| 1 | Supply of the following |
| 2 | ACSR Weasal (6/1/2.59mm) |
| 3 | PVC CABLES (SINGLE CORE) 120 mm2 |
| 4 | XLPE CABLE (HT) 3Cx120 sq. mm |
| 5 | LT AERIAL BUNCHED CABLE 3x50+1x16+1x35 sq.mm |
| 6 | ACCESSORIES OF LT AERIAL BUNCHED CABLE IPC Main 16-95 Sq. mm & Tap 4 to 35(50) Sq. mm |
| 7 | ACCESSORIES OF LT AERIAL BUNCHED CABLE -Eye Hook |
| 8 | ACCESSORIES OF LT AERIAL BUNCHED CABLE - Pole clamp (25/50 mm) |
| 9 | Rewireable Porcelain Cut out 200 Amp |
| 10 | 11KV Polymer composite 45 KN Disc Insulator |
| 11 | 11KV Polymer Pin Insulator |
| 12 | 11 KV Stay insulator |
| 13 | 11KV Disc fittings Up to 7/3.8mm, 2-U Bolt type |
| 14 | Stay set complete |
| 15 | GI Stay wire stranded stay wire 7-4mm |
| 16 | NUTS AND BOLTS (Assorted) |
| 17 | DANGER PLATE H.T. |
| 18 | DANGER PLATE L.T. |
| 19 | LUGS 120 mm2 - 12 |
| 20 | GI Stay clamp 50x6mm |
| 21 | Suspension clamp Assembly with straps & buckle (25-50 mm) |
| 22 | Dead end clamp Assembly with straps & buckle (25-50 mm) |
| 23 | 11 KV Gang Operated Switch (Porcelin type) |
| 24 | 11 KV Drop out Switch (Porcelin) |
| 25 | 11 KV Covered Conductor (70 SQMM) |
| 26 | 11KV VCB Panel rated Voltage 11KV-12KV, Rated Current 630A 800 1250 A, Nos of Pole 3 Poles, Frequency 50Hz with supply of power pack battery |
| 27 | 9 Mtr long Steel Tubular Pole 410 SP 28, Top & Middle pole painted with red oxide primer and bottom section Hot Dip Galvanised |
| 28 | 8 Mtr long Steel Tubular Pole 410 SP 15, Top & Middle pole painted with red oxide primer and bottom section Hot Dip Galvanised |
| 29 | Aluminium Lugs70mm sq |
| 30 | Aluminium Lugs95mm sq |
| 31 | Aluminium Lugs120mm sq |
| 32 | Aluminium Lugs 185 sq mm |
| 33 | Distribution Box 3 phase |
| 34 | MS Channel(100x50x50x6mm) |
| 35 | MS Channel(75x40x40x6mm) |
| 36 | MS Angle(65x65x6mm) |
| 37 | 11 KV LA |
| 38 | GI Strip 25x3mmfor DTR Earthing |
| 39 | PVC Sleeves |
| 40 | Erection |
| 41 | Erection of 9 mtrs length of Steel Tubular POLE at any kind of soil , including excavation of earth, refilling the pit withsoil upto the ground level, ramming and making complete in all respect. |
| 42 | Erection of 8.0mtrs length of Steel Tubular POLE at any kind of soil , including excavation of earth, refilling the pit withsoil upto the ground level, ramming and making complete in all respect. |
| 43 | Erection of Stay set direct in earth complete with 19mm x 1800 mm long stay rod, anchor plate of size 300 x 300 x 8 mm ,thimble, turn buckle, 7/3.15 mm dia G.I Standed stay wire and stain insulator etc. with Supply of M.S.Clamp,Nuts & Bolts etc. as required. and making complete in all respect |
| 44 | Erection of M. S. Angle Cross-Arm, 1.5 to 2.5 Mtr. Long 65x65x6mm (Excluding the cost of Bracket Clamp, Nuts & Bolts) |
| 45 | Erection of M. S. Channel Cross-Arm, 0.3 to 2.8 Mtr. Long 75x40x40x6mm (Excluding the cost of Bracket Clamp, Nuts & Bolts) |
| 46 | Erection of M. S. Channel Cross-Arm, 2.8 Mtr. Long 100x50x50x6mm (Excluding the cost of Bracket Clamp, Nuts & Bolts) |
| 47 | Erection of 11KV Pin insulator along with Pin. |
| 48 | Erection of 11KV Single Disc insulator set along with necessary fittings |
| 49 | Earthing with G.I pipe 2.5mtr. Long and 40mm dia, including excavation, refilling with alternate layer of salt & Charcoal as per drawing (excluding supply of G.I.Pipe, Salt & Charcoal, Gi wire, nuts &boIts, etc. as required) |
| 50 | Laying of 8 SWG GI wire at 300mm below the ground level for earthing of Sub-Station equipments from the earth electrode |
| 51 | Erection of DANGER PLATE on OH lines (11KV/415VoIts) |
| 52 | Fabrication of Cross-Arms by MS Channel/MS Angle as per specification |
| 53 | Laying and Stringing of 1KM (Single Conductor) ACSR 6/1/2.59 mm dia WEASEL including hoisting and binding etc. Complete as required. |
| 54 | Erection of 9KV, 5KA single pole metal oxide gapless type LA, including necessary connection complete as per technical specification |
| 55 | Erection of 11KV DOF unit set of three nos. including necessary connection complete as per technical specification. (Excluding the cost of back clamp, Nuts & Bolts) |
| 56 | Erection of 11KV 200 Amp. GOS unit set of three nos. including necessary connection complete as per technical specification.(Excluding the cost of back cIamp,Nuts & Bolts) |
| 57 | Installation/Positioning of 11/0.430KV,3-Phase 200KVA to 250KVA of Distribution Transformer on Pole with necessary connections & fitting fixing of all allied accessories components as required for making complete in all respect for energizing. |
| 58 | Carriage of 11/0.430, 3-Phase 200KVA/250KVA by Mechanical Transport from the Site / Store/ Worshop to working site Vis-a-vis including loading, unloading and placing on base, as required,b) Beyond 25 KM upto the lead of 50KMFrom MMD Store to Sub Division Store |
| 59 | Fitting-Fixing of Service main 1/3Phase distribution Box of 1.1 KV gradeon PCC/Steel Pole with the help Pole brackets or Steel Straps & buckIes as per direction of Engineer-In-Charge. |
| 60 | Supplying and Making Indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as requiredUp to 150sqmm |
| 61 | Fixing of cut out (Set of 3nos)on wooden plank (preferably korai wood) of size 24\"x10\"x1.5\"&cable connection with termination by lugs/thimbels) complete (i/c. supply of wooden plank, screws & M.S. clamp excluding cost of thimble) |
| 62 | Supply of febricated clamps of assorted size of MS flat (50x 6mm) with double coat of red oxide primer coating. |
| 63 | Supply of 2.5mtr. Long, 40mm dia G.I.Pipe, Make: TATA / JINDAL) |
| 64 | Supply of 60Kg Salt & 55Kg Charcoal ( For 1 Pit). |
| 65 | Positioning of cable drum, removing of cable from drum and laying, hoisting & drawing of AB Cable 3X50+1x16+1x35 sqmm as per direction of Engineer-In-charge. |
| 66 | Erection & Fitting-Fixing of Insulated suspention Clamp including Pole clamp, Eye hook for cable massenger of 1.1 KV grade on PCC/Steel Pole with the help Pole brackets or Steel Straps &buckIes asper direction of Engineering In-Charge. |
| 67 | Grouting of Steel Tubular PCC Pole of ratio 1:2:4 (1cement:2 riversand:4 Jhama brick Aggregate of 20mm. Nominal size) including supply of cement, sand and brick aggregate. Complete with excavation, refilling of each, ramming along with centering and shuttering as required |
| 68 | Maintaining adequate clearance from overhead live conductors by Trimming of tree branches for Way Leaves |
| 69 | Erection & Fitting-Fixing of Insulated Dead end enchoring Clamp including Pole clamp, Eye hook for cable massenger of 1.1 KV grade on PCC/Steel Pole with the help Pole brackets or Steel Straps &buckIes asper direction of Engineering In-Charge. |
| 70 | Supplying and Making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as requiredUp to 150sqmm |
| 71 | 11KV VCB panel for outgoing feedercomplete - For replacment / Extension in existing 11 kV feeder panel incuding fitting and fixing, cable terminations, bus extensions, adopter panel (if required) and including all accessories complete.R&M of 33/11kV SS |
| 72 | Civil work for construction of Transformer base andFencing of Hard drawn steel wire fabric as per requirement and direction of Engg. In Charge |
| 73 | Stringing of11KVCovered Conductor 70 sqmm (all 3 phases) as per specification and approved drawings, stringing of covered conductors at proper tension/ sag,fitting and fixing of all accesories Piercing Connectors , Jointing Sleeves, insulator binding using approved Non-metallic helical ties, jumpering, connections to other linesetc. complete in all respect. |
| 74 | Laying of PVC insulated and PVCsheathed / XLPE power cableof 11KV grade (120 Sq mm) in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Trench size: Width: 350 mm, Height: 1200 mm / Sand (Cushioning): Height: 250 mm, Width: 350 mm / Protection: Double layer bricks |