| 1 | Carriage of Various size PCC Poles from store center or from any other place to the respective site of work Distence up to 75 km through the Kachha Pacca road including the work of its loading & unloading at the respective ends also including the work of its dragging etc. and also including the cost of labour, T & P and carrier etc. required for proper completion of work. |
| 2 | Carriage of Various size ST Poles (9 Mtr /11Mtr/ 13Mtr ) from store center or from any other place to the respective site of work Distence up to 75 km through the Kachha Pacca road including the work of its loading & unloading at the respective ends also including the work of its dragging etc. and also including the cost of labour, T & P and carrier etc. required for proper completion of work. |
| 3 | Carriage of Line material viz. Weasel/Rabbit/Racoon /Dog Conductor, G.I. earth wire, cross arm, angle, channel, Cable Boxes, Static meter insulators, clamps and other line material from store center or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends also including the work of its dragging etc. and also including the cost of labour, T & P and carrier etc. required for proper completion of work. |
| 4 | Erection ofP.C.C double pole including the work of complete H.T. fittings as per RESPO manual and as per direction of engineer Incharge including the cost of labour, T & P and carrier etc. required for proper completion of work. The support shall be grouted with cement, sand and brick ballast/stone ballast In ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement. |
| 5 | Erection ofP.C.C Single pole including the work of complete H.T. fittings as per RESPO manual and as per direction of engineer Incharge including the cost of labour, T & P and carrier etc. required for proper completion of work. The support shall be grouted with cement, sand and brick ballast/stone ballast In ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement. |
| 6 | Erection of S.T.P Single pole including the work of complete H.T. fittings as per RESPO manual and as per direction of engineer Incharge including the cost of labour, T & P and carrier etc. required for proper completion of work. The support shall be grouted with cement, sand and brick ballast/stone ballast In ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement. |
| 7 | Renozzling of Damaged stay set as per RESPO manual and also including the cost of all grouting material, labour, T & P etc. required for proper completion of work. |
| 8 | Dismentling of Rusted Weasal/Racoon /DOG conductor wire and G.I Wire & safe carriage of scrap material back to store as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carries etc. required for proper completion of work. |
| 9 | Laying, Sagging, Stringing, Binding and Jumpering etc. of Weasal conductor in new erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carries etc. required for proper completion of work. |
| 10 | Re-Sagging, of old Weasal conductor in pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carries etc. required for proper completion of work. |
| 11 | Laying, Sagging, Stringing, Binding and Jumpering etc. of Rabbit conductor as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carries etc. required for proper completion of work. |
| 12 | Re-Sagging, ofDOG conductor as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carries etc. required for proper completion of work. |
| 13 | Laying/Strengthening of Damaged LT ABC ( 3X120+1X95+1X16)As per respo manual |
| 14 | Laying/Strengthening of Damaged LT ABC ( 3X50+1X35+1X16)As per respo manual |
| 15 | Laying/Strengthening of Damaged LT ABC ( 3X95+1X70+1X16)As per respo manual |
| 16 | Laying/Strengthening of Damaged 11 KV XLPE 3X185 SqMM As per respo manual |
| 17 | Refilling of freash T/F Oil including Carrige of oil drum from Panki Store to the respective Site as per RESPO Norms |
| 18 | Replacement/Erection of damaged Distribution Box 3 Phase |
| 19 | Guarding of 11 K.V. Line Crossing |
| 20 | Supply & erection of Nut & Bolt for Insulator as per RESPO Norms. |
| 21 | Allingment of Tillted Pole to Complete Line as per RESPO Norms. |
| 22 | Repairing of double pole to complete HT line fitting as per RESPO Norms. |
| 23 | Laying/Strengthening of LT ABC ( 1X16) & 4x16 Armourd/Different Size Cable As per respo manual |
| 24 | Trimming of Tree Branches in New/existing 11 K.V Line. |
| 25 | Repairing of damaged Cable Jointing Kit without Supply |
| 26 | Supply & erection of Aluminium Lug 70 Sqmm as per RESPO Norms. |
| 27 | Supply & erection of Aluminium Lug 120 Sqmm as per RESPO Norms. |
| 28 | Supply & erection of Aluminium Lug 240 Sqmm as per RESPO Norms. |
| 29 | Supply & erection of T/F clamp as per RESPO Norms. |
| 30 | Supply & erection of Loop Insulator as per RESPO Norms. |
| 31 | Supply & erection of Different Types of Clamps as per RESPO Norms. |