Power Government Departments Closing in 0 days TDR #48651062

Tender For Construction Of 400/132 Kv Park Pooling Substation (400 Kv Main Pps), Village: Soorasar And Bhanawatawala, Tehsil- Pugal Distt- Bikaner(Rajasthan) Including Supply Of All Equipments/Materials, Erection (Including Civil Works), Testing & Commisi

Issued by Government Departments · Bikaner, Rajasthan
Tender Value
442.74 Crore
Estimated cost
Bid Submission
04 Jun 2025
0 days left
EMD
8.85 Crore
Bank guarantee accepted
Document Fee
29500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bikaner → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Construction of 400/132 kV Park Pooling Substation (400 KV Main PPS), Village: Soorasar and Bhanawatawala, Tehsil- Pugal Distt- Bikaner(Rajasthan) including supply of all equipments/materials, Erection (Including Civil works), Testing & Commisioning on Turnkey basis at Pugal Solar park Phase-I

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 01-May-2025 Corrigendum against Pri-Bid Queries Technical Bid 20-May-2025
2 01-May-2025 Date Extension Date 20-May-2025
3 17-May-2025 Corrigendum for Time Line Date 03-Jun-2025
4 30-May-2025 Corrigendum for Schedule Date and Time Date 04-Jun-2025

BOQ

Name of Work:Construction of 400/132 kV Park Pooling Substation (400 KV Main PPS), Village: Soorasar and Bhanawatawala, Tehsil- Pugal Distt- Bikaner(Rajasthan) including supply of all equipments/materials, Erection (Including Civil works), Testing & Commisioning on Turnkey basis at Pugal Solar park Phase-I.
Sl. No. Item Description
1315 MVA, 400/132/33 kV AUTO TRANSFORMER
2315 MVA, 400/132/33 kV, 3 phase, 50 Hz, Auto transformer including insulating oil, ON LOAD TAP CHANGER, Digital RTCC Panel,atmoseal conservator, bushing CTs, self dehydreated breather, Optical Temprature Sensors including measuring Units alongwith all associated accessories/ Fittings as per specifications, one set of four Nos. Hydraulic jacks and Mandatory Spares as per Annex
3125 MVAr 420 KV BUS REACTOR
4125 MVAr, 420 kV, 3 phase, 50 Hz, Bus Reactor including insulating oil, atmoseal conservator, bushing CTs, self dehydreated breather,all other fittings and accessories as per technical specification with Mandatory Spares as per Annex
533/.433 kV, 500 kVA, LT THREE PHASE STATION TRANSFORMER
633/.433 kV, 630 kVA, LT three phase station transformer complete with all fittings, accessories and associated equipment as per specification with Mandatory Spares as per Annex.
7CIRCUIT BREAKERS
8420 kV,3150 Amp., 63 kA rupturing capacity circuit Breaker with closing resistor suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts, Terminal Connectors and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries with Mandatory Spares as per Annex.
9145 kV,2000 Amp., 40 kA rupturing capacity circuit Breakerwith mounting structures, foundation bolts and nuts, Terminal Connectors and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries with Mandatory Spares as per Annex.
10CURRENT TRANSFORMER
112000-1000/1-1-1-1-1 Amp., 63kA,420 kV singlephase multi core current transformers with120% extended current rating (Live Tank Type only) with terminal connector and Mandatory Spares as per Annex
122000-1000/1-1-1 Amp., 40kA,145 kV single phase multi core current transformers with120% extended current rating (Live Tank Type only) with terminal connector and Mandatory Spares as per Annex
13CAPACITIVE VOLTAGE TRANSFORMER
14420 kV single phase 4400 pF CVT suitable for high frequency (HF) coupling required for power line communication with voltage ratio 400/0.11 kV and three secondary windings with terminal connector and Mandatory Spares as per Annex
15145 kV single phase 4400 pF CVT suitable for high frequency (HF) coupling required for power line communication with voltage ratio 132/0.11 kV and three secondary windings with terminal connector and Mandatory Spares as per Annex
16POTENTIAL TRANSFORMER
17420 kV single phase PT with voltage ratio 400/0.11 kV, 0.2 Class, with two secondary windings with terminal connector and Mandatory Spares as per Annex
18145 kV single phase PT with voltage ratio 132/0.11 kV, 0.2 Class, with two secondary windings with terminal connector and Mandatory Spares as per Annex
19ISOLATOR
20420 kV 3150 Amp.,63kA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic fitted with single earth blade complete with accessories including terminal connectors and post insulators with Mandatory Spares as per Annex.Required capacity of isolators to be as per SLD and scope of work.
21420 kV 3150 Amp. , 63kA triple pole, gang operated horizontal double break type motor operated, outdoor Isolator metallic with double earth blade complete with accessories including terminal connectors and post insulators with Mandatory Spares as per Annex.
22420 kV 3150 Amp. , 63kA triple pole, gang operated horizontal double break type motor operated, outdoor Isolator metallic without earth blade complete with accessories including terminal connectors and post insulators with Mandatory Spares as per Annex.
23145 kV 2000 Amp., 40 kA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic fitted with single earth blade complete with accessories including terminal connectors and post insulators with Mandatory Spares as per Annex.
24145 kV 2000 Amp., 40 kA triple pole, gang operated horizontal double break type motor operated, outdoor Isolator metallic with double earth blade complete with accessories including terminal connectors and post insulators with Mandatory Spares as per Annex.
25145 kV 2000 Amp., 40 kA triple pole, gang operated horizontal double break type motor operated, outdoor Isolator metallic without earth blade complete with accessories including terminal connectors and post insulators with Mandatory Spares as per Annex.
26SURGE ARRESTERS
27Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 390 kV lightning arresters suitable for connection between phase and ground on 3 phase 420 kV neutral grounded system complete with insulating base, surge counter and current meter, accessories with Mandatory Spares as per Annex.
28Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 120 kV lightning arresters suitable for connection between phase and ground on 3 phase 132 kV neutral grounded system complete with insulating base, surge counter and current meter, accessories with Mandatory Spares as per Annex.
29WAVE TRAP
30400 kV, 1.0mH / 3150 A Wave Traps Pedestal mounting type with tuning unit, protection device, terminals clamps, corona rings, bird barriers etc.
31132 kV, 0.2 mH / 2500 A Wave Traps Pedestal mounting type with tuning unit, protection device, terminals clamps, corona rings, bird barriers etc.
32CONTROL,RELAY & PROTECTION PANELS COMPATIABLE WITH SUBSTATION AUTOMATION SYSTEM ALONG WITH ASSOCIATED EQUIPMENTS AND MANDATORY SPARES AS PER ANEXX.
33400 KV Bus Bar Protection Scheme having one no. central unit and 16 nos. peripheral units (PU)
34GPS with Digital clock
35Phasor Measurement Unit with accessories
36Necessary software and hardware alongwith laptop to up / down load the data / from the relays from / to the laptop. The supply of laptop is covered under this scope.
37SUBSTATION AUTOMATION SYSTEM
38Complete substation automation system along with necessary license, grid security, redundancy provision and spares for 5 years satisfactory operation as per scope of the specification.
39Supply. erection, testing & commissioning of Ethernet Switch, Gateway, Firewall, OFC, BCU, IEDs etc. to complete the scope specification .
40COMMUNICATION AND CARRIER PROTECTION EQUIPMENTS
41PLCC equipments with associated accessories
42Fibre Optic Telecummunication equipments with associated accessories
43BATTERY AND BATTERY CHARGER
44220 V, 600 AH Tubular Lead AcidBattery set along with accessories, standetc.
45220V, 100Amp/70Amp float cum boostBattery Charger (Separate sections for float and boost charging operation).
4648 V, 600 AHVRLA Battery setalong with accessories, stand and spares.
4750 V, SMPSbattery charger of 100 Amp. DC Load capacity suitable for charging of VRLA battery set alongwith additional one No. 25 SMPS Module.
48LT SWITCHGEAR
49AC DISTRIBUTION BOARD (For triple source as per IS)
50DC DISTRIBUTION BOARDNote:- ACDB & DCDB should be designed in such a manner so that each AC and DC feeder have duplicateconnectivity.
51DG SET Diesel Generator set of stationary type having a net electrical out put of 160KVA capacity at specified site conditions with all its accessories for installation at 400 kV substation
52HARDWARE AND BUS BAR MATERIAL
53EARTHING MATERIAL (GS & MS flats of all sizes and Cu/Al Flexible braids)
5433 KV 3 phase H G Fuse set with support structure
55Marshalling KioskFor 400 Kv and 132kV
56Cables along with accessories as per requriment
57Copper Control Cableas per requriment
58Power Cables as per requriment
59FRLS Cables as per requriment
60XLPE Cable for 33kV Station Transformer as per requriment
61ACSR Moose conductor
62AAC Tarantulla conductor
63HTLS conductor
64GS Earth wire
65ILLUMINATION SYSTEM :
66Switchyard Flood Lighting
67Control room building & street lighting
68FIRE FIGHTING SYSTEM ( AS PER TECHNICAL SPECIFICATION)
69Mulsifyre System
70Hydrant System
71Fire detection & alarm system
72Hand appliances as per Annex
73AIR-CONDITIONING AND VENTILATION SYSTEM FOLLOWING
74Design, supply, installation, testing and commissioning of Air conditioning & ventilation system for the control room building for Control Room, PLCC Room, SE/XEN/AEN/Staff/Rest Rooms alongwith the necessary spares for satisfactory operation for 5 (five) years.
75STRUCTURES :Design, engineering, procurement of materials, fabrication galvaising, proto- assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure.Conforming to IS:2062 and GI pipe conforming to grade YST 22 or higher grade as per IS:806.
76Standard Lattice Structure [Design, engineering, procurement of materials, fabrication, galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, washer, gusset plates, base plates, foundation bolts and other accessories for lattice steel structure as per specification requirements]:
77Non-Standard Lattice Structure [Design, engineering, procurement of materials,fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]
78Non-Standard Pipe Support Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for Pipe Support structure as per specification requirements]Note:-(1)The above estimated quantities of structures are only for tender purpose. The contractor shall supply, erect & commission the structures to meet out complete requirement for successful commissioning ,maintenance & operation of the substation in accordance with the specification.(2) Details of Tower structures & girders / beams available in Vol.II, of specification are tentative and for tender purpose only. The bidder shall have to design the structures & girders / beams based on actual loadings on the basis of short circuit force calculations, if required.
79Supply. erection, testing & commissioning of Solar Insolation cum Weather Monitoring System along with associated accessries
80Testing & Measuring equipments as per Annex.
81General tools & tackles as per Annex.
82Office & Misc equipments / items as per Annx
83Furniture for Control Room building as per Annex.
84Desktop Computer, Laser Printer and photocopy machine with latest configuration as per Annex.
85Add: Any other supply item, if any, bidder may require completing the substation as per specification requirements. (if amount quoted, list of items alongwith quantity be indicated in technical offer)*Note :- BOQ shown above is for tender purpose only. It shall be finalized at the time of detail engineering by bidder as per the specification / requirement.

AI Tender Summary

OUR REF NO 48651062
AUTHORITY Government Departments
TENDER VALUE 442.74 Crore
LAST DATE 04-06-2025
Authority
Authority Name Rajasthan Renewable Energy Corporation Limited
Work Description Construction of 400/132 kV Park Pooling Substation (400 KV Main PPS), Village: Soorasar and Bhanawatawala, Tehsil- Pugal Distt- Bikaner(Rajasthan) including supply of all equipments/materials, Erection (Including Civil works), Testing & Commisioning on Turnkey basis at Pugal Solar park Phase-I
Basic Detail
Tender No RSDCL/Pugal/TN-01 (2025-26)
Bidding Type Tender
Location
City Bikaner
State Rajasthan
Key Dates
Publish Date 30 May 2025
Submission Date 04 Jun 2025
Open Date 05 Jun 2025
Finance
Tender Value 442.74 Crore
Tender Fee 29500
EMD 8.85 Crore
Exemption Available
Document List
2c09af63-aa8b-40a6-9676-58f4f9299350.html
BOQ_821710.xls
Volume3C.pdf
Volume4.pdf
Volume5A.pdf
DPRPHASE1.pdf
Tendernotice_1.pdf
Volume3A.pdf
Volume3B.pdf
Volume1.pdf
Volume2.pdf
Volume5B.pdf
Volume6.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 30, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
May 20, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 20, 2025
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 03, 2025
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 04, 2025
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 04, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 05, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

2c09af63-aa8b-40a6-9676-58f4f9299350.html

xls

BOQ_821710.xls

pdf

Volume3C.pdf

pdf

Volume4.pdf

pdf

Volume5A.pdf

pdf

DPRPHASE1.pdf

pdf

Tendernotice_1.pdf

pdf

Volume3A.pdf

pdf

Volume3B.pdf

pdf

Volume1.pdf

pdf

Volume2.pdf

pdf

Volume5B.pdf

pdf

Volume6.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender