Public Facilities Related Work At33/11Kv S/S Kalindikunj, lucknow-Uttar Pradesh

Madhyanchal Vidut Vitran Nigam Limited has published Public Facilities Related Work At33/11Kv S/S Kalindikunj. Submission Date for this Tender is 21-04-2025. Paver Blocking Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

48710541
Public Facilities Related Work At33/11Kv S/S Kalindikunj
Open Tender
Indian
Uttar Pradesh
Lucknow
21-04-2025

Tender Details

Public Facilities Related Work At33/11Kv S/S Kalindikunj- 1 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.(15.56) 2 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)(4.1.10) 3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (4.1.2) 4 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand)(6.1.2) 5 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)(6.4.2) 6 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) (13.4.2) 7 Neat cement punning. (13.18) 8 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (10.2) 9 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. (5.22.6) 10 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (13.8) 11 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture(13.48.3) 12 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre(13.41.1) 13 Wiring for light point/ fan point/ exhaust fan point/ call bell /power point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C (1.10.3) 14 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C ( 1.17.12) 15 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. ( 10.5.1) 16 Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect.( 28.41) 17 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (1.14.2) 18 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire(1.14.3) 19 Supply and Fixing of 3 blade fan ofHavells platina 400 mm or equivalent including all material, T&Petc required for proper completion of work as approved by engineer in charge. (28.37) 20 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havellsor equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge(.28.38) 21 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately)Second class teak wood 35 mm thick shutters (9.5.1.1) 22 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete..Size of Tile 600x600 mm (11.41.2) 23 Providing and laying Ceramic glazed tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.(11.38) 24 Providing and Applying one coat of DI PRIMER for prime sealing (Addcon or Star equivalent make) over the prepared surface using a brush. if the surface is very porous two coats could be applied with a gap of 2-3 hours between each coat. one coat as per manufactures specifications including supply of all material, labour and T&P etc for proper completion of work as per direction of Engineer Incharge(NSI) 25 Cleaning, Repairing of visible cracks/pot holes/uneverness using polymerised motar (Addcon chemical or Star equivalent make) as per manufactures specifications including supply of all material, labour and T&P etc for proper completion of work as per direction of Engineer Incharge.(NSI) 26 Providing and applying after the primer coat is completely dried apply two coats of ENIROOF SPR®. It is recommended to apply the 2nd coat after the 1st coat is totally cured with GLASS FIBRE REINFORCEMENT embedded into 1st coat of ENIROOF SPR® while still wet. ENIROOF SPR® could be diluted up till 15 – 25 % for 1st coat and 10 – 15 % for 2nd coat to make material workable and get the desired coverage. Follow application instructions of KOSTER coating being installed. Embed KOSTER Glass Fiber Mesh into the fresh first layer. After the first layer has cured, cover with subsequent layers. Installed sheets of KOSTER Glass Fiber Mesh must overlap each other by at least 2 inches (ENIROOF SPR® Make) as per manufactures specifications including supply of all material, labour and T&P etc for proper completion of work as per direction of Engineer Incharge. (NSI) 27 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (17.1.1) 28 Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete.10 litre (full flush) capacity-coloured (17.19.2) 29 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps(17.7.1) 30 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge..15 mm nominal dia Pipes (18.8.1) 31 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge..20 mm nominal dia Pipes (18.8.2) 32 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(18.48) 33 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore(18.50.1) 34 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.(18.52.1) 35 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)(14.5.1) 36 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.(80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.)(16.91.2) 37 carpentar(0156) 38 Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser.b) for 1.5/ 2 H.P pump set single phase 19.31b 39 Supply & Installation ofsubmersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work.b) 1.5 HP outlet 40mm dia. or more, Head 71/36, Discharge 2000/6000 LPH (19.32 b) 40 Supply & fixing of steel wire rope forsubmersible pump including cost of labour, T&P and material required for completion of work. (19.34) 41 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever 0.63 mm thick with zinc coating not less than 275 gm/ m² (12.1.3) 42 all work shall be executed according to the approved drawing and specification. 43 the Quantities in the boq are tentative and may very as per requirement at site for which no claim or compensation shall be considered 44 rate quoted by the contractor shall be inclusive of all profit taxes and contingencies that may encountered at site. Only GST shall be paid extra as applicable 45 The drawings and design including architecture services 3D & elevation shall beprovided by the contractor at his own costand contractor will have to get it approved from department 46 ,Nothing shallbe payble in this regards 47 saftey norms must be followed by the contractor according to the labour law, in case of any accident all the liablity shall be borne by contractor 48 any recoveryproposed shall be recovered from the contractor 49 Contractor will have to submit program for all constrruction activities at the time of commencement of the work 50 In case of maintenance and repair work contractor will have to submit appropriate photographs of the same i.e.before commencement of each particular work and after completion of each particulat work

Key Value

Document Fees
INR 590 /-
EMD
INR 4000.0 /-
Tender Value
INR 1.94 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail