| 1 | Material and labour for replacement of fuel filterfor 320 KVA DG Set , Make:-Greaves and change of fuel filter after every 250 Hrs complete all as specified and directed by Engr-in-Charge. |
| 2 | Material and labour for replacement of fuel filterfor 320 KVA DG Set , Make:-Kiloskar and change of fuel filter after every 250 Hrs complete all as specified and directed by Engr-in-Charge. |
| 3 | Material and labour for replacement of fuel filterfor 63/35 KVA DG Set , Make:-Kiloskar and change of fuel filter after every 250 Hrs complete all as specified and directed by Engr-in-Charge. |
| 4 | Material and labour for replacement of lub oilfilter for 320 KVA DG Set , Make:- Kirloskar and Model HA69TC and change of fuel filter after every 250 Hrs including lubricating and greasing to all parts complete all as specified and directed by Engr-in-Charge. |
| 5 | Material and labour for replacement of lub oilfilter for 320 KVA DG Set , Make:- Greaves and Model HA69TC and change of fuel filter after every 250 Hrs including lubricating and greasing to all parts complete all as specified and directed by Engr-in-Charge. |
| 6 | Material and labour for replacementlub oil filterfor 63/35 KVA DG Set , Make:-Kiloskar and change of fuel filter after every 250 Hrs complete all as specified and directed by Engr-in-Charge. |
| 7 | Material and labour for replacement ofair cleaner filter Cat part No KV250052000 for 320 KVA DG setchange of air cleaner filter Make: Kirloskar/Greaves after every 500 Hrs complete all as specified and directed by Engr-in-Charge. |
| 8 | Material and labour for replacement ofair cleaner filter for 100 KVA DG setchange of fuel filter Make:Cummins/Kirloskar after every 500 Hrs complete all as specified and directed by Engr-in-Charge. |
| 9 | Material and labour for replacementl of Air cleaner filterfor 63/35 KVA DG Set , Make:-Kiloskar and change of fuel filter after every 500 Hrs complete all as specified and directed by Engr-in-Charge. |
| 10 | Calbiration of injector assembly including replacement of injector cups, barrel,nozzles, O-rings screen filter and setting the oil pressure with testing suitable for 100/63/62.5/ KVA DG Set, Make:- Kirloskar and Model HA69TC DG set complete all as specified and directed by Engr-in-Charge. |
| 11 | Calbiration of injector assembly including replacement of injector cups, barrel,nozzles, O-rings screen filter and setting the oil pressure with testing suitable for320 KVA DG Set , Make:-Greaves/Kirloskar DG set complete all as specified and directed by Engr-in-Charge. |
| 12 | S&F in replacement of fan belt A-49 cut type for 100/63/62.5/ KVA DG set complete all as specified and directed by Engr-in-Charge. Make-Fenner/KCL |
| 13 | S&F in replacement of fan belt B-43 cut type for 320 KVADG set complete all as directed by Engr-in-Charge. Make-Fenner/KCL |
| 14 | Supply & fix in replacement of U/S lead acid battery 12 Volt 180AH with initially charged complete all as specified and directed by Engr-in-Charge. Make-Exide |
| 15 | Repair/servicing self starter by supply and fixing including taking out the following parts ,(a). Field Coil (b). Armature Winding (c ). Bush (d). Solenoid switch (Gear)for 320 KVA DG Sets complete all as specified and directed by Engr-in-Charge.Make : Kirloskar |
| 16 | Repair/servicing self starter by supply and fixing including taking out the following parts ,(a). Field Coil (b). Armature Winding (c ). Bush (d). Solenoid switch (Gear)for 63/62.5/100 KVA DG Sets complete all as specified and directed by Engr-in-Charge.Make : Kirloskar |
| 17 | M&L for replacement of automatic voltage regulator for DG Set of capacity 320/63 KVA.. |
| 18 | Dismantling the radiator from the engine of 320 KVA DG settransporting the radiator from site to workshop. Dismantling the radiator in and including descaling ,gas welding the leaking tube whichever required for proper functioning of radiator. After repair retransportation from workshop to site and fixing the same with engine as existing and reseting complete all as specified and directed by Engr-in-Charge. |
| 19 | Dismantling the radiator from the engine of 100 KVA DG settransporting the radiator from site to workshop. Dismantling the radiator in and including descaling ,gas welding the leaking tube whichever required for proper functioning of radiator. After repair retransportation from workshop to site and fixing the same with engine as existing and reseting complete all as specified and directed by Engr-in-Charge. |
| 20 | Dismantling disconnecting Turbo charger from 320 Kva DG Sets supply and fixing the same complete as specified and as directed by Engr-in-charge.Make :Cummins. |
| 21 | Supply & fixing in replacement Diesel pipe set flexible for 320/63/40KVA DG Set complete all as specified and as directed by Engr-in-Charge.Make :- Cummins/Kirloskar |
| 22 | Supply & fixing hose rubber C/W inletsuitable for 320 Kva DG Set complete all as specified and as directed by Engr-in-Charge.Make :-Kirloskar |
| 23 | Supply & fixing water pump assembly Cat part No-KL617605000 suitable for 320 Kva DG Set complete all as specified and as directed by Engr-in-Charge.Make :- Kirloskar |
| 24 | Supply & fixing water pump assembly Cat part No-KL617605000 suitable for 100 Kva DG Set complete all as specified and as directed by Engr-in-Charge.Make :- Kirloskar |
| 25 | S&F in replacement Alternator (Battery Charger) suitable for DG Set of capacity 320 KVA of existing make and Modal complete all as specified and directed. |
| 26 | Supply & Fixing control card (PCB) suitable for DG set of capacity 63 to 125 KVA complete all as specified and directed by Engr-in-Charge. Make- Kirloskar/Cummins |
| 27 | Supply and fixing for replacement of copper battery lead 3 Mtrs long PVC insulated multi stranded with brass clamp incl necessary bolts & nuts and fixing lugs etc complete all as specified and as directed by Engr-in-Charge. |
| 28 | Draining all the U/S DAFC 50% from the DG Sets Supply and filling the DAFC 50% all as specified and as directed by Engr-in-charge. Make Servo, HP or any approved Make. |
| 29 | Supply and fix electronic nozzle suitable for 320 KVA DG set of existing make and model including taking out old UNSV nozzles Make:-Greaves/Kirloskar/CumminsDG set complete all as directed by Engr-in-Charge. |
| 30 | Descriptiuon all as per item Ser No. 29.00 here in beforebut suitable for DG set of capacity 63 to 100 KVA |
| 31 | Supply and fixnozzle suitable for 320 KVA DG set of existing make and model including taking out old UNSV nozzles Make:-Greaves/Kirloskar/CumminsDG set complete all as specified and as directed by Engr-in-Charge. |
| 32 | Descriptiuon all as per item Ser No. 31.00 here in beforebutsuitable for DG set of capacity 63 to 100 KVA |
| 33 | S&F inreplacement oil feed pump with assembly of existing make and model suitable for DG set of capacity 63 KVA to 320 KVA complete all as specified and as directed by Engr-in-Charge. |
| 34 | S&F inreplacementFUEL pump with assembly of existing make and model suitable for DG set of capacity 63 KVA to 125 KVA complete all as specified and as directed by Engr-in-Charge. |
| 35 | S&F in replacement Self Starter 24 volt suitable for DG Set of capacity 320 KVA of existing make and model complete all as specified and directed. Make : Lukas or equivalent |
| 36 | S&F in replacement Self Starter 24 volt suitable for DG Set of capacity 35 TO 100 KVA of existing make and model complete all as specified and directed. Make : Lukas or equivalent |
| 37 | Supply and fix off load change over switch415 volt 50 Hz confirm to IS-13947-3 with enclosure and side handle of cap 400 Amp four pole including takind down old switch complete all as specified and as directed by Engr-in-Charge.Make Havells /C&S/Indoasian |
| 38 | Supply and fix off load change over switch415 volt 50 Hz conform to IS-13947-3 with enclosure and side handle of cap 200 Amp four pole including takind down old switch complete all as specified and as directed by Engr-in-Charge. Make Havells /C&S/Indoasian |
| 39 | M&L Calibration of electronic panel of 320 KVA KirloskarDG set with Laptop and fixing all fault including replacement of US relays/wiring as per requirement by cummins engineer complete all as specified and as directed by Engr-in-Charge. |
| 40 | M&L Calibration of electronic panel of 100/63 KVA KirloskarDG set with Laptop and fixing all fault including replacement of US relays/wiring as per requirement by cummins engineer complete all as specified and as directed by Engr-in-Charge. |
| 41 | M&L for repair and cleaning of exhaust silencer of DG Set of capacity 320 KVAincluding cutting and welding as per requirement complete all as specified and directed by Engr-in-Charge |
| 42 | M&L for repair and cleaning of exhaust silencer of DG Set of capacity 320 KVAincluding cutting and welding as per requirement complete all as specified and directed by Engr-in-Charge. |
| 43 | Supply & fixing inreplacement of Oil sensor suitable for DG set ofcapacity 63 to 320 KVA ofDG Sets completeall as specifiedanddirected by Engr-in-Charge. |
| 44 | Supply & fixing inreplacement of Water/Coolentsensor of capacity 63 to 320 KVA DG Sets completeall as specifiedanddirected by Engr-in-Charge. |
| 45 | M&L for Calibration of FIP of DG set of capacity 320 KVA including supply & fixing in replacement plunger, DV, governor wet O-Ring, Pin roll, barrel, Pin ball bearing spring,washer and testing for following capacity of DG Set complete all as specified and directed by Engr in Charge. |
| 46 | Description all as per item Ser No. 45.00 here in before but DG set of capcity 63 to 100 KVA |
| 47 | Supply and Replacement ofThermostate valve suitable forDG Setsof capacity 63 to 320 KVAcompleteall as specified and directed by Engr-in-Charge. |
| 48 | M&L for Strip opening of alternator 160/125KVA DG set , removing rotor from the stator and rewinding to CT coils complete with super enameled copper winding wire of appropriate size including insulating material and replacing the following parts of the alternator.Note: Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge. |
| 49 | Description all as per item Ser No. 48.00 here in before but DG set of capacity 63/100 KVA |
| 50 | Earthing complete withgalvanized steel earth plate electrode 60 cmx 60 cm x 6 mm thick buried directlyin ground (earth pit notless than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level,connecting to theGalvanised earth lead wire 25 X 4mm Strip as Earthing Lead by means of bolts, nuts , check nuts and washers of galvanized iron andsteelearth wire protected by provision of GI lightgrade pipe40 mmbore including provision of concrete pitmade from PCC ( 1:2:4) type B-1 (using20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angleiron40 x 40 x 6 mm and handle of 6 mmdia MS barmade to shape, GI light grade 20 mmbore pipefor watering perforated atbottom, 1.50metre long placed on top edge of earth plate, common salt &charcoalfilling, withfixing arrangement , funnel, wire mesh and earthwork in hard/dense soil, returning filling in and removal of surplus soilto a distance notexceeding50 metres, all as perelectrical plate No 5 of SSR 2009 Part-I and connecting to Poles all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge. |
| 51 | Earth continuity Conductor or main earthing lead fixed to wall on batten or reccess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x 4 mm GI stripcomplete all as specified and as directed by Engineer-in-Charge. |
| 52 | S&F in Replacement of radiator(Engine Cool) with complete accessories, which is suitable for320 KVA KVA DG SET as Specified and directed by Engr In charge. |
| 53 | S&F in Replacement of radiator(Engine Cool) with complete accessories, which is suitable for63 KVA DG SET as Specified and directed by Engr In charge. |
| 54 | S&F inreplacement Control Card (PCB) ofexisting make and model suitable for DG set of capacity320 KVAcomplete all as specified and as directed by Engineer-in-Charge. Make : Kirloskar |
| 55 | S & F in replacement Alternator (Battery Charger) suitable for DG Set of capacity 63/100 KVA of existing make and Modal complete all as specified and directed |
| 56 | Draining all the U/S E Oil from the DG Sets Supply and filling the 20 W 40 E oil all as specified and as directed by Engr-in-charge.Make Servo, HP or any approved Make. |
| 57 | S&F in replacement AVR suitable for DG Set of capacity 320 KVA of DG set Make : Kirloskar/Greaves Cotton (existing make and model ) complete all as specified and directed by Engr-in-charge |
| 58 | S&F in replacement hoses of DG set of capacity 320 KVA Make : kirloskar/CG of existingsize complete all as specified and directed by Engr-in-charge |
| 59 | S&F in replacement hoses of DG set of capacity 63/100 KVA Make : kirloskar/CG of existingsize complete all as specified and directed by Engr-in-charge |
| 60 | M&L Cleaningof radiatorfor following capacity DG sets of capacity 320 by using anti scalent chemical and radiator cleaning solution (Ready to Wash) by pressurepump and brush and re-assembling after painting of the same complete all as directed. |
| 61 | Description all as per item Ser No. 60.00 here in before but DG set of capacity 63/100 KVA |