Agriculture Government Departments Closing in 0 days TDR #48679800

Tender For S/I/C/T Of 03 Nos. 150 Ltr. Capacity Water Cooler, 4 Kva Steplizer, Construction Of Water Coolar Cage, Pipe Line Connection, Cabling Work At N.M.Y. Mohammadabad, Farrukhabad.

Issued by Government Departments · mohammadabad, Uttar Pradesh
Tender Value
4.41 Lakhs
Estimated cost
Bid Submission
05 May 2025
0 days left
EMD
44500
Bank guarantee accepted
Document Fee
1100
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
mohammadabad → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

S/I/C/T Of 03 Nos. 150 Ltr. Capacity Water Cooler, 4 Kva Steplizer, Construction Of Water Coolar Cage, Pipe Line Connection, Cabling Work At N.M.Y. Mohammadabad, Farrukhabad.

BOQ

Name of Work:S/I/C/T of 03 Nos. 150 Ltr. Capacity Water cooler, 4 KVA Steplizer, ConstructionofWater Coolar Cage, Pipe Line Connection, Cabling work at N.M.Y. Mohammadabad, Farrukhabad.
Sl. No. Item Description
1Supplyof 150 Liter capacity Water Coolar of Usha make with Refrigarator R-22 Model No. (SAR 150150G, SS304) havying cooling capacity 150 Liter with extra large stainless steel body with water tap 2 Nos complete in all respects. (App)
2Supply of 4 KVA copper wound Stabilizer range 140-280 with plug top complete in all respects.(App)
3Installation and Comissioning charges of Water Coolar incl. connection complete in all respects.
4Construction of 2.00m x 1.50 m x 2.80 m Water Coolar Cage made out of 50x50x5mm M.S. angle iron with 10 SWG welded wire mesh of size 1”x2”galvanized G I Sheet of 24 SWG on roof, top and side to protect the coolar from rain. The foundation of cage shall be of 0.15m in 1:2:4 cement concretebase and brick work in1:6 cement and fine sand. The flooring of the cage should be 6” base concrete in the ratio of 1:6:12 and 4.00mm thick and plaster in 1:2:4 plain including painting with aluminium paints. The job includes supply of all materials, Labour T&P required for proper completion of work. (As per civil schedule Analysis)
5S/F of Chlorinated Polyvinyl Chloride CPVC Pipes of 15mm dia cpvc Pipe for Water Coolar Fittings,clamps including all materials, Labour etc complete in all respects.
6S/F of Chlorinated Polyvinyl Chloride CPVC Pipes wash out pipe of 40mm dia cpvc Pipe for wastage water drain from Water Coolar connection complete in all respects.
7S/F of brass stop cock of approved make complete in all respects.
8S/F of brass bib cock of approved make complete in all respects.
9S/F of uplasticised PVC connection pipe with brass unions 30cm length 15mm dia PipeFittings including all materials, Labour etc complete in all respects.
10S/burying of 40 mm dia x 4.5 metres long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled up to 2 metre from the bottom complete with earthing lead of no. 6 to 8SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I., wire and pipe/will be extra) upto switch board, 30 cm square C.I. box with hinged cover masonry enclosure,funnel at top, alternate layers of charcol . coke and salt at least 150 mm thick al around etc. as per directions of Engineer-in-charge complete in all respects as per drawing.
11S/fixing of one number 8 to 6 SWG G.I. Wire in 15mm dia. G.I. Pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sandlabour. T & P required for proper completion of the work as directed at site.
12S/fixing of power plug with 15A/250 V flush typemodular switchand 5 pin 15A/250 V flush type universal socket on concealed M.S. box including supply of all materials labour T&C etc. required for proper complete in all respects
13S/F of 6 Amp to 32 Amp SPMCB (10 KA) C CurveCat A
14S/F of 6 Amp to 32 Amp. DPMCB (10 KA) C curveCat A
15S/F surface/flush mounting 4 way SPN distribution board with additional metal door without MCB complete in all respect and as directed at site. Cat B
16S/L of aluminim conductor PVC insulated armored, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by Engineer-In-Charge, complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc. (i) 10sqmm 2 core
17Supply and Hoisting ofsyntax or equivalent Make High Density Polyethylene sheenless moulded Tank and placing in position. The job is inclusive of all taxes, Labour, T&P and other material for proper completionof work as directedby Engineer in charge at site.

AI Tender Summary

OUR REF NO 48679800
AUTHORITY Government Departments
TENDER VALUE 4.41 Lakhs
LAST DATE 05-05-2025
Authority
Authority Name Rajya Krishi Utpadan Mandi Parishad
Work Description S/I/C/T Of 03 Nos. 150 Ltr. Capacity Water Cooler, 4 Kva Steplizer, Construction Of Water Coolar Cage, Pipe Line Connection, Cabling Work At N.M.Y. Mohammadabad, Farrukhabad.
Basic Detail
Tender No E/M/325/2025-2580
Bidding Type Tender
Location
City mohammadabad
State Uttar Pradesh
Key Dates
Publish Date 12 Apr 2025
Submission Date 05 May 2025
Open Date 06 May 2025
Finance
Tender Value 4.41 Lakhs
Tender Fee 1100
EMD 44500
Exemption Not Available
Document List
d8be8bd9-502e-4290-a7f8-d6fa792ab07f.html
Tendernotice_1.pdf
2580TenderNotice1T.pdf
BOQ_1857071.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 12, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
May 05, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 06, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

d8be8bd9-502e-4290-a7f8-d6fa792ab07f.html

pdf

Tendernotice_1.pdf

pdf

2580TenderNotice1T.pdf

xls

BOQ_1857071.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders