| 1 | M&L for overhauling/ servicing of ceiling fan of any size / sweep (i.e 1200/1400mm sweep) and make with and including dismantling, cleaning internally and externally and cleaning / lubricating of bearing / bushes using fresh lubricant (Oil grease) re-assembling, checking of split pin, hook assembly & hanging in same or other position and including provision of new cable fromceiling rose / connector to fan and testing for proper functioning complete including taking down from existing position all as specified and directed. |
| 2 | All as per ser item No. 1.00(here in before) but for exhaust fan of 225/300/380/450 mm sweep complete all as specified and directed. |
| 3 | M & Lfor painting of ceiling fan/Exhaust fans one coat, in situ with synthetic enamel paint by spraying including filling cavities with filler, after cleaning all dust etc with and including writing of MES No. as per existing complete all as specified and as directed. |
| 4 | Dismantling and taking out burnt copper winding from ceiling fan of sweep 1200mm of any make, model, type and rewinding the same with new super enameled copper wire of similar gauge and number of turns as per existing for full speed, including cleaning and greasing of bearing/bushes, taping, varnishing, heating and replacement of defective parts and reassembling of fan motor and refixing the fan after testing complete to the entire satisfaction of the Engineer-in-Charge. Note:- Contractor shall arrange repair/rewinding of ceiling fans work in RMS/Dimapur area with suitable winding machine and connected acessories. Spare parts will be measured andpaid under respective items. |
| 5 | Dismantling and taking out burnt copper winding from ceiling fan of sweep 1400mm any make, model, type and rewinding the same with new super enameled copper wire of similar gauge and number of turns as per existing for full speed, including cleaning and greasing of bearing/bushes, taping, varnishing, heating and replacement of defective parts and reassembling of fan motor and refixing the fan after testing complete to the entire satisfaction of the Engineer-in-Charge. Note:- Contractor shall arrange repair/rewinding of ceiling fans work in RMS/Dimapur area with suitable winding machine and connected acessories. Spare parts will be measured andpaid under respective items. |
| 6 | Dismantling and taking out burnt copper winding from Exhaust fan 300mm sweep of any model any make, any type and rewinding the same with new super enameled copper wire of similar gauge and number of turns as per existing for full speed, including cleaning and greasing of bearing/bushes, taping, varnishing, heating and replacement of defective parts and reassembling of fan motor and refixing the fan after testing complete to the entire satisfaction of the Engineer-in-Charge. Note:- Contractor shall arrange repair/rewinding ofExhaust fan 300mm sweep work in RMS/Dimapur area with suitable winding machine and connected acessories. Spare parts will be measured andpaid under respective items |
| 7 | Dismantling and taking out burnt copper winding from Exhaust fan 380-400mm sweep of any model any make, any type and rewinding the same with new super enameled copper wire of similar gauge and number of turns as per existing for full speed, including cleaning and greasing of bearing/bushes, taping, varnishing, heating and replacement of defective parts and reassembling of fan motor and refixing the fan after testing complete to the entire satisfaction of the Engineer-in-Charge. Note:- Contractor shall arrange repair/rewinding ofExhaust fan 380mm sweep work in RMS/Dimapur area with suitable winding machine and connected acessories. Spare parts will be measured andpaid under respective items. |
| 8 | Dismantling and taking out burnt copper winding from Exhaust fan 450mm sweep of any model any make, any type and rewinding the same with new super enameled copper wire of similar gauge and number of turns as exists for full speed, including cleaning and greasing of bearing/bushes, taping, varnishing, heating and replacement of defective parts and reassembling of fan motor and refixing the fan after testing complete to the entire satisfaction of the Engr-in-Charge. Note:- Contractor shall arrange repair/rewinding ofExhaust fan 450mm sweep work in RMS/Dimapur area with suitable winding machine and connected acessories. Spare parts will be measured andpaid under respective items |
| 9 | Dismantling and taking out burnt copper winding from wall mounted fan 400mm sweep of any model any make, any type and rewinding the same with new super enameled copper wire of similar gauge and number of turns as per existing for full speed, including cleaning and greasing of bearing/bushes, taping, varnishing, heating and replacement of defective parts and reassembling of fan motor and refixing the fan after testing complete to the entire satisfaction of the Engineer-in-Charge. Note:- Contractor shall arrange repair/rewinding ofwall mounted 400mm sweep work in RMS/Dimapur area with suitable winding machine and connected acessories. Spare parts will be measured andpaid under respective items. |
| 10 | Dismantling and taking out burnt copper winding from pedestal fan 400 mm sweep of any model any make, any type and rewinding the same with new super enameled copper wire of similar gauge and number of turns as per existing for full speed, including cleaning and greasing of bearing/bushes, taping, varnishing, heating and replacement of defective parts and reassembling of fan motor and refixing the fan after testing complete to the entire satisfaction of the Engineer-in-Charge. Note:- Contractor shall arrange repair/rewinding ofpedestal fan 400 mm sweep work in RMS/Dimapur area with suitable winding machine and connected acessories. Spare parts will be measured andpaid under respective items |
| 11 | M &LPCB board for exisitingBLDC ceiling fan any sweep and makeincluding taking down the unserviciable complete all as specified and directed. |
| 12 | M&L for replacement of stepped type electronic fan regulator flush type on the existing laminated sheet including taking down the existing unserviceable fan regulator complete all as specified and directed. |
| 13 | S&F modular fan step regulator, 120W - 2 modular completeall as specified and as directed. |
| 14 | Supply only fan capacitor of capacity 2.5 MFDcompleteall as specified and as directed. |
| 15 | Supply only fan capacitor of capacity 4.0 MFD (Oil filled) completeall as specified and as directed. |
| 16 | Supply only Ball bearing/Bush bearingsuitable for ceiling fan,of any sweep completeall as specified and as directed. . Makeof bearing-TATA,NBC,SKF (6201 to 6204) |
| 17 | Supply only fan clamp of MS including nut, bolt, rubber reel, split pin complete of suitable size 1200/1400 mm completeall as specified and as directed. |
| 18 | Supply only flexible wire, copper conductor,Twin twisted multicore cable 2 core High Quality twin core flat wire of size 40/.0076 Sqmm wire completeall as specified and as directed. |
| 19 | Supply only top/bottom canopy suitable for ceiling fan of any sweep, make, model and type completeall as specified and as directed. |
| 20 | Supply only down rod made out of GI tubing medium grade with both side thread & hole of 15mm two feet long completeall as specified and as directed. |
| 21 | Supply only set of 3 blade suitable for Ceiling fan 1200/1400mm sweep completeall as specified and as directed. |
| 22 | Dismantling of storage type water heater (Geyser) of 25/35/50 ltrs capacity, any make, vertical or horizontal type, mounted on wall by disconnecting electric and water supply connection and keeping the same in safe custody for carrying out necessary repair/replacement of UNSV parts/components including descaling of the geyser tank by using suitable liquid chemical and re-assambling & refixing the same all as directed by the Engineer-in-Charge. (Note: UNSV items for repairing shall be measured and paid seprately under respective item here-in- after as supply only). |
| 23 | Supply only following items for water heater and geyser of any type/ model and make all as directed by Engr-in-Charge. |
| 24 | Supply only Heavy duty PK Aqua 2 feet hot water connection for geyser hose pipe both cold and hot (set of two)water line with adopter and washer at both ends of the pipe. |
| 25 | Supply onlyIndicator lamp round/rectangular complete all as specified and as directed. |
| 26 | Supply only Thermostat for geyser 30 to 75 degree centigrade complete all as specified and as directed. |
| 27 | Supply only Auto cut-off electric water heater geyser temperature controlling sensor any capacity complete all as specified and as directed. |
| 28 | Supply only push type copper heating element of 1.5 KW capacity complete all as specified and as directed.. |
| 29 | Supply only push type copper heating element of 2 KW capacity complete all as specified and as directed.. |
| 30 | Supply only Glass wool for filling in between outer cell and container of geyser complete all as specified and as directed. |
| 31 | Supply only storage tank 25ltrs and including assemble with rubber, nuts, washers etcfor geyser of capacity 25 ltr, any make any type complete all as specified and as directed. |
| 32 | Supply only Storage tank 50ltrs and including assemble with rubber, nuts, washers etcfor geyser of capacity 50 ltr, any make any type complete all as specified and as directed. |
| 33 | Supply and fixing for Switch socket combination 5 pin,15 Amp multipurpose complete all as specified and as directed. |
| 34 | S & F 15 Amp plug Top suitable for 15 amp socket complete all as specified and as directed. |
| 35 | S & F in repairs 2.5 Sqmm wire 3 Core for geyser connection complete all as specified and as directed. |
| 36 | Geyser 25/50Ltrs capacity outer cover inclding upper/lower cover suitable size of any make complete all as specified and as directed. |
| 37 | Supply & fixing for Element Assembly (Glass coated ) suitable 25 Ltrs (GL WH models) including taking down complete all as specified and as directed. Make : Bajaj or equivalent |
| 38 | Supply and fixing for clamp Bajaj/Havells/Crompton geyser fixing suitable size complete all as specified and directed. |
| 39 | S & F of metal fasteners of 12mm diax100mm long for fixing geyser complete as specified and as directed. |
| 40 | S&F for DBOXx MCB protected socket PVC plastic base of size 46.5 x42.8 x26 CM with and including single pole MCB SP 25 Amps complete all as specified and directed. |