 | S&F in renewal of indoor unit complete set (Refrigerant Compatibility R22, R410A & R-32) with & including cordless remote, compatable with all BEE Star Ratings AC\"s, copper tubes in evaporator coil as per existing Make & model & suitable for 1.5 TR capacity air conditioner and including gas charging complete all as specified and directed. Note :-(i) Cost of Refrigerant gas (R-22/R-410A/R-32) deemed to be included in the unit quoted rate.(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same. |
| 32 | S&F in renewal of indoor unit complete set (Refrigerant Compatibility R22, R410A & R-32) with & including cordless remote, compatable with all BEE Star Ratings AC\"s, copper tubes in evaporator coil as per existing Make & model & suitable for 2.0 TR capacity air conditioner and including gas charging complete all as specified and directed. Note :-(i) Cost of Refrigerant gas (R-22/R-410A/R-32) deemed to be included in the unit quoted rate.(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same. |
| 33 | S&F in renewal of outdoor unit (Refrigerant Compatibility R22, R410A & R-32) without compressor, Compressor compatibility; Rotary or Reciprocating both as per existing Make & model & suitable for 1.5 TR capacity air conditioner and including gas charging complete all as specified and directed. Note :-(i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate.(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same. |
| 34 | S&F in renewal of outdoor unit (Refrigerant Compatibility R22, R410A & R-32) without compressor, Compressor compatibility; Rotary or Reciprocating both as per existing Make & model & suitable for 2.0 TR capacity air conditioner and including gas charging complete all as specified and directed. Note :-(i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate.(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same. |
| 35 | S&F in renewal of copper condenser coil as per existing and suitable for 1.5 TR capacity of air conditioner, outdoor unit, ISI marked and including gas charging complete all as Specified and directed. Note :-(i) Cost of Refrigerant gas (R-22/R-410A/R-32) deemed to be included in the unit quoted rate.(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same. |
| 36 | S&F in renewal of copper condenser coil as per existing and suitable for 2.0 TR capacity of air conditioner, ISI marked and including gas charging complete all as Specified and directed. Note :-(i) Cost of Refrigerant gas (R-22/R-410A/R-32) deemed to be included in the unit quoted rate.(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same. |
| 37 | S&F in renewal of Low pressure valve as per existing Make & model of size 1/4 & 1/2 inch, ISI marked complete all as specified and directed. |
| 38 | S&F in renewal of Low pressure valve as per existing Make & model of size 5/8 inch, ISI marked complete all as specified and directed. |
| 39 | S&F in renewal of four way valve as per existing Make & model and suitable for 2.0 TR / 1.5 TR capacity of air conditioner, ISI marked complete all as specified and directed. |
| 40 | S&F in renewal of AC refrigerant charging Pin NRV Valve ISI marked complete all as specified and directed. |
| 41 | S&F in renewal of wall mounted outdoor metal bracket of size 36 inch of heavy duty of minimum weight 5.50 Kg and Load capacity of 50 kgs for outdoor unit of split AC\"s 1.5/2.0 TR capacity with & including connected accessories viz fastner, nuts and boltscomplete all as specified and directed. |
| 42 | M&L forshifting of Split/vertical type AC\"s of capacity 1.5 to 4.0 TR with indoor, outdoor including all connected accessories after pumping down the gas and , refitting, topping up the gas, testing and commissioning complete all as specified and directed. |
| 43 | S&F in renewal of self adhesive nitrile rubber insulation sheet with silver foil coated(9mm thick) for duct insulation package type air conditioner complete all as specified and directed. |
| 44 | S&F in renewal of brass flare nut 5/8 inch for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC complete all as specified and directed. |
| 45 | S&F in renewal of brass flare nut 1/2 inch for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC complete all as specified and directed. |
| 46 | S&F in renewal of brass flare nut 1/4 inch for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC complete all as specified and directed. |
| 47 | M&L for repair & maintenance of water coolers of capacity 40/80 Ltrs comprising of the following works at different location and including painting and writing MES Nos with black synthetic enamel paint (height of letters not less than 10mm) complete all as specified and directed :-(i)Inspection, taking down, opening, dismantling, descaling, brushing & cleaning of storage tanks.(ii) Examination water tightness, leak proof of storage tank after cleaning.(iii) Carry out operation of all stop cock, push cock, float valve etc.(iv) Inspect overflow and remove blockage if any.(v) Check and correct earth continuity of electric items.(vi) Check thermostat and test its functioning.(vii) Inspect drain pipe and remove blockage if any.(viii) Check and correct all electrical wiring & test its functioning.(ix) Testing of water cooler after repair.Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respectively item (here-in-after) of BOQ. (ii) Make of parts shall be as per original make of water coolers.(iii) Make(s) of water cooler to be repaired are all as specified in Appx \"B\". |
| 48 | All as per Srl Item No 47.00(here-in-before) but for water coolers of capacity 60/120 Ltrs complete all as specified and directed. |
| 49 | S&F in renewal of thermostat switch as per existing Make & Model for water cooler of any Capcity complete all as specified and directed. |
| 50 | S&F in renewal of overload protector relay as per existing Make & Model for compressor of water cooler of any capacity as reqd at site complete as specified and directed. |
| 51 | S&F in renewal of condenser fan motor, single phase of 1/30 HP as per existingMake and Model & suitable for water cooler of capacity 40/80 Ltrs complete all as specified and directed. |
| 52 | S&F in renewal of condenser fan motor, single phase of 1/20 HP as per existingMake and Model & suitable for water cooler of capacity 60/120 Ltrs complete all as specified and directed. |
| 53 | S&F in renewal of 15mm bore brass float valves accessories as per existing Make and Model & suitable for water coolers at site, ISI marked complete all as specified and directed. |
| 54 | Disconnecting and taking down water coolers of capacity 40/80 Ltrs & 60/120 Ltrs of any make and size for repairs & including detection of leakage in the system rectifying the same, dehydration & recharging of gas (R-22/R-134A/Environmental Friendly Gas) suitable for compressor model & testing the water cooler for smooth & satisfactory operation complete all as specified and directed.Note :-(i) Cost of Refrigerant gas (R-22/R-134A/Environmental Friendly Gas) shall be deemed to be included in the unit quoted rate.(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same. |
| 55 | S&F in renewal of CP push cock of size 15mm dia as per existing Make & model, ISI marked complete all as specified and directed. |
| 56 | S&F in renewal of capacitor 10 Mfd as per existing Make & model, ISI marked for water cooler of any capacity complete all as specified and directed. |
| 57 | S&F in renewal of burnt compressor as per existing original Make & model and suitable for water cooler of capacity 40/80 or 60/120 Ltrs and including gas charging complete all as specified and directed.Note :-(i) Cost of Refrigerant gas (R-22/R-134A/Environmental Friendly Gas) shall be deemed to be included in the unit quoted rate.(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same. |
| 58 | M&L for repair & maintenance of Refrigerator of capacity 180 Ltrs to 340 Ltrs comprising of the following works at different location and writting MES Nos with black synthetic enamel paint (height of letters not less than 10mm) complete all as specified and directed :-(i) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil.(ii) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts.(iii) Inspecting the leakage in the system.(iv) Checking of the earth continuity of electrical parts.(v) Checking the functioning of thermostat.(vi) Inspection of all electrical parts.(vii) Testing the machine for satisfactory operation.(viii) Check and correct all electrical wiring & test its functioning.(ix) Testing of Refrigerator after repair.Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respectively item (here-in-after) of BOQ. (ii) Make of parts shall be as per original make of Refrigerator.(iii) Make(s) of Refrigerators to be repaired are specified in Appx \"B\". |
| 59 | S&F in renewal of burnt compressor as per existing Company Make original & model and suitable for refrigerator of capacity 165-190 Ltrs and including gas charging complete all as specified and directed.Note :-(i) Cost of Refrigerant gas (R-134A/Environmental Friendly Gas) shall be deemed to be included in the unit quoted rate.(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same. |
| 60 | S&F in renewal of burnt compressor as per existing Company Make original & model and suitable for refrigerator of capacity 200-340 Ltrs and including gas charging complete all as specified and directed.Note :-(i) Cost of Refrigerant gas (R-134A/Environmental Friendly Gas) shall be deemed to be included in the unit quoted rate.(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same. |
| 61 | Disconnecting and taking down refrigerator (165 to 320 Ltrs Cap) of any make and size for repairs & including detection of leakage in the system rectifying the same, dehydration & recharging of gas (R-134A/ Environmental Friendly Gas) & testing the refrigerator for smooth & satisfactory operation complete all as specified and directed.Note :-(i) Cost of Refrigerant gas (R-134A/Environmental Friendly Gas) shall be deemed to be included in the unit quoted rate.(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same. |
| 62 | M&L for repair & maintenance of Deep Freezer of capacity 200 to 350 Ltrs comprising of the following works at different location and including writting MES Nos with black synthetic enamel paint (height of letters not less than 10mm) complete all as specified and directed :-(i) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil.(ii) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts.(iii) Inspecting the leakage in the system.(iv) Checking of the earth continuity of electrical parts.(v) Checking the functioning of thermostat.(vi) Inspection of all electrical parts.(vii) Testing the machine for satisfactory operation.(viii) Check and correct all electrical wiring & test its functioning.(ix) Testing of Refrigerator after repair.Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respectively item (here-in-after) of BOQ. (ii) Make of parts shall be as per original make of Deep freezer.(iii) Make(s) of Deep Freezer to be repaired are specified in Appx \"B\". |
| 63 | S&F in renewal fan motor of deep freezer 16 watts, 230 Volts single phase complete all as specified and directed |
| 64 | S&F in renewal of burnt compressor as per existing Company Make original & model and suitable for deep freezer of capacity 200-350 Ltrs and including gas charging complete all as specified and directed.Note :-(i) Cost of Refrigerant gas (R-134A/Environmental Friendly Gas) shall be deemed to be included in the unit quoted rate.(ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same. |
| 65 | S&F in renewal Refrigerator 1/2 HP, 3/8 HP, 1/3 HP compressor start relay complete all as specified and directed. |
| 66 | S&F in renewal Refrigerator relay capacitor 5 to 12 mfd complete all as specified and directed. |
| 67 | M&L for repair / servicing of existing voltage stabilizer incuding replacement of transformer, volt meter, switch, cord wire with plug top on off indication lamp out put socket of capacity upto 05 KVA complete all as specified and directed. Note:- (a) Minor item / spares parts deemed to be included in the unit quoted rate & not to be paid separtely . |
| 68 | S&F in renewal of single pole and neutral sheet metal enclosure with a two pin and earth plug and socket and including one MCB SPN 20 Amp, 240 Volt, MCB, \"C\" curve type with AC box, rupturing capacity 10 KA complete all as specified and directed. |
| 69 | S&F in renewal of MCB single pole 6 to 32 Amp,\"C\" curve having rupturing capacity 10 KA conforming to IS-8828-1996,IEC-60898, complete all as specified & directed. |
| 70 | S&F in renewal of metal clad plug 2P+E for all type of AC\"s as per existing Make and size complete all as specified & directed. |
| 71 | S&F in renewal of metal clad socket 2P+E for all type of AC\"s as per existing Make and size complete all as specified & directed. |
| 72 | S&F in renewal of AC Changeover Guard ATM Timer (Response time 16 ms) should prevent Low Voltage start, having Compressor Lockout/ Anti-Short Cycle timer, Should eliminate relay xchatter due to thermostat bounce or tampering complete all as specified & directed. |
| 73 | S&F in renewal of outdoor fan motor of VRF AC capacity 18 TR as per existing Make and size complete all as specified and directed. |
| 74 | S&F in renewal of outdoor unit PCB of VRF AC capacity 18 TR as per existing Make and size complete all as specified and directed. |