| 1 | 33 KV VCB, Outdoor Porcelain clad type with complete structure and accessories excluding CT & pannel |
| 2 | 33 KV control & relay panel with static relay for Transformer protection |
| 3 | 11 KV VCB, Outdoor Porcelain clad type with complete structure and accessories excluding CT & pannel |
| 4 | 11 KV.C.Ts.(Outdoor dry type) 300-150/5-5 Amps |
| 5 | 11 KV control & relay panel with numerical static relay for double feeder protection |
| 6 | 9 KV Gapless type(5 KA) polymer lightening arrestor |
| 7 | 33 KV Single Phase PTs. |
| 8 | M S Channel 100X50x6 mm |
| 9 | 33 KV Isolator complete with insulators 600 Amp. w/o earth switch |
| 10 | IRON STEEL SCRAP |
| 11 | ACSR Panther conductor 0.20 sq. inch (200 sq.mm Al.Eq.) |
| 12 | 33 KV CT Outdoor Oil immersed type 300-150/5-5 Amp |
| 13 | 33 KV Polymer Lightening arrestor Gapless type, Station type |
| 14 | M.S. FLAT,65x6 mm |
| 15 | 33 KV Pin Insulator Polymer Composite (10 KN) |
| 16 | 11 KV Pin Insulator Polymer Composit (5 KN) |
| 17 | 33 KV (45KN) Composite Polymer Disc Insulators |
| 18 | 11 KV(45KN) Composite Polymer Disc Insulators |
| 19 | 11 KV Strain hardware (T&C type) fittings |
| 20 | Danger Boards Enamelled 33 KV |
| 21 | 11 KV, ISOLATOR 600 AMP.(Turn and twist type) |
| 22 | Copper Control Cable 8 Core. 2.5 Sq.mm. (Unarmoured) |
| 23 | Copper Control Cable 4 Core. 2.5 Sq.mm. (Unarmoured) |
| 24 | 11 KV PT Single Phase |
| 25 | Copper Control Cable 2 Core. 2.5 Sq.mm. (Unarmoured) |
| 26 | M.S.Angle 50x50x6 mm |
| 27 | 3Ph 4W 3x63.5V lb=5A Imax=10A, HT trivector meter,0.5s,(For Consumer metering) |
| 28 | 33/11 KV Power transformer , OFTC Type , 3150 KVA (Loss 3+15 KW)(Rep-BGP) |
| 29 | M S ANGLE 75X75X6 mm |
| 30 | M S Angle 65X65X6 mm |
| 31 | M S FLAT 65X8 mm |
| 32 | 11 KV AB Switch Polymer type 400 Amp with Complete fitting |
| 33 | Marshelling box with 10 no. connectors |
| 34 | T CLAMP FOR 33KV & 11KV BUS, SUBSTATION upto DOG |
| 35 | Bi Metallic Clamp for Power Transformer of Brass Flat 50x50x10MM |
| 36 | Stringing of Each 33 KV Bus- upper and lower including drop jumpering, jointing with clamps, incoming DP/ ME to BUS |
| 37 | Stringing of Each 11 KV Bus-upper and lower bus including, drop jumpering and jointing with clamps,through outgoing VCB/ ME/ DP, upto station transformer |
| 38 | Stringing of All 33 KV & 11 KV Jumpers - from 33 KV gartry through 33 KV VCB to PTR to 11 KV gantry through 11KV VCB |
| 39 | 33 KV composite polymer Strain set with hard ware suitable for Panther Conductor |
| 40 | Stone Block/Pre cast block for base pedding(450X450X75MM) |
| 41 | Concreting of structures & foundation (1:3:6) |
| 42 | Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire |
| 43 | Concreting of foundation of VCB (1:3:6) @ 3.5 cmt per VCB plinth |
| 44 | Erection of Plinth per VCB- 33KV or 11KV |
| 45 | M.S.Nuts with Bolts |
| 46 | Red oxide paint |
| 47 | Aluminium paint |
| 48 | Galvanized Iron (GI) Flat 50X6 MM |
| 49 | G.I.Pipe 40 mm Dia C grade type |
| 50 | GI Pipe 150 mm B Grade |
| 51 | Earthing Rod 3 mtrs.(Gelvanised) 25 mm Rod |
| 52 | Bentonite compound powder |
| 53 | Additional Erection Charge |
| 54 | P&F perfo cable tray 300 wide,2 thick fix 45x45x5 MS angle grouted CC 1:24 |
| 55 | LED Lamp with 48 W Streetlight lumin with pressure die cast al housing body output Rated life Burning Hrs 50000 Hr CCT>5500K,IP66 OIR of complete lumin > IK08. PF >0.9 IS10322/IEC 60598, LM79 &LM80 LED Efficiency>130 Lm/w,nominal CRI75,2Yr Warranty |
| 56 | Erection Cost |
| 57 | GST @ 18% on Total Material Amount and Erection Cost |