Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), including disposing off the retrieved debris outside the premises, complete all as specified and as directed. |
| 2 | M& L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) of approved size, area of eachtile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed inwhite cement mixed with pigments to match with the shade of tiles, over and including 20mm thick screed bed in CM (1:6), complete all as specified and as directed. |
| 3 | M& L for coloured Non - skid Ceramic coloured tiles 7 to 8 mm thick , area of eachtile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirting/Vertical surface etc. set and jointed in neat cement slurry and pointed inwhite or coloured cement mixed with pigments to match with the shade of tiles, over and including 10mm thick in cement morter (1:3) complete all as specified and as directed. |
| 4 | M&L for coloured Glazed ceramic tiles of size 300mmx 450mm , 6 to 7 mm thick on the vertical surfaces such as in skirting / dado etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with the shade of the tiles, over and including 10mm thick cement mortal backing coat in CM (1:3), complete all as specified andand as directed. |
| 5 | Dismantling of stone slabs and tiles laid beddedand pointed in any mortar of any description or thickness in floors, aprons etc., complete all as specified and as directed. |
| 6 | M&L for granite (of any type)20mm thick (Table rubbled and polished ) insteps, jambs, pillars, window-cills, cooking platform etc, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including 20mm thick screed bed in CM (1:4), including necessary dismantling of floor tiles complete all as specified and directed. |
| 7 | M&L for granite (of any type)20mm thick (Table rubbled and polished ) in for wall lining b(veneering to wall)etc, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including 12mm thick screed bed in CM (1:3), including necessary dismantling of floor tiles complete all as specified and directed. |
| 8 | Demolition of cement concrete (un-reinforced )in ground floors and pavings n exc 15 cm thickness (below or above ground level)including disposing off the retrieved debris outside the premises, complete all as specified and as directed. |
| 9 | M&L for providing 75mm thick PCC (1:3:6) type (C2) (using 40mm graded crushed stone aggregate), as in plinth protection, surface finished even & smooth without using extra cement including provision of 10 mm joints (at an interval of 3 metre and turnings) duly filled with fine sand and bitumen in the ratio of (3:1), complete all as specified and directed. |
| 10 | M&L for r providingand laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 11 | M&L forPCC 75 mm thick (1:4:8) type (D2) (using 40mm graded crushed stone aggregate), as in sub base of floor/path/etc.complete all as specified and directed. |
| 12 | M&L forPCC (1:4:8) type (D2) (using 40mm graded crushed stone aggregate), as in sfoundation filling mass concretecomplete all as specified and directed. |
| 13 | M & L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and as directed. |
| 14 | M&L for Plain cement concrete( 1:3:6) type (C-2) (using 40mm graded crushed stone aggregates) as in surface channel and drain, including from work complete all as specified and as directed. |
| 15 | Roughening surfaces of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust etc and brushingneat cement slury with 3kg/sqm, complete all as specified and as directed. |
| 16 | M&L for 20 to 25mm thick Machine cut kota stone slabsas in flooring,treads over & including 20mm thick screed in cm (1:6), set, jointed and pointed in neat cement slurry mixed with pigment to match with the shade of the slabs, including rubbing and mirror polishing etc, complete all as specified and as directed. |
| 17 | M&L for 20 to 25mm thick Machine cut kota stone slabsas in riser of step, skirting, dado etc. laid over and including 10mm thick backing layerin cm (1:4), set, jointed and pointed in neat cement slurry mixed with pigment to match with the shade of the slabs, including rubbing and mirror polishing etc, complete all as specified and as directed . |
| 18 | M & L for rounding to edges of stone slabs one edge such as in steps, cooking platform and similar situations. Complete all as specified and as directed . |
| 19 | Demolition of brick work or rubbled stone masonry including all quoins, arches , pillars etc built in cement mortar including disposing off the retrieved debris outside the premises, complete all as specified and as directed. |
| 20 | M & L in Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM(1:6) complete all as specified and as directed. |
| 21 | All as peritem no 20 but except brickin CM(1:6) complete all as specified and as directed. |
| 22 | M & LBrickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius in half brick walls in CM1:6 complete including dismantaling /demolation of existing all as specified and as directed. |
| 23 | M & L in Brickwork with subclass ‘B’ bricks, one brick thick honey comb walling built inin CM(1:4) complete all as specified and as directed. |
| 24 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description & in any position not otherwise specifically provided for including disposing off the retrieved debris outside the premises, complete all as specified and as directed. |
| 25 | M & L for RCC (1:2:4) (using 20mm grededstone aggregate) Type B1(Nominal mix) as in landings cover slabs(for man holes et) chullah hoods, chajjas,water trughs, mangers,shelves and similar articles with plain faces and set in CM (1:4) complete all as specified and as directed. |
| 26 | M & L for RCC (1:2:4) (using 20mm grededstone aggregate) Type B1(Nominal mix) as in las slabs supported on walls ,beams and columns in floors , roof landings, balconies canopies complete all as specified and as directed. |
| 27 | M & L for RCC (1:1/1.5:3) (using 20mm grededstone aggregate) Type B1(Nominal mix) in beams cantilevers bressummers, lintels over 1.5 m spancomplete all as specified and as directed. |
| 28 | M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips etc, complete all as specified and as directed. |
| 29 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, chajjas landings and similar work, not exceeding 200mm thick (horizonal or slopping) for rough finished flat surfaces of concrete, complete all as specified and as directed. |
| 30 | M&L for cement concrete (1:3:6) type, C1 (using 20mm graded crushed stone aggregates) as in copings, be block for filling hollow space of steel chowkhats, fixing of hold fast,kneelers, apex stones, bed plates water troughs and like etc, including necessary formwork, weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed. |
| 31 | Demolition ofcement concrete (un-reinforcement) of any description & in any position not otherwise specifically provided for including disposing off the retrieved debris outside the premises, complete all as specified and as directed. |
| 32 | M & L 10mm thick cement plaster in CM (1:4)using WPC @2% by wt of cement in sunken poartioncomplete all as specified and as directed.Note:- WPC shall be measured and paid seperately. |
| 33 | M & l for Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. m and then pasting of polythene film ,150 micron thick laid on a coat of bitumen primer @ 0.30 to 0.50 kg par sqm complete all as specified and as directed. |
| 34 | M & L PCC (1:3:6) type C-2 (using 40mm graded trap stone aggregate) as in Masslean concrete or similar work incl WPC poartioncomplete all as specified and as directed. |
| 35 | M & L 40 mmthick PCC (1:2:4) Type B-1 as in flooringetccomplete all as specified and as directed. |
| 36 | M & L 25 mmthick PCC (1:2:4) Type B-1 as in sunken porationetc complete all as specified and as directed. |
| 37 | M & L 15mm thick cement plaster in CM (1:3)using WPC @3% by wt of cement in sunken poartioncomplete all as specified and as directed.Note:- WPC shall be measured and paid seperately. |
| 38 | M & L PCC (1:4:8) type E-2 (using 40mm graded trap stone aggregate) as in Masslean concrete , sunken poration or similar work incl WPC poartioncomplete all as specified and as directed. |
| 39 | Taking down chowkats or frames with Wooden/PVC/Flush shutters (without taking off shutter from frames) not exc. 1.5 sqm each, including cutting holes for removing the hold fast etc,disposing off the retrieved debris outsite the premises, complete all as specified and as directed. |
| 40 | Taking down chowkats or frames with Wooden/PVC/Flush shutters (without taking off shutter from frames) exc. 1.5 Sqm but n exc 4 Sqm each, including cutting holes for removing the hold fast etc,disposing off the debris outsite the premises, complete all as specified and as directed. |
| 41 | S&F factory made 1.25 mm thick pressed steel frame of size 125 X 60 mm for doors with one or more rebates including necessary provision of lugs, locks strike plate, hinges etc, applying one shop coat of Zinc Chromate primer after prepation of the surfaces,complete all as specified and as directed. |
| 42 | S&F factory made 1.25 mm thick pressed steel frame of size 105 X 60 mm for doors with one or more rebates including necessary provision of lugs, locks strike plate, hinges etc, applying one shop coat of Zinc Chromate primer after prepation of the surfaces,complete all as specified and as directed. |
| 43 | S&F 30mm thick flush shutter solid core construction, with block boardcore and plywood face panels,commercial type on both sides complete all as specified and as directed. |
| 44 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube,complete all as specified and shown on drawing for SI No. 08095 on Srl Page No. 180 of SSR (Part-II) and as directed. |
| 45 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement,,complete all as specified and shown on drawing for SI No. 08080on Srl Page No. 176 of SSR (Part-II) and as directed. |
| 46 | M&L for 2nd class hard wood (Hollock/Kalasiris/Brjsal/Gamari) (kiln seasoned and chemically pressure treated) 30 mm thick glazed and skeleton shutters,open rebated and prepared to rceieve glass, gauze, etc, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, sizes of members of shutters as specified in SSR Part-1, Section 8, clause 8.24 (a), complete all as specified and as directed. |
| 47 | S & F Steel windows with side hung shutters including box type type hinges with steel handle, and steelpeg stay, complete with glazing bars, dovetailed orcomplete all as specified and as directed. |
| 48 | S & F Steel windows with side hung shutters including box type type hinges with steel handle, and steelpeg stay, complete without glazing bars, dovetailed orcomplete all as specified and as directed. |
| 49 | S & F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed. |
| 50 | S&F 3mm thick sheet glass ofordinary qualityand glazing for with oil putty , in squaresn.exc 0.50 sqm in each pane, complete all as specified and as directed. |
| 51 | S&F 4mm thick frosted/pin headed glass of in ventilator shutters, complete all as specified and as directed. |
| 52 | S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width ofaperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and as directed. |
| 53 | S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, complete all as specified and as directed. |
| 54 | S&F 100mm size butt hinges,extrued aluminium alloy with galvanised MS sheet hinges pin anodised , complete all as specified and as directed. |
| 55 | S&F Aluminium anodised barrel towerbolt, 150 mm long of extruded section, complete all as specified and as directed. |
| 56 | S&F150 mm size aluminium handle, cast type, anodised, complete all as specified and as directed. |
| 57 | S&F in repair mild steel helical door spring 300mm long, ordinary rat tail rod pattern springs including roller and roller plate fixed with screw to wooden frame or with welding to steel frame, complete all as specified and as directed. |
| 58 | S&F in repair floor door stopper 150mm (overall length of cover plate) of aluminium alloy body and tongue, anodised, with hardrawn steel spring, fixed in floor, complete all as specified and as directed. |
| 59 | S&F in repair 25mm bore harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc.,complete all as specified and directed. |
| 60 | M&L for mild steel comprising of the angle iron, flat iron etc using steel conforming to Fe-290 Gde E-165 as in hold fast and similar articles , complete all as specified and as directed. |
| 61 | Dismantling wrought iron or mild steel work of any description in any position etc, complete all as specified and as directed. |
| 62 | M&L for the Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165, complete all as specified and as directed. |
| 63 | S&F mild steel rolled sections [Fe 410-W (Gde E-250) quality - B] as in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc manhole cover slab . (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and as directed. |
| 64 | S&F hard drawn steel wire fabric (weight not exc.4kg/Sqm) fixed in tank caging,cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia, complete all as specified and directed. |
| 65 | M&L for 2nd class hard wood forPlain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specifiied and directed. |
| 66 | M&L for prelaminated particle board 12mm thick, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, complete all as specified and as directed. |
| 67 | M&L for prelaminated particle board 18/19mm thick, interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, complete all as specified and as directed. |
| 68 | S & F Hasp and staple, aluminium anodised 100mm safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed. |
| 69 | S & F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and complete all as specified and as directed. |
| 70 | M&L for 2nd class hard wood plain filletsrectangular in section ,wrought fixd with nails exc 6 sqcm but n exc 13 sqcm complete all as specified and as directed. |
| 71 | S & F 40mmContinuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and as directed. |
| 72 | S&F100 mm size aluminium handle, cast type, anodised, complete all as specified and as directed. |
| 73 | S&F in repairs 600x 450mmbevelled edge mirror of decorative type, selected qualitymounted on and including 6 mm thick commercial plywood and provision of wooden plugs with chromium plated brass screws and cup washers for fixing, complete all as specified and as directed. |
| 74 | S&F stainless steel kitchen plate rack of overall approx size 24’’ x 36’’ x 10’’,complete all as specifiied and directed. |
| 75 | S&F 15mm bore medium grade, galvanized steel tubing (including in short lengths) with and including all fittings, fixed partly on the surfaces and partly concealed in thewalls & ceiling or laid in floors, also including taking down complete all as specified and as directed. |
| 76 | S&F 20mm bore medium grade, galvanized steel tubing (including in short lengths) with and including all fittings,and including taking down complete all as specified and as directed. |
| 77 | M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing, etc., and making good, cutting not exc 10 cm girth, complete all as specified and as directed. |
| 78 | S&F in repairs bib tap, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule of 15 mm bore, complete all as specified and as directed. |
| 79 | S&F in repairs Pillar taps with Aerator, fancy type, cast copper alloy, with long swan neck , chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe of 15mm bore, completeall as specified and as directed. |
| 80 | S&F in repairs stop valves, fancy type,cast copper alloy, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unionsof 15 mm bore,complete all as specified and as directed. |
| 81 | S&F in repairs bib tap, fancy type,two way, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule of 15 mm bore, complete all as specified and as directed. |
| 82 | S&F in repairsstop cock/angle cock , fancy type, cast copper alloy, chromium plated with crutch, screwed for iron pipe or brass ferrule of 15 mm bore, complete all as specified and as directed. |
| 83 | S&F in repairs bevelled edge mirror of decorative type, selected quality of glass mountedand including 6 mm thick AC bldg board orcommercial plywood and provision of wooden plugs with chromium plated brass screws and cup washers for fixing, complete all as specified and as directed. |
| 84 | S&F in repairs Vitreous China Wash Down Water closet (Pedestal Pattern) 1st quality,white (excluding flushing cistern & flush pipe) including plastic water closet seat white, closed pattern with flat bottom and cover and mild steel CP or aluminised huiging device, making connections, complete all as specified and as directed. |
| 85 | S&F in repairs PVC valveless, double syphonic action type, flushing cistern, low level of 10 Litres capacity, white, with and including inlet, ball valve, float, 32mm dia flush pipe of polyethylane of low or high density or PVC, flushing bend & handles, also including brackets, suitable for both Indian Type Water Closet & Europeon Type Water Closet & making connections, complete all asspecifiedand as directed. |
| 86 | S&F in repair vitreous china wash basin, 1st quality, white, flat back, approx size 550x400mmexcluding taps but including 32 mm bore brass chromium platedwaste fittings, 32mm bore PVC waste pipe,MS brackets, complete all as specified and as directed. |
| 87 | S&F in repair PVC connection 15 mm size with PTMT nuts of each end, length 600 mm, complete all as specified and directed. |
| 88 | S & Fin repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as specified and as directed. |
| 89 | S&F in repair rotational moulded polyethylene water storage tank 1000ltrs capacity, ISI marked, (cylindrical vertical type double-layered) with closed top including inlet,outlet and wash out holes, provision of G.I Fittings for fixing of the inlet, outlet and washout pipes, hoistedin position, including float valve,complete of existing dismantling all as specified and as directed. |
| 90 | S&F gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of 20 mm bore, complete all as specified and directed. |
| 91 | Taking dowm eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes bends,swan-necks, etc including cleaning or refixing or removal to store (measured overall) as fixed along the centre line over fittingscomplete all as specified and directed. |
| 92 | S & F repair PVC (SWR) pipes110mm bore single socketed, in any length with rubber ring joints, fixed in wall/ floor with access door complete all as specified and as directed. |
| 93 | S&F 110mm bore PVC (SWR) bends (any radius) with and including rubber ring with access door, complete all as specified and directed. |
| 94 | S&F 110mm bore PVC (SWR) Junction, single (single T) equal or unequal with access door,and including rubber ring joints, complete all as specified and directed. |
| 95 | S&F PVC (SWR) vent cowl, 110 mm bore, complete all as specified and directed. |
| 96 | S & F repair PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, fixed in wall with access door complete all as specified and as directed. |
| 97 | S&F 75mm bore PVC (SWR) bends (any radius) with and including rubber ring with access door, complete all as specified and directed. |
| 98 | S&F 75mm bore PVC (SWR) Junction, single (single T) equal or unequal with access door,and including rubber ring joints, complete all as specified and directed. |
| 99 | S&F PVC (SWR) vent cowl, 75 mm bore, complete all as specified and directed. |
| 100 | S &F for 75mm bore of pipe stack clamp out of 50mmx 5mm flat iron 16mm dia round iron stay including bolts and nuts and secring ends of stays to wall or roof complete all as specified and directed. |
| 101 | S &F for 100mm bore of pipe stack clamp out of 50mmx 5mm flat iron 16mm dia round iron stay including bolts and nuts and secring ends of stays to wall or roof complete all as specified and directed. |
| 102 | S & Fin repair 75 mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and directed. |
| 103 | S&F 110mm bore PVC (SWR) Junction, single (double T) equal or unequal with and including rubber ring joints, complete all as specified and directed. |
| 104 | S&F in repairs tubular towel rail, 20mm dia, D type, brass chrormium plated, 600mm long between flanges, complete all as specified and as directed. |
| 105 | S&F in repairs brass chromium plated shower roses, 125 mm size with or without swivel joints (including Shower Arms) to 15mm bore steel pipe or union, complete all as specified and as directed. |
| 106 | S&F in repair sink with drainage board made of 0.80 mm thick sheet of stainless steel (Bronze range super steel 204 : Matt) for kitchen or laboratory with and including plugs, washers, 32mm bore brass chromium plated waste fittings, 32mm bore PVC waste pipe, also including bedding in cement mortar (1:3) on dwarf wall or including providing mild steel cantilever brackets and connecting union to pipe, overall size 495mm x 462mmwith bowl size 410mmx 330mm x 160mmcomplete all as specified and as directed. |
| 107 | S&F in repairs sheet glass self fixed with chromium plated bracket guard and railing 60 cm long brass screws and cup washers for fixing, complete all as specified and as directed. |
| 108 | S&Fsoap dish, PTMT/china approximate size 160x160x90mm white fixed to wall with plugs with chromium plated brass screws, and wooden/plastic cleats complete all as specified and as directed |
| 109 | S&F in repairs corner glass self fixed with 5.5 mm thick sheet glass shelf and side not less than 225mm with chromium plated bracket guardfor fixing, complete all as specified and as directed. |
| 110 | S&F towel ring, chrormium platedfixed with plugs with chromium plated brass screws,complete all as specified and as directed. |
| 111 | M & L as in repair for roof treatment including the following :-(i) Roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.(ii) M & L for 25 mm thick Cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) incl 2% WPCas in top of roof.(iii) M & L 10 mm thick rendering on roof surfacein cement mortar 1:4 finished even and fair incl 2% WPCwithout using extra cement.(iv) Apply 2 coat of aluminium paint over APP membrane .(v) Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. m including cleaning surfaces.(vi)APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric laid on primed surface by forced application complete all as specified |
| 112 | M & L for repair of damged roof after complete removal existing treatment icl padding ,cleaning the surface using wire brush brooming down and applying the following treatment all as diercted in order or precedence as diercted. APP modified roof treatment over existing roof slab etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications, complete all as specified and directed:-(a)Rendering 15mm thick in Cm 1:4 on existing roof surface true to level after applying cement slurry @3kg/Sqm(b) Applying oil bound bitumen primer @ 0.40 litre/ Sqm manufactured by the same manufacturer as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on the prepared dry surface.(c) Laying 3mm thick APP modified water proofing polymeric membrane reinforced with non woven polyester fibre using butane torch by torchapplication with 10cm side lap and 15cm end lap. (d) Physical properties of membrane shall be as under:- (i) Membrane weight not less than 3.60 Kg/Sqm.(ii)Cold flexibility -(-) 50C.(iii) Dimentional stability % change = Maximum 1%. (ivi)Heat Resistance - Does not dirp at 1200 C(d) one coat of Aluminium paint of approved brand to be provided over the APP membrane.Note : The quoted rate shall also be deemed to include for cutting grooves of size and shape as required in the parapet wall for tackling the APP membrane in the wall including making good the surfaces of groove as well as damaged surfaces of the wall after tackling of membrane in CM 1:3 to match with the adjoining surfaces. |
| 113 | Removing and Hacking of existing deteriorated damaged & loose concrete from the external surface of the structure carefully by low impact high frequency hammer or by manual chipping without damaging the existing concrete or control sand blasting including cleaning the surfaces by air jet etc, complete and also without damaging the existing structure.The rate shall also include disposal of waste/rubble/malwa from site outside MD Land upto as directed by the Engr-in-Charge along with lead and lift if any including standard steel scaffolding upto a height of 7 M.Note : The above treatment will be done in presence of company authorised person and also company skilled workers |
| 114 | Removing the loose scale of corrosion etc from the exposed reinforcementand cleaning the corroded reinforcement by wire brush followed by cleaniong with air blower/ water jet . Finally cleaning the rusted reinforcement / metal (iron base) by Chemical rust remover , cleaning and etching agents with brush for complete wetting of rusted metal surface and allowed to react it for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal / steel for about 5-7 days. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth. as per technical specifications and also as per manufacturers recommondations and also as per directions of Engineer-in- charge. The rates inclusive of labourers, materials , tools etc complete in cluding standard steel scaffolding upto a height of 7 M. Note : The above treatment will be done in presence of company authorised person and also company skilled workers. Make of the Rust removing agent : Reebakelens RR from M/s Fosroc or Equivalent Makes M/s SIKA, M/s Pidilite etc. |
| 115 | M & L for surface cleaning and application of Two coats of Two component epoxy zinc rich primer coat on steel surfaces / reinforcement as per manufacturer\"s recommendation and as per technical specification and also as per the direction of Engr-in-Charge, complete including standard steel scaffolding upto a height of 7 M Make of Two component epoxy zinc rich primer : Nitozinc Primer from M/s FOSROC and EquivalentM/s SIKA, M/s Pidilite etc.Note : The above treatment will be done in presence of company authorised person and also company skilled workers. |
| 116 | Re-Bar Anchor: Providing and fixing shear connectors of 10 mm dia by drilling 12 mm diaholes on the concrete surface to a depth of 100 mm using a rotary cum hammering drilling machine as per technical specification and throughly cleaning the hole using compressed air and water jet and anchoring with pure Epoxy resin based anchoring grout solution.Make ofEpoxy based resin grout: LOck Fix E77from M/s FOSROC and EquivalentM/s SIKA, M/s Pidilite etc.Note : The above treatment will be done in presence of company authorised person and also company skilled workers. |
| 117 | Crack Sealing : Identify the cracks and construction joints, honeycomb areas, shall be chased open into ‘U’ groove shape and sealed with High strength, abrasion - resistance epoxy reinstatement mortar, Fosroc Nitomortar S or Equivalent, Providing and fixing 6-8mm dia nozzle along the joints and honeycomb areas after proper surface preparation. The injection of Conbextra EP10 or Equivalent through the nozzle till the refusal of the grouting materials. |
| 118 | M & L for providing and applying Structural grade long pot life, Two component Epoxy resin concrete bonding agent prior to building up of secion with any type of mortar / concrete to ensure bond between old concrete and new concrete by brush application as per manufacturers instructions and also as per technical specifications and also as directed by Engineer-in-Charge at site.Note : The above treatment will be done in presence of company authorised person and also company skilled workers.Make of Two component Epoxy resin concrete bondin agent : Nitibond EP from FOSROC or EquivalentM/s SIKA, M/s Pidilite etc. |
| 119 | M&L for 25 mm thick( Average thickness) Guniting concrete surface using mechanical means with single component, shrinkage controlled, polymer modified, fibre reinforced structural grade cementitious repair mortar having compressive strength of 45 N/ Sq.mm , Flexural strength of 7 N/Sq.mm and tensile strength of 2.50 N/sq.mm at 28 Days all as per manufacturer\"s recommendation and technical specification and as per the direction of Engr-in-Charge including standard steel scaffolding upto a height of 7 M Note : The above treatment will be done in presence of company authorised person and also company skilled workers.Make of single component, shrinkage controlled, polymer modified, fibre reinforced structural grade cementitious repair mortar : Renderoc SP 40 from FOSROC or EquivalentM/s SIKA, M/s Pidilite etc. |
| 120 | M&L for providing and laying of ready to use non shrink ,cementitious free flow micro concrete, upto required thickness at the designated areas, to the prepared slurry tight shuttering with proper shear connectors and bonding agent where ever necessary .The fluid Micro-concrete repair material shall be single component , cement based to which only site condition of water and approved graded coarse aggregate where ever specified shall be permitted . The micro concrete shall contain no mettalic aggregates or chlorides and shall be shrinkage compensated in the plastic state. The micro concrete in the flowable consistancy should achieve a compressive strength of 50 N/ Sq.mm after 28 days at 30 degrees Centigrate as per BIS 4551-80.The unrestrained expansion shall be between 1-4 % as per ASTM C827 -1987. Again as per BS 4551-80 the flexural strength shall not be less than 5 N/ Sq.mm @ 28 days. The Micro Concrte shall have a coefficient of thermal expansion 10-12 x 10 -6 /oC and thermal conductivity 1.50 W /moC . The mixed density of micro concrete shall exceed 2100-2200 Kg/Cu.M 227oC including standard steel scaffolding upto a height of 7 MNote : The above treatment will be done in presence of company authorised person and also comapany skilled workers. Make of non shrink ,cementitious free flow micro concrete micro concrete :- Renderoc RG of FOSROC or EquivalentM/s SIKA, M/s Pidilite etc. |
| 121 | Taking down cement plaster on brick or concrete surfaces etc,including raking out joints, hacking for key, scrubbing down with water etc, and also including removal of rubbish off the premises, complete all as specified and directed. |
| 122 | M & L repair to broken/demaged RCC chajjas by makinggood with 1:2:4 type B1 or cement mortar 1:3 rendering 15 mm thick mixed with water proofingcompund to top & sides and soffits in CM 1:4 including necessary form work, reinforcement duly welded if required including demolation of broken/loose PCc or taking down old plaster upto a height of 9 mtrs complete all as specified and directed. |
| 123 | M&L for rendering 15 mm thick in CM (1:4) on brick work or concrete surfaces finsihed even and smooth (without using extra cement) mixed with water proofing compound as per manufacturer instructions, complete all as specified and as directed.Note:- WPC shall be measured and paid seperately. |
| 124 | M&L for rendering 15 mm thick in cement mortar (1:6), on brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed. |
| 125 | M&L for rendering 10 mm thick on concrete surfaces as in ceiling in cement morter 1:3 forfinished even and smooth without using extra cement, complete all as specified and directed. |
| 126 | Supply only integral water proofing compound, complete all as specified and as directed. |
| 127 | M&L for preparation of newlyplastered surfaces of walls and applying two coats of wall care Putty (minimum thickness of two layers shall be 1.50mm)and thereafter applying two or more coats of 100% Premium acrylic emulsion weather coat paint @ 1.43 ltr/10 sqm (for two coats) paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additivesover and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm,complete all as specified and directed by Engineer-in-Charge. |
| 128 | M&L for preparing newPlasterd surfaces of walls duly applied2mm wall care Putty and there after applying two coats of oil bound distemper, white or any tint as approved, over and including a coat of primer, complete all as specified and directed. |
| 129 | M&L for preparation of new plastered surfaces of ceiling and applying three coat of white washing, complete all as specified and directed . |
| 130 | M&L complete removal of existing treatment and applying three coats of white wash as in ceiling complete all as specified and directed. |
| 131 | M&L complete removal of existing treatment of old decorated wall surfaces and finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) and providing and applying putty of 1 mm thickness to prepare the surface even and smooth completeall as specified and directed. |
| 132 | M&L for complete removal of existing treatment from the internal surfaces of wall etc,applying thick layer of wall care Putty (minimum thickness of two layers shall be 1.5mm) and thereafter applying two coats of oil bound distemper, white or any tint as approved, over and including a coat of primer, complete all as specified and directed. |
| 133 | M&L preparation of old painted surfaces of steel surfacesof any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paintcomplete all as specified and as directed. |
| 134 | M&L for preparing new wooden surfaces of any description not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed . |
| 135 | M&L preparation of new steel surfacesof any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paintover red oxide complete all as specified and as directed. |
| 136 | M&L for preparing new plastered surfaces of walls and applying two coats cement base paint over a coat of primer, complete all as specified and as directed. |
| 137 | S&F stainless steel grating 75mm dia,complete all as specified and as directed |
| 138 | S&F in repair rotational moulded polyethylene water storage tank 2000ltrs capacity, ISI marked, (cylindrical vertical type double-layered) with closed top including inlet,outlet and wash out holes, provision of G.I Fittings for fixing of the inlet, outlet and washout pipes, hoistedin position, including Dismantaling of unsv water tank complete all as specified and as directed. |
| 139 | S&F in repair 100 mm bore SGSW pipe, grade \"A\", laid in trenches including jointing with cement mortar, including demolition and breaking up drain pipes complete all as specified and directed. |
| 140 | S&F in repair 150 mm bore SGSW pipe, grade \"A\", laid in trenches including jointing with cement mortar, including demolition and breaking up drain pipes complete all as specified and directed. |
| 141 | S&F in repair 200 mm bore SGSW pipe, grade \"A\", laid in trenches including jointing with cement mortar, including demolition and breaking up drain pipes complete all as specified and directed. |
| 142 | M&L for cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregates) for 150 mm borepipes as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and as directed. |
| 143 | M&L for cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregates) for 100 mm borepipes as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and as directed. |
| 144 | M&L for cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregates) for 200 mm borepipes as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and as directed. |
| 145 | Excavationin trenches , n .exceeding 1.5m wide and n exc 1.5m deep for fdn etcfor shafts manholes etc n exc 10 sqm on plan and n exc 1.5 mtr depth andin soft/loose soil and getting out, complete all as specified and as directed. |
| 146 | Excavation over areas, not exceeding 1.5 metre deepin soft/loose soil and getting out, complete all as specified and as directed.. |
| 147 | Excavation over areas, exceeding 1.5 metre deep but n exc 3.00in soft/loose soil and getting out, complete all as specified and as directed.. |
| 148 | Returning, filling in, including spreading, levelling,watering and well ramming in layers not exc 25 cm thick with soil etc complete all as specified and directed. |
| 149 | Removing excavated material to a distance not exc 50.00 mtr and depositng where directed at a level n.exc 1.5m above the stating point, complete all as specified and as directed. |
| 150 | Cutting into existing manholes for connecting new drains of internal dia of pipe 150mm bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required, complete all as specified and as directed. |
| 151 | Cutting into existing manholes for connecting new drains of internal dia of pipe 100mm bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required, complete all as specified and as directed. |
| 152 | Cutting into existing manholes for connecting new drains of internal dia of pipe 200mm bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required, complete all as specified and as directed. |
| 153 | M&L for precast Reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggrgates ) set in CM (1:4) as in landing, cover slab (for manholes, chulla hoods, chajjas, water trough, mangers, shelves and similar article with plain faces including form work complete all as specified and as directed. |
| 154 | Use and waste of formwork to Beams, cantillevers, bressumers, lintels, shelves and similer items for rough finished flat surface of concrete, complete all as specified and as directed. |
| 155 | Use and waste formwork for rough finished flat surface o of suspended slabs such as roof slabs, floor slabs, landing and similar work , not exceeding 200mm thick in rough finish of concrete , complete all as specified and as directed. |
| 156 | M&L for reinforced cement concrete (1:11/2:3)(using 20 mm graded crushed stone aggrgates in nominal mix) as in slabs supported on walls, beams and and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. |
| 157 | M&L TMT bars5mm dia and over upto and including 10mm dia in stirrups, spacers and binders,cut to length, bent to shape required, including cranking, bending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc, complete all as specified and as directed. |
| 158 | Disudging gully trap by taking out sludge and foreign materials and excavating a pit of appropriate size depositing sludge in the pit covering with 30cm thick layer of soil to cover the sludge including removing surplus soil where diercted by Engineer-in-Charge |
| 159 | Dislusging & cleaning of manhole of any description upto 1 mtr in depth including lifting up and removing sludge & accumulated solid/semi solid sludge and any other foreign material with proper equipments & washing down water for smooth functioning of sewage line all as diercted, sludge obtained from cleaning shell be removed to adistance not exceeding 50 mtr all as specified. |
| 160 | All as per above item no 159 above exceeding 1m and n exc 1.5mtr depth complete. |
| 161 | All as per above item no 159above exceeding 1.5m and n exc 2.0mtr depth complete. |
| 162 | Disludging of sludge and other foreign materials complete from sump/septic tank and removing sludge to excavated pit of appropriate size (for burying of sludge and spreading the earth n exc 30cm thick over filled sludge and removing surplus soil where diercted at a distence n exc 50 m where diercted sump of capacity100 user |
| 163 | All as per above item no 162 hear in before but sump of capacity 50 users |
| 164 | All as per above item no 162 hear in before but sump of capacity 25 users |
| 165 | M & L Loose filling with aggregates of gauge 80 to 150 mm in soakage pits, soakage wells with broken bricks |
| 166 | M&L for 100mm thick PCC (1:3:6) type (C-1) (using 40mm graded crushed stone aggregate), as in hardstanding /Path laid in alternate bays (n exc 4 Sqm each)complete all as specified and directed. |
| 167 | M & L for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concreteand screwing etc. wind ties for roof including securing bolts including decuring bolts posts and struts in fencing including cutting tops to shape as sirected drilling hloes, notching for wire etc ,flat iron fillets, including all necessary drilling , bolting or riveting etc and similar work . |
| 168 | Cutting in to existing road surface n exc 1.50 m deep and n exc 0.9m wide for laying soil pipe etc and after laying the pipe making good with returing filling with PCC (1:2:4) type (B-2) 40mm graded aggregate of minium 100mm thick complete all as specified and diercted. |
| 169 | Taking down carefully existing aluminium point wiring (light / fan / socket or power point) complete, with all fittings such as switch socket combination, switches, sockets, regulator, ceiling rose, utility light fittings and lamp holders etc and making good the disturbed surfaces of walls, roof and floor etc to match with the existing specification, complete all as specified and as directed. |
| 170 | Taking down existing unserviceable submain wiring (including conduit /casing -caping), any size and making good the disturbed surfaces to match with theadjoining surfaces, complete all as specified and as directed. |
| 171 | M&L for point wiring for one light point/ one fan point/ one exhaust fan controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLSH) cable 1100 Volts grade drawn through and including rigid non metallic PVC concealed conduit (medium grade) of suitable dia, (also including conduit fittings, along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLSH) cable for earth continuity wire, connected to earth dolly and to be terminated in and including factory made anodized pressed steel sunken boxes (Having wall thickness not less than 1.22 mm for boxes suitable size and beyond that the wall thickness shall be not less than 1.63 mm), concealed type with and including 3mm thick bakelite sheet cover for mounting switches, sockets, fan regulators etc, testing on completion also including cutting chases for concealed conduit, steel boxes etc, pinning in, making good the surfaces in CM 1:3 to match with the adjoining surfaces , complete all as specified and as directed. |
| 172 | All as per item No 171 here-in-before but for one 3pin 5 Amp switch socket outlet, same boardcomplete all as specified and as directed. |
| 173 | All as per item No 171 here-in-before but for one 3pin 5 Amp switch socket outlet, independent board , complete all as specified and as directed. |
| 174 | All as per item No 171 here-in-before but for one 5/15 Amp switch socket outlet, independent with 2.5 Sqmm single core multi-stranded copper conductor cable (FRLSH) along with 2.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLSH) cable for earth continuity wire, complete all as specified and as directed. |
| 175 | All as per item No 171 here-in-before but for one light p[oint controlled by two, 2-way switch, complete all as specified and as directed. |
| 176 | Material and labour for sub main wiring with 2 run of single core PVC insulated (unsheathed) multi stranded copper conductor FRLS cable of size 2.5 sqmm and 2 single core PVC insulated (unsheathed) multi stranded copper conductor FRLHS cable of size 2.5sqmm as in continuous earth wire drawn into and including concealed PVC conduit, medium grade of 20 mm bore complete with fittings, PVC Junction Boxes, fixings accessories, also including cutting chases, pinning in, making good to facing and pointing in using cement mortar 1:3 and making good disturbed surfaces to match with the adjoining surfaces, complete all as specified and as directed.Note:- For payment purposes, 2 runs of main cable (each of 1RM) 1 run of earth continuity cable (1RM) and one run of conduit (1RM) all together shall be considered as \"1RM\". |
| 177 | All as per item No 176 here-in-before but 2 Single core of size 4Sqmm and eart continuity conductor of size 4Sqmm, complete all as specified and as directed. |
| 178 | Supply and fixing switch piano flush type, single pole, bell push, 5 amps, complete all as specified and as directed. |
| 179 | Supply and fixing switch piano flush type, single pole, one way bell push, 5 amps, complete all as specified and as directed. |
| 180 | Supply and fixing Socket outlet 5 Amps 3 pin flush type complete all as specified and as directed. |
| 181 | Supply and fixing switch piano flush type, single pole,two way, 5 amps, complete all as specified and as directed. |
| 182 | Supply and fixing switch piano flush type, single pole,one way, 6 amps, complete all as specified and as directed. |
| 183 | S&F Switch socket combination , 2 in 1, 2/3pin, 5 Amp,complete all as specified and as directed. |
| 184 | S&F Switch socket combination, 2 in 1,3pin,5 and 16 amp, complete all as specified and as directed. |
| 185 | S&F ceiling rose, 3 phase, PVC/ polycarbonate, isolated body, including taking down old unsv onescomplete all as specified and directed. |
| 186 | S& F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd |
| 187 | S&F Buzzer Ding Dong, AC, 230 Volts, single pole, including taking down old unsv onescomplete all as specified and directed. |
| 188 | S & F in repairs LED battery backup inverter bulb of lamp wattage:-12 watts, battery :- not less than 2200mah or not less than 4 hrs backup efficancy not less than 120 LM /Watt complete all as specified and directed. |
| 189 | S & F lamp holder, PVC/Polycarbonate type withcordgrip cap suitable for back plate suitable for batten fittings, complete all as specified and directed. |
| 190 | S & F wall/surface mounted LED light fitting 50w or next higher rating (2 fit) CRI>80CI>5700 k, with powdered coated aluminum housing & integrated driver with THD<10% with all accessories internally prewired and including connecting up with and including twin/three core twisted fleible conductor cable of suitable size incl flexible hose complete all as specified and directed, |
| 191 | S & F in repair of surface and wall mounted LED tube light fittings battern 1x,20 watt 220 VAC decorative box type with driver , holder including LED tube light connecting up with three core fleible cooper conductor cable os suitable size from ceiling rose Aaluminium houseing & integrated Electronic driver with IP20,PF 0.90, total systum lumens 1050, completeall as specified as directed. |
| 192 | S &F for wall mounted LED tube lingh fittingmirror type with high out put diffuser 2 feet, 10 watta 220 V AC 10 watts batten for surface, anodized extruded aluminium housing, high transmisivity diffuser, with driver , holder including LED tube light connecting up with three core fleible cooper conductor cable os suitable size from ceiling rose Aaluminium houseing & integrated Electronic driver with IP20,PF 0.90, total systum lumens 1050, completeall as specified as directed.completeall as specified as directed. |
| 193 | S & F in repair of LED bldg security light fittings of capacity 25 W made up of pressure die cast aluminium housing with high effciency LEDs as lighting source and lens embedded PC cover having top opening seprate driver compartment with IP66 protection and impact resistance of IK07, lumen efficiency of minmium 120 Lm/W and SPD of 10KV with a repair/replacemnt warranty of minimum 05 years incl taking down old unsv from pole and refix at the same position completeall as specified as directed. |
| 194 | S&F VTPN, DB, MCB incomer, 4 ways, double door, Metal door , IP-43 IK 09 in 250A rated copper bus bars, earth bar, neutral links,complete including blanking plates as required & fixed flush to wall and making good the disturbed surfaces in CM 1:3, complete all as specified and as directed. Make: Cat No 507759 of Legrend/L&T or of equivalent make as mentioned in the Particular Specification Appx \"B\" as approved by the GE.Note: Payment of MCCBs & MCBs shall be measured and paid for separately. |
| 195 | S&F MCB, TPN,40 Amps, 415V, 50 Hz, breaking capacity 10 KA, complete all as specified and directed. |
| 196 | S&F sheet metal enclosure for MCBs DBs, SPN, 8 waydouble door, Metal door , IP-43 IK 09 in 250A rated copper bus bars, earth bar, neutral links,complete including blanking plates as required & fixed flush to wall and making good the disturbed surfaces in CM 1:3, complete all as specified and as directed. Make: Cat No 507759 of Legrend/L&T or of equivalent make as mentioned in the Particular Specification Appx \"B\" as approved by the GE |
| 197 | Supply and fix exhaust fan of 250 mm sweep made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, with botls nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaut fan for connection and making suitable size of hole to esiting brick wall for fan base complete all as specified and directed. (Note: Cost of suitable opening wall for fixingexhaut fan is deemed to be included in overall rate quoted). |
| 198 | S & F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB\"C\" curve of 20A ratigng complete all as specified and directed. |
| 199 | S&F MCB, SPN, DB, 12 ways, double door, Metal door, IP-43 IK 09 in 100A rated copper bus bars, earth bar, neutral links complete including provision of blanking plates as required & fixed flush to wall and making good the disturbed surfaces in CM 1:3, completeall as specified and directed. |
| 200 | S&F MCB, SPN, 40 Amps, 240V, 50 Hz, breaking capacity 10 KA, \"C \" series complete all as specified and directed. |
| 201 | S&F MCB SP, 10KA, 230V, C-curve, 6-32 Amps, complete all as specified and directed. |
| 202 | M&L for Earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4.0mm diaby means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, PCC (1:3:6) type C-1 with 50 mm thick Pre-cast RCC (1:2:4) type B-1 cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (Medium grade), wire mesh, aluminium lugs, complete in all respect, GI earth strip protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 m and necessary testing on completion, including dismantling old unsv ones complete all as specified and as Note: GI earth wire 4mm dia and 15mm bore protection pipe upto 7.5m from earth plate is deemed to be included in the rate quoted be contrator. |
| 203 | Supply and fixing GI tubing, light grade, 40mm bore for protection of cable under road crossing, across drain, along electric pole or floor /walletc, completeall as specified and directed.Note : Excavation & Earthwork shall be measured & paid for separately. However the cost for provision of clamps made from mild steel flat of required size, bolts, nuts, washers etc (including painting of mild steel surfaces with 2 coats of aluminium paint over 1 coat of red oxide primer) for fixing of G.I. pipes with poles etc shall be deemed to be included in the quoted rate of above item. |
| 204 | M & L for cutting and making and enlarging existing hole for fixing of exhaust fan, nuts, bolts washer including plastering and make good the disturbed surface with the existing complete all as directed and specified. |
| 205 | S&F Metal plug Socket DB with sheetenclosure with & including a two pin and earth plug and socket, also with and including one number single pole, MCB, 20 Amps, 240 volts Geysor connenction , , complete all as directed and specified. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy