| 1 | Excavation for foundation in earth, soil of all types sand. grayeland soft murum including removing the excavated material up to a distance of 50 m beyond the building area & stacking and spreading as directed, dewatering. Preparing the bed for the foundation and necessary back filing ramming, watering including shoring and strutting etc complete (Lift upto 3 0 m.) By manual means |
| 2 | Providing and laying Cast in situ /Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water. Formwork, laying/ pumping, compacting, roughening them if special finish is to be provided. finishing if required and curing complete. With fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Panmixer) etc complete With natural sand/V S I quality Artificial Sand |
| 3 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer in charge in layers of 15 cm to 20 cm including watering and compaction etc. complete. |
| 4 | Supplying trap/granite/quartzite/gneiss stone metal of required size by bringing the boulders / Rubble at the road side breaking them to required gradation including conveying the boulders /Rubble and stacking the broken metal etc. complete (Prior approval of sample stack of broken metal by the Ex Engineer is necessary the date of approval will form part of the measurements) a) 40 mm Metal, By breaking Rubble ,obtained by blasting (Hand broken). |
| 5 | Supplying crusher broken 6 mm of trap/granite/quartzite / gneiss stone metal at the road side including conveying and stacking etc. complete as directed by Engineer in charge. |
| 6 | Providing pre constructional antitermite treatment as per I.S 6313 (Part--1) to the soil along the external face of building by punching holes of 1 2 of 1 5 C M diameter about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 liters per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper |
| 7 | Spreading 80/ 40 mm metal for road work including sectioning etc complete asdirected by Engineer in charge |
| 8 | Spreading hard murum/ soft murum/ gravel or kankar for side width complete |
| 9 | Providing and laying Cast in situ /Ready Mix cement concrete In M20 of trap/ granite/ quartzite/gneiss metal for bed blocks. foundation blocks and such other iterns including bailing out water. plywood/ steel formwork laying/ pumping compacting. roughening them if specal finish is to be provided finishing uneven and honey combed surface and curing etc. complete. The Cement Mortars 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shaft be covered by gunny bag. Plastic tarpaulin etc.(Wooden cantering gwill not be allowed.). with fully automatic micro Processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete With natural sand/VSI quality Artificial Sand |
| 10 | Providing and raying Cast in situ /Ready Mix cement concrete M20 of trap/granite/ quartzite/gneiss metal for R C.C. slab sand landings as per detailed designs and drawings including centering, formwork. cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finishes to be provided and curing etc complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Panmixer) etc. complete. With natural sand /V.S.I. quality Artificial Sand |
| 11 | Providing and fixing in position TMT-FE-500 bars reinforcement of various diameters for R.C.C. pile caps, footings. Foundations, slabs. Beams and columns, canopies staircases, newels. chajjas. Lintels, Pardies. Coping. Fins. Arches etc as per detailed design and drawings and schedules including cutting, bending, hooking the bars. binding with wires or tack welding and supporting as required completed. |
| 12 | Transportation of earth, soils, soft murum, hard Murum etc. work site including laoding, unloading etc. complete (1.00 km) |
| 13 | Providing sand faced plaster externally in cement mortar using approves screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete. |
| 14 | Providing and laying telephone black / Amba White / Cadburybrown I Ruby red / Ocean Brown granite stone of 18 io 20 mm thick for door frame/ dado/ window boxing etc On C.M. 1:6 including filling joints with polymer base filler nosing :he sharp edges wherever necessary. Curing. etc complete |
| 15 | Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 60 mm thickness of having a strength of 300 kg/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete |
| 16 | Providing and fixing steel frame door of angle 40 x 40 x 5 mm with 16 mm dia. mild steel bars horizontally at 10cm c/c for ventilator portion including iron hold fast for the fixing shutters including welding, painting, finishing etc. complete. |
| 17 | Providing and fixing steel window C.R.C. sheet as per I.S. 1513 : 1986. gauge sect. 65 x 40 x 25 mm shutter single sheet of 24 gauge single leaf joined by fusion welding at appropriate points with vertical grooves of 15 mm wide and 15 mm deep at a distance of 45 mm. The first and last rib should be 60 mm away from vertical edge of the shutter. the shutter shall be welded, with angle to from the periphery of the shutter. At the center of the frame there shall be angle welded to bifurcate the frame into segments with two leaf shutter square 12 mm square guard bars at 120 mm center with all accessories |
| 18 | Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 kg. to 20 kg. Per Sq.m.) |
| 19 | Fixing in position Road Junction/ Informatory Sign Board in ground with C.C.1:4:8 block of 60cm x 60cm x 75cm size including all leads complete. |
| 20 | Royalty charges for other minerals (royalty + Surcharge 2%) |
| 21 | Laboratory testing charges a) compressive strength of paving block |
| 22 | Laboratory testing charges a) compressive strength of c.c.Cube |
| 23 | Add 18% G.S.T. on cost of Work |
| 24 | Add 0.5% Labour insurance on cost of Work |