Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-04-2025 | third call | Date | 02-05-2025 |
| 2 | 22-04-2025 | second Call | Date | 28-04-2025 |
| Sl. No. | Item Description |
| 1 | KALAMWADI |
| 2 | SUB ESTIMATE NO.1Bore Well |
| 3 | Item No. 1 - Borewell drilling 150 mm dia. By DTH machine including transporting of machine at worksite. (as per Govt. approved rate) |
| 4 | Item No. 2 - Providing 180 mm dia. Pvc Casing Pipe 6 kg/cm2 & fixing borecap after completion of borewell (Govt. app. Rate) |
| 5 | Item No. 3 - Lowering & laying of 180 mm dia. Pvc Casing Pipe 6 kg/cm2 upto hardrock including Grouting (Govt. app. Rate)(Rate applicable for upto 12 m casing) |
| 6 | Item No. 4 - Lowering & laying of 180 mm dia. Pvc Casing Pipe 6 kg/cm2 upto hardrock including Grouting (Govt. app. Rate)(Rate applicable for above 12 m casing) |
| 7 | Item No. 5 - Yield Testing of borewell by 90 degree V Notch method for minimum 3 hrs continous. 150 mm Dia. |
| 8 | Item No. 6 - Providing India Mark II Handpump BIS marked fully hot dip galvanised deepwell Handpump complete unit with 12 Nos. of connecting Rod & 12 Nos. G. I. Pipes (Govt. approved rate) Installation charges. |
| 9 | Item No. 7 - Installation of India Mark II Hand pump installation Charges (Govt. app. Rate) |
| 10 | Excavation |
| 11 | c.c. |
| 12 | Item No. 8 - Providing & Placing 180 mm dia. P.v.c. Cap |
| 13 | Item No. 9 - Site Survey Charges (Govt. App. Rate) |
| 14 | SUB ESTIMATE NO.2Switch Room |
| 15 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 1/259) |
| 16 | Providing and laying in situ cement concrete in M – 15 (1:2:4) grade of trap /granite/quartzite/gneiss metal for foundation & bedding including bailing out water manually, form work compaction & curing, etc complete. |
| 17 | Providing Laterite stone masonry in cement mortar 1:6 in foundation and plinth including racking out joints when plastering is to be done/striking joints when no pplastering is to be done watering and scaffolding. |
| 18 | Providing Laterite stone masonry in cement mortar 1:6 in Superstructure including racking out joints when plastering is to be done/striking joints when no pplastering is to be done watering and scaffolding. |
| 19 | Providing and casiting in situ CC of trap /granite/quartzite/gneiss metal ofapprovedquality etc complete. |
| 20 | Providing cement palster 20 mm thick in twocoat in cement mortor 1:3 without neeru finish etc complete. |
| 21 | Filling the plinth & floors Murum bedding in trenches with approved murum from excavatyed materials form foundation15 cm. to 20 cm. layers including watering and compaction complete. |
| 22 | Providing and laying cement concrete flooring 40 mm thick wi th M15 cement concrete laid to proper level and slope in alternate bays including compact ion, fi lling joints, marking lines to give the appearance of t i les of 30 cm x 30 cm or other size laid diagonally / square etc finishing smooth (wi th ext ra cement ) in any colour as directed and cur ing etc. complete. With Natural Sand |
| 23 | Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc. complete |
| 24 | Providing and fixing in position aluminium openable window of any size as per detailed drawing and as directed by Engineer in charge with all necessary aluminum sections including necessary fixtures and fastening with 5 mm thick clear float glass etc. complete. a) With colour anodizing Note While arriving at the rate of item of item weight at 6.90 Kilogram/Square Metre is considered. |
| 25 | Providing and applying washable oil bound distemper of approved colour and shade to old/ new surfaces, in three coats including scaffolding, preparing the surface to receive the priming coat and finishing coat etc. complete. |
| 26 | Providing and fixing locking arrangement the standered qualityof lock for pump house, etc complete |
| 27 | Providing and fixing in position steel bar reinforcement of various diamenters for RCC piles, caps, footing, foundation, slabs, beams, columns, canopies, staircases, newels,chjjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking he bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire) |
| 28 | SUB ESTIMATE NO.3 : PUMPING MACHINERY |
| 29 | Providing, erecting and giving test of submersible pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard, thrust carbon / fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer\"s design. Antithrust stream lined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump. |
| 30 | Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. |
| 31 | Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil, over load element, and ON OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. |
| 32 | Providing , installing & commissioning main control pannel boardincluding V.meter & A. meter of suitable range single phase prevention 8 Nos. of phase indicater lamps with colour glass of 230 V rotary switch over load capacitor suitable for 7.50HP and 12.50BHP pump etc.complete. (Market rate) |
| 33 | Providing, erecting Pressure gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia G.I. Pipe. Pressure gauge shall be installed as directed, with tapping on rising main. |
| 34 | Providing tools for pumping. |
| 35 | Main wiring work from M. S. E. B. cut out to the panel board 4 core x 459 mm 1100 grade with I. S. I. Mark standard / Aluminum armored cable (94.1 p.36) |
| 36 | Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EA-EP |
| 37 | SUB ESTIMATE NO.4 : RISING MAIN |
| 38 | Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 /14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. |
| 39 | ProvidingG.I./P.V.C. HDPESpecialsasperstandard specifications&directionofinchargeEngineer.(5%of Item No.1&2) |
| 40 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete |
| 41 | Providing & supplying ISI mark CI D/F reflux valve (Non- returnvalve)offollowingdiaincludingalltaxes(central andlocal), railwayfreight, inspectionchargesunloading from railway wagon, loading into truck, transportation upto department stores/site, unloading, stacking etc. complete. reflux valves as per I.S.5312 part I (1984) |
| 42 | ProvidingandsupplyingAirvalvesasperIS-10845and MJP’s standard specifications of approved mark and quality offollowingdiametersincludingalltaxes (Central andlocal),railwayfright,inspectionchargesunloading fromrailwaywagons,loadingintotruck,transportation upto departmental stores/ site, unloading and stacking etc. complete. |
| 43 | Excavation for foundation/ pipe trenches in earth, soils of all types, sand gravel and soft murum, including removing the excavated material upto a distance of 50 meters & lifts as below, stacking & spreading as directed, normal dewatering,preparingthebedforfoundationand excluding backfilling, etc. complete. |
| 44 | Excavationforfoundation/pipetrenchesinhardmurum and boulders, W.B.M. road including removing the excavatedmaterialuptoadistanceof50Mbeyondthe area and lifts as below, stacking and spreading as directedbyEngineer-in-charge,normaldewatering, preparingthebedforfoundationandexcludingback- filling, etc. complete. |
| 45 | Excavation for foundation/ pipe trenches in soft rock and oldcementandlimemasonryfoundationasphaltroad including removing the excavated material upto a distance of50Mbeyond areaandliftsasbelow,stackingas directed by Engineer-in-charges, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
| 46 | Excavation for foundation / pipe trenches in hard rock by controlledblasting,includingtrimmingandlevellingthe bedbychisellingwherenecessaryandremovingthe excavatedmaterialandstackingitinmeasurableheaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete. Lift 0 to 1.5 M |
| 47 | Filling in plinth and floors murum bedding in trenches with approved murum from foundation 15 cm to 20 cm layers including watering and compaction complete. |
| 48 | Lowering, Laying and Jointing H. D. P. E./ M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II |
| 49 | Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves) |
| 50 | Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves) |
| 51 | Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves) |
| 52 | Lowering,Laying andfixing inproper alignmentand position all types of C.I. Air valves as directed by Engineer in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc complete. |
| 53 | Providingandfixinginpositionairvalveshaftincluding providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providingPCCblockofM-150concrete150mmthick aroundtheairvalveteeincludingencasingofvertical shaft in PCC M-150 as shown in type design together with providingandmakingflangedjointswhereverrequired and fixing of air valve over the shaft excluding cost of air valve and branch flanged air valve tee. etc. complete as per type design and as directed by Engineer-in-charge for following diameters of pipe lines (type design attached.) |
| 54 | ProvidingandconstructingB.B.masonryvalvechamber with 15 cm thick 1:3:6 proportion PCC bedding, including excavation, B.B. masonry in C.M. 1:5proportion 12 mm thickcementplasterincm1:4proportiononbothsides with providing and fixing C.I. manhole frame and cover in RCC1:2:4copingorcmthickslabetc.completeas directed by Engineer-in-charge. |
| 55 | Refillingthetrencheswithavailableexcavatedstuffwith soft materialfirst over pipeline andthen hardmaterial in 15cmlayerswithallleadsandliftsincluding consolidation, surcharging, etc. complete |
| 56 | Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. |
| 57 | Giving satisfactory hydraulic testing of following C.I. D / F Reflex valves, Butterfly valves and Sluice valves. |
| 58 | Sluice valves 50 mm Dia. |
| 59 | Reflux valves 50 mm Dia |
| 60 | SUB ESTIMATE NO.5 : SINTEX TANK AND PLATFORM |
| 61 | Item No.1: Excavation for foundation / pipe trenches in hard murum and boulders W.B.M. roadincluding removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
| 62 | Item No.2: Providing and laying in situ cement concrete in proportion M-150 of trap metal for foundation and bedding including bailing out water manually, formwork, compacting and curing … etc. complete. |
| 63 | Item No 3 : ProvidingLaterite stone masonry in cement morter 1:6 in foundation and plinth including striking joints on the unexposed faces and watering complete ( Laterite stone six sides cut and thickness of morter joints shall be 12 mm max ) etc comp. |
| 64 | Item No 4 : Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc complete. |
| 65 | Item No 5 : Providing External cement plaster 20mm. thick in Single coats in cement mortar 1:3 withoutneeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. |
| 66 | Item No 5 : Providing hoisting and fixing in position high density polythylene UV stabilized double layered conforming to IS 12701 water storaje tank with necessary connections testing etc complete complete |
| 67 | SUB ESTIMATE NO.6 : DISTRIBUTION SYSTEM |
| 68 | Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i.e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. |
| 69 | 10% of cost of pipes shall be considered for cost of PVC/HDPE specials for estimate purpose only. |
| 70 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete |
| 71 | Sluice valves 50 mm Dia |
| 72 | Ball Valve (Brass)50mm |
| 73 | Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete. |
| 74 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) |
| 75 | Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-3/259) |
| 76 | Excavation for foundation/ pipe trenches in soft rock and oldcementandlimemasonryfoundationasphaltroad including removing the excavated material upto a distance of50Mbeyond areaandliftsasbelow,stackingas directed by Engineer-in-charges, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
| 77 | Excavation for foundation / pipe trenches in hard rock by controlledblasting,includingtrimmingandlevellingthe bedbychisellingwherenecessaryandremovingthe excavatedmaterialandstackingitinmeasurableheaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete. Lift 0 to 1.5 M |
| 78 | Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263) |
| 79 | Lowering, Laying and Jointing H. D. P. E./M.D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II |
| 80 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) |
| 81 | Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete. (for all class of valves) |
| 82 | Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type design attached.) |
| 83 | Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge. |
| 84 | Refillingthetrencheswithavailableexcavatedstuffwith soft materialfirst over pipeline andthen hardmaterial in 15cmlayerswithallleadsandliftsincluding consolidation, surcharging, etc. complete |
| 85 | Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. |
| 86 | ProvidingandmakingHDPE/PVC pipeconsumer serviceconnectionondistributionmainbydrilling holes with suitable means, including all labour. HDPE/PVCpipeofrequiredlengthwithorwithout roadcrossingasdescribedbelowincluding saddle/clampsaddleofsuitablematerial---as directed by Engineer in charge. |
| 87 | Providingandfixingboarddisplayinginformation, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangularshapeof1.20mx0.90msize made out 18 gauge (1.25 mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stoveenamelonbacksideandborder/messages /symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x35 x3 mm frame with properly cross braced M.S.angles of size 35 mm x 35 mm x 3 mm duly painted including Two M.S.angle iron posts of size 65 mmx 65 mmx 6 mm, 3.65mlongpaintedwithalternateblackandwhite bandsof25cmwidthincludingallfixturesetc.and fixing the boards in 1:4:8 concrete block of size 60 cm x60cmx75cmincluding,excavation,refilling, transportation,andlabouretccomplete.Spec. Number As directed by Engineer in Charge MORTH 801 |
| 88 | SUB ESTIMATE NO.7 : MSEB WORK |
| 89 | Providing & streching transmission line & making Additional electric load connection to Head works, including all charges as per MSEB rule |
| 90 | SUB ESTIMATE NO.8 : TRIAL RUN |
| 91 | Commissioning, running and maintaining the scheme to quantities, rated capacity, including manning necessary personnel such as operator, valveman, etc. as per requirements of the scheme and who should also administer chemical dose for a period of 1 month for individual scheme and for regional scheme, together with training of personnel spared by MJP / Local Body and handing over the scheme to Local Body after completion of the above period as directed by Engineer-in-charge. |
| 92 | BRAMHANWADI |
| 93 | SUB ESTIMATE NO.1 BANDHARA REPAIRING |
| 94 | Item No. 1 :-Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc. |
| 95 | Item No. 2 :-Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for etc. complete |
| 96 | Item No.3 :-Excavation for foundation / pipe trenches in hard rock by blasting including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed etc.complete |
| 97 | Item No.4:- Providing and laying in situ Cement concrete in proporation .... of trap metal for foundation and bedding, including balling out water manually, formwork, compacting and curing etc. complete. |
| 98 | Item No. 5:- Providing & costing inconstructingin situ. C.C of trap granite/ quartzite / gneiss/ metal of approved quality of R.C.C. work as per detailed drawing & design or as directed by Engg. in charge including dewatering , ceterind from work,compacting, finishingthe formed surface withC.M. 1:3 of sufficient minimum thickness to give a smooth & even surface wherever necessary or roughening if spetial finish is to be provided & curing etc. complete. ( By weight batching & mix design for M-250 & M-300 only use of L&T, ACC Ambuja, Birla Gold, Manikgad, Rajashree etc. cement is permitted excluding M.S or Tor reinforcement in R.C.C. M-200grade. |
| 99 | Item No.6:- Providing & fixing in position steel bar reinforcement of various diameters for R.C.C. Pipes,caps,footing, foundation,slab,beams,columns,canopies, staircase, newels,chajjas, lintels,pardies,coping,fine arches etc. as per detailed designs, drawing & schedule s including cutting,bending,hooking the bars,bindingwith wires or tack welding & supporting as required etc. complete (including cost of binding wire). Tor Steel |
| 100 | ItemNo.7- Dewatering the excavatyed trenches and pools of water by using pumps and other devices including disposing of the water to safe distance as directed by Engineer-in-Charge (including cost of machinerylabour fuel )etc complete. |
| 101 | SUB ESTIMATE NO.2 DISTRIBUTION SYSTEM |
| 102 | Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i.e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. |
| 103 | 10% of cost of pipes shall be considered for cost of PVC/HDPE specials for estimate purpose only. |
| 104 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete |
| 105 | Sluice valves 50 mm Dia |
| 106 | Ball Valve (Brass)50mm |
| 107 | Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete. |
| 108 | Lowering, Laying and Jointing H. D. P. E./M.D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II |
| 109 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) |
| 110 | Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete. (for all class of valves) |
| 111 | Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type design attached.) |
| 112 | Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge. |
| 113 | Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. |
| 114 | Providingandfixingboarddisplayinginformation, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangularshapeof1.20mx0.90msize made out 18 gauge (1.25 mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stoveenamelonbacksideandborder/messages /symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x35 x3 mm frame with properly cross braced M.S.angles of size 35 mm x 35 mm x 3 mm duly painted including Two M.S.angle iron posts of size 65 mmx 65 mmx 6 mm, 3.65mlongpaintedwithalternateblackandwhite bandsof25cmwidthincludingallfixturesetc.and fixing the boards in 1:4:8 concrete block of size 60 cm x60cmx75cmincluding,excavation,refilling, transportation,andlabouretccomplete.Spec. Number As directed by Engineer in Charge MORTH 801 |
| 115 | BOUDHHAWADI |
| 116 | SUB ESTIMATE NO.1 : RCC WELL |
| 117 | Item No. 1 :-Desilting the Supply Well, Intake Well / Head Works, Sump of water supply / sewerage works etc. in wet or dry condition including lifts upto 9 M and lead upto 150 M as required beyond the work site, stacking, spreading, including necessary guarding, etc. complete, as directed by Engineer-in-charge. |
| 118 | Item No.2:- Providing and laying in situ Cement concrete in proporation .... of trap metal for foundation and bedding, including balling out water manually, formwork, compacting and curing etc. complete. |
| 119 | Item No. 3:- Providing & costing inconstructingin situ. C.C of trap granite/ quartzite / gneiss/ metal of approved quality of R.C.C. work as per detailed drawing & design or as directed by Engg. in charge including dewatering , ceterind from work,compacting, finishingthe formed surface withC.M. 1:3 of sufficient minimum thickness to give a smooth & even surface wherever necessary or roughening if spetial finish is to be provided & curing etc. complete. ( By weight batching & mix design for M-250 & M-300 only use of L&T, ACC Ambuja, Birla Gold, Manikgad, Rajashree etc. cement is permitted excluding M.S or Tor reinforcement in R.C.C. M-200grade. |
| 120 | 1) R.C.C. M-200for Beam |
| 121 | 2) R.C.C. M-200 for vertical wall below GL |
| 122 | 2) R.C.C. M-200 for vertical wall below GL |
| 123 | 3) R.C.C. M-200 for vertical wall |
| 124 | Item No.4:- Providing & fixing in position steel bar reinforcement of various diameters for R.C.C. Pipes,caps,footing, foundation,slab,beams,columns,canopies, staircase, newels,chajjas, lintels,pardies,coping,fine arches etc. as per detailed designs, drawing & schedule s including cutting,bending,hooking the bars,bindingwith wires or tack welding & supporting as required etc. complete (including cost of binding wire). Tor Steel |
| 125 | Itemno:5- Providing & laying weep holes of 80 mmAC/PVC pipe as per drawing for abutment returns, return wallsetc. complete. |
| 126 | Item No. 6 :- Providing structural steel work in rolled sections like joists, channels, angles, tees, etc. as per detailed designs and drawings including fixing in position without connecting plates, braces, etc. and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, etc. complete. (Bd - C - 2/275) |
| 127 | Item No. : 7 Providing and fixing M. S. chequerred plate flooring of following thickness supported on M. S. angles (25 x 25 x 5 mm size) including welding, cutting and fabricating the plates to the required square or rounding shape, making holes in the plate, including providing and applying 3 coats of anticorrosive paint, etc. complete as directed by Engineer-in-charge. |
| 128 | ItemNo.8- Dewatering the excavatyed trenches and pools of water by using pumps and other devices including disposing of the water to safe distance as directed by Engineer-in-Charge (including cost of machinerylabour fuel )etc complete. |
| 129 | Itemno:9 - Reffiling the trenches with approved excavated material from foundation in 15cm to 20cm layers including watering and compaction etc. complete. |
| 130 | SUB ESTIMATE NO.2 SWITCH ROOM |
| 131 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 1/259) |
| 132 | Providing and laying in situ cement concrete in M – 15 (1:2:4) grade of trap /granite/quartzite/gneiss metal for foundation & bedding including bailing out water manually, form work compaction & curing, etc complete. |
| 133 | Providing Laterite stone masonry in cement mortar 1:6 in foundation and plinth including racking out joints when plastering is to be done/striking joints when no pplastering is to be done watering and scaffolding. |
| 134 | Providing Laterite stone masonry in cement mortar 1:6 in Superstructure including racking out joints when plastering is to be done/striking joints when no pplastering is to be done watering and scaffolding. |
| 135 | Providing and casiting in situ CC of trap /granite/quartzite/gneiss metal ofapprovedquality etc complete. |
| 136 | Providing cement palster 20 mm thick in twocoat in cement mortor 1:3 without neeru finish etc complete. |
| 137 | Filling the plinth & floors Murum bedding in trenches with approved murum from excavatyed materials form foundation15 cm. to 20 cm. layers including watering and compaction complete. |
| 138 | Providing and laying cement concrete flooring 40 mm thick wi th M15 cement concrete laid to proper level and slope in alternate bays including compact ion, fi lling joints, marking lines to give the appearance of t i les of 30 cm x 30 cm or other size laid diagonally / square etc finishing smooth (wi th ext ra cement ) in any colour as directed and cur ing etc. complete. With Natural Sand |
| 139 | Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc. complete |
| 140 | Providing and fixing in position aluminium openable window of any size as per detailed drawing and as directed by Engineer in charge with all necessary aluminum sections including necessary fixtures and fastening with 5 mm thick clear float glass etc. complete. a) With colour anodizing Note While arriving at the rate of item of item weight at 6.90 Kilogram/Square Metre is considered. |
| 141 | Providing and applying washable oil bound distemper of approved colour and shade to old/ new surfaces, in three coats including scaffolding, preparing the surface to receive the priming coat and finishing coat etc. complete. |
| 142 | Providing and fixing locking arrangement the standered qualityof lock for pump house, etc complete |
| 143 | Providing and fixing in position steel bar reinforcement of various diamenters for RCC piles, caps, footing, foundation, slabs, beams, columns, canopies, staircases, newels,chjjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking he bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire) |
| 144 | SUB ESTIMATE NO.3 PUMPING MACHINERY |
| 145 | Providing, erecting and giving test of submersible pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard, thrust carbon / fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer\"s design. Antithrust stream lined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump. |
| 146 | Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. |
| 147 | Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil, over load element, and ON OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. |
| 148 | Providing , installing & commissioning main control pannel boardincluding V.meter & A. meter of suitable range single phase prevention 8 Nos. of phase indicater lamps with colour glass of 230 V rotary switch over load capacitor suitable for 7.50HP and 12.50BHP pump etc.complete. (Market rate) |
| 149 | Providing, erecting Pressure gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia G.I. Pipe. Pressure gauge shall be installed as directed, with tapping on rising main. |
| 150 | Providing tools for pumping. |
| 151 | Main wiring work from M. S. E. B. cut out to the panel board 4 core x 459 mm 1100 grade with I. S. I. Mark standard / Aluminum armored cable (94.1 p.36) |
| 152 | Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EA-EP |
| 153 | SUB ESTIMATE NO.4 RISING MAIN |
| 154 | Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 /14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. |
| 155 | ProvidingG.I./P.V.C. HDPESpecialsasperstandard specifications&directionofinchargeEngineer.(5%of Item No.1&2) |
| 156 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete |
| 157 | Providing & supplying ISI mark CI D/F reflux valve (Non- returnvalve)offollowingdiaincludingalltaxes(central andlocal), railwayfreight, inspectionchargesunloading from railway wagon, loading into truck, transportation upto department stores/site, unloading, stacking etc. complete. reflux valves as per I.S.5312 part I (1984) |
| 158 | ProvidingandsupplyingAirvalvesasperIS-10845and MJP’s standard specifications of approved mark and quality offollowingdiametersincludingalltaxes (Central andlocal),railwayfright,inspectionchargesunloading fromrailwaywagons,loadingintotruck,transportation upto departmental stores/ site, unloading and stacking etc. complete. |
| 159 | Excavation for foundation/ pipe trenches in earth, soils of all types, sand gravel and soft murum, including removing the excavated material upto a distance of 50 meters & lifts as below, stacking & spreading as directed, normal dewatering,preparingthebedforfoundationand excluding backfilling, etc. complete. |
| 160 | Excavationforfoundation/pipetrenchesinhardmurum and boulders, W.B.M. road including removing the excavatedmaterialuptoadistanceof50Mbeyondthe area and lifts as below, stacking and spreading as directedbyEngineer-in-charge,normaldewatering, preparingthebedforfoundationandexcludingback- filling, etc. complete. |
| 161 | Excavation for foundation/ pipe trenches in soft rock and oldcementandlimemasonryfoundationasphaltroad including removing the excavated material upto a distance of50Mbeyond areaandliftsasbelow,stackingas directed by Engineer-in-charges, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
| 162 | Excavation for foundation / pipe trenches in hard rock by controlledblasting,includingtrimmingandlevellingthe bedbychisellingwherenecessaryandremovingthe excavatedmaterialandstackingitinmeasurableheaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete. Lift 0 to 1.5 M |
| 163 | Filling in plinth and floors murum bedding in trenches with approved murum from foundation 15 cm to 20 cm layers including watering and compaction complete. |
| 164 | Lowering, Laying and Jointing H. D. P. E./ M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II |
| 165 | Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves) |
| 166 | Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves) |
| 167 | Lowering,Laying andfixing inproper alignmentand position all types of C.I. Air valves as directed by Engineer in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc complete. |
| 168 | Providingandfixinginpositionairvalveshaftincluding providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providingPCCblockofM-150concrete150mmthick aroundtheairvalveteeincludingencasingofvertical shaft in PCC M-150 as shown in type design together with providingandmakingflangedjointswhereverrequired and fixing of air valve over the shaft excluding cost of air valve and branch flanged air valve tee. etc. complete as per type design and as directed by Engineer-in-charge for following diameters of pipe lines (type design attached.) |
| 169 | ProvidingandconstructingB.B.masonryvalvechamber with 15 cm thick 1:3:6 proportion PCC bedding, including excavation, B.B. masonry in C.M. 1:5proportion 12 mm thickcementplasterincm1:4proportiononbothsides with providing and fixing C.I. manhole frame and cover in RCC1:2:4copingorcmthickslabetc.completeas directed by Engineer-in-charge. |
| 170 | Refillingthetrencheswithavailableexcavatedstuffwith soft materialfirst over pipeline andthen hardmaterial in 15cmlayerswithallleadsandliftsincluding consolidation, surcharging, etc. complete |
| 171 | Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. |
| 172 | Giving satisfactory hydraulic testing of following C.I. D / F Reflex valves, Butterfly valves and Sluice valves. |
| 173 | Sluice valves 50 mm Dia. |
| 174 | Reflux valves 50 mm Dia |
| 175 | SUB ESTIMATE NO.5 SINTEX TANK AND PLATFORM |
| 176 | Item No.1: Excavation for foundation / pipe trenches in hard murum and boulders W.B.M. roadincluding removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
| 177 | Item No.2: Providing and laying in situ cement concrete in proportion M-150 of trap metal for foundation and bedding including bailing out water manually, formwork, compacting and curing … etc. complete. |
| 178 | Item No 3 : ProvidingLaterite stone masonry in cement morter 1:6 in foundation and plinth including striking joints on the unexposed faces and watering complete ( Laterite stone six sides cut and thickness of morter joints shall be 12 mm max ) etc comp. |
| 179 | Item No 4 : Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc complete. |
| 180 | Item No 5 : Providing External cement plaster 20mm. thick in Single coats in cement mortar 1:3 withoutneeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. |
| 181 | Item No 6 : Providing hoisting and fixing in position high density polythylene UV stabilized double layered conforming to IS 12701 water storaje tank with necessary connections testing etc complete complete |
| 182 | SUB ESTIMATE NO.6 DISTRIBUTION SYSTEM |
| 183 | Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i.e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. |
| 184 | 10% of cost of pipes shall be considered for cost of PVC/HDPE specials for estimate purpose only. |
| 185 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete |
| 186 | Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete. |
| 187 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) |
| 188 | Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-3/259) |
| 189 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-incharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) |
| 190 | Excavation for foundation / pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete. (Bd-A-5/259) |
| 191 | Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263) |
| 192 | Lowering, Laying and Jointing H. D. P. E./M.D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II |
| 193 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) |
| 194 | Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete. (for all class of valves) |
| 195 | Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type design attached.) |
| 196 | Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge. |
| 197 | Refillingthetrencheswithavailableexcavatedstuffwith soft materialfirst over pipeline andthen hardmaterial in 15cmlayerswithallleadsandliftsincluding consolidation, surcharging, etc. complete |
| 198 | Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. |
| 199 | Providingandfixingboarddisplayinginformation, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangularshapeof1.20mx0.90msize made out 18 gauge (1.25 mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stoveenamelonbacksideandborder/messages /symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x35 x3 mm frame with properly cross braced M.S.angles of size 35 mm x 35 mm x 3 mm duly painted including Two M.S.angle iron posts of size 65 mmx 65 mmx 6 mm, 3.65mlongpaintedwithalternateblackandwhite bandsof25cmwidthincludingallfixturesetc.and fixing the boards in 1:4:8 concrete block of size 60 cm x60cmx75cmincluding,excavation,refilling, transportation,andlabouretccomplete.Spec. Number As directed by Engineer in Charge MORTH 801 |
| 200 | SUB ESTIMATE NO.7 MSEB CHARGES |
| 201 | Providing & streching transmission line & making Additional electric load connection to Head works, including all charges as per MSEB rule |
| 202 | SUB ESTIMATE NO.8 TRIAL RUN |
| 203 | Commissioning, running and maintaining the scheme to quantities, rated capacity, including manning necessary personnel such as operator, valveman, etc. as per requirements of the scheme and who should also administer chemical dose for a period of 1 month for individual scheme and for regional scheme, together with training of personnel spared by MJP / Local Body and handing over the scheme to Local Body after completion of the above period as directed by Engineer-in-charge. |
| 204 | Add 18% GST |
| 205 | Add 4% Administration Charges |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy