| 1 | Demolition of cement concrete of any type or description ofLT pole complete all as specified and directed at site |
| 2 | Dismantlingofsteel poles/ struts,any size complete all as specified and directed at site. |
| 3 | Supply and fixing steel tubular pole, swaged, complete with cast iron base plate, finial taper plug,bolts, nuts, washer and screws including painting with two coats of of aluminium paints over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-22 (8.5 meter long) complete all as specified and directed.Note - Earthwork and PCC shall bemeasured and paid seperately under respective items. |
| 4 | Supply and fixingin repairs mild steel galvanised stay assembly set complete comprising of 14mm dia, 400mm long stay bow, 1800 mm long stay rod 20mm dia,300mm x 300mm x 6mm stay plate, thimble, GI stay wire of 7/8 SWG upto required length including loop type insulator of vitreous porcelain, small size with overall dimensions 90x140mm, clearance of hole 25.5mm,all as shown in electrical plate No.1 of MES Schedule part-I 1991 completeall as directed. |
| 5 | M & L for cement concrete 1:4:8 typr D-2 using 40 mm graded stone aggegrate as in foundation, filling and mass concrete complete all as specified and as directed. |
| 6 | M & L for cement concrete 1:3:6 typr C-2 using 40 mm graded stone aggegrate as in foundation, filling and mass concrete complete all as specified and as directed. |
| 7 | M & L for providing cement concrete 1:2:4 type B-1 using 20 mm graded stone as aggegrate in copings to poles & the like etc including weathering,slightly rounded or chamfered angles and throating etc complete all as specified and as diected. |
| 8 | Disconnecting electrically nacked LT cables from LT Panle/Main switch board of any sizeby taking proper electric shut down,removing ofcables from any type of soils/hard dense soil and cutting of unserviceable/overheated/nacked cable / thimbles etc and again for fixing of new aluminium lugs/copper lugs of any size up to 630 sqmm as required at site, insulation of all necked wires as per existing colour code, re-fixing/re-assembling as per existing system.Note :- (i) any addition/alteration required to be included in the quoted rate in the items.(ii)All consumable items such as thimbles, lugs, control wire up to 2 mtr is deemed to be included in the quoted rate. |
| 9 | Material and labour, painting of poleconsistingof 8.5/9 m long steel tubular poles including cross arms, clamps of any length and shape, for LT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm diacircle and marking bottom of pole to 1.5 m height, complete all as specified and as directed. |
| 10 | Material and labour, painting of two pole structure consistingof 8.5/9 m long steel tubular poles including cross arms, clamps of any length and shape, for LT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm diacircle and marking bottom of pole to 1.5 m height, complete all as specified and as directed. |
| 11 | Material and labour, painting of three pole structure consisting of 8.5/9 m long steel tubular poles including cross arms, clamps of any length and shape, for LT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm diacircle and marking bottom of pole to 1.5m height, complete all as specified and as directed. |
| 12 | Rectyfing the any leakage of current in neutral/EN voltage by checking overhead line, jumpers, under ground cable, mcb,mccb withrequired manpower to reducing the leakage in permissible limit i.eupto 3 volt and balancing the three phase supply complete all as directed by Engr-in-Charge. |
| 13 | Cleaning around any E/M installations/ pole structures including removing all grass, creepers and other vegetations with roots on soil, hard standing and on chain link fencing completeall as directed and removing the rubbish to a distance not exceeding 50 mtr and depositing where directed. |
| 14 | Cutting and trimming of branches n.exc 50 mm dia in size obstructing lumination of street light and touching line of LT and HT line all as directed. |
| 15 | M & L in repairsforCross arms, bracing, supports, clamps and back plate, fabricated from structural steel sectionincluding nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminum paint over a coat of red oxide primer, complete all as directed. |
| 16 | Supply and stringing in repair ACSR conductor ofany size forLT over headlineas directed includingfixing to insulators with proper size of binding wire complete. |
| 17 | All as per seritem No 16 (here in before) but GI wire 4 mm dia. |
| 18 | Re-stringing Over Head Line ACSR Conductor and earth wire of any size and type on LT poles including disconnection on Existing Lines by un-binding at Each Pin/Shackle Type Insulator, re-fixing the same after stretching Conductor, removing excess Sag, maintaining proper distance between Conductors adjusting line dividers etc and cutting trimming of tree branches upto 2 mtr clear distance from wire, complete all as directed by Engr-in-Charge. |
| 19 | Balancing of load on three phases and neutral of transformer by applying necessary engineering efforts like interchaging of jumpers, interchanging of service connections on over head conductors, in LT feeder pillar boxes or any other such efforts to make a balanced distributions of electrical load on transformer all as directed and required as per site conditions including submission of corrected readings of meters.(Note :- The unit rate quoted will include the cost of necessary tools, safety devices and plants required for the purpose) |
| 20 | M&L for LT PVC flat spacer suitable for 4 wireoverheadconductorcomplete all as specified and directed at site. |
| 21 | M&L for LT PVC flat spacer suitable for3 wireoverheadconductorcomplete all as specified and directed at site. |
| 22 | M&L for LT PVC flat spacer suitable for2 wireoverheadconductorcomplete all as specified and directed at site. |
| 23 | M&L for spreading of graded crushed aggregate 40 mm nominal size to a true surface and leveled in layers not exc. 20 cm thick for switch yard complete all as specified and directed by Engr-in-Charge. |
| 24 | Supply and fixing in replacementof flex fiber board of minimum thickness 5 mm,surface/wall mounted type,digitally painted with letters or figures(Block,Roman ,Italic or Indian) as per sample including cutting into pieces as persite requirement completeall as specified and directed at site. |
| 25 | Supply and fix in repairs GI strip 32 x 6 mm with PVC/porcelain insulators,nut bolts,fixing screws etc for GI earthing all as specified and directed by Engineer-in-Charge. |
| 26 | Supply and fixing in repair digital voltmeter, ranging from 0 to 500 Volts, including providing necessary electrical connections (to accommodate in panel board) complete all as directed by the Engr-in-Charge. |
| 27 | Supply and fixing in repair digital ammeter, ranging from 0 to 400 Amps (with CT of suitable ratio), including providing necessary electrical connections (to accommodate in panel board) complete all as directed by the Engr-in-Charge. |
| 28 | S & F in repairs Indicator Lamps (LED type)including providing necessary electrical connections (to accommodate in panel board) complete all as directed by the Engr-in-Charge. |
| 29 | M&L in repair LT cable Heatshrinkable straight throughjointing kit with jointing material and accessories suitable for 1100 volts grade LT XLPEarmoured aluminium conductorof size25 sqmm to 50 sqmm complete all as specified and directed by Engr-in-Charge.Note : Excavation ,returning filling etc measured separately. |
| 30 | All as per seritem No 29 (here in before) above butsuitable for70 sqmm to 120 sqmm |
| 31 | All as per seritem No 29 (here in before) above butsuitable for150 sqmm to 185 sqmm |
| 32 | All as per seritem No 29 (here in before) above butsuitable for240 sqmm to 300 sqmm |
| 33 | All as per seritem No 29 (here in before) above butsuitable for400 sqmm to 500 sqmm |
| 34 | M&L in repair LT cable Heatshrinkable Indoor/Outdoorjointing kit with jointing material and accessories suitable for 1100 volts grade LT XLPEarmoured aluminium conductorof size25 sqmm to 50 sqmm complete all as specified and directed by Engr-in-Charge.Note : Excavation ,returning filling etc measured separately. |
| 35 | All as per seritem No 34 (here in before) above butsuitable for70 sqmm to 120 sqmm |
| 36 | All as per seritem No 34 (here in before) above butsuitable for150 sqmm to 185 sqmm |
| 37 | All as per seritem No 34 (here in before) above butsuitable for240 sqmm to 300 sqmm |
| 38 | All as per seritem No 34 (here in before) above butsuitable for400 sqmm |
| 39 | Taking down Old burnt /Unserviceable2 core 16 Sqmm underground XLPE Cablealuminum conductor LT 1100 V gradeafter disconnecting of electric connectionall as specified and directed at site. |
| 40 | All as per seritem No 39 (here in before) but Size of cable 16 Sqmm X4 core |
| 41 | All as per seritem No 39 (here in before) but Size of cable 35/25 Sqmm X3.5 core |
| 42 | All as per seritem No 39 (here in before) but Size of cable 70/50 Sqmm X3.5 core |
| 43 | All as per seritem No 39 (here in before) but Size of cable 120 /95 Sqmm X3.5 core |
| 44 | All as per seritem No 39 (here in before) but Size of cable 185/150 Sqmm X3.5 core |
| 45 | All as per seritem No 39 (here in before) but Size of cable 240 Sqmm X3.5 core |
| 46 | All as per seritem No 39 (here in before) but Size of cable 300 Sqmm X3.5 core |
| 47 | All as per seritem No 39 (here in before) but Size of cable 400 Sqmm X3.5 core |
| 48 | Supply laying & testing ofXLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminum conductor, 1100 volts grade, laid in trenches, or fixed on poles & walls or laid under floorswith suitable size aluminum lugs complete of size 16 Sqmm nominal cross section 2 core complete all as specified and as directed. |
| 49 | All as per item No 48 (here in before) but Sizeof cable 16 Sqmm X4 core |
| 50 | All as per item No 48(here in before) but Size of cable25 Sqmm X3.5 core |
| 51 | All as per ser item No 48(here in before) but Size of cable35 Sqmm X3.5 core |
| 52 | All as per ser item No 48 (here in before) but Size of cable50 Sqmm X3.5 core |
| 53 | All as per ser item No 48 (here in before) but Size of cable70 Sqmm X3.5 core |
| 54 | All as per ser item No 48 (here in before) but Sizeof cable95 Sqmm X3.5 core |
| 55 | All as per seritem No 48 (here in before) but Size of cable 120 Sqmm X3.5 core |
| 56 | All as per seritem No 48 (here in before) but Size of cable 150 Sqmm X3.5 core |
| 57 | All as per seritem No 48 (here in before) but Size of cable 185 Sqmm X3.5 core |
| 58 | All as per seritem No 48 (here in before) but Size of cable 240 Sqmm X3.5 core |
| 59 | All as per seritem No 48 (here in before) but Size of cable 300 Sqmm X3.5 core |
| 60 | All as per seritem No 48 (here in before) but Size of cable 400 Sqmm X3.5 core |
| 61 | Supply and fix in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension GI wire, one twin core cable flat or circular with size 16 sqmm x 2 core complete all as specified and directed at site. |
| 62 | M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr below normal ground level ) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to main GI strip 32 x 6 mm as earth strip by means of bolts ,nuts and washers of galvanised iron or steel as shown in electrical plate No. 3, including exc , and earth work in any type of soil disposal of soil providing alternate layers of charcol and common salt construction of PCC earth chamber in mix 1:3:6 type C-1 with 40 mm thick 1:2:4 type B-1 cover reinforced with 8 mm dia MS bars both ways with lift hook made out of 8 mm dia bar,watering arrangement. Note : Main earth strip beyond 7.5 meter shall bemeasured and paid saperatly. Taking down old unserviceable dilapidated chemical earthing are included in quoted rate. Note :(1) 7.5 RM GI strip deemed to be included in quoted rates beyond 7.5 RM GI stripshall be measured and paid separately.(2) Earth resistance of earth pit should be less than 5 Ohms.On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.(3) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of GI Plate. |
| 63 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique/Manualand necessary machinesuitable for 40/50/80/100 mm GI pipe complete all as specified and directed at site |
| 64 | Cutting bituminous road/path for passing of elect cable through GI pipes and making good to the cut surfaces by concreating with PCC 1:3:6 to match with the adjescent surfaces complete all as dircted at site. |
| 65 | Supply and fixing steel tubes, galvanised, light grade, ISI marked 100 mm bore for protection of cable under floor, road and on wall complete. |
| 66 | Supply and fixing steel tubes, galvanised, light grade, ISI marked 80mm bore for protection of cable under floor, road and on wall complete. |
| 67 | Supply and fixing steel tubes, galvanised, light grade, ISI marked 50 mm bore for protection of cable under floor, road and on wall complete. |
| 68 | Supply and fixing steel tubes, galvanised, light grade, ISI marked 40 mm bore for protection of cable under floor, road and on wall complete. |
| 69 | Excavation in trenches, in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, or for shafts, wells, manholes, pier holes,cable laying, sewage/water lines etc complete all as specified and directed. |
| 70 | Returning,filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed. |
| 71 | Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 72 | Material and labour for sand cushioning with dry river sand in trenches for cushioningof underground cable line including spreading, leveling, well ramming completed all as specified and directed. |
| 73 | M&L sub class B brick,well burn laid bridth-wise along the length the cable laid intrench over sandcushion,laid for ug cableprotection complete all as specified and directed at site. |
| 74 | M&L for recharging of earthing by filling of common salt in earthing pits complete all as specified anddirected by Engr-in-Charge.Note: Recharging materials shall be soluble in water and to be filled/poured in earth pits after mixing in water inappropriate quantity. |
| 75 | Dismantling of insulators of any type & any size from any type of pole |
| 76 | S&F Pin Type Porcelain, Vitreous, Brown Insulator including one Galvanised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut, 100mm Height, 65mm dia for 1100 Volt Grade, complete all as directed. |
| 77 | S&F shackle type insulator, vitreous porcelain, white, brown or green Small size, with overall dimensions 50 x 65mm, clearance of hole 9 mm complete all as specified and as directed. |
| 78 | S&F Loop type insulator, vitreous porcelain, white, brown or green with overall dimensions 65 x 90mm, clearance of hole 16 mm complete all as specified and as directed. |
| 79 | Material & Labour for makingin replacement reflective glowsign boards made up ofstainless steel sheetnot less than 2 mm thick of size 1.5 m x 1 mtr,sky coloured ilumination top and writing with white coloured ilumination tape,letter size not less than 10 cm,frame made up of stainless steel angleof size 40 mm x 40 mm x 5 mm -1.2 mtrabove ground level includingfixing the legs in ground0.45 m indepth fixed /embedded in ground including excvation,PCC m-15 with using 20 mm graded stone aggregate in foundation of size 300 mm x300 mm x4000 mmand making good surface all as specified and directed. |
| 80 | Supply, Installing & testing and commissioning factory made and tested indoor type floor mounted, LT panel Cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated Aluminium bus bar 600 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 2.0 mm thick mild steel sheet ,size of panel not less than 1.85 m x 0.50 m x1.60 m, 40 x 40 x 5 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, both front & rear opening type with aprons for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size .The scope of work includes the following :- INCOMMING :-(a) MCCB 3 Pole, 415 Volt, 400 Amps, breaking capacity 36 k . - 01 No(c) Ammeter ,voltmeter with selector switch and energy meter square type to measure three/single Voltage phase, load current, frequency including necessary CT/PT of suitable ratio . :01 Set(d) LED Indicator lamp (R,Y,B)- Set of Three.OUTGOING :-(a)MCCB 3 Pole, 415 Volt, 250 Amps, breaking capacity 36 kA -02 Nos(b)MCCB 3 Pole, 415 Volt,200 Amps, breaking capacity 36kA -01 No(c)MCCB 3 Pole, 415 Volt,63 Amps, breaking capacity 25 kA -03 Nos |