Housing Urban and Rular Development Government Departments Closing in 0 days TDR #48682195

Tender For Proposed Construction Of Meter And V.C.B. Room At Ttl Workshop At Ghatampur, District-Kanpur (U.P.)

Issued by Government Departments · ghatampur, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Apr 2025
0 days left
EMD
10000
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
ghatampur → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Proposed Construction Of Meter And V.C.B. Room At Ttl Workshop At Ghatampur, District-Kanpur (U.P.)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Apr-2025 DATE EXTENDED Date 28-Apr-2025

BOQ

Name of Work: Proposed Construction of Meter & V.C.B. Room at TTL Workshop At Ghatampur, District:-Kanpur (U.P.)
Sl. No. Item Description
1Proposed Construction of Meter & V.C.B. Room at TTL Workshop At Ghatampur, District:-Kanpur (U.P.)
2Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.all kinds of soil
3Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
4Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
51:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
6Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
7Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).Lintel of doors & window,sunshadesetc.
8Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).Slab.
9Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
10Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
11Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
12Providing and laying integral cement based water proofing treatment including preparationof surface as required for treatment of roofs, balconies, terraces etc consisting of followingoperations:(a) Applyinga slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoiningwallsupto300mm heightincludingcleaning the surface before treatment.\"(b) Layingbrickbatswithmortarusing broken bricks/brickbats25mmto115mmsizewith50%of cementmortar1:5(1cement: 5 coarsesand)admixed with water proofingcompoundconformingto IS : 2645 andapprovedbyEngineer-in-chargeover20mmthick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixedwith water proofing compoundconformingto IS : 2645 and approved by Engineer-in-chargeto required slope and treating similarly the adjoining walls upto 300 mm height includingroundingof junctionsof walls and slabs.\"\"(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofingcompoundconformingto IS : 2645 and approved by Engineerin- charge.(d)Finishingthesurfacewith20mmthickjointless cementmortarofmix1:4(1cement:4coarsesand) admixed with water proofing compound conforming to IS :2645andapprovedbyEngineerin-chargeincluding laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neatcementslurryandmakingpatternof 300x300mm square 3 mm deep.\"(e) The wholeterraceso finishedshallbe floodedwith water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
13Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
1415 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) In plinth.
1512 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
1615 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand)
17Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
18Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (40 mm flooring)
19Cement plaster skirting up to 30 cm height, with cement mortar1:3 (1 cement: 3 coarsesand),finishedwitha floating coat of neat cement. 18 mm thick
20Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
21Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
22Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
23Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
24Providing and fixing glass strips in joints of terrazo/ cement concrete floors.40 mm wide and 4 mm thick
25Mild steel or iron workofsmall sizes and sections suchas hold fast etc. ( when notincludedinan overall rates) wroughttorequiredfromincluding supply ofsteel anditswastage includingcostof bolts, nuts if required forandwelding, grinding and making holes as required completion of workfabricationofholesdoors, chaukhats nosing.
26Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
27Structural steel work Z-Sectionin single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Ground Floor
28Structural steel work Grill in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Ground Floor
29Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with (4.0mm thick float glass)4.0 mm thick glass panesGround Floor
30Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16mm
31Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x16mm
32Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm
33Centering and shuttering including strutting, propping etc. and removal of form for all heights : (a) Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick.
34(b) Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick
35Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
36Wiring for light/ Power plug with 2X4 sq. mm FRLS PVC insuleted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1Nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthingas required.
37Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (a) 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire
38(b) 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire
39(c) 2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire
40Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
41Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module
42Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 5/6 amps switch
43Supply & fixing of LED Tube Light with Metal heavy dutyBox type batten Light fitting 2 x 22 watt suitable for up to 2 x 22 watt LED Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.(CAT: AAA)
44Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way Double door (4 + 18)
45Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way Double door (4 + 12)
46Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.
47Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
48Supplying and fixing 40 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four pole
49Suplly and burring of safe Earthing Electrode T-39 Cu Copper Coated, Length 2000mm, outer pipe 76.3mm X 3.2 inner pipe 42.4mm X 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50kgs activated soil (BFC) capable of reucing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame withhinged cover & mansonry housing.(From electrode terminal to switch board, cost of 25x3 copper strip will be extra) Make: As approved in U.P.P.W.D & C.P.R.I. all respects.
50Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
51GST Extra as per applicable

AI Tender Summary

OUR REF NO 48682195
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 28-04-2025
Authority
Authority Name Uttar Pradesh Projects Corporation Limited
Work Description Proposed Construction Of Meter And V.C.B. Room At Ttl Workshop At Ghatampur, District-Kanpur (U.P.)
Basic Detail
Tender No 01/PM-10/UPPCL/2025-26
Bidding Type Tender
Location
City ghatampur
State Uttar Pradesh
Key Dates
Publish Date 22 Apr 2025
Submission Date 28 Apr 2025
Open Date 28 Apr 2025
Finance
Tender Value Ref. Documents
Tender Fee 3540
EMD 10000
Exemption Available
Document List
94a4df23-5439-4872-84f0-28681acd306c.html
BID2.pdf
BOQ_1857534.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 22, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 28, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Apr 28, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 28, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

94a4df23-5439-4872-84f0-28681acd306c.html

pdf

BID2.pdf

xls

BOQ_1857534.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender