| 1 | SUPPLY PORTIONA.Tower PortionFabrication and supply of tower part with stubs, bolts & nuts, step bolts, U-bolts, hangers, D-Shackle etc. of following type of towers132kV D/C DA type Tower (KRR Design) |
| 2 | i) +3m extn. Only |
| 3 | i) +6m extn. Only |
| 4 | 132kV D/C DB type towers (KRR Design ) |
| 5 | i) +3m extn. Only |
| 6 | ii) +6m extn. Only |
| 7 | ii) +9m extn. Only |
| 8 | 132kV D/C DC type towers (KRR Design ) |
| 9 | i) +3m extn. Only |
| 10 | ii) +6m extn. Only |
| 11 | ii) +12m extn. Only |
| 12 | 132kV D/C DD type towers (KRR Design ) |
| 13 | i) +3m extn. Only |
| 14 | ii) +6m extn. Only |
| 15 | iii) +9m extn. Only |
| 16 | iv) +12m extn. Only |
| 17 | v) +18m extn. Only |
| 18 | vi)Extra cross-arms (set of 3) |
| 19 | 132kV D/C Gantry |
| 20 | Supply of Earthing of towersi) Pipe type |
| 21 | Supply of following Tower accessoriesi) Danger Plate |
| 22 | ii)Number Plate |
| 23 | iii) Phase Plate (set of 3) |
| 24 | iv) Circuit Plate (set of 2) |
| 25 | v)Bird Guard (set of 3) |
| 26 | vi) Anti climbing device |
| 27 | B.LINE MATERIALConductor (0.4“ ACSR Zebra) |
| 28 | Conductor (ACSR Panther) |
| 29 | Earth wire(7/3.15 mm) |
| 30 | 132KV Post Insulators |
| 31 | *132KV Anti-Fog type Disc Insulator or 132KV Silicon Rubber Polymer Insulator stringsi)70 kN |
| 32 | ii) 120 kN |
| 33 | Hardware Fittings for ACSR Zebra Conductor i. Single ‘I’ Suspension String |
| 34 | ii. Single Suspension Pilot String |
| 35 | iii. Single Tension String |
| 36 | iv. Double Tension String |
| 37 | Hardware Fittings for ACSR Panther Conductor i. Single ‘I’ Suspension String |
| 38 | ii. Single Suspension Pilot String |
| 39 | iii. Single Tension String |
| 40 | Conductor & Earth wire Accessoriesi)Mid Span Compression Joint for ACSR Zebra Conductor |
| 41 | i)Mid Span Compression Joint for ACSR Panther Conductor |
| 42 | ii) Mid Span Compression Joint for earthwire |
| 43 | iii)Repair sleeves for ACSR Zebra/Panther Conductor |
| 44 | iv) Vibration damperfor ACSR ZebraConductor |
| 45 | iv) Vibration damperfor ACSR PantherConductor |
| 46 | v) Flexible copper Bond |
| 47 | vi) Vibration damper for earthwire |
| 48 | vii) Earth-wire Tension clamp |
| 49 | viii) Repair sleeves for earthwire |
| 50 | ix) Earth-wire Suspension clamp |
| 51 | C. OPGW & its Associated HardwareOPGW (24 Fiber) (DWSM, G.652D) (equivalent to Earth Wire: 7/3.15 mm in all respect) 220 kV Sampla to 132 kV Assaudhaon D/C portion |
| 52 | Hardware Set for above 24 OPGW Fiber Optic (equivalent to Earth Wire: 7/3.15 mm in all respect) cabling includingall cable fitting & accessories except joint box |
| 53 | FODP 48F: Indoor type, rack mounted with FCPC Coupling and pig tails (5mtrs, each) as applicable for 220 kV S/Stn. Sampla and 132 kV S/Stn. Assaudha |
| 54 | Joint Box 24 Fiber OPGW to OPGW (as applicable) (Quantity may varies as per drum schedule of OPGW) |
| 55 | Joint Box 24 Fiber OPGW to FOAC 220 kV S/Stn. Sampla and 132 kV S/Stn. Assaudha |
| 56 | Fiber Optic Approach Cable, 24 fiber (DWSM) along with PLB HPE Ducts of suitable size & strength and all accessories for 220 kV S/Stn. Sampla and 132 kV S/Stn. Assaudha |
| 57 | Wideband Communication Equipment and SparesTelecom EquipmentSDH Equipment (STM - 16 MADM up to 5 MSP protected directions)Base Equipment (Common cards, Cross connect/control cards, optical base cards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc. fully equipped excluding (ii) & (iii) below to be installed at 220 kV S/Stn. Sampla and 132 kV S/Stn. Assaudha |
| 58 | Optical Interface Cards/SFPL16.1 SFP (The quantities will be decided at the time of detailed engineering) |
| 59 | L16.2 SFP (The quantities will be decided at the time of detailed engineering) |
| 60 | S4.1 SFP (The quantities will be decided at the time of detailed engineering) |
| 61 | Tributary Cards E1 Interface card ( Min. 32 interfaces per card) |
| 62 | Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card) |
| 63 | Gigabit Ethernet (Layer 2) Interface (min. 2 nos.) |
| 64 | Equipment Cabinet with DDF and all installation accessories |
| 65 | Network Manager System - Craft TerminalHardware |
| 66 | Software |
| 67 | VOIP telephone instrument with one common switch(min. 8 port)compatible with SLDC |
| 68 | Integration of the Equipment with existing networkNote:- Above Quantities covers the requirement of remote station as well. |
| 69 | Mandatory SparesTelecom Equipment for 220 kV S/Stn. Sampla and 132 kV S/Stn. AssaudhaOptical Interface Cards/SFPL16.1 SFP (The quantities will be decided at the time of detailed engineering) |
| 70 | L16.2 SFP (The quantities will be decided at the time of detailed engineering) |
| 71 | S4.1 SFP (The quantities will be decided at the time of detailed engineering) |
| 72 | Tributary CardsE1 Interface card ( Min. 32 interfaces per card) |
| 73 | Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card) |
| 74 | Gigabit Ethernet (Layer 2) Interface (min. 2 nos.) |
| 75 | Pre Connected Optical Patch Cards (10Mtrs)- pack of six patch cards |
| 76 | Erection PORTIONA.Tower PortionFabrication and supply of tower part with stubs, bolts & nuts, step bolts, U-bolts, hangers, D-Shackle etc. of following type of towers132kV D/C DA type Tower (KRR Design) |
| 77 | i) +3m extn. Only |
| 78 | i) +6m extn. Only |
| 79 | 132kV D/C DB type towers (KRR Design ) |
| 80 | i) +3m extn. Only |
| 81 | ii) +6m extn. Only |
| 82 | ii) +9m extn. Only |
| 83 | 132kV D/C DC type towers (KRR Design ) |
| 84 | i) +3m extn. Only |
| 85 | ii) +6m extn. Only |
| 86 | ii) +12m extn. Only |
| 87 | 132kV D/C DD type towers (KRR Design ) |
| 88 | i) +3m extn. Only |
| 89 | ii) +6m extn. Only |
| 90 | iii) +9m extn. Only |
| 91 | iv) +12m extn. Only |
| 92 | v) +18m extn. Only |
| 93 | vi)Extra cross-arms (set of 3) |
| 94 | 132kV D/C Gantry |
| 95 | Supply of Earthing of towersi) Pipe type |
| 96 | Supply of following Tower accessoriesi) Danger Plate |
| 97 | ii)Number Plate |
| 98 | iii) Phase Plate (set of 3) |
| 99 | iv) Circuit Plate (set of 2) |
| 100 | v)Bird Guard (set of 3) |
| 101 | vi) Anti climbing device |
| 102 | B.LINE MATERIALConductor (0.4“ ACSR Zebra) |
| 103 | Conductor (ACSR Panther) |
| 104 | Earth wire(7/3.15 mm) |
| 105 | 132KV Post Insulators |
| 106 | *132KV Anti-Fog type Disc Insulator or 132KV Silicon Rubber Polymer Insulator stringsi)70 kN |
| 107 | ii) 120 kN |
| 108 | Hardware Fittings for ACSR Zebra Conductor i. Single ‘I’ Suspension String |
| 109 | ii. Single Suspension Pilot String |
| 110 | iii. Single Tension String |
| 111 | iv. Double Tension String |
| 112 | Hardware Fittings for ACSR Panther Conductor i. Single ‘I’ Suspension String |
| 113 | ii. Single Suspension Pilot String |
| 114 | iii. Single Tension String |
| 115 | Conductor & Earth wire Accessoriesi)Mid Span Compression Joint for ACSR Zebra Conductor |
| 116 | i)Mid Span Compression Joint for ACSR Panther Conductor |
| 117 | ii) Mid Span Compression Joint for earthwire |
| 118 | iii)Repair sleeves for ACSR Zebra/Panther Conductor |
| 119 | iv) Vibration damperfor ACSR ZebraConductor |
| 120 | iv) Vibration damperfor ACSR PantherConductor |
| 121 | v) Flexible copper Bond |
| 122 | vi) Vibration damper for earthwire |
| 123 | vii) Earth-wire Tension clamp |
| 124 | viii) Repair sleeves for earthwire |
| 125 | ix) Earth-wire Suspension clamp |
| 126 | C. OPGW & its Associated HardwareOPGW (24 Fiber) (DWSM, G.652D) (equivalent to Earth Wire: 7/3.15 mm in all respect) 220 kV Sampla to 132 kV Assaudhaon D/C portion |
| 127 | Hardware Set for above 24 OPGW Fiber Optic (equivalent to Earth Wire: 7/3.15 mm in all respect) cabling includingall cable fitting & accessories except joint box |
| 128 | FODP 48F: Indoor type, rack mounted with FCPC Coupling and pig tails (5mtrs, each) as applicable for 220 kV S/Stn. Sampla and 132 kV S/Stn. Assaudha |
| 129 | Joint Box 24 Fiber OPGW to OPGW (as applicable) (Quantity may varies as per drum schedule of OPGW) |
| 130 | Joint Box 24 Fiber OPGW to FOAC 220 kV S/Stn. Sampla and 132 kV S/Stn. Assaudha |
| 131 | Fiber Optic Approach Cable, 24 fiber (DWSM) along with PLB HPE Ducts of suitable size & strength and all accessories for 220 kV S/Stn. Sampla and 132 kV S/Stn. Assaudha |
| 132 | Wideband Communication Equipment and SparesTelecom EquipmentSDH Equipment (STM - 16 MADM up to 5 MSP protected directions)Base Equipment (Common cards, Cross connect/control cards, optical base cards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc. fully equipped excluding (ii) & (iii) below to be installed at 220 kV S/Stn. Sampla and 132 kV S/Stn. Assaudha |
| 133 | Optical Interface Cards/SFPL16.1 SFP (The quantities will be decided at the time of detailed engineering) |
| 134 | L16.2 SFP (The quantities will be decided at the time of detailed engineering) |
| 135 | S4.1 SFP (The quantities will be decided at the time of detailed engineering) |
| 136 | Tributary Cards E1 Interface card ( Min. 32 interfaces per card) |
| 137 | Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card) |
| 138 | Gigabit Ethernet (Layer 2) Interface (min. 2 nos.) |
| 139 | Equipment Cabinet with DDF and all installation accessories |
| 140 | Network Manager System - Craft TerminalHardware |
| 141 | Software |
| 142 | VOIP telephone instrument with one common switch(min. 8 port)compatible with SLDC |
| 143 | Integration of the Equipment with existing networkNote:- Above Quantities covers the requirement of remote station as well. |
| 144 | Mandatory SparesTelecom Equipment for 220 kV S/Stn. Sampla and 132 kV S/Stn. AssaudhaOptical Interface Cards/SFPL16.1 SFP (The quantities will be decided at the time of detailed engineering) |
| 145 | L16.2 SFP (The quantities will be decided at the time of detailed engineering) |
| 146 | S4.1 SFP (The quantities will be decided at the time of detailed engineering) |
| 147 | Tributary CardsE1 Interface card ( Min. 32 interfaces per card) |
| 148 | Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card) |
| 149 | Gigabit Ethernet (Layer 2) Interface (min. 2 nos.) |
| 150 | Pre Connected Optical Patch Cards (10Mtrs)- pack of six patch cards |
| 151 | D. Civil WorksDetailed Survey |
| 152 | Furnishing bore log data |
| 153 | Construction of tower foundations as per HVPNL Drgs & Specifications for 0 to 6Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect.i) 132kV D/C \"DA\" type Tower (KRR Design) classified as - Wet |
| 154 | - Dry |
| 155 | ii) 132kV D/C \"DB\" type Tower (KRR Design) classified as - Wet |
| 156 | - Dry |
| 157 | iii) 132kV D/C \"DC\" type Tower (KRR Design) classified as - Wet |
| 158 | - Dry |
| 159 | iv) 132kV D/C \"DD\" type Tower (KRR Design) classified as - Wet |
| 160 | - Dry |
| 161 | Construction of tower foundations as per HVPNL Drgs & Specifications for above 6Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect.i) 132kV D/C \"DD\" type Tower (KRR Design) classified as - Wet |
| 162 | - Dry |
| 163 | ii) 132kV D/C \"DC\" type Tower (KRR Design) classified as - Dry |
| 164 | Gantriesi) 132kv Gantry (KRR Design) |
| 165 | Dewatering of subsoil water for lowering of water table to enable excavation of earth, concreting for foundations/stub and backfilling, by boring of tube wells or deploying well point system so that continuous lowering of water table is made till completion of work, without disturbing the soil characteristics. The rate shall include all type of expenditure for required dewatering arrangements and irrespective of type of tower including extensions if any. |