| Sl. No. | Item Description |
| 1 | Civil Works |
| 2 | Surface dressing of the ground including removing vegetation in -equalities not exceeding 15cm deep and disposal of rubbiesh, lead up to 50m and lift up to 1.5m. All kinds |
| 3 | Excavtion work by mechanical means (Hydraulic excavator ) / manual mean in foundation trenches or dranis (not exceedinf 1.5m in width or 10 sqm on plan), includingdressing od sides and ramming of bottoms, soil and disposal jod surplus excavated soils as directed, within a lead of 50m.2.9 ordinary rock |
| 4 | fillingavaliable excavated earth (excluding /rock in trenches, plinth, sides of foundations etc, in layers not exceeding 20cm in depth, consolidating each depostited layer by ramming and watering, lead up to 50m and lift upto1.5 |
| 5 | filling with avaliable fly ash and earth (excluding rock ) in trenches or embankment in layers ( each layer should not exceed 15,cm, ) with intermediate layer od compacted earth (soil density of 98%)after every four layers of compacted depth of fly ash, sides &top layer of filling shallbe done with earth having total minimum comjpacting thickness 30cm or as decided by engineer in charge, indclding compacting each layer by rolling / ramming and watering, all complete as per drawing and direction of engineer _ in charge |
| 6 | supplying and filling in plith with sand under floors, inculding watering, ramming consolidationg and dressingcomplete. |
| 7 | 3 treatment of soil under existing floor using cheminal emsulsion @ one litre per hole,300 mm a part including drilling 12mm diameter holes and plugging with cement mortar 1:2 (1cement:2course sand 0 to match the existing floor: woth chlorpyriphos / lindance E.C 20% with 1% cincentration |
| 8 | making plint protection 50mm thick of concrete 1:3:6 (1 cement :3coarse sand (zone -III):6 graded stone aggreate 20mm nominal size) over 75mm thick bed of dry brik ballast 40mm nominal size,well rammed and consolidated and grouted woth fine sand , inculding necessary excavation, lavelling & dressing % finising the top smooth |
| 9 | providing and lying in position cement concrete of specified grade excluding the cost of cenering and shuttering -All work up to plinth level :-1:4:8(1 cement :4 coarse sand (zone -III)8 graeded stone aggregate 40 mmnominal size) |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement: 6 coarse sand) |
| 11 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). 5.33.1 All works upto plinth level |
| 12 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). 5.33.2 All works above plinth level upto floor V level |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 15 | Foundations, footings, bases for columns |
| 16 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 17 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 18 | Suspended floors, roofs, landings, balconies and access platform |
| 19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class 7.5 in superstructure above plinth level up to floor V level in all shapes Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 20 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) |
| 21 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every thi course of half brick masonry |
| 22 | 15mm cement p;aster:1:6(1cement :6 fine sand )OUTER PKASTER |
| 23 | 12mm cement p;aster:1:6 (1cement :6 fine sand )INNER PKASTER |
| 24 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 10.13.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 25 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.10.15.1 FIXING WITH 15 3 |
| 26 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 27 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 10.11.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement:BLOCK 15X10X10LLCM of C.C 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size ) |
| 28 | Providing and fixing M.S. grills of required pattern in frames of windows etc.with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by Welding |
| 29 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. 9.51.2 With 12 mm mild steel U beading (Mosquito Jali). |
| 30 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. 9.51.2 With 12 mm mild steel U beading (Mosquito Jali). |
| 31 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 9.100.1 125 |
| 32 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 9.97.5 100x10 mm |
| 33 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 9.101.1 Single rubber stopper |
| 34 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms |
| 35 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 36 | Providing and laying vitrified Floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 37 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm |
| 38 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/sq.m including pointing the joints with white cement and matching pigments etc., complete. |
| 39 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 40 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 41 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth |
| 42 | Finishing walls with Acrylic Smooth exterior paint of required shade13.46.1 New work (Two or more coat applied @ 1.67 Itr/10 Sq M over and including priming coat of exterior primer applied @ 2.20 kg/10 Sq M) |
| 43 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour - Two coats |
| 44 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 45 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 10.26.1 M.S. tube |
| 46 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) |
| 47 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. (For the purpose of measurement the entire treated surface will be measured.) |
| 48 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 49 | Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS: 8183, density 24kg/m3, 50mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building. |
| 50 | Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface. 8.25.4 12 mm thick |
| 51 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 52 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 53 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05%) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required |
| 54 | Beautification |
| 55 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement: 2 stone dust) with an admixture of pigment matching the stone shade: (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately): 8.14.2 Red sand stone - Exposed face machine cut and table rubbed with rough backing. 8.14.2.1 70 mm thick |
| 56 | Electrical |
| 57 | Wiring for light point/fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 58 | Group B |
| 59 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 60 | Wiring for light/power plug with 2X4 sq.mm FRLS PVC insulated copper conductor single core cable in surface//recessed medium class PVC conduit alongwith 1 No. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 61 | Wiring for circuit/submain wiring alongwith earth wire the follpowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 62 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 63 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 64 | Supplying and fixing following mudularswitch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 65 | 2 way 5/6 A switch |
| 66 | 15/16 A switch |
| 67 | 6 pin 15/16 A socket outlet |
| 68 | TV antenna socket outlet |
| 69 | Bell push |
| 70 | Supplying and fixing following size/modules, Gi bos alongwith modullar base & cover plate for moduler switches in rocess etc. as required. |
| 71 | Supplying and fixing followin size/modules, GI box alongwith modular base & cover plate for mudular switches in recess etc. as required. |
| 72 | 1 or 2 Module (75mmX75mm) |
| 73 | 3 Module (100mmX75mm) |
| 74 | 4 Module (125mm×75mm): |
| 75 | Supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. |
| 76 | 1 or 2 module |
| 77 | 3 module |
| 78 | 4 module |
| 79 | Supplying and fixing call bell/buzzer suitable for single phase, 230 V, complete as required. |
| 80 | Installation, testing and commissioning of pre-wired, fluoresceunt figging/compact fluorescennt fitting of all types, completewith all accessories and tube/lamp etc. directly on ceilling/wall, including connections with 1.5 sq. mm FRLS PVC inculated, copper conductor, single core cable and earthing etc. as required. |
| 81 | Installation, testing and commissioning of ceiling fan, including wiring the down roads of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required |
| 82 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 83 | Upto 450 mm sweep |
| 84 | Extra for fixing the louvers/shutters complete with frame for a exhaust fan of all sizes. |
| 85 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed Steel/PVC conduit as required. |
| 86 | 1 run of cable |
| 87 | 2 run of cable |
| 88 | 3 run of cable |
| 89 | Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V, TPN MCB distrubution board of sheet steel, dust protected, duly protected, duly powder p ainted, inclusive of 200 A tinned copper bus bar common neutral link, earth bar din bar for mounting MCBs (but without MCBs and incomer) as required (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 90 | 12 way (4 + 36), Double door |
| 91 | Supplying and fixing 5 to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 92 | Single pole |
| 93 | Supplying and fixing rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 94 | 63 A |
| 95 | Supplying and fixing 20A, 240V SPN indupstrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, inn sheet steel enclosu8re, on surface or in recess with chained metal cover for the socket out let and complete with connections, testing and commmissioning etc. as required. |
| 96 | Supplying and fixing 20 A, 415 V, TPN Incustial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, TPMCB in sheet enclosure, on surface or I nrecess, commisiong etc. as required. |
| 97 | Providing and fixing M.C danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enmeled white on both sides and with inscription in single red colour on front side as required. |
| 98 | Providing and fixing circular/Hexagonal cast iron or M.S. Sheet box for ceiling fanclamp of internal dia 140 mm 73 mm height top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron/M.S sheet box by means of 3.3 mm dia round headed screws one lock at the corners clamp shall be made of 12 mm dia M.S bar bent to shape as per standard drawing. |
| 99 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories and providing masonry enoclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. |
| 100 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 101 | Laying of one number PVC inculated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 102 | upto 35 sq. mm |
| 103 | above 35 sq. mm and upto 95 sq. mm |
| 104 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC inculated and PVC sheathed / XLPE aluminuim conductor cable of 1.1 KV grade as required. |
| 105 | 3½ X 25 sq. mm (28mm) |
| 106 | 3½ X 50 sq. mm (35mm) |
| 107 | 3½ X 70 sq. mm (38mm) |
| 108 | Sanitary Work |
| 109 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid |
| 110 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required: 17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushing cisterr |
| 111 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.2 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 112 | Providing and fixing soil, waste and vent pipes : Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
| 113 | 100MM |
| 114 | 75MM |
| 115 | Providing and fixing plain bend of required degree. Sand cast iron S&S as per IS: 3989 |
| 116 | 100MM |
| 117 | 75MM |
| 118 | Providing and fixing collar: 17.57.1.2 Sand cast iron S&S as per IS - 3989 |
| 119 | 100mm |
| 120 | Providing and fixing single equal plain invert branch of required degree: 100x100x100 m cast iron S&S as per iron 1729 |
| 121 | Providing and fixing single equal plain invert branch of required degree: 75x75x75 mm Sand cast iron S&S as per IS - 1729 |
| 122 | Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete: 100x100x75 mm Sand cast iron S&S as p I5-3989 |
| 123 | Providing and fixing 600x450 mm beveled edge mirror of superior glas complete with 6 mm thick hard board ground fixed to wooden cleats washers complete. |
| 124 | proving and fixing terminal guard :100 mm 17.56.1.2 Sand cast iron S&S as per IS - 3989 |
| 125 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter: |
| 126 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter: |
| 127 | 100mm |
| 128 | Providing and fixing M.S.statys and clamps ,i/c cutting and making good the walls etc.. internal work -exposed on wall |
| 129 | 100mm |
| 130 | providing and fixing G.I pipes comlete with G.I fitting and clamps i/c cutting and making good the walls etc. internal work -exposed on wall |
| 131 | 15mm dia nonimal bore |
| 132 | 25mm dia nonimal bore |
| 133 | 50mm dia nonimal bore |
| 134 | proving and fixing ball valve (bress) od approved quality, high or low pressure, with plastic floats |
| 135 | 15mm nominal bore |
| 136 | Providing and fixing gun metal non- return valve of approved quality (screwed end) |
| 137 | 25 mm nominal bore- Horizontal |
| 138 | providing and fixing uplasticised PVC connection pipe with brass unions:45cm length |
| 139 | 15mm nominal bore |
| 140 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet |
| 141 | peoviding & fixing C.P bress bib cock parywaremake |
| 142 | n15 nominal bore |
| 143 | Providing and fixing PTMT pillar cock of approved quality and colour |
| 144 | 15mm nonimal bore,125 mm long foam flow,weighing not less then 120 gms |
| 145 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 |
| 146 | 15mm nonimal bore |
| 147 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 148 | Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms |
| 149 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 150 | 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 151 | Providing and fixing toilet paper holder : : |
| 152 | C.P bress |
| 153 | Retaning Wall |
| 154 | Earthwork in Hill Road (Hill Side Cutting) 1-1-1 Excavation in soil in Hilly Area by mechanical means 1-1-1-A Excavation in soil in Hilly Area by mechanical means Without useinng Dozer including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1 |
| 155 | Excavation in Hilly Areas in Ordinary Rock by mechanical means not requiring blasting (With out Dozer) Excavation in hilly area in ordinary rock not requiring blasting by mechanical means without using Dozer including cutting and trimming of slopes and disposal of cut material with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2. |
| 156 | Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and |
| 157 | Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in-charge, as per drawing and technical specifications Clause 305.1 of MORD |
| 158 | Removal of Unsuitable Soil with Disposal upto 1000 m Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11 |
| 159 | Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. required forproper completion of the work. as per drawings and technical specifications Clause 802, 803 |
| 160 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction |
| 161 | Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in-charge. (As per PWD Uttarakhand specifications |
| 162 | By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading | Materia 4-1-A-1 |
| 163 | Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. required forproper completion of the work, as per drawings and technical specifications Clause 802, 803, 1202 & 1203 |
| 164 | Providing and Laying of Interlocking Concrete Block Pavements of M-40 Grade having thickness 80 mm as per drawings and Technical Specification Clause 1504 |
| 165 | Cement plum Masonry with 40% plum & 60% 1:3:6 cement concrete including supply of all material, labour, T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203 of MORD Specifiction |
| 166 | Gate & Fencing |
| 167 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sq M on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. - All Kinds of Soil |
| 168 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: - 1:4:8 (1) Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size) |
| 169 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: - 1:4:8 (1) Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size) |
| 170 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: - 1:2:4 (1) cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size |
| 171 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 172 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 173 | Fire and Septic |
| 174 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sq M on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. - All Kinds of Soil |
| 175 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: - 1:4:8 (1) Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size) |
| 176 | Providing and laying in position spcified grad of reinforced cement concrete , excluding the cost of centering and shuttering, finishing and reinforcement - All work up to plinth level: - 1:1.5:3 (1) Cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 177 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 178 | Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases for columns |
| 179 | Brick work with common burnt clay F.P.S. (non modular) bricks of class 7.5 in foundationsand plinth in:6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 180 | 12mm cement p;aster:1:6 (1cement :6 fine sand ) INNER PKASTER |
| 181 | Providing and Supplying LED Wall Mounted Batten of SHAKTI LED Batten 36 Watts 1150 mm (SZSLAMX036) |
| 182 | Providing and Supplying 9W LED Bulb of SYSKA Led Bulb With Battery-is:16102, Warranty for free replacement 1 year- (SSK-SRL-9W) |
| 183 | Providing and Supplying Ceilling Light of ACEON Cool Day Light Aluminium Square LED surface ceilling Light- (ACEON-36-PL) |
| 184 | Providing and Supplying ceilling Fan of Rashmi Electric Ceilling Type Fan 1200 mm 5 Star (RLFANUHW1220MM) |